Black Box ISU2011-8-EURO, ISU2011-4-EURO, ISU2011-4-UK, ISU2011-8-UK User Manual

4-Port BRI-Hub (UK): ISU2011-4-UK
4-Port BRI-Hub (Euro): ISU2011-4-EURO
8-Port BRI-Hub (UK): ISU2011-8-UK
8-Port BRI-Hub (Euro): ISU2011-8-EURO
BRI-Hub
TECHNICAL:
SALES:
FAX:
ADDRESS:
WEB:
BRI-Hub
How To Contact your Local Black Box
Italy: Australia:
Black Box Italia S.P.A Black Box Catalog Australia PTY LTD Tel: 0227400280 Tel: 0398797100 Fax: 0227400219 Fax: 0398702955 Web Site: www.blackbox.it
Deutschland: Brazil:
Black Box Deutschland Black Box Do Brasil. Tel: 0811/5541-0 Tel: (011) 5515-4000 Fax: 0811/5541-499 Fax: (011) 5515-4002 Web Site: www.blackbox-deutschland.com Web Site: www.blackbox.com.br
Switzerland: Canada:
Datacom Black Box Services AG Black Box Canada Corp. Tel: 0554517070 Tel: 0416-736-8000 Fax: 0554517075 Fax: 0416-736-7348 Web Site: www.black-box.ch Web Site: www.blackbox.com
Netherlands: Mexico:
Black Box Datacom BV Black Box De Mexico S.A. de C.V Tel: 03032417799 Tel: 05-420-0100 Fax: 0302414746 Fax: 05-420-0123 Web Site: www.blackbox.nl/ Web Site: www.blackbox.com.mx
Belgium: Japan:
Black Box Black Box Catalog Tel: 027258550 Tel: 03-3820-5011 Fax: 027259212 Fax: 03-3820-5010 Web Site: www.blackbox.be Web Site: www.blackbox.co.jp/
France: U.S.A
Black Box Catalogue Black Box Corporation Tel: 0145606700 Tel: 724-746-5500 Fax: 0145606747 Fax: 724-746-0746 Web Site: www.blackbox.fr Web Site: www.blackbox.com
Spain: Chile
Black Box Comunicaciones S.A. Black Box Chile Tel: 34 91 663 0200 Tel: 00 562 223 8811 Fax: 34 91 661 84 35 Fax: 00 562 225 1002 Web Site: www.blackbox.es Web Site: www.Blackbox.cl
SALES: 0118 965 5100
2
BRI-Hub
Contents
Introduction............................................................................................................................... 4
Description of functions................................................................................................ 4
Options.......................................................................................................................... 5
BRI-Hub............................................................................................................ 5
BRI-Hub S......................................................................................................... 5
Technical Specifications ........................................................................................................... 6
SO Interface BRI........................................................................................................... 6
Common Features ......................................................................................................... 6
Power supply................................................................................................................. 6
Power Supply ................................................................................................................ 7
Sound Emission............................................................................................................. 7
S0-Interface............................................................................................................................... 6
Parts List.................................................................................................................................... 7
Installation................................................................................................................................. 8
Tabletop......................................................................................................................... 8
Wall mount.................................................................................................................... 8
Rack Mount................................................................................................................... 8
Power Supply ............................................................................................................................ 9
BRI-Hub........................................................................................................................ 9
BRI-Hub-S .................................................................................................................... 9
Connecting the Hub................................................................................................................. 10
Power Failure Operation ............................................................................................. 11
Termination Resistors ..................................................................................... 13
Operation................................................................................................................................. 14
Displays and Controls ................................................................................................. 14
Displays........................................................................................................... 14
Controls........................................................................................................... 14
Maintenance............................................................................................................................ 14
Cleaning ...................................................................................................................... 14
Troubleshooting ...................................................................................................................... 15
TECHNICAL: 0118 931 2233
3
BRI-Hub
Introduction
Within the data communications and LAN industry it is well known that a structured cabling concept using a star topology has significant advantages, such easier maintenance, unproblematic changes in the configuration and faster fault finding. Last but not least, a structured cabling concept may be used for all kinds of LAN-, WAN and telecommunications technologies.
Nevertheless, with ISDN a bus has to be formed to connect several users to one Basic Rate Interface (BRI), but a bus cannot be formed with a star topology. Alternatively a complete BRI must be dedicated to one user (point to point configuration), which is in many cases not feasible or too expensive.
By using the active star BRI-Hub it is now possible to use the struct ured star-cabling concept for ISDN. In addition the distance between the NT and the TEs may be extended because of the use of point-to-point links between the BRI-Hub and the TEs. It is also possible to use the "extended passive bus configuration" (distance up to 1000m) if all connections to the TEs are in the same range of distance (+/- 50m).
The Phantom Feed unit can be used with the BRI-Hub to provide power to all 4 or 8 ports on the BRI-Hub.
Description of functions
The BRI-Hub converts the ISDN BRI bus structure to a set of point-to-point connections, which are connected within the BRI-Hub to form a 'logical bus'. At this, the BRI-Hub makes it possible to hook up ISDN terminals via a maximum of 8 lines with the maximum length of 150 m each. Up to 1000 m is possible in a special configuration. Every port forms a separate electrical segment. Through this wiring faults don't affect other segments.
4
SALES: 0118 965 5100
BRI-Hub
If a BRI needs to be made available in several rooms, it used to be necessary to install a bus from the server room through all rooms. (See picture ‘old’). Now star wiring can be used with BRI-Hub, which comes to use also for telephone and local area networks (see picture 'with BRI-Hub').
Options
BRI-Hub
This option derives its power from the power supply provided.
BRI-Hub S
This option derives power from the S-Bus and uses an internal DC-DC converter to adapt the voltage to power itself – no external power supply is required. This option is available as a special request from Black Box.
Both of the above options can be used in conjunction with the Phantom Feed, a device used to provide power on each of the hub’s S interfaces.
TECHNICAL: 0118 931 2233
5
BRI-Hub
Technical Specifications
SO Interface BRI
Number of interfaces……………………………………5 for BRI-Hub-4, 9 for BRI-Hub -8 Type and coding…………………………………………I.430, Mod. AMI, 4-wire Frame structure………………………………………….I.430 (48 Bits per 250 µs) Transmission rate………………………………………..192 kbps +/- 50 ppm Interface connector………………………………………RJ-45
Common Features
Size (W x H x D)………………………………………..205 x 40 x 110 mm Weight………………………………………………….. 450g Housing material……………………………………….. ABS Protection class………………………………………….IP 21 Environmental temperature……………………………..0° to 40° C Storage temperature……………………………………..-20° to 70° C Humidity……………………………………………….. max. 90% (non condens.) Supply voltage…………………………………………..6 - 9V Power consumption……………………………………. max. 2W
Power supply
Primary voltage………………………………………… 220V~ +/-10%, 50 Hz Output voltage…………………………………………..6V= Output current………………………………………….. max. 500mA
6
S0-Interface
Connector: RJ-45 (ISO 8877, EN 28877)
Pin Signal Direction Power Feeding
1 PS3 + 2 PS3 ­3 TE(+) TE  NT PS1 + (Phantom) 4 NT(+) NT  TE PS1 - (Phantom) 5 NT(-) NT  TE PS1 - (Phantom) 6 TE(-) TE  NT PS1 + (Phantom) 7 PS2 ­8 PS2 +
SALES: 0118 965 5100
Environmental and Safety Notes
The device conforms to all european and international standards for safety, environment, EMC and the ISDN basic rate interface.
Power Supply
The power adaptor is according to safety class II (VDE 0551) and my only be used
indoor.
Do not use the power adaptor when it was brought from a cold to a warm
environment. In that case condensing water may damage the unit.
There are no user serviceable part inside the power adaptor. Therefore it is not
necessary to open the unit
Sound Emission
The unit does not emit any sound.
BRI-Hub
Parts List
When opening your BRI-Hub the following parts should be present:
BRI-Hub unit
ISDN cable with two RJ45 plugs (Western plugs) to connect the BRI-Hub to the
network termination (NT) or the PABX basic rate interface. The cable has a length of 2m.
Power Supply adaptor (not with BRI-Hub-S)
Users Manual
Two 6mm dowels and two 6mm screws for wall mounting
The power feeding unit, The Phantom Feed, may be used to feed all TE ports with power (40V, 8W). This device is available as an option.
TECHNICAL: 0118 931 2233
7
BRI-Hub
Installation
For proper operation the device must be placed in a suitable location. It should be a clean and dry environment without direct sun light. Sufficient cooling must be possible. Do not pack or cover the unit or set other warm equipment on top of it.
Tabletop
Just place the unit on a clean and dry place. Multiple BRI-Hub units may be stacked. The rubber stands give enough space for proper cooling.
Wall mount
The wall assembly works as follows:
Drill two holes vertically, one above the other with a separation of 95 mm, into the wall
where you want to place the BRI-Hub.
Completely put the dowels into the drilled holes.
Turn the BRI-Hub screws into the dowels; with a separation of approx. 7 mm still left
between wall and screw head.
Now place the BRI-Hub so that the screws fit into the holes in th e floor plate. The power
LED is in the upper right corner.
Carefully shift the BRI-Hub downward, so that the screws move into the slots inside the
floor plate.
Caution! Don't use any excessive force. If the screws are turned too far into the dowels, the screws may not move into the slots. Turn the screws out a little and try again.
Rack Mount
For the assembly into a rack an optional 19” front panel is needed. This may hold one or two BRI-Hub devices. This 19”rackmount panel is available as a special from Black Box. Please call technical support for further information. The front panel is fixed to the BRI-Hub devices by two engine screws.
To do this the panel is set onto the front of the BRI-Hub.
The two screws are put into the holes of the panel provided for this. (Left from the NT
port and right besides the power LED.
SALES: 0118 965 5100
8
BRI-Hub
The screws must be put into the holes of the BRI-Hub. The screws slide approximately 25
mm into the case.
The screws can be screwed in tight.
Power Supply
BRI-Hub
The standard BRI-Hub is supplied with a wall mount power adapter. There is no power switch at the device. The BRI-Hub is active when the power adaptor is plugged into an outlet and the DC connector of the power adaptor is connected to the BRI-Hub.
BRI-Hub-S
Besides the operation with a power adaptor it is possible for a BRI-Hub-8S or BRI-Hub-4S to get its power through the power feeding of the NT or PABX via the NT port. Please note that the BRI-Hub needs approximately twice the power as an ISDN telephone. Therefore it is not possible to operate the BRI-Hub from the ‘restricted mode’ power feeding.
If the DC connector of the power adaptor is plugged into the BRI-Hub DC socket, the BRI­Hub will switch to the power adaptor automatically even if the power supply doesn't deliver any electrical power. Therefore it is necessary to unplug the DC connector from the BRI-Hub when the power feeding of the BRI is used.
TECHNICAL: 0118 931 2233
9
BRI-Hub
Connecting the Hub
6V DC
CE
The DC connector of the power adapter is inserted into th e jack on the left side of the rear panel (Jack "6V DC").
Do not use other power adaptors than the original one. In any case notice the polarity of the connector. Inner tip +, outer ring -.
To connect the BRI-Hub to the NT or an internal BRI of a PABX, use one of the connectors labelled 'NT'. Use the enclosed ISDN-cable. Both connectors are parallel connected, so it doesn't matter which one you chose. The second connector may be used to connect a test device or other TEs. (see ‘Power Failure Operation’ on next the page).
Termination of the NT-port may be switched on and off using the Term-switch. When installing the BRI-Hub, check that both ends of the bus are terminated properly, but only the ends!
Depending on the quality of your cables, a maximum length of 150m may be connected to every TE-port of the BRI-Hub. Note that the sum of the cable lengths (NT-BRI-Hub plus BRI-Hub-TE) should not exceed 150m. Since the BRI-Hub will normally be placed directly next to the NT or the PABX, the entire 150m are available for the TE connection.
10
SALES: 0118 965 5100
BRI-Hub
The TE-ports termination resistors are permanently active and cannot be switched off.
Please install terminating resistors to the end of the connecting cables.
In the above example the Term-switch must be in the off position, i.e. termination resistors are off. This is because the BRI-Hub is not connected to the end of the bus.
Power Failure Operation
If the BRI-Hub loses power, the terminal devices directly connected to the NT ports will still operate. For this to happen case one must observe the maximum cable length and the position of the terminating resistors. In more detail this is:
The length of the cable connecting the NT to the BRI-Hub plus the length of the cable
connecting the BRI-Hub to the TE on the second NT port must not be longer than 150m. Both cables form a passive bus.
In case of a bus installation at the NT port, BRI-Hub must be the last device on the bus.
The termination resistors must be switched off. Termination resistors must be installed at
the end of the TE’s bus
TECHNICAL: 0118 931 2233
11
BRI-Hub
Configuration for power fail communication with the BRI-Hub
If cable connections between the BRI-Hub and the terminal equipment (TE) are longer than the proposed 150m, operation may be possible under specific conditions:
1. The NT must be switched to "extended passive bus". "Point-to-point" or "adaptive timing”.
2. All cable connections at the TE ports must have the same range of length, i.e. +/- 50 to 100m, depending on the cable quality.
12
SALES: 0118 965 5100
BRI-Hub
Termination Resistors
The signal pairs must be terminated with 100 resistors at both ends of the bus.
These must be installed as shown below. If not placed correctly, they may short the power feeding voltage.
Pin Pin description Direction
1 2 3 2a TE  NT 4 1a NT  TE 5 1b NT  TE 6 2b TE  NT 7
100 each
8
TECHNICAL: 0118 931 2233
13
BRI-Hub
Operation
No service is needed during operation.
Cable shorts at one TE port only affect the power feeding voltage of all ports if they are internally connected. To reduce this effect self-healing fuses are connected to each port.
The current version of the BRI-Hub cannot clear problems with cable reversals of the TE pair (Pins 3 and 6 of the RJ-45). If one of the connected TEs has such a pair reversal, no operation is possible since the pulses sent by different TEs have different polarity.
Displays and Controls
Displays
Pwr is on (green), when the BRI-Hub is operating. I.e. the power supply is active.
This may be the power adaptor or the power feeding when using the 'S' option (BRI-Hub-S)
Controls
Term On: (down position). Both pairs of the NT port are terminated (100Ω). Off: (up position). Termination resistors off.
Maintenance
Cleaning
To clean the BRI-Hub use a damp piece of cloth or antist atic cloth. Please do not use scori ng or alcoholic fluids.
Caution! Never clean the BRI-Hub wet. This may cause short circuits inside the device.
14
SALES: 0118 965 5100
BRI-Hub
Troubleshooting
Fault Problem How to clear the problem
Pwr-LED is off BRI-Hub is powered off Plug in power adaptor No mains power Check for main power Faulty power adaptor Use other compatible power adaptor. Check
polarity!
For BRI-HUB-S only:
loss of power inside NT or PABX
BRI-Hub is faulty
Specific devices on a port do not operate via the BRI Faulty terminal
Cable too long Connect TE directly to the BRI-Hub for test Only devices at port 1 may communicate
If you are still having problems with you BRI-Hub, please call Black Box technical Support.
Cable shorts Use another port for test.
equipment
A BRI-HUB is used which is in the power down mode
Use original power adapter
Please return the device to your dealer.
Check for cabling faults.
Check with other equipment
Power on the BRI-HUB
TECHNICAL: 0118 931 2233
15
BRI-Hub
Notes
16
SALES: 0118 965 5100