Black Box ACXC32, ACXC48, ACXC16 User Manual

ACX0 48 ACXIO8-C ACXSFPC ACX288 -PS ACX080 ACXIO8-SM ACXSFPS ACXC16 ACX160 ACXIO8-SPF ACX080 -PS ACXC32 ACX288 ACX288 -C TL AC X160- PS ACXC4 8
ServSwitch™ DKM FX and DKM FX Compact
Provides flexible and super-fast crosspoint switching of Full HD video in KVM enterprises.
Customer
Support
Information
724-746-0746 • Mailing address: Black Box Corp oration, 1000 Park Drive, Lawrence, PA 15055-1018 • Web site: ww w.blackbox.com • E-mail: info @blackbox.com
Trademarks Used in this Manual
Trademarks Used in this Manual
Black Box and the Double Diamond logo are registered trademarks, and ServSwitch is a trademark, of BB Technologies, Inc.
Mac is a registered trademark of Apple Computer, Inc.
IBM is a registered trademark of International Business Machines Corporation.
Java is a registered trademark of Oracle Corporation.
TOSLINK is a registered trademark of Toshiba Corporation.
Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
NOTE: The ServSwitch DKM FX and the ServSwitch DKM FX Compact function in
similar ways. The difference between them is described in the table below.
Table 1. ServSwitch DKM FX and DKM FX Compact comparison.
Serv Switch DKM FX Compact ServSwitch DKM FX
Number of Ports 16-, 32-, 48 -por t options 48-, 80-, 160-, 288-port options
Type of Ports CATx I/O ports only CATx/fiber I/O ports dependent on I/O card
Form Factor Small form factor (1U) Large form factor (4U+)
Modular or Not Not modular Modular
Page 2
724-746-5500 | blackbox.com
FCC and IC RFI Statements/NOM Statement
FEDERAL COMMUNICATIONS COMMISSION AND
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para
referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de
operación deben ser respetadas.
724-746-5500 | blackbox.com
Page 3
NOM Statement
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales
que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor
como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del
tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no
sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea
usado por un largo periodo de tiempo.
Page 4
724-746-5500 | blackbox.com
NOM Statement
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean
derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su
desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
724-746-5500 | blackbox.com
Page 5
Safety Instructions
Safety Instructions
For reliable and safe long-term operation of your ServSwitch DKM FX, follow these
guidelines:
Installation
• Only use in dry, indoor environments.
• The ServSwitch DKM FX and the power supply units can get warm. Don’t put them
in an enclosed space without any airflow.
• Do not obscure ventilation holes.
• Only use power supplies originally supplied with the product or manufacturer-
approved replacements. Do not use a power supply if it appears to be defective or has a damaged case.
• Connect all power supplies to grounded outlets. In each case, make sure that the
ground connection is maintained from the outlet socket to the power supply’s AC power input.
• Do not connect the link interface to any other equipment, particularly network or
telecommunications equipment.
• Only connect devices to the serial interface that are sufficiently secured against
short circuits and false voltages at the serial interface.
• To disconnect the switch from the power supply, remove the power cords of all
power supply units that are in use or set the power switch (if available) to the OFF position.
• Take any required ESD precautions.
Repair
• Do not attempt to open or repair a power supply unit.
• Do not attempt to open or repair the ServSwitch DKM FX. There are no
user-serviceable parts inside.
• Contact Black Box Technical Support at 724-746-5500 or info@blackbox.com if there is a fault.
Page 6
724-746-5500 | blackbox.com
Table of Contents
Chapter Page
1. Specifications .........................................................................................11
1.1 I nte rf ac es .........................................................................................11
1.1.1 DVI-D Single Link ..................................................................11
1.1.2 USB HID ................................................................................11
1.1.3 RJ-45 (Network) ....................................................................12
1.1.4 RS -232 (Serial ) .......................................................................12
1.1.5 RJ-45 (Interconnect) ..............................................................12
1.1.6 Fiber SFP Type LC (Interconnect) ...........................................12
1.1.7 SDI (Interconnect) ..................................................................12
1.2 Interconnect Cable ..........................................................................12
1.2.1 CATx......................................................................................12
1.2.2 Fiber ......................................................................................13
1.2.3 Coaxial ..................................................................................14
1.3 Supported Peripherals .....................................................................15
1.4 Connector Pinouts ...........................................................................15
1.4.1 CPU Board .............................................................................15
1.4.2 I/O Board CATx .....................................................................17
1.4.3 I/O Board SFP ........................................................................17
1.4.4 I/O Board SDI ........................................................................17
1.5 Power Supply...................................................................................18
1.6 Environmental Conditions ................................................................18
1.7 Size......... . ........................................................................................18
1.8 Shipping Weight ..............................................................................18
2. Overview............ ......................................................................................19
2.1 Description ......................................................................................19
2.1.1 A ppl ic at io n ............................................................................19
2.1.2 Access Options ......................................................................19
2.2 System Overview ............................................................................ 20
2.3 Available Products ...........................................................................21
2.4 What’s Included ..............................................................................21
2.5 Device Views .................................................................................. 23
2.5.1 ServSwitch DKM FX 288-Port .............................................. 23
2.5.2 ServSwitch DKM FX 160-Port ...............................................24
2.5.3 ServSwitch DKM FX 80-Port .................................................25
2.5.4 ServSwitch DKM FX 48-Port .................................................26
2.5.5 ServSwitch DKM FX Compact 48-Port ..................................26
724-746-5500 | blackbox.com
Page 7
Table of Contents
Chapter Page
2.5.6 ServSwitch DKM FX Compact 32-Port ................................. 28
2.5.7 ServSwitch DKM FX Compact 16-Port ................................. 29
2.6 Diagnostics and Status ................................................................... 30
2.6.1 Status LEDs ........................................................................... 30
2.6.2 Port Status ............................................................................ 38
2.6.3 Extender OSD ....................................................................... 42
2.6.4 Network Status .................................................................... 43
2.6.5 Firmware Status .................................................................... 45
2.6.6 Firmware Status Extender ......................................................47
2.7 Trace Function ................................................................................ 48
2.8 Syslog Monitoring ........................................................................... 49
2.9 SNMP .........................................................................................51
3. Installation ............................................................................................. 53
3.1 System Setup .................................................................................. 53
3.2 Example Applications ..................................................................... 54
3.2.1 KVM Matrix ..........................................................................55
3.2.2 Video Matrix ........................................................................ 56
3.2.3 Parallel Operation (Stacking)................................................. 56
3.2.4 Cascading ............................................................................ 58
4. Configuration .........................................................................................59
4.1 Command Mode .............................................................................59
4.2 Control Options .............................................................................. 60
4.2.1 Control via OSD ....................................................................61
4.2.2 Control via Java Tool ............................................................ 65
4.2.3 Control via Serial Interface ................................................... 73
4.3 Assignment .....................................................................................74
4.3.1 Virtual CPU ............................................................................74
4.3.2 Virtual Console ..................................................................... 77
4.4 System Settings .............................................................................. 80
4.4.1 System Data ......................................................................... 80
4.4.2 Automatic ID ........................................................................ 83
4.4.3 Access .................................................................................. 85
4.4.4 Switch .................................................................................. 88
4.4.5 Network ................................................................................91
4.4.6 Date and Time ...................................................................... 94
Page 8
724-746-5500 | blackbox.com
Table of Contents
Chapter Page
4.5 User Settings ................................................................................... 96
4.5.1 User Data ............................................................................. 96
4.5.2 Favorites List Users ............................................................. 100
4.5.3 User Macros ........................................................................103
4.6 Extender Settings ......................................................................... 106
4.6.1 Creating Flex-Port Extender Units ....................................... 109
4.6.2 Creating Fixed-Port Extender Units .................................... 109
4.6.3 Deleting Flex-Port Extender Units ....................................... 109
4.6.4 Deleting Fixed-Port Extender Units ..................................... 109
4.7 CPU Settings .................................................................................. 110
4.8 Console Settings ............................................................................114
4.8.1 CON Devices .......................................................................11 4
4.8.2 Mouse and Keyboard ..........................................................118
4.8.3 Extender OSD ......................................................................121
4.8.4 Favorite List Consoles ..........................................................123
4.8.5 Console Macros ..................................................................125
4.9 Saving and Loading of Configurations ...........................................129
4.9.1 Active Configuration ...........................................................129
4.9.2 Saving of Configurations (Internal) ......................................129
4.9.3 Loading of Configurations (Internal) ....................................131
4.9.4 Saving of Configurations (External) .....................................133
4.9.5 Loading of Configurations (External) ...................................134
4.10 Export and Import Options .........................................................135
4.10.1 Export Options ....................................................................135
4.10.2 Import Options ...................................................................136
4.11 Firmware Update ..........................................................................137
4.11.1 Matrix Update .....................................................................137
4.11.2 Extender Update .................................................................139
4.12 License Management ...................................................................143
5. Operation ........................................................................................145
5.1 Operation via Hotkeys .................................................................145
5.1.1 Direct Switching ...............................................................145
5.1.2 Scan Mode ......................................................................14 6
5.1.3 Function Keys <F1>–<F12> .............................................147
5.1.4 Addressing of Main and Sub Matrices .............................147
5.2 KVM Switching ........................................................................... 148
724-746-5500 | blackbox.com
Page 9
Table of Contents
5.3 Extended Switching ..................................................................... 151
5.4 USB 2.0 Switching .......................................................................157
5.5 Presets ........................................................................................157
5.6 Serial Interface .............................................................................159
5.7 Power On and Power Down Functions ........................................159
5.7.1 Restart .............................................................................159
5 .7. 2 Re se t ................................................................................160
5.7.3 Power Down ....................................................................160
6. Serial Control ........................................................................................161
7. Troubleshooting ...................................................................................173
7.1 External Failure ..............................................................................173
7.2 Video Interference .........................................................................173
7.3 Fans Malfunction ...........................................................................173
7.4 Power Supply Units Malfunction ...................................................174
7.5 Network Error ................................................................................174
7.6 ServSwitch DKM FX Failure ........................................................... 174
7.7 Blank Screen ..................................................................................175
7.8 Contacting Black Box.....................................................................175
7.9 Shipping and Packaging ................................................................176
Appendix. Glossary .....................................................................................177
Page 10
724-746-5500 | blackbox.com
Chapter 1: Specifications
1. Specifications
1.1 Interfaces
1.1.1 DVI-D Single Link
The video interface supports the DVI-D protocol. All signals that comply with DVI-D single-link standard can be transmitted. This includes, for example, monitor
resolutions such as 1920 x 1200 @ 60 Hz, Full HD (1080p), or 2K HD (up to 2048
x 1152). Data rate is limited to 165 MPixel/s.
1.1.2 USB HID
Devices with USB HID interface support a maximum of two devices with USB HID protocol. Each USB HID port provides a maximum current of 100 mA.
Keyboard
Compatible with most USB keyboards. Certain keyboards with additional functions may require custom firmware to operate. Keyboards with an integral USB Hub (Mac® keyboards, for example) are also supported.
Mouse
Compatible with most 2-button, 3-button, and scroll mice.
Other USB HID devices
The proprietary USB emulation also supports certain other USB HID devices, such as specific touchscreens, graphics tablets, bar-code scanners, or special keyboards. Support cannot be guaranteed, however, for every USB HID device.
NOTE: Only two USB HID devices are supported concurrently, such as keyboard
and mouse or keyboard and touchscreen. A hub is allowed, but it does not increase the number of HID devices allowed.
To support other USB “non-HID” devices, such as scanners, Web cams or memory devices, choose our devices with transparent USB support.
1.1.3 RJ-45 (Network)
CATx device communication requires a 1000BASE-T connection. Pin the cable according to EIA/TIA-568-B (1000BASE-T) standard with RJ-45 connectors at both ends. All four wire pairs are used in both directions. The cabling is suitable for full-duplex operation. For the cable connection to a source (computer, CPU), use a cross-pinned network cable.
724-746-5500 | blackbox.com
Page 11
Chapter 1: Specifications
1.1.4 RS-232 (Serial)
The communication takes place with a transmission speed of up to 115.2 kbps, regardless of the file format, eight data bits and a stop bit, but without a parity bit. Limited hardware handshake (DSR) is possible.
1.1.5 RJ-45 (Interconnect)
CATx device communication requires a 1000BASE-T connection.
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ-45 connectors at both ends. All four wire pairs are used.
1.1.6 Fiber SFP Type LC (Interconnect)
Fiber device communication is performed via Gigabit SFPs connected to suitable fibers fitted with LC connectors (see Section 1.2.2).
NOTE: The correct function of the device can only be guaranteed with SFPs
provided by Black Box.
CAUTION: SFP modules can be damaged by electrostatic discharge (ESD). Follow
ESD handling precautions.
1.1.7 SDI (Interconnect)
SDI device communication requires a mini coax connection with mini BNC connectors or 3G SFPs with transmission speeds of 0.360 Gbps (SD-SDI, SMPTE 259M), 1.485 Gbps (HD-SDI, SMPTE 292M), and 2.70 Gbps (3G SDI).
1.2 Interconnect Cable
1.2.1 CATx
NOTE: A point-to-point connection is required. Operation with several patch fields
is possible. Routing over an active network component, such as an Ethernet hub, router, or ServSwitch DKM FX, is not allowed.
• Avoid routing CATx cables along power cables.
• If the site has three-phase AC power, make sure that the CPU Unit and
CON Unit are on the same phase.
NOTE: To maintain regulatory EMC compliance, use correctly installed shielded
CATx cable throughout the interconnection link.
NOTE: To maintain regulatory EMC compliance, all CATx cables need to carry
ferrites on both cable ends close to the device.
Type of Interconnect Cable
The ServSwitch DKM FX requires interconnect cabling specified for Gigabit Ethernet (1000BASE-T). Use solid-core (24 AWG), shielded, CAT5e (or better) cable.
Page 12
724-746-5500 | blackbox.com
Table 1-1. CATx interconnect cable.
Cable Type Description
CATx solid-core 24 AWG cable
This S/UTP (CAT5e) cable confoms to EIA/TIA-568-B. Uses four pairs of 24 AWG wires. Connects according to EIA/TIA-568-B (1000BASE-T).
Chapter 1: Specifications
CATx solid-core 26/8 AWG cable
This S/UTP (CAT5e) cable confoms to EIA/TIA-568-B. Uses four pairs of 26/8 AWG wires. Connects according to EIA/TIA-568-B (1000BASE-T).
NOTE: You can use use type 26/8 AWG flexible cables (patch cables), but the
maximum possible extension distance is cut in half.
Table 1-2. Maximum acceptable cable length.
Cable Type Distance
CATx 24 AWG installation cable 400 ft. (140 m)
CATx 26/8 AWG patch cable 200 ft. (70 m)
1.2.2 Fiber
NOTE: A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as Ethernet hubs, ServSwitch DKM FXes, or routers, is not allowed.
Type of Interconnect Cable
Table 1-3. Fiber interconnect cable.
Cable Type Description
Single-mode, 9-µm
Multimode 50-µm
Multimode 62.5-µm
• Two fibers, 9-µm
• In-house patch cable (EFN092)
• Two fibers, 50-µm
• In-house patch cable (EFN6020)
• Two fibers, 62.5- µm
• In-house patch cable (EFN116 -LCLC)
NOTE: Only use single-mode cables for fiber connections that are based on 3G
SFPs.
724-746-5500 | blackbox.com
Page 13
Chapter 1: Specifications
Table 1-4. Maximum acceptable fiber cable length.
Cable Type Distance
Single-mode 9-µm 32,800 ft. (10,00 0 m)
Multimode 50-µm ( OM3) 3280 ft. (1000 m)
Multimode 50-µm 1300 ft. (400 m)
Multimode 62.5µm 650 ft. (200 m)
NOTE: If you use single-mode SFPs with multimode fiber optic cable, you can
double the maximum acceptable cable length.
Type of Connector
The fiber cable uses LC connectors.
1.2.3 Coaxial
NOTE: A point-to-point connection is necessary.
Table 1-5. Coaxial interconnect cable.
Cable Type Description
Mini coaxial cable, 18 AWG
RG-6 Impedance: 75 ohms
Table 1-6. Maximum acceptable coaxial cable length.
Bandwidth Distance
0.270 Gbps 1312 ft. (400 m)
1.4 85 Gbp s 459 ft. (140 m)
2.970 Gbps 394 ft. (120 m)
Type of Connector
The coaxial cable uses mini BNC connectors.
Page 14
724-746-5500 | blackbox.com
Chapter 1: Specifications
1.3 Supported Peripherals
You can use the KVM extenders described in Tables 1-7 and 1-8 with the ServSwitch DKM FX:
Table 1-7. KVM extender with CATx connection.
Produc t Code Description
AC X1 T-11 -C KVM CPU unit, single-head, 2x USB HID
ACX1R -11-C KVM CON unit, single -head, 2x USB HID
AC X1 T-11V - C KVM CPU unit, single-head, DVI-I input (VGA), 2x USB HID
ACX1R -11V-C KVM CON unit, single-head, IR receiver, 2x USB HID
Table 1-8. KVM extender with fiber (single-mode) connection.
Produc t Code Description
AC X1 T-11 -SM KVM CPU unit, single -head, 2x USB HID
ACX1R -11-SM KVM CON unit, single-head, 2x USB HID
AC X1 T-11V -S M KVM CPU unit, single-head, DVI-I input (VGA), 2x USB HID
ACX1R -11V-SM KVM CON unit, single-head, IR receiver, 2x USB HID
1.4 Connector Pinouts
1.4.1 CPU Board
Figure 1-1. DVI-D single-link connector.
724-746-5500 | blackbox.com
Page 15
Chapter 1: Specifications
Table 1-9. DVI-D single-link connector pinout.
Pin Signal Pin Signal Pin Signal
1 T.M.D.S. data 2- 9 T.M.D.S. data 1- 17 T.M.D.S. data 0-
2 T.M.D.S. data 2+ 10 T.M.D.S. data 1+ 18 T.M.D.S. data 0+
3 T.M.D.S. data 2 GND 11 T.M.D.S. data 1 GND 19 T.M.D.S. data 0 GND
4 Not connnected 12 Not connected 20 Not connected
5 Not connected 13 Not connected 21 Not connected
6 DDC input ( SCL) 14 +5 VDC high impedance 22 T.M.D.S. GND
7 DDC output (SDA) 15 GND 23 T.M.D.S. clock+
8 Internal use 16 Hot plug recognition 24 T.M.D.S. clock-
C1 Internal use C3 Internal use
C2 Not connected C5 GND C4 Internal use
Table 1-10. USB Type A connector.
Picture Pin Signal Color
1 VCC (+5 VDC) Red
2 Data - White
3 Data + Green
4 GND Black
Page 16
Table 1-11. DB9 connector.
Picture Pin Signal Color Signal
1 Not connected 6 DTR
2 CTS 7 TxD
3 RTS 8 RxD
4 DSR 9 Not connected
5 GND
724-746-5500 | blackbox.com
Picture Pin Signal Color Signal
1.4.2 I/O Board CATx
Picture Pin Signal Color Signal
1.4.3 I/O Board SFP
Chapter 1: Specifications
Table 1-12. RJ-45 connector.
1 D1+ 5 Not connected
2 D1- 6 D2-
3 D2+ 7 Not connected
4 Not connected 8 Not connected
Table 1-13. RJ-45 CATx connector.
1 D1+ 5 D3-
2 D1- 6 D2-
3 D2+ 7 D4+
4 D3 + 8 D4-
Table 1-14. RJ-45 connector.
Picture Diode Signal
1.4.4 I/O Board SDI
724-746-5500 | blackbox.com
1 Data OUT
2 Data IN
Table 1-15. RJ-45 connector.
Picture Pin Signal
1 Data In
2 GND
Page 17
Chapter 1: Specifications
1.5 Power Supply
Power — ACXC48, ACXC32, ACXC16: 90–240 VAC, 50–60 Hz internal power
supply; All other models: Voltage: 100–240 VAC, 50–60 Hz; ACX288, ACX288-PS: 202 W max. without I/O boards; ACX160, ACX160-PS: 188 W max. without I/O boards; ACX080, ACX080-PS: 99 W max. without I/O boards; ACX048: 94 W max. without I/O boards; I/O boards (ACXI08-C, ACXI08-SM, ACXI08-SPF): 13 W max.
1.6 Environmental Conditions
Temperature Tolerance — +41 to +113° F (+5 to +45° C)
Storage Temperature — -13 to +140° F (-25 to +60° C)
Relative Humidity — Max. 80%, non-condensing
1.7 Size
Size — ACX288: 19"H x 22.8"W x 12"D (48.3 x 57.8 x 33 cm),
Shipping box: 25.6"H x 26.8"W x 29.9"D (65 x 68 x 76 cm); ACX160: 19"H x 15.8"W x 12"D (48.3 x 40 x 33 cm), Shipping box: 25.6"H x 26.8"W x 12"D (65 x 68 x 54 cm); ACX080: 19"H x 7"W x 9.1"D (64 x 57 x 36 cm), Shipping box: 25.2"H x 22.4"W x 21.3"D (64 x 57 x 36 cm); ACX048: 19"H x 5.3"W x 9.1"D, Shipping box: 25.2" x 22.4"W x 12.4"D (64 x 57 x 23.1 cm); ACXC48, ACXC32, ACXC16: 1.7"H x 17.4"W x 16.9"D (4.4 x 44.4 x 42.9 cm)
1.8 Shipping Weight
Weight — ACX288: 76.2 lb (34.6 kg) fully equipped,
Shipping box: 90.6 lb. (41.1 kg); ACX160: 60 lb. (26.3 kg) fully equipped, Shipping box: 69.9 lb. (31.7 kg); ACX080: 24.5 lb. (11.1 kg) fully equipped, Shipping box: 34.4 lb. (15.6 kg); ACX048: 19.6 lb. (8.9 kg), Shipping box: 26.7 lb. (12.1 kg) ACXC48: 9 lb. (4.1 kg); ACXC32: 8.8 lb. (4 kg); ACXC16: 8.6 lb. (3.9 kg)
Page 18
724-746-5500 | blackbox.com
Chapter 2: Overview
2. Overview
2.1 Description
2.1.1 Ap plic ation
The ServSwitch DKM FX is used to establish connections from consoles (monitor, keyboard, mouse, and other peripheral devices) to various sources (computer, CPU). In a maximum configuration, up to 288 independent ports can be defined and switched either as a console or a CPU.
The ServSwitch DKM FX Compact is used to establish connections from consoles (monitor, keyboard, mouse, and other peripheral devices) to various sources (computer, CPU). In a maximum configuration, up to 16 (using the ACXC16), 32 (using the ACXC32), or 48 (using the ACXC48) independent ports can be defined and switched either as a console or a CPU.
The ServSwitch DKM FX is mainly specified for the use with extenders that are able to transmit video, KVM, and USB 2.0 signals. You can also use it as a video matrix.
For the connection between the ServSwitch DKM FX and the peripheral devices, such as KVM extenders or video sources, you can use CATx, fiber, or coaxial cables.
The ServSwitch DKM FX serves as a repeater. You can place it up to 6.2 miles (10 km) from the consoles and 6.2 miles (10 km) from the sources.
2.1.2 Access Options
You have the following options to access the ServSwitch DKM FX for configuration and operation:
Table 2-1. Access options.
Access option Symbol
OSD
Java tool
Serial interface
724-746-5500 | blackbox.com
Page 19
Chapter 2: Overview
2.2 System Overview
A ServSwitch DKM FX system consists of a ServSwitch DKM FX or DKM FX Compact and, for KVM applications, one or more CPU units/CON units. The ServSwitch connects to the CPU units/CON units by interconnect cables or is con­nected directly to the video devices when used as a video matrix.
The CPU units connect directly to the sources (computer, CPU), using the included cables.
Monitor(s), keyboard, and mouse connect to the CON units.
The ServSwitch DKM FX and the CPU units/CON units communicate over CATx, fiber, or coaxial interconnect cables. The ServSwitch DKM FX Compact and the CPU units/CON units communicate over CATx cable.
Figure 2-1 shows the system overview. Table 2-2 describes its components.
1 2 3 4 3 5 6
Figure 2-1. System overview.
Table 2-2. System components.
Number Component
1 Source (computer, CPU)
2 CPU units
3 Interconnect cable
4 ServSwitch DKM FX
5 CON units
6 Console (monitor, keyboard, mouse)
Page 20
724-746-5500 | blackbox.com
See Section 3.2 for installation examples.
2.3 Available Products
Table 2-3. Available products.
Number Description
Serv Switch DKM FX
ACX04 8 ServSwitch DKM FX 48-port with control card and power supply
ACX080 ServSwitch DKM FX 80-port with control card and power supply
ACX16 0 ServSwitch DKM F X 160-port with control card and power supply
ACX288 ServSwitch DKM FX 288-port with control card and power supply
Serv Switch DKM FX Compact
ACXC16 ServSwitch DKM FX Compact 16-port
ACXC32 ServSwitch DKM FX Compact 32-port
ACXC4 8 ServSwitch DKM FX Compact 48-port
Accessories
ACXIO8- C 8-port CATx input/output (I /O) module
ACXI O8-SM 8-port single-mode fiber input/output (I /O ) module
ACXI O8-SFP 8-por t single-mode fiber SFP input/output (I / O) module
ACX288-CTL ServSwitch DKM F X controller card
ACXSFPC CATx SFP module
ACXSFPS Single-mode fiber SFP module
ACX080-PS Power supply for ACX04 8 and ACX080
ACX16 0-P S Power supply for ACX160
ACX288-PS Power supply for ACX288
ACX080-FAN Tray for 48 /80 port console
ACX288-FAN Tray for 160/288 port console
ACX-JAV DKM F X Java Switch and Preset License
ACX-SYS DKM FX SNMP Switch and Syslog License
ACX-CAS DKM FX Cascade License
ACX-API DKM FX API License
Chapter 2: Overview
2.4 What’s Included
Your package should contain the following items. If anything is missing or damaged, contact Black Box Technical Support at 724-746-5500
or info@blackbox.com.
724-746-5500 | blackbox.com
Page 21
Chapter 2: Overview
ACX048, ACX80 ACX160, ACX288:
• (1) ServSwitch DKM FX (ACX048, ACX080, ACX160, or ACX288)
• (1) power cord per built-in power supply unit
• (1) DKM FX controller card
• (1) serial control cable
• (1) set of mounting accessories
• This users’ manual in PDF format and Java tool on CD-ROM
• (1) cross-wired CATx network cable
ACXC16, ACXC32, ACXC48:
• (1) ServSwitch DKM FX Compact (ACXC16, ACXC32, or ACXC48)
• (2) U.S. power cords (one per built-in power supply unit)
• (2) mounting brackets
• (1) RJ-45/DB9 adapter
• (4) rubber feet
• This users’ manual in PDF format and Java tool on CD-ROM
Page 22
724-746-5500 | blackbox.com
Chapter 2: Overview
2.5 Device Views
In Sections 2.5.1 through 2.5.4, Figures 2-2 through 2-5 illustrate the ServSwitch DKM FX chassis models. Tables 2-4 through 2-7 describe their components.
2.5.1 ServSwitch DKM FX 288-Port
1 2 3 4 5 6 7 8
Figure 2-2. Front view, ACX288.
724-746-5500 | blackbox.com
Page 23
Chapter 2: Overview
Table 2-4. ACX288 components.
Number Component
1 Slot for Power Supply Unit 1
2 Slot for Fan Tray 1
3 Slot for Power Supply Unit 2
4 Slot for Fan Tray 2
5 Slot for I/ O Boards 1–36
6 Slot for Power Supply Unit 3
7 Slot for CPU board
8 Grounding
2.5.2 ServSwitch DKM FX 160-Port
Page 24
1 2 3 4 5 6 7 8
Figure 2-3. Front view, ACX160.
724-746-5500 | blackbox.com
Table 2-5. ACX160 components.
Number Component
1 Slot for Power Supply Unit 1
2 Slot for Fan Tray 1
3 Slot for Power Supply Unit 2
4 Slot for Fan Tray 2
5 Slot for I/ O Boards 1–36
6 Slot for Power Supply Unit 3
7 Slot for CPU board
8 Grounding
2.5.3 ServSwitch DKM FX 80-Port
Chapter 2: Overview
1 2 3 4 5 6 7
Figure 2-4. Front view, ACX080.
Table 2-6. ACX080 components.
Number Component
1 Slot for fan tray
2 Slot for Power Supply Unit 1
3 Slot for I/ O Boards 1–10
4 Slot for Power Supply Unit 2
5 Slot for CPU board
6 Slot for air filter
7 Slot for Fan Tray 2
724-746-5500 | blackbox.com
Page 25
Chapter 2: Overview
2.5.4 ServSwitch DKM FX 48-Port
1 2 3 4 5 6 7
Figure 2-5. Front view, ACX048.
Table 2-7. ACX048 components.
Number Component
1 Slot for fan tray
2 Slot for Power Supply Unit 1
3 Slot for I/ O Boards 1–10
4 Slot for Power Supply Unit 2
5 Slot for CPU board
6 Slot for air filter
7 Slot for Fan Tray 2
In Sections 2.5.5 through 2.5.7, Figures 2-6 through 2-11 illustrate the ServSwitch DKM FX Compact models. Tables 2-8 through 2-13 describe their components.
2.5.5 ServSwitch DKM FX Compact 48-Port
1 2 3 4 5
Figure 2-6. Front view, ACXC48.
Page 26
724-746-5500 | blackbox.com
Table 2-8. ACXC48 front-panel
components.
Number Component
1 I/ O ports 1–16
2 I/ O ports 17–32
3 I/ O ports 33–48
4 Serial connection (RJ-45)
5 Network connection (RJ-45)
1 2 3
Figure 2-7. Back view, ACXC48.
Chapter 2: Overview
Table 2-9. ACXC48 back-panel
components.
Number Component
1 Power supply unit 1
2 Power supply unit 2
3 Grounding
724-746-5500 | blackbox.com
Page 27
Chapter 2: Overview
2.5.6 ServSwitch DKM FX Compact 32-Port
1 2 3 4
Figure 2-8. Front view, ACXC32.
Table 2-10. ACXC32 components.
Number Component
1 I/ O ports 1–16
2 I/ O ports 17–32
3 Serial connection (RJ-45)
4 Network connection (RJ-45)
Page 28
1 2 3
Figure 2-9. Back view, ACXC32.
Table 2-11. ACXC32 back-panel components.
Number Component
1 Power supply unit 1
2 Power supply unit 2
3 Grounding
724-746-5500 | blackbox.com
2.5.7 ServSwitch DKM FX Compact 16-Port
1 2 3
Figure 2-10. Front view, ACXC16.
Table 2-12. ACXC16 components.
Number Component
1 I/ O ports 1–16
2 Serial connection (RJ-45)
3 Network connection (RJ-45)
Chapter 2: Overview
1 2 3
Figure 2-11. Back view, ACXC16.
Table 2-13. ACXC16 back-panel components.
Number Component
1 Power supply unit 1
2 Power supply unit 2
3 Grounding
724-746-5500 | blackbox.com
Page 29
Chapter 2: Overview
2.6 Diagnostics and Status
2.6.1 Status LEDs
The ServSwitch DKM FX and DKM FX Compact LED indicators are shown in Figures 2-12 through 2-22, and described in Tables 2-14 through 2-25.
1
Page 30
2
Figure 2-12. CPU board, front view.
724-746-5500 | blackbox.com
Loading...