1.1 In te r faces .................................................................................................................................................................................................. 5
1.1.1 R J -4 5 (Inte r c onnect) ..........................................................................................................................................................................................5
1.1.2 Fiber SFP Type LC (Interconnect) ....................................................................................................................................................................5
1.2 .1 C ATx .......................................................................................................................................................................................................................5
1.4 Power Supply ............................................................................................................................................................................................ 8
2.2 System Overview .................................................................................................................................................................................... 11
2.3 Product Range ........................................................................................................................................................................................ 12
2.5.1 2-Slot Chassis with One External Power Supply Unit (ACXMODH2-R2) ........................................................................................... 14
2.5.2 2-Slot Chassis with One External Power Supply Unit and Redundant Power Option (ACXMODH2R-R2) ................................. 15
2.5.3 2-Slot Chassis with One Internal Power Supply Unit and Redundant Power Option (ACXMODH2R-P-R2) ............................... 16
2.5.4 4-Slot Chassis with One External Power Supply Unit (ACXMODH4-R2) ........................................................................................... 17
2.5.5 4-Slot Chassis with One External Power Supply Unit and Redundant Power Option (ACXMODH4R-R2) ................................. 18
2.5.6 6-Slot Chassis with One Internal Power Supply and Redundant Power Option (ACXMODH6R-R2) ........................................... 19
2.5.7 6 -Slot Chassis with Active Backplane and Two Internal Power Supplies (ACXMODH6BPAC-R2) .............................................20
2.5.8 6-Slot Chassis with Active Backplane and Two Internal Power Supplies and Connectors
on the Back Side (ACXMOD6FPAC-R2) ...................................................................................................................................................21
2.5.9 21-Slot Chassis with One Internal Power Supply and Redundant Power Option (ACXMODH21R)..............................................22
2.6 Status LEDs ............................................................................................................................................................................................26
2.6.1 Status (Cross) Repeater Module ................................................................................................................................................................... 26
3.2 System Installation ................................................................................................................................................................................27
3.3 Example Applications ............................................................................................................................................................................28
5. CONTACTING BLACK BOX TECHNICAL SUPPORT .................................................................................................................. 31
51 Support Checklist ....................................................................................................................................................................................31
APPENDIX A. REGULATORY INFORMATION ................................................................................................................................ 32
A.1 CE Declaration of Conformity ...............................................................................................................................................................32
A.6 NOM Statement .....................................................................................................................................................................................33
APPENDIX B. GLOSSARY ............................................................................................................................................................... 34
APPENDIX C. DISCLAIMER/TRADEMARKS ................................................................................................................................. 36
C.2 Trademarks Used in this Manual .......................................................................................................................................................... 36
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
3
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
SAFETY INSTRUCTIONS
To ensure reliable and safe long-term operation of your Repeater please note the following guidelines.
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
INSTALLATION
Only use in dry, indoor environments.
The Repeater and the power supply units can get warm. Do not install components in an enclosed space without any airflow.
Do not place the power supply directly on top of the device.
Do not obscure ventilation holes.
Only use power supplies originally supplied with the product or manufacturer-approved replacements. Do not use a power supply if
it appears to be defective or has a damaged chassis.
Connect all power supplies to grounded outlets. In each case, ensure that the ground connection is maintained from the outlet
socket through to the power supply’s AC power input.
Do not connect the link interface to any other equipment, particularly network or telecommunications equipment.
Take any required ESD precautions.
NOTE: To disconnect the device completely from the electric circuit, all power cables have to be removed.
REPAIR
Do not attempt to open or repair a power supply unit.
Do not attempt to open or repair the Repeater. There are no user serviceable parts inside.
Please contact Black Box Technical Support at 877-877-2269 or info@blackbox.com if there is a fault.
4
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
CHAPTER 1: SPECIFICATIONS
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
1.1 INTERFAC ES
1.1.1 RJ-45 (INTERCONNECT)
For CATx communications, the repeater requires a 1000BASE-T connection.
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ-45 connectors at both ends. All four cable wire pairs
are used.
1.1.2 FIBER SFP TYPE LC (INTERCONNECT)
The communication of fiber devices is performed via Gigabit SFPs that have to be connected to suitable fibers fitted with type LC
connectors.
NOTE: The correct function of the device can only be guaranteed with SFPs provided by Black Box.
CAUTION: SFP modules can be damaged by electrostatic discharge (ESD). When handling, take care not to damage devices.
1.2 INTERCONNECT CABLE
1. 2.1 C AT X
NOTE: A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component,
such as an Ethernet hub, router, or switch, is not allowed.
Avoid routing CATx cables along power cables.
If the site has 3-phase AC power, make sure that the CPU module and CON module are on the same phase.
CAUTION: To maintain regulatory EMC compliance, you must use correctly installed shielded CATx cable throughout the interconnection
link. Also, all CATx cables need to have ferrites on both cable ends close to the device.
TYPE OF INTERCONNECT CABLE
The (Cross) Repeater requires interconnect cabling specified for Gigabit Ethernet (1000BASE-T). The use of solid-core (24 AWG), shielded,
CAT5e (or better) is recommended.
TABLE 1-1. CATX INTERCONNECT CABLE
CABLE TYPEDESCRIPTION
CATx solid-core cable 24 AWG
CATx patch cable 26/8 AWG
S/UTP (CAT5e) cable according to EIA/TIA-568-B. Four pairs of 24 AWG wires. Connection according
to EIA/TIA-568-B (1000BASE-T).
S/UTP (CAT5e) cable according to EIA/TIA-568-B. Four pairs of 26/8 AWG wires. Connection according
to EIA/TIA-568-B (1000BASE-T).
NOTE: You can use flexible cables (patch cables) type 26/8 AWG; however, but you’ll only get half the maximum possible extension distance
(Table 1- 2).
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
5
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
CHAPTER 1: SPECIFICATIONS
TABLE 1-2. MAXIMUM ACCEPTABLE CATX CABLE LENGTH
CABLE TYPEMAXIMUM LENGTH
Solid-conductor 24 AWG CATx cable400 feet (140 m)
Stranded-conductor 26/28 or 27/28 AWG or CATx cable200 feet (70 m)
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
1.2.2 FIBER
NOTE: A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over active network components,
such as Ethernet hubs, switches, or routers, is not allowed.
TABLE 1-3. FIBER INTERCONNECT CABLE
CABLE TYPEDESCRIPTION
Single-mode fiber 9 µm
Multimode fiber 50 µm
Multimode fiber 62 µm
• Duplex.
• Indoor patch cable (EFN092)
• Duplex.
• Indoor patch cable (EFN6020)
• Duplex.
• Indoor patch cable (EFN116-LCLC)
TABLE 1-4. MAXIMUM ACCEPTABLE FIBER CABLE LENGTH
CABLE TYPEMAXIMUM LENGTH
Single-mode fiber 9 µm32,800 feet (10,000 m)
Multimode fiber 50 µm (OM3)3280 feet (1000 m)
Multimode fiber 50 µm1300 feet (400 m)
Multimode fiber 62.5 µm650 feet (200 m)
NOTE: If you use single-mode SFPs with multimode fibers, you can normally double the maximum acceptable cable length.
CONNECTOR TYPE
The ACX1M-CS, ACX1M-SS, ACX1M-2C2S, and ACX1M-2S2S have fiber LC connectors.
6
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
CHAPTER 1: SPECIFICATIONS
1.3 CONNECTOR PINOUTS
TABLE 1-5. MINI USB TYPE B CONNECTOR PINOUT
PICTUREPIN SIGNALCOLOR
1 VCC (+5 VDC)Red
2 Data -White
3 Data +Green
PICTUREPIN SIGNALPIN SIGNAL
4 Not connected—
5 GroundBlack
TABLE 1-6. RJ-45 CONNECTOR PINOUT
1 D1+5 D3-
2 D1-6 D2-
3 D2+7 D4+
4 D3+8 D4-
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
TABLE 1-7. FIBER SFP TYPE LC CONNECTOR PINOUT
PICTUREPIN SIGNAL
Data OUT
1
Data IN
2
TABLE 1-8. CONNECTORS ON THE REPEATERS/CROSS REPEATERS
PART NUMBERCONNECTORS
ACX1M-CC(2) RJ-45 interconnect, (1) Mini USB (programming port)
ACX1M-SS(2) Fiber LC, (1) Mini USB (programming port)
ACX1M-CS(1) RJ-45, (1) Fiber LC, (1) Mini USB (programming port)
ACX1M-2C2C(4) RJ-45, (2) Mini USB (programming ports)
ACX1M-2S2S(4) Fiber LC, (2) Mini USB (programming ports);
ACX1M-2C2S(2) RJ-45, (2) Fiber LC, (2) Mini USB (programming ports)
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
7
CHAPTER 1: SPECIFICATIONS
1.4 POWER SUPPLY
TABLE 1-9. AC POWER SUPPLY
PART NUMBERMAX. CURRENTMAX. VO LTAGEFREQUENCY
ACXMODH2R-P-R2700 mA max.100 to 240 VAC50/60 Hz
ACXMODH6R-R21400 mA max100 to 240 VAC47 to 63 Hz
ACXMODH6BPAC-R2800 mA max.100 to 240 VAC50/60 Hz
ACXMODH6FPAC-R2800 mA max.100 to 240 VAC50/60 Hz
ACXMODH21R4000 mA max.(2) 100 to 240 VAC50/60 Hz
TABLE 1-10. DC POWER SUPPLY
PART NUMBERMAX. CURRENTMAX. VO LTAGEFREQUENCY
ACXMODH2-R23000 mA max.5 VDC50/60 Hz
ACXMODH2R-R23000 mA max5 VDC47 to 63 Hz
ACXMODH2R-P-R25000 mA max.5 VDC50/60 Hz
ACXMODH4-R25000 mA max.5 VDC50/60 Hz
ACXMODH4R-R25000 mA max.5 VDC50/60 Hz
ACXMODH6R-R28000 mA max.5 VDC50/60 Hz
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
NOTE: The power requirement per (cross) repeater is 300 mA max.
1.5 ENVIRONMENTAL CONDITIONS
TABLE 1-11. ENVIRONMENTAL SPECIFICATIONS
SPECIFICATIONDESCRIPTION
Operating Temperature41 to 113° F (5 to 45°C)
Storage Temperature-13 to +140° F (-25 to +60° C)
Relative HumidityMax.80%, noncondensing
8
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
CHAPTER 1: SPECIFICATIONS
1.6 DIMENSIONS
TABLE 1-12. DKM FX MODULAR REPEATERS
ITEMDIMENSIONS
Repeater/Cross Repeater1.7”H x 5.81”W x 5.75”D (4.3 x 14.8 x 14.6 cm)
TABLE 1-13. DEVICES IN THE 2-SLOT CHASSIS (ACXMODH2-R2)
ITEMDIMENSIONS
CPU Unit/CON Unit1.7"H x 5.8" W x 5.7"D (4.1 x 14.7 x 14.5 cm)
Shipping Box6.5"H x 5.5"W x 8.3"H (16.5 x 14 x 21 cm)
TABLE 1-14. DEVICES IN THE 2-SLOT CHASSIS (ACXMODH2R-R2, ACXMODH2R-P-R2)
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
ITEMDIMENSIONS
CPU Unit/CON Unit1.7"H x 5.8" W x 8.3"D (4.1 x 14.7 x 22.1 cm)
Shipping Box4.5"H x 14.4"W x 21.7"D (11.5 x 36.5 x 55 cm)
TABLE 1-15. DEVICES IN THE 4-SLOT CHASSIS (ACXMODH4-R2, ACXMODH4R-R2)
ITEMDIMENSIONS
CPU Unit/CON Unit1.7"H x 5.8" W x 11.5"D (4.1 x 14.7 x 29.3 cm)
Shipping Box4.5"H x 14.4"W x 21.7"D (11.5 x 36.5 x 55 cm)
TABLE 1-16. DEVICES IN THE 6-SLOT CHASSIS (ACXMODH6R-R2)
ITEMDIMENSIONS
CPU Unit/CON Unit1.7"H x 5.8" W x 17.4"D (4.1 x 14.7 x 44.2 cm)
Shipping Box4.5"H x 14.4"W x 29.9"D (11.5 x 36.5 x 76 cm)
TABLE 1-17. DEVICES IN THE 6-SLOT CHASSIS (ACXMODH6BPAC-R2, ACXMOD6FPAC-R2)
ITEMDIMENSIONS
CPU Unit/CON Unit1.7"H x 9.8"W x 17.4"D (4.1 x 25 x 44.2 cm)
Shipping Box6.1"H x 14.6"W x 21.7"D (15.5 x 37.2 x 55 cm)
TABLE 1-18. DEVICES IN THE 21-SLOT CHASSIS (ACXMODH21R)
ITEMDIMENSIONS
CPU Unit/CON Unit6.9"H x 18.2"W x 19"D (17.6 x 46.2 x 48.2 cm)
Shipping Box14.5"H x 22.6"W x 25.4"D (36.8 x 57.4 x 64.5 cm)
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
9
CHAPTER 1: SPECIFICATIONS
1.7 SHIPPING WEIGHT
TABLE 1-19. DKM FX MODULAR REPEATERS
ITEMDIMENSIONS
Repeater/Cross Repeater0.6 lb. (0.3 kg)
Shipping Box4.9 lb. (2.2 kg)
TABLE 1-20. DEVICES IN THE 2-SLOT CHASSIS (ACXMODH2-R2)
ITEMSHIPPING WEIGHT
CPU Unit/CON Unit0.9 lb. (0.4 kg)
Shipping Box4.9 lb. (2.2 kg)
TABLE 1-21. DEVICES IN THE 2-SLOT CHASSIS (ACXMODH2R-R2, ACXMODH2R-P-R2)
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
ITEMSHIPPING WEIGHT
CPU Unit/CON Unit1.8 lb. (0.8 kg)
Shipping Box5.7 lb. (2.6 kg)
TABLE 1-22. DEVICES IN THE 4-SLOT CHASSIS (ACXMODH4-R2, ACXMODH4R-R2)
ITEMSHIPPING WEIGHT
CPU Unit/CON Unit2.0 lb. (0.9 kg)
Shipping Box7.5 lb. (3.4 kg)
TABLE 1-23. DEVICES IN THE 6-SLOT CHASSIS (ACXMODH6R-R2)
ITEMSHIPPING WEIGHT
CPU Unit/CON Unit3.1 lb. (1.4 kg)
Shipping Box10.1 lb. (4.6 kg)
TABLE 1-24. DEVICES IN THE 6-SLOT CHASSIS (ACXMODH6BPAC-R2, ACXMOD6FPAC-R2)
ITEMSHIPPING WEIGHT
CPU Unit/CON Unit5.5 lb. (2.5 kg)
Shipping Box7.7 lb. (3.5 kg)
TABLE 1-25. DEVICES IN THE 21-SLOT CHASSIS (ACXMODH21R)
ITEMSHIPPING WEIGHT
CPU Unit/CON Unit22.1 lb. (10.0 kg)
Shipping Box32.0 lb. (14.5 kg)
10
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
CHAPTER 2: DESCRIPTION
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
2.1 APPLICATION
The (Cross) Repeater is used to double the maximum cabling distance between a KVM extender CON or CPU Unit or even a KVM
matrix. The device can also be used for media conversion from CATx to fiber or vice versa.
The device is available as a pure CATx or fiber version (repeater) and as a hybrid version of CATx and fiber (cross repeater) for an
additional electrical/optical signal conversion.
2.2 SYSTEM OVERVIEW
The (Cross) Repeater consists of at least one module depending on the application.
The device is connected between a KVM extender CON and CPU Unit via the interconnect cable or can be alternatively connected
between a KVM extender unit and a KVM matrix.
The (Cross) Repeater communicates with both the KVM extenders and a KVM-Matrix via the interconnect cables.
TABLE 2-1. SYSTEM COMPONENTS
NUMBER IN FIGURE 2-1COMPONENT
1Source (computer, CPU)
2KVM Extender CPU Unit
3Interconnect cable (CATx or fiber)
4(Cross) Repeater
5Interconnect cable (CATx or fiber)
6KVM Extender CON Unit
7Console (monitor, keyboard, mouse)
NOTE: See Chapter 3 for installation examples.
FIGURE 2-1. SYSTEM OVERVIEW
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
11
NEED HELP?
LEAV E THE TEC H TO US
LIVE 24/7
CHAPTER 2: DESCRIPTION
2.3 PRODUCT RANGE
TECHNICAL
SUPPORT
1. 8 7 7. 87 7. 2 269
2.3 .1 C H A S SI S
TABLE 2-2. AVAILABLE CHASSIS
PART NUMBERDESCRIPTION
ACXMODH2-R2Empty chassis for up to 2 boards, 1 external power supply unit
ACXMODH2R-R2
ACXMODH2R-P-R2
ACXMODH4-R2Empty chassis for up to 4 boards, 1 external power supply unit
ACXMODH4R-R2
ACXMODH6R-R2
ACXMODH6BPAC-R2Empty chassis for up to 6 boards, active backplane, 2 internal power supplies (redundancy)
ACXMODH6FPAC-R2Empty chassis for up to 6 boards, active backplane, 2 internal power supplies (redundancy) with connectors on rear side
ACXMODH21R
Empty chassis for up to 2 boards, 1 external power supply unit, preparation for redundancy for a second power supply
unit (external)
Empty chassis for up to 2 boards, 1 internal power supply unit, preparation for redundancy for a second power supply
unit (external)
Empty chassis for up to 4 boards, 1 external power supply unit, preparation for redundancy for a second power supply
unit (external)
Empty chassis for up to 6 boards, 1 internal power supply, preparation for redundancy for a second power supply unit
(external)
Empty chassis for up to 21 boards, 1 internal power supply unit, preparation for redundancy for a second power supply
unit (internal)
2.3.2 (CROSS) REPEATER MODULES
TABLE 2-3. AVAILABLE REPEATER MODULES
PART NUMBERDESCRIPTION
ACX1M-CCRepeater module CATx for range extension up to 896 ft. (280 m)
ACX1M-SSRepeater module fiber (Single-Mode) for range extension up to 12.4 mi. (20 km)
ACX1M-CS
ACX1M-2C2CDual Repeater module CATx for range extension up to 896 ft. (280 m)
ACX1M-2S2SDual Repeater module fiber (Single-Mode) for range extension up to 12.4 mi. (20 km)
ACX1M -2C2S
Cross Repeater module CATx/fiber (Single-Mode) for an electrical/optical media conversion, maximum extension
up to 6.3 mi. (10.14 km)
Dual Cross Repeater module CATx/fiber (Single-Mode) for an electrical/optical media conversion, maximum extension
up to 6.3 mi. (10.14 km)
12
1. 8 7 7. 8 7 7. 2 2 6 9BL ACK BOX .COM
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.