Black Box 10BASE-T Extender, LZ6000A-R4 User Manual

CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com
FEBRUARY 1999
10BASE-T Extender
Power
10BASE-T
Single UTP
10BASE-T Extender
Jabber
Link Test
Activity
Power
Collision
1
10BASE-T EXTENDER
FEDERAL COMMUNICATIONS COMMISSION
AND
INDUSTRY CANADA
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
2
10BASE-T EXTENDER
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El parato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
3
10BASE-T EXTENDER
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su
desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
4
10BASE-T EXTENDER
TRADEMARKS
The trademarks mentioned in this manual are the sole property of their owners.
5
10BASE-T EXTENDER
CONTENTS
1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 What’s Included in the Package . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Equipment Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1 Tools Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2 About the Wiring Closet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.3 UTP Phone Wire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.4 Patch Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.5 Straight-through Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.6 Preparing the Site Plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.7 Measuring Phone Wire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.8 Installing the Extenders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.9 Connecting the Extender to the Phone Block . . . . . . . . . . . . . . . . 16
3.10 Connecting the Extender to 10BASE-T . . . . . . . . . . . . . . . . . . . . 18
3.10.1 Connecting to a Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.10.2 Connecting to a Node (NIC) . . . . . . . . . . . . . . . . . . . . . . . 19
3.11 Starting the Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4. Monitoring and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.1 Monitoring the 10BASE-T Extender LEDs . . . . . . . . . . . . . . . . . . . 20
4.2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.2.1 Solving Common Extender Problems . . . . . . . . . . . . . . . . . 21
4.2.2 Collision Indicator is Lit Continuously. . . . . . . . . . . . . . . . . 21
4.2.3 Link is Not Lit on the Extender . . . . . . . . . . . . . . . . . . . . . . 21
6
10BASE-T EXTENDER
1. Specifications
Speed—10 Mbps
Standards—IEEE 802.3 Ethernet
Connectors—(1) RCA male, (2) RJ-45
Indicators—(5) LEDs: Power, Activity, Link Test, Jabber, Collision
Power—100-250 VAC, autosensing wallmount power supply, 47-63 Hz, 9 V at
1 Amp
Size—0.8”H x 2.7”W x 4.5”D (2 x 6.9 x 11.4 cm)
Weight—4 oz. (0.1 kg)
7
10BASE-T EXTENDER
2. Introduction
2.1 Overview
The 10BASE-T Extender is a high-performance Ethernet repeater that operates over a spare pair of telephone wires already in the walls or buried in the ground. It works with any IEEE 802.3 compatible Ethernet system.
2.2 What’s Included in the Package
Check to make sure that your LZ6000A-R4 kit contains the following items. If anything is missing or damaged, please call Black Box at 724-746-5500.
• (1) 10BASE-T Extender (part number LZ6000A-R3)
• (1) surge protector (part number SP512A-R2)
• (1) Velcro®strip for wall mounting
• (1) AC power supply, 100-250 VAC autosensing
• (1) North American power cord
2.3 Equipment Protection
You must be extremely careful to ensure the safety of persons and equipment whenever using wires that run between buildings. Both underground cable runs that are near the surface and overhead runs are at risk of damage from lightning strikes and must be suitably protected. This protection must be in place or there will be risk of serious injury or death. The service entrance at each end of the wires should be protected in strict accordance with local safety codes. In addition, to further reduce the risk of injury and/or damage to equipment due to lightning strikes or accidental connection to hazardous AC line voltages, secondary circuit protection, included with this product, must be installed.
Outdoor cabling installed by the phone company is typically installed with gas­discharge protection devices, carbon blocks, or no protection devices at all. If cabling has protection, DO NOT BYPASS these devices—they will help protect both your equipment and all those who work with it.
Loading...
+ 17 hidden pages