Introduction
This Quick Start Guide covers the key points of the installation for your Terminal Server product. It is intended for systems administrators familiar with operating systems covered.
The Terminal Server is a TCP/IP Terminal Server available in table top form. The table top unit has 2 or 4 RS-232/RS-422 ports that can be used for terminals, modems, printers or other serial devices. The serial ports are individually numbered.
Connectors and indicators
The functions of these are described in the User and Administration Guide supplied with this product.
Connecting up the unit and logging in from a remote host
1. Read the safety manu al supplied with this product.
2. Connect the unit to the ethernet.
3. Connect the power cable to the unit.
4. Power up the unit.
5. On a local ho st, for UNIX type:
arp -s a.b.c.d aa:bb:cc:dd:ee:ff
or for Windows type:
arp -s a.b.c.d aa-bb-cc-dd-ee-ff
replacing a.b.c.d with the unit IP address and aa:bb:cc:dd:ee:ff with the ethernet address.
6. From the comman d prompt, run: telnet a.b.c.d
(This may take a few seconds to complete).
7. At the password p rompt press Enter.
8. At the Local > prompt now displayed, type: set term for supported terminals and press Enter.
9. Type set term <terminal> and then press Enter for the appropriate terminal type.
You have now connected up and logged into the unit.
Setting the network parameters
1. Press CRTL A for the ADMINISTRATION MENU then press CRTL P.
2. At the password prom pt now displayed, type iolan as the default password and press Enter.
3. In the ad ministrator password window is now displayed, use the cursor keys to select Server then press Enter.
The server menu is now displayed.
4. Enter the IP address and h ost name for the unit. Press Enter twice to save the changes.
5. Select Reboot from the menu and press Enter.
6. Confirm Re boot and wait for the unit to restart.
Your unit is now set up for operation.
Setting up a printer
This section assumes your printer client is set up for LPD printing.
1. Power down the unit and attach the serial printer using a cable specified in the User and Administration Guide.
2. Power up the unit.
3. Log in an d select the Administration Mode (using CTRL A and then CTRL P).
4. Using the cursor keys select the Port option then e nter the number of the serial port you attached the printer to.
5. On the Port Setup Me nu, set the parameters in the Hardware and Flow ctrl to match those of your printer.
6. Enter the print queue filename in the User Name field. and then press Enter.
7. Set Access to Remote using the spacebar to select the appropriate action.
8. Set the Local Port field. This is a TCP Port number and for LPD this should be set to 515.
9. Press Enter twice to save the changes.
10.From the ADMINISTRATION MENU select the Kill option and enter the serial port number for the printer, then press Enter.
The port is now setup, you can now send a print job to the unit to test printing.
Serial ports
Port activity indicators
10/100 BASE-T socket
Network indicator
Power input socket
Power indicator
Front view
Rear view
Note These instructions assume the unit is attached to the same LAN
as other host machines. Refer to the User and Administration Guide for other situations. To perform the basic configuration you will need to know:
• The IP address of the unit
• The ethernet address of the unit
• The host name of the unit If in doubt please refer to your system administrator.
Notes: For setting up a unit via a serially attached terminal, refer to the
appropriate section in the User and Administration Guide. For setting up a unit via BOOTP, refer to the appropriate
section in the User and Administration Guide.
Remote access dial in modem setup
1. Power down the un it and attach the modem using a suitable cable.
2. Power up the unit.
3. Log in and select t he Administration Mode (using CTRL A and then CTRL P).
4. Using the cursor keys select the Port option then enter the number of the serial port you attached the printer to.
5. Setup Hardware with Mon itor DCD to yes and Flow Ctrl to match the modem. In the IP address fields, set Src (local end of PPP connection) and Dst (remote end) addresses.
6. Set Access to Local an d Authentication to Host if user has to be validated. Press Enter twice to save and exit.
7. On the ADMIN ISTRATION MENU select Access and press Enter. Now select Remote Site Devices and press Enter.
8. Select the entry from the Device type window where the listed items represent the ports (i.e. first item = port1, second item = port2, etc.), select the port you are attaching the modem to and press Enter.
9. In the REMOTE SITE DEVICES MENU now displayed. set the Inactivity timer to an appropriate value in minutes.
10.Set the Config field to the modem’s initialisation command string. Press Enter twice.
11.From the ADMINISTRATION MENU select Access.
12.In the Access pop-up wi ndow now displayed, select Authentication/Logging and press Enter.
13.In the host AUTHE NTICATION AND LOGGING menu now displayed, go to the Auth Host field enter the IP address of the authentication host.
14.Change the Success Indication String field and Failure Indication String field to suit your login sequence of your authentication hosts. Press Enter twice to save and exit.
15.In the ADMINISTRATION MENU, select kill and press Enter.
16.Enter the mo de m port number and press Enter.
Setup is now complete. A remote user should now attempt to log in.
102/104 Terminal Server
Quick start guide
Note: If the src is left blank it defaults to the IP address of the unit.
© Copyright 2002. Black Box Corporation. All rights reserved.
1000ParkDrive
∙Lawrence,PA1505510187247465500Fax7247460746
R1.2
May 2006 102 Terminal Server 41872-R3 104 Terminal Server 41874-R3
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 1055-1018 Web site: www.blackbox.com · E-mail info@blackbox.com
Loading...