B&K Precision 1280B User Manual

Model: 1280B
Benchtop Computer Monitor Generator
USER MANUAL
Safety Summary
Do not alter the ground connection. Without the protective ground connection, all accessible
bs) can render an electric shock. The power jack and mating
To avoid electrical shock hazard, disconnect power cord before removing covers. Refer servicing to
efore connecting the line cord to the AC mains, check the rear panel AC line voltage indicator.
Applying a line voltage other than the indicated voltage can destroy the AC line fuses. For continued
static discharge (ESD). To avoid
damage, be sure to follow proper procedures for handling, storing and transporting parts and
The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation, service, and repair of this instrument. Before applying power, follow the installation instructions and become famil ia r with the operating instructions for this instrument.
Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. B&K PRECISION assumes no liability for a customer’s failure to comply with these requirements. This is a Safety Class I instrument.
GROUND THE INSTRUMENT
To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. This instrument is grounded through the ground conductor of the supplied, three-conductor ac power cable. The power cable must be plugged into an approved three-conductor electrical outlet. Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including control knobs) can render an electric shock. The power jack and mating plug of the power cable meet IEC safety standards.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Instrument covers must not be removed by operating personnel. Component replacement and internal adjustments must be made by qualified maintenance personnel. Disconnect the power cord before removing the instrument covers and replacing components. Under certain conditions, even with the power cable removed, dangerous voltages may exist. To a void injuries, always disconnect power and discharge circuits before touching them.
DO NOT SERVICE OR ADJUST ALONE
Do not attempt any internal service or adjustment u nl ess another person, capable of rendering first aid and resuscitation, is present.
DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT
Do not install substitute parts o r perform any unauthorized modifications to this instrument. Return the instrument to B&K Precision for service and repair to ensure that safety features are maintained.
WARNINGS AND CAUTIONS
WARNING and CAUTION statements, suc h as the following examples, denote a hazar d and appear throughout this
manual. Follow all instructions contained in these statements. A WARNING statement calls atte ntion to an operating procedure, practic e , or condition, which, if not followed
correctly, could result in injury or d eath to personnel. A CAUTION statement calls attention to an operating procedure, practice, or condition, which, if not followed
correctly, could result in damage to or destruction of part or all of the product.
WARNING:
conductive parts (including control kno plug of the power cable meet IEC safety standards.
WARNING:
qualified personnel.
CAUTION:
CAUTION:
B fire protection, replace fuses only with those of the specified voltage and current ratings.
This product uses components which can be damaged by electro­subassemblies which contain ESD-sensitive components.
2
Contents
Safety Summary .......................................................................................................................................... 2
Specifications .............................................................................................................................................. 4
Package Contents ........................................................................................................................................ 5
Controls and Indicators ............................................................................................................................... 5
FEATURES ................................................................................................................................................ 6
BASIC OPERATION ................................................................................................................................. 6
Use of Pattern Applications ........................................................................................................................ 6
SERVICE INFORMATION ....................................................................................................................... 7
LIMITED ONE-YEAR WARRANTY....................................................................................................... 7
3

Specifications

Resolutions:
Type Resolution Horizontal Polarity Vertical Polarity
(kHz) (Hz) MDA 720 x 350 18.4 + 50 ­CGA 640 x 200 15.8 + 60 + EGA 640 x 350 21.8 + 60 ­VGA 640 x 480 31.5 - 60 ­SVGA 800 x 600 35.2 + 56 + 8514A 1024 x 384 35.5 + 87 + VESA 1024 x 768 48.5 - 60 ­ 1280 x 1024 64.0 + 60 + MAC 512 x 384 24.4 - 60 - Composite Sync 640 x 480 35.0 - 67 - Composite Sync 640 x 480 35.0 - 67 - Sync on Green 640 x 480 35.0 - 67 - Separate Sync 830 x 624 49.7 - 75 - Composite Sync 1152 x 870 68.7 - 75 - Composite Sync 1280 x 1024 80.0 - 75 - Composite Sync
Connector Pin Assignments:
15-HD 15-DB TTL 9-D
Pin No. Function Function Function
1 Red Video Ground Ground 2 Green Video Red Video Intensity 3 Blue Video Hor./Comp Sync Red Video 4 Not used Not used Green Video 5 Ground Green/Sync Blue Video 6 Ground Ground Intensity 7 Ground Not used Intensity 8 Ground Not used Hor. Sync 9 Not used Blue Video Ver. Sync 10 Ground Not used 11 Not used Ground 12 Not used Ver. Sync 13 Hor. Sync Ground 14 Ver. Sync Ground 15 Not used Hor./Comp Sync
General:
Power Source: AC 115Vac/230Vac, 50/60Hz (+10%) Dimensions (HxWxD): 3.9” x 10.25” x 10.8” (99 x 260.3 x 274.3mm) Weight: 3.1 lbs. (1.4 kgs.)
NOTE: Specifications and information are subject to change without notice. Please visit www.bkprecision.com for the most current product information.
4