B-K lighting PS, PSL Installation Instructions Manual

TECHNOLOGY
with
TECHNOLOGY
& Low Voltage
Installation Instructions
Warning Flammable Hot Surface
High Voltage
TOOLS
NEEDED:
By Others
1/8” Allen Wrench
Waterproof Wire Connectors
Mounting Hardware
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO PERSONS IMPORTANT SAFETY
INSTRUCTIONS
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when
Do not touch hot lens, guard, or enclosure (see diagram/
Do no touch the lamp at any time. Use a soft cloth. Oil
Do not operate the luminaire fitting with a missing or
Lighted lamp is HOT!
turning on.
Keep lamp away from materials that may burn.
picture).
from skin may damage lamp.
damaged shield.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel must perform all servicing or relamping of this product.
• Before wiring to power supply and during servicing or relamping, turn off power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body. Do not touch the lamp at any time. Use a clean, dry, soft cloth to handle the lamp. Oil from skin may damage the lamp and cause it to rupture.
• Replace lamp only with correct wattage and type of lamp marked on fixture label.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations • Suitable for mounting within 4 ft. of the ground.
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.
This set of instructions works for:
PS - Path Star™
PSL - Louvered Path Star™
PSL
Anchor Base
on Power Pipe
TM
Stability Flange
18 Gauge Wire
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-30-16
REFERENCE NUMBER
INS000733.1
PS
Finished grade
Concrete
Finished grade
Finished grade
Optional
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Optional
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete
Finished grade
Pea gravel or sand
TECHNOLOGY
with
TECHNOLOGY
& Low Voltage
PS™ / PSL™
Installation Instructions
TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE™ IS LABELED AT GRADE LEVEL.
TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY
Soil Prep
Excavated
Conduit trench
for Housing
Conduit Trench
A. Determine Soil Type by referencing DIG-IT Guide.
Prep soil according to DIG-IT Guide.
B. Dig hole 10” wide and 24” deep.
Power Pipe with Anchor Base Mounting Option
1. Excavate trench according to designed lighting plan. Dig hole a minimum of 18” deep and 10” wide to accommodate Power Pipe™ at desired fixture locations.
2. Slide optional Stability Flange onto Power Pipe™. Use optional Stability Flange to aid in installation of Power Pipe™.
C. Prep soil according to DIG-IT Guide.
3. Pull branch circuit wiring necessary for installation (By Others) to Power Pipe™. Place Power Pipe™ in hole.
Allow for additional cable to make connections
to fixture leads and future service. Do not cut PVC.
Remote Transformer
4. Back fill with pea gravel or sand prior to pour.
5. Pour concrete (By Others).
Label on Power Pipe™ indicates installation
depth with finished grade.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
B-K LIGHTING
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
Remote Transformer
6. Make watertight connections from remote 12V transformer to LED source leads (18 gauge wire) using waterproof wire connectors (By Others).
See wiring diagram.
RELEASE DATE
11-30-16
REFERENCE NUMBER
INS000733.1
TECHNOLOGY
with
TECHNOLOGY
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
Integral
Transformer
COM
GROUND IN HOUSING
Integral Transformer
& Low Voltage
Installation Instructions
PS™ / PSL™
Integral Transformer
7. Pull branch circuit wires necessary for installation (By Others) through Power Pipe™. Use waterproof wire connectors (By Others) to connect transformer primary leads to branch circuit wires. Connect incoming ground to ground wire provided in fixture body. See
wiring diagram.
WIRING DIAGRAM
8. Place fixture on anchor base and tighten four (4) #10-32 stainless steel button head cap screws using a 1/8” Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-30-16
REFERENCE NUMBER
INS000733.1