Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
By Others
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Additionally suitable for mounting within 4 ft. of the ground
YO - Yosemite Series™
Wall Wash
REMOTE WIRING
Optic
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (By Others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
DRIVER HOUSING REQUIRED
Please refer to specified remote driver housing
documentation for detailed installation instructions.
REMOTE DRIVER HOUSINGS:
360HD™
Mounting
System
HP2RM - HP2 Remote Housing
PM3RM - Universal Power Module 3 Remote
PM3DRM - Universal Power Module 3 Dual Remote
RM - Remote Wall Mount
DRM - Dual Remote Wall Mount
ACV™ Valve (Detail)
1/2” NPS
Threaded Nipple
HP2RM
PM3RM &
PM3DRM
RM &
DRM
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
www.bklighting.com • info@bklighting.com
RELEASED
11-9-17
REFERENCENUMBER
INS-2573-00
10"
(254mm)
3" Dia.
(76mm)
2 11/16"(68mm)
(203mm)
8"
(76mm)
3" Dia.
2 11/16"(68mm)
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™Mounting System
2 11/16"
(68mm)
GROUND
Black
White
Hydrolock
Plate
Green
Driver
White
Black
White
Blue
Green
LINE
COM
GROUND
Orange
Orange
Brown
Blue
Black
Gray
FIXTURE
FIXTURE
Green
Green
GROUND
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
Generic TR
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
Quick
Connect
Driver
FIXTURE
DIM +
DIM -
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
DIM +
DIM -
PM3DRM
Fixture
Fixture
Remote
Driver
Fixture
Fixture
Standard Installation
YOSEMITE SERIES™
Remote - Solid State LED
Fixture Installation
1. Mount fixture onto suitable enclosure according
2. Secure ½” NPS stem to mounting option. Secure
to designed lighting plan.
with provided locknut if applicable.
3. Make watertight connections from remote
driver to fixture leads using waterproof wire
connectors (By Others). See wiring diagram.
DIM +
DIM -
LINE
COM
GROUND
WIRING DIAGRAM
Remote
Driver
Red
FIXTURE
Black
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
11-9-17
REFERENCENUMBER
INS-2573-00
10"
(254mm)
3" Dia.
(76mm)
2 11/16"(68mm)
(203mm)
8"
(76mm)
3" Dia.
2 11/16"(68mm)
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™Mounting System
2 11/16"(68mm)
Standard Installation
LED and Optic Replacement
YOSEMITE SERIES™
Remote - Solid State LED
1. Loosen three (3) captive #6-32 screws securing
cap/socket assembly with 7/64” Allen wrench.
NOTE: Only one end cap (without ACV™) is
removable.
4. Detach heatsink from fixture body via quick
disconnect.
Do not pull on connector or wiring. Handle
with care.
2. Depress patented Anti-Condensation Valve™
(ACV™) to release vacuum and pull cap/socket
assembly to access. Screws will be retained in
cap.
5. Loosen four (4) #6-32 screws on wall wash optic
holder using 7/64” Allen wrench, then gently
pull away to remove from heatsink.
3. Carefully pull out end cap assembly. LED is still
attached to leads.
Do not pull on connector or wiring. Handle
with care.
6. Loosen, then remove two (2) #4-40 screws from
LED module using .050” Allen wrench.
7. Carefully remove LED module from heatsink.
Do not pull on connector or wiring. Handle
with care.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
8. Use small pick tool to push connector off
LED board through two small slots behind
connector. Once loose, lift connector upwards
and off board.
Fragile! Do not pull on connector or wiring.
Handle with care.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
9. Spread thin, even layer of thermal paste on back
of new LED module. Place new LED module onto
heatsink, lining up module with holes for screws.
Tighten two (2) #4-40 screws using .050” Allen
wrench to secure LED module to heatsink.
RELEASED
11-9-17
REFERENCENUMBER
INS-2573-00
10"
(254mm)
3" Dia.
(76mm)
2 11/16"(68mm)
(203mm)
8"
(76mm)
3" Dia.
2 11/16"(68mm)
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™Mounting System
2 11/16"(68mm)
Standard Installation
YOSEMITE SERIES™
Remote - Solid State LED
10. Press connector straight downwards into slot on
module to snap into place.
Connector will only fit in one direction.
13. Re-install end cap assembly.
11. Place wall wash optic over LED module, lining
up screw locations with holes in heatsink. Secure
wall wash optic to heatsink with four (4) #6-32
screws using 7/64” Allen wrench.
14. Tighten three (3) captive #6-32 screws with 7/64”
Allen wrench to secure cap assembly.
12. Attach heatsink to fixture via quick disconnect.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
11-9-17
REFERENCENUMBER
INS-2573-00
Standard Adjustment
WarningHot Surface
360HD™ Mounting System
TOOLS
NEEDED:
By Others
3/16” Allen wrench
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when
Do not touch hot lens, guard, or enclosure (see diagram/
Do no touch the lamp at any time. Use a soft cloth. Oil
Do not operate the luminaire fitting with a missing or
Lighted lamp is HOT!
turning on.
Keep lamp away from materials that may burn.
picture).
from skin may damage lamp.
damaged shield.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel must perform all servicing or relamping of
this product.
• Before wiring to power supply and during servicing or relamping,
turn off power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
• Do not block light emanating from product in whole or part,
as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time. Use
a clean, dry, soft cloth to handle the lamp. Oil from skin may
damage the lamp and cause it to rupture.
• Replace lamp only with correct wattage and type of lamp
marked on fixture label.
• All gaskets, O-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Additionally suitable for mounting within 4 ft. of the ground
360HD™ Knuckle
1. Use 3/16” Allen wrench to slightly loosen
(1) 3/8”-16 x 3/8” stainless steel black oxide set screw
on the stem for 360° aiming purpose.
2. Rotate fixture at base and aim fixture to desired
horizontal location.
3. Use 3/16” Allen wrench to loosen (1) 1/4”-28 x 1-1/4”
stainless steel black oxide socket head cap screw at
the knuckle for vertical aiming purpose.
4. Tighten (1) 3/8”-16 x 3/8” stainless steel black oxide
set screw on the stem to secure horizontal aiming
position.
Tighten (1) 1/4”-28 x 1-1/4” stainless steel black
oxide socket head cap screw to 24” minimum to 48”
maximum pounds to secure vertical aiming position
Warning: Do not over tighten set screw. Doing
so will compromise O-ring seal and will void
warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
www.bklighting.com • info@bklighting.com
RELEASED
1-31-14
REFERENCENUMBER
INS-2096-00
NEMA 3R Remote Power Supply
23W-34W Solid State LED
Installation Instructions
INSTALLATION:
WarningHigh VoltageHot Surface
INSTRUCTIONS PERTAINING TO
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
By Others
AND INSTALLATION INSTRUCTIONS
NEEDED
FOR
1/8” Allen Wrench
Phillips Screwdriver
Level
Hammer
Mounting Hardware
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Driver
Terminal
Block
Dual Drivers
Terminal Block (B)
(Dimming Controls)
Terminal
Block
(A)
RM - Single Remote Housing
Cover
DRM - Dual Remote Housing
Cover
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2679-00
Installation Instructions
Housing Installation
NEMA 3R Remote Power Supply
23W-34W Solid State LED
1. Remove cover by removing #10-24 cover screw
using a 1/8” Allen wrench.
2. Attach the NEMA 3R housing at mounting holes
with ¼” fasteners (By Others). Use suitable
mounting hardware for surface. Use level to
ensure a level install.
NOTE: Many methods exist to bolt to a
flat surface. The housing is provided with
mounting brackets with ¼” holes.
Single Remote Driver with Dimming Controls
4. Connect conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit with a suitable
sealant (Teflon tape, adhesive, etc.). Sealing
the conduit after knockouts are removed is
required to maintain warranty.
5. Pull branch circuit wiring necessary for
installation (By Others). Pull dimming control
wiring necessary for installation (By Others).
3. Remove Knockout(s) with hammer as needed
from the NEMA 3R housing. Leave remaining
unused knockouts in place to maintain seal.
6. Pull secondary lamp leads necessary for
installation though dedicated conduit. (By
Others).
NOTE: Failure to comply with specific wiring
requirements will void product warranty.
-
LED
DIM
COM
+
LED
DIM
7. Connect branch circuit to terminal block. Connect incoming ground to ground wire provided on NEMA 3R
housing. Connect secondary lamp leads to terminal. See labels on terminal block for additional information..
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
DIM
DIM
COM
LED
LED
-
+
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
8. Re-attach cover. Tighten cover screw.
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2679-00
DIM
1
DIM
COM
1
DIM
+
1
DIM
1
DIM2DIM
COM
2
DIM
+
2
DIM
2
Installation Instructions
Dual Remote Driver with Dimming Controls
NEMA 3R Remote Power Supply
23W-34W Solid State LED
4. Connect conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit with a suitable
sealant (Teflon tape, adhesive, etc.). Sealing
the conduit after knockouts are removed is
required to maintain warranty.
B
Ground
DIM
DIM2DIM
DIM
1
1
2
COM
COM
DIM
DIM
DIM
DIM
1
2
1
2
+
+
120-208-
120-208-
240-277
240-277
VOLT
7. Terminal A is for circuit branch wiring and fixture
leads. Terminal B is for dimming controls. The
grounding screw is located to the upper right of
terminal A.
A
LAMP
LAMP2LAMP
LAMP
1
1
2
COM
COM
VOLT
LED
LED
LED
COM
LED
1
2
1
2
+
+
5. Pull branch circuit wiring necessary for
installation (By Others). Pull dimming control
wiring necessary for installation (By Others).
120-208-
120-208-
240-277
240-277
VOLT
VOLT
COM
8. Terminal Block A - Connect branch circuit to terminal block. Connect incoming ground to ground wire
provided on NEMA 3R housing. Connect secondary lamp leads to terminal A. See labels on terminal block for
additional information.
6. Pull secondary lamp leads necessary for
installation though dedicated conduit. (By
Others).
NOTE: Failure to comply with specific wiring
requirements will void product warranty.
LAMP
1
1
LED
1
1
+
LAMP
COM
LED
LAMP2LAMP
LED
2
+
2
COM
LED
2
For use with 23-34 watt dimming driver.
DIM
1
DIM
1
+
DIM
DIM
COM
9. Terminal Block B - Connect incoming dimming
1
1
controls to terminal block. See labels on terminal
block for additional information.
DIM2DIM
DIM
2
+
2
COM
DIM
2
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
10. Re-attach cover. Tighten cover screw.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2679-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
NEEDED
FOR
INSTALLATION:
1/8” Allen Wrench
Waterproof Wire Connectors
Level
Phillips Screwdriver
WarningHigh VoltageHot Surface
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
By Others
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Suitable for recessed in ground locations
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.
Faceplate
Driver
Assembly
Quick
Disconnects
Patented
Hydro-Lock™
Plate
Waterproof Wire
Connectors
Silicone ‘O’ Ring
Concrete Pour Collar
Patented
Stability
HP2RM Housing
Flange
Soil Prep
Conduit
trench
A. Determine Soil Type by referencing
DIG-IT Guide.
B. Dig hole 18” wide and 20” deep.
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
Conduit
Trench
18”
Dia.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2681-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
Housing Installation
Side Flats
Threaded Entry
1. Connect branch conduit connectors (By Others)
to the junction box using either the threaded
conduit entries on the bottom of the junction
box or through holes drilled into the sides of the
junction box.
Flush with finished grade
PROJECT:
TYPE:
2. Place housing in hole. Align junction box in the
path of the conduit trench.
3. Insert (4) pieces of ½” EMT conduit through the
Stability Flange™. Hammer into substrate until
secure.
Leave sufficient clearance to elevate housing
to finished grade.
4. Raise housing on EMT so concrete pour collar is
flush with finished grade. Use a level to aid in
housing installation.
7. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with
sand for drainage.
5. When housing is level, tighten screws on
Stability Flange™ to secure housing to EMT.
Remove excess EMT as needed.
8. For soil installation: Fill and tamp soil to
the appropriate height leaving room for sod,
pavers, etc. to be level with the top of the
temporary cover.
Soil installation is not drive-over rated.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
6. Connect the conduit to the conduit connectors.
9. For concrete installation: Fill the hole around
the fixture housing to 12” below the finished
grade with clean fill dirt and tamp carefully to
prevent settling of fixture. Pour concrete and
finish as required flush with the top surface of
the temporary cover.
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2681-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
Installation
1. Remove temporary cover.
2. Pull primary branch circuit wiring into junction
box.
PROJECT:
TYPE:
3. Make watertight connections using waterproof
wire connectors (provided) to leads on the
bottom of Patented HydroLock® Barrier Plate
Assembly. See wiring diagram(s).
LINE
COM
GROUND
Hydrolock
DIM +
DIM -
FIXTURE
FIXTURE
WIRING DIAGRAM
For use with 23-34 watt dimming driver.
Plate
4. Wipe inside of housing where HydroLock® plate
will sit clean of debris before inserting patented
HydroLock® plate on to junction box. Align
HydroLock® plate with pins in housing and seat
it firmly in place.
7. Lower driver assembly into HP2 housing.
5. Turn HydroLock® Barrier Plate clockwise ¼” to
lock.
PatentedHydroLock® Barrier Plate must be
completely seated to ensure proper seal or
water may intrude. This step must be done as
stated or you will void your warranty.
8. Attach driver assembly to housing by aligning
keyhole notch under one (1) of three (3) #8
screw heads.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
6. Connect driver assembly to Patented
HydroLock® Barrier plate with quick disconnects.
9. Tighten the Phillips screws to secure driver
plate to housing.
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2681-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Driver Installation Instructions
10. Remove any dirt or debris in O-ring groove near
top of housing. Place O-Ring inside of groove.
Failure to clean groove of debris will cause
fixture to fail and void product warranty.
PROJECT:
TYPE:
11. Install faceplate using 1/8” Allen wrench and
hand-tighten the faceplate screws in a star
pattern to 30 in-lbs. min.
Do not use a power tool to install screws. Do
not exceed 40 in-lbs.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCENUMBER
INS-2681-00
Installation Instructions
WarningHigh Voltage
Hot Surface
TOOLS
NEEDED:
By Others
PM3RM TREE STRAP™
Driver Housing
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Driver
Adjustable
Tree Strap
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
PM3RM
Housing
Faceplate
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
Installation Instructions
LAMP
BLUEWHITEGROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
GroundHotNeutral
LAMP
BLUEWHITEGROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
GroundHotNeutral
LAMP
BLUEWHITEGROUND
BARE WIRE
IN UPM
GroundHotNeutral
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3RM TREE STRAP™
Driver Housing
PROJECT:
TYPE:
1. Loosen (6) #10-24 captive screws using a 1/8” Allen
wrench to remove faceplate of UPM housing.
4. Thread safety cable through hole on the back of the
UPM housing. Feed safety cable through opposing
ends of the connector. Pull on wires to assure the
connection is secure. Leave enough slack in safety
cable for tree growth. Adjustments can be made
by pressing release spring with a pin or 3/64” Allen
tool.
2. Remove Patented Knockout(s) as necessary
from the inside of the UPM housing. Leave
remaining unused knockouts in place to
maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped
back into place to renew seal integrity.
5. Connect 3/4” conduit connector through
female threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit pipe with
a suitable sealant (Teflon tape, adhesive,
etc). Sealing the conduit after knockouts are
removed is required to maintain warranty.
DIM +
DIM -
LINE
COM
Fixture
Fixture
GROUND IN HOUSING
Remote
Driver
3. Use adjustable strap provided to attach UPM
housing to tree. Tighten by pulling on the
adjustable strap until secure.
6. Pull branch circuit wiring and dimming control
wiring necessary for installation (By Others).
7. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower the
faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety
cable. Do not add weight to, or drop faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
WIRING DIAGRAM
8. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground
wire provided in UPM housing. Connect
incoming dimming control wires to driver
dimming controls. See wiring diagram.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
9. Remove two (2) #8-32 screws in UPM housing
using Phillips screwdriver.
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
LAMP
BLUEWHITEGROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
LAMP
BLUEWHITEGROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
Installation Instructions
10. Slide driver feet under two screws in UPM housing
and tighten screws using Phillips screwdriver.
11. Reinstall #8-32 screws on other side of driver and
tighten to secure driver to UPM housing.
PROJECT:
TYPE:
12. Make sure UPM housing gasket is free of
any dirt or debris. Attach the faceplate by
tightening the (6) #10-24 captive screws
evenly using a 1/8” Allen wrench.
PM3RM TREE STRAP™
Driver Housing
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
Installation Instructions
WarningHigh Voltage
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
PM3RM SURFACE MOUNT™
Driver Housing
NEEDED
INSTALLATION:
Hot Surface
By others
FOR
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
1/4” Drill Bit and Drill
Mounting Hardware
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
PM3RM
Housing
Surface Mount
Knockouts
Faceplate
Driver
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
GroundHotNeutral
LAMP
BLUEWHITEGROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
Installation Instructions
1. Prepare final mounting position according to
designed lighting plan.
PM3RM SURFACE MOUNT™
PROJECT:
TYPE:
2. Drill holes into surface for ¼” fasteners (By
Others) on locations required for mounting via
tabs.
Driver Housing
3. Loosen (6) #10-24 captive screws using a 1/8”
Allen wrench to remove faceplate of UPM
housing.
4. Remove Patented Knockout(s) as necessary
from the inside of the UPM housing. Leave
remaining unused knockouts in place to
maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back
7. Pull branch circuit wiring and dimming control
wiring necessary for installation (By Others.)
5. Attach the UPM housing at mounting brackets
with ¼” fasteners (By Others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
6. Connect 3/4” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit with a suitable
sealant (Teflon tape, adhesive, etc.). Sealing
the conduit after knockouts are removed is
required to maintain warranty.
DIM +
DIM -
LINE
COM
Fixture
Fixture
Remote
Driver
GROUND IN HOUSING
8. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
WIRING DIAGRAM
9. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground wire
provided in UPM housing. Connect incoming
dimming control wires to driver dimming
controls. See wiring diagram.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
Installation Instructions
PM3RM SURFACE MOUNT™
Driver Housing
PROJECT:
TYPE:
10. Remove two (2) #8-32 screws in UPM housing
using Phillips screwdriver.
11. Slide driver feet under two screws in UPM
housing and tighten screws using Phillips
screwdriver.
12. Reinstall two (2) #8-32 screws on other side
of driver and tighten to secure driver to UPM
housing.
13. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
Installation Instructions
WarningHigh Voltage
Hot Surface
PM3RM ROUND CAMLOCK™
Driver Housing
NEEDED
FOR
INSTALLATION:
By others
1/8” & 9/64” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver
Level
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
Universal
Mounting
Ring™
CamLock™
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Driver
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
PM3RM
Housing
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
Faceplate
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
Installation Instructions
Horizontal
Vertical
GroundHotNeutral
GroundHotNeutral
BC
Horizontal
Vertical
GroundHotNeutral
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
1. Install standard 4” octagonal/round recessed
junction box in the final fixture location according
to designed lighting plan.
2. Pull branch circuit wiring and dimming control
wiring necessary for installation (By Others.)
PM3RM ROUND CAMLOCK™
Driver Housing
PROJECT:
TYPE:
Horizontal
Install universal mounting ring.
3.
IMPORTANT!! Orientation of universal ring will affect orientation of UPM! Take note of
mounting plate holes (indicated with arrows) on the universal ring holes to mount UPM in
correct orientation.
Vertical
4. Feed branch circuit wiring and dimming control
wiring through mounting plate with CamLock™
assembly. Attach mounting plate with supplied
(2) #10-24 stainless steel hex drive fasteners to
universal ring using 1/8” Allen wrench.
8. Attach tether wire under screw head at the base
of the UPM housing. Slowly lower the faceplate
until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
A
5. Feed branch circuit wiring and dimming control
wiring into UPM housing. Install housing on
CamLock™ at 90° to finished orientation as
shown. (Figure A)
6. Rotate housing 90° counter-clockwise (Figure
B). Tighten set screw with 5/64” Allen wrench on
outside of UPM housing to lock in place.
(Figure C)
DIM +
DIM -
LINE
COM
Fixture
Fixture
GROUND IN HOUSING
WIRING DIAGRAM
9. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground wire
provided in UPM housing. Connect incoming
dimming control wires to driver dimming
controls See wiring diagram.
Remote
Driver
7. If UPM housing is not level, remove UPM housing;
loosen but DO NOT REMOVE (2) #8-32 screws
with 9/64” Allen wrench on CamLock™ assembly.
Adjust CamLock™ assembly up to 30° as needed
to level. Tighten the screws and reattach UPM
housing.
10. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2187-00
Installation Instructions
WarningHigh Voltage
Hot Surface
TOOLS
NEEDED:
By Others
PM3DRM TREE STRAP™
Driver Housing
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
Driver
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Faceplate
Failure to comply with specific wiring
requirements will void product warranty.
Adjustable
Tree Strap
PM3DRM
Housing
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
Installation Instructions
GroundHotNeutral
GroundHotNeutral
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3DRM
PM3DRM TREE STRAP™
Driver Housing
PROJECT:
TYPE:
1. Loosen (6) #10-24 captive screws using a 1/8” Allen
4. Thread safety cable through hole on the back of the
wrench to remove faceplate of UPM housing.
UPM housing. Feed safety cable through opposing
ends of the connector. Pull on wires to assure the
connection is secure. Leave enough slack in safety
cable for tree growth. Adjustments can be made
by pressing release spring with a pin or 3/64” Allen
tool.
2. Remove Patented Knockout(s) as necessary
from the inside of the UPM housing. Leave
remaining unused knockouts in place to
maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped
back into place to renew seal integrity.
5. Connect 3/4” conduit connector through
female threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit pipe with
a suitable sealant (Teflon tape, adhesive,
etc). Sealing the conduit after knockouts are
removed is required to maintain warranty.
Fixture
Fixture
DIM +
DIM -
Remote
Driver
3. Use adjustable strap provided to attach UPM
housing to tree. Tighten by pulling on the
adjustable strap until secure.
6. Pull branch circuit wiring and dimming control
wiring necessary for installation (By Others).
7. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower the
faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety
cable. Do not add weight to, or drop faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
LINE
COM
DIM +
Remote
DIM -
Driver
Fixture
Fixture
GROUND IN HOUSING
WIRING DIAGRAM
8. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground
wire provided in UPM housing. Connect
dimming control wiring to driver dimming
leads. See wiring diagram.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
9. Remove two (2) #8-32 screws in UPM housing
using Phillips screwdriver.
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
PM3DRM TREE STRAP™
Driver Housing
Installation Instructions
11. Slide driver feet under two screws in UPM housing
and tighten screws using Phillips screwdriver.
12. Reinstall #8-32 screws on other side of driver and
tighten to secure driver to UPM housing.
PROJECT:
TYPE:
13. Make sure UPM housing gasket is free of any dirt
or debris. Attach the faceplate by tightening the
(6) #10-24 captive screws evenly to 30 in-lbs using
a 1/8” Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
Installation Instructions
WarningHigh Voltage
Hot Surface
PM3DRM SURFACE MOUNT™
Driver Housing
NEEDED
FOR
INSTALLATION:
By others
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
1/4” Drill Bit and Drill
Mounting Hardware
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
Surface Mount
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
PM3DRM
Housing
Driver
Faceplate
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
GroundHotNeutral
LAMP
BLUEWHITEGROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3DRM
Installation Instructions
1. Prepare final mounting position according to
designed lighting plan.
PM3DRM SURFACE MOUNT™
PROJECT:
TYPE:
2. Drill holes into surface for ¼” fasteners (By
Others) on locations illustrated on template.
Driver Housing
3. Loosen (6) #10-24 captive screws using a 1/8”
Allen wrench and disconnect quick disconnect
to remove faceplate of UPM housing.
4. Remove Patented Knockout(s) as necessary
from the inside of the UPM housing. Leave
remaining unused knockouts in place to
maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back
into place to renew seal integrity.
5. Attach the UPM housing at mounting brackets
with ¼” fasteners (By Others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
6. Connect 3/4” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit with a suitable
sealant (Teflon tape, adhesive, etc.). Sealing
the conduit after knockouts are removed is
required to maintain warranty.
Fixture
Fixture
DIM +
DIM -
LINE
COM
DIM +
DIM -
Fixture
Fixture
GROUND IN HOUSING
Remote
Driver
Remote
Driver
7. Pull branch circuit wiring and incoming dimming
control wiring necessary for installation (By
Others.)
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
8. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
WIRING DIAGRAM
9. Use wire connectors (By Others) to connect
driver primary leads to branch circuit wires.
Connect incoming ground to ground wire
provided in UPM housing. Connect incoming
dimming control wiring to driver dimming leads.
See wiring diagram.
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
Installation Instructions
PM3DRM SURFACE MOUNT™
Driver Housing
PROJECT:
TYPE:
10. Remove two (2) #8-32 screws in UPM housing
using Phillips screwdriver.
11. Slide driver feet under two screws in UPM
housing and tighten screws using Phillips
screwdriver.
12. Reinstall #8-32 screws on other side of driver and
tighten to secure driver to UPM housing.
13. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
Installation Instructions
WarningHigh Voltage
Hot Surface
NEEDED
INSTALLATION:
By others
PM3DRM CAMLOCK™
Driver Housing
FOR
1/8” & 9/64” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver
Level
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected
wiring between the LED and driver (by others). Drivers
have specific wiring requirements between these
components. Driver manufacturers regularly recommend
the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance
using 12 gauge copper wire.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
Driver
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Faceplate
Failure to comply with specific wiring
requirements will void product warranty.
Universal
Mounting
CamLock™
Ring™
PM3DRM
Housing
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
Installation Instructions
Horizontal
Vertical
GroundHotNeutral
GroundHotNeutral
BC
Horizontal
Vertical
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3DRM
PM3DRM ROUND CAMLOCK™
Driver Housing
PROJECT:
TYPE:
1. Install standard 4” octagonal/round recessed
junction box in the final fixture location according
to designed lighting plan.
2. Pull branch circuit wiring and dimming control
wiring necessary for installation (By Others.)
4. Feed branch circuit wiring and dimming control
wiring through mounting plate with CamLock™
assembly. Attach mounting plate with supplied
(2) #10-24 stainless steel hex drive fasteners to
universal ring using 1/8” Allen wrench.
Horizontal
Vertical
Install universal mounting ring.
3.
IMPORTANT!! Orientation of universal ring will affect orientation of UPM! Take note of mounting
plate holes (indicated with arrows) on the universal ring holes to mount UPM in correct
orientation.
A
5. Feed branch circuit wiring and dimming control
wiring into UPM housing. Install housing on
CamLock™ at 90° to finished orientation as
shown. (Figure A)
6. Rotate housing 90° counter-clockwise (Figure
B). Tighten set screw with 5/64” Allen wrench
on outside of UPM housing to lock in place.
(Figure C)
Fixture
Fixture
DIM +
DIM -
Remote
Driver
7. If UPM housing is not level, remove UPM housing;
loosen but DO NOT REMOVE (2) #8-32 screws
with 9/64” Allen wrench on CamLock™ assembly.
Adjust CamLock™ assembly up to 30° as needed
to level. Tighten the screws and reattach UPM
housing.
8. Attach tether wire under screw head at the base
of the UPM housing. Slowly lower the faceplate
until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
LINE
COM
DIM +
Remote
DIM -
Driver
Fixture
Fixture
GROUND IN HOUSING
WIRING DIAGRAM
9. Use wire connectors (By Others) to connect
driver primary leads to branch circuit wires.
Connect incoming ground to ground wire
provided in UPM housing. Connect incoming
dimming control wiring to driver dimming leads.
See wiring diagram.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
10. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
RELEASED
12-8-17
REFERENCENUMBER
INS-2188-00
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.