B-K lighting HP2RM, DRM, PM3RM, RM, PM3DRM Installation Instructions Manual

Standard Installation
PM2RM PM2DRM
PM3RM PM3DRM
PM2RM PM2DRM
PM3RM PM3DRM
TOOLS
NEEDED:
YOSEMITE SERIES™
Remote - Solid State LED
Waterproof Wire Connectors
7/64” & 0.050” Allen Wrench
Warning Flammable Hot Surface Low Voltage
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
By Others
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Additionally suitable for mounting within 4 ft. of the ground
YO - Yosemite Series™
Wall Wash
REMOTE WIRING
Optic
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (By Others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
DRIVER HOUSING REQUIRED
Please refer to specified remote driver housing documentation for detailed installation instructions.
REMOTE DRIVER HOUSINGS:
360HD™ Mounting System
HP2RM - HP2 Remote Housing PM3RM - Universal Power Module 3 Remote PM3DRM - Universal Power Module 3 Dual Remote RM - Remote Wall Mount DRM - Dual Remote Wall Mount
ACV™ Valve (Detail)
1/2” NPS Threaded Nipple
HP2RM
PM3RM & PM3DRM
RM &
DRM
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
www.bklighting.com • info@bklighting.com
RELEASED
11-9-17
REFERENCE NUMBER
INS-2573-00
10"
(254mm)
3" Dia.
(76mm)
2 11/16" (68mm)
(203mm)
8"
(76mm)
3" Dia.
2 11/16" (68mm)
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™ Mounting System
2 11/16"
(68mm)
GROUND
Black
White
Hydrolock
Plate
Green
Driver
White
Black
White
Blue
Green
LINE
COM
GROUND
Orange
Orange
Brown
Blue
Black
Gray
FIXTURE
FIXTURE
Green
Green
GROUND
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
Generic TR
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
Quick
Connect
Driver
FIXTURE
DIM +
DIM -
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
DIM +
DIM -
PM3DRM
Fixture
Fixture
Remote
Driver
Fixture
Fixture
Standard Installation
YOSEMITE SERIES™
Remote - Solid State LED
Fixture Installation
1. Mount fixture onto suitable enclosure according
2. Secure ½” NPS stem to mounting option. Secure
to designed lighting plan.
with provided locknut if applicable.
3. Make watertight connections from remote driver to fixture leads using waterproof wire connectors (By Others). See wiring diagram.
DIM +
DIM -
LINE
COM
GROUND
WIRING DIAGRAM
Remote
Driver
Red
FIXTURE
Black
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
11-9-17
REFERENCE NUMBER
INS-2573-00
10"
(254mm)
3" Dia.
(76mm)
2 11/16" (68mm)
(203mm)
8"
(76mm)
3" Dia.
2 11/16" (68mm)
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™ Mounting System
2 11/16" (68mm)
Standard Installation
LED and Optic Replacement
YOSEMITE SERIES™
Remote - Solid State LED
1. Loosen three (3) captive #6-32 screws securing cap/socket assembly with 7/64” Allen wrench.
NOTE: Only one end cap (without ACV) is
removable.
4. Detach heatsink from fixture body via quick disconnect.
Do not pull on connector or wiring. Handle
with care.
2. Depress patented Anti-Condensation Valve™ (ACV™) to release vacuum and pull cap/socket assembly to access. Screws will be retained in cap.
5. Loosen four (4) #6-32 screws on wall wash optic holder using 7/64” Allen wrench, then gently pull away to remove from heatsink.
3. Carefully pull out end cap assembly. LED is still attached to leads.
Do not pull on connector or wiring. Handle
with care.
6. Loosen, then remove two (2) #4-40 screws from LED module using .050” Allen wrench.
7. Carefully remove LED module from heatsink.
Do not pull on connector or wiring. Handle
with care.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
8. Use small pick tool to push connector off LED board through two small slots behind connector. Once loose, lift connector upwards and off board.
Fragile! Do not pull on connector or wiring.
Handle with care.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
9. Spread thin, even layer of thermal paste on back of new LED module. Place new LED module onto heatsink, lining up module with holes for screws. Tighten two (2) #4-40 screws using .050” Allen wrench to secure LED module to heatsink.
RELEASED
11-9-17
REFERENCE NUMBER
INS-2573-00
10"
(254mm)
3" Dia.
(76mm)
2 11/16" (68mm)
(203mm)
8"
(76mm)
3" Dia.
2 11/16" (68mm)
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™ Mounting System
2 11/16" (68mm)
Standard Installation
YOSEMITE SERIES™
Remote - Solid State LED
10. Press connector straight downwards into slot on module to snap into place.
Connector will only fit in one direction.
13. Re-install end cap assembly.
11. Place wall wash optic over LED module, lining up screw locations with holes in heatsink. Secure wall wash optic to heatsink with four (4) #6-32 screws using 7/64” Allen wrench.
14. Tighten three (3) captive #6-32 screws with 7/64” Allen wrench to secure cap assembly.
12. Attach heatsink to fixture via quick disconnect.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
11-9-17
REFERENCE NUMBER
INS-2573-00
Standard Adjustment
Warning Hot Surface
360HD™ Mounting System
TOOLS
NEEDED:
By Others
3/16” Allen wrench
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when
Do not touch hot lens, guard, or enclosure (see diagram/
Do no touch the lamp at any time. Use a soft cloth. Oil
Do not operate the luminaire fitting with a missing or
Lighted lamp is HOT!
turning on.
Keep lamp away from materials that may burn.
picture).
from skin may damage lamp.
damaged shield.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel must perform all servicing or relamping of
this product.
• Before wiring to power supply and during servicing or relamping,
turn off power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body. Do not touch the lamp at any time. Use a clean, dry, soft cloth to handle the lamp. Oil from skin may damage the lamp and cause it to rupture.
• Replace lamp only with correct wattage and type of lamp marked on fixture label.
• All gaskets, O-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Additionally suitable for mounting within 4 ft. of the ground
360HD™ Knuckle
1. Use 3/16” Allen wrench to slightly loosen (1) 3/8”-16 x 3/8” stainless steel black oxide set screw on the stem for 360° aiming purpose.
2. Rotate fixture at base and aim fixture to desired horizontal location.
3. Use 3/16” Allen wrench to loosen (1) 1/4”-28 x 1-1/4” stainless steel black oxide socket head cap screw at the knuckle for vertical aiming purpose.
4. Tighten (1) 3/8”-16 x 3/8” stainless steel black oxide set screw on the stem to secure horizontal aiming position.
Tighten (1) 1/4”-28 x 1-1/4” stainless steel black
oxide socket head cap screw to 24” minimum to 48” maximum pounds to secure vertical aiming position
Warning: Do not over tighten set screw. Doing so will compromise O-ring seal and will void warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
www.bklighting.com • info@bklighting.com
RELEASED
1-31-14
REFERENCE NUMBER
INS-2096-00
NEMA 3R Remote Power Supply
23W-34W Solid State LED
Installation Instructions
INSTALLATION:
Warning High Voltage Hot Surface
INSTRUCTIONS PERTAINING TO
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
By Others
AND INSTALLATION INSTRUCTIONS
NEEDED
FOR
1/8” Allen Wrench
Phillips Screwdriver
Level
Hammer
Mounting Hardware
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
Driver
Terminal
Block
Dual Drivers
Terminal Block (B)
(Dimming Controls)
Terminal
Block
(A)
RM - Single Remote Housing
Cover
DRM - Dual Remote Housing
Cover
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2679-00
Installation Instructions
Housing Installation
NEMA 3R Remote Power Supply
23W-34W Solid State LED
1. Remove cover by removing #10-24 cover screw using a 1/8” Allen wrench.
2. Attach the NEMA 3R housing at mounting holes with ¼” fasteners (By Others). Use suitable mounting hardware for surface. Use level to ensure a level install.
NOTE: Many methods exist to bolt to a
flat surface. The housing is provided with mounting brackets with ¼” holes.
Single Remote Driver with Dimming Controls
4. Connect conduit connector through female threaded conduit entry.
NOTE: Surface conduit is a common entrance for water if not properly sealed. Seal connector threads and conduit with a suitable sealant (Teflon tape, adhesive, etc.). Sealing the conduit after knockouts are removed is required to maintain warranty.
5. Pull branch circuit wiring necessary for installation (By Others). Pull dimming control wiring necessary for installation (By Others).
3. Remove Knockout(s) with hammer as needed from the NEMA 3R housing. Leave remaining unused knockouts in place to maintain seal.
6. Pull secondary lamp leads necessary for installation though dedicated conduit. (By Others).
NOTE: Failure to comply with specific wiring requirements will void product warranty.
-
LED
DIM
COM
+
LED
DIM
7. Connect branch circuit to terminal block. Connect incoming ground to ground wire provided on NEMA 3R housing. Connect secondary lamp leads to terminal. See labels on terminal block for additional information..
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
DIM
DIM
COM
LED
LED
-
+
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
8. Re-attach cover. Tighten cover screw.
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2679-00
DIM
1
DIM
COM
1
DIM
+
1
DIM
1
DIM2DIM
COM
2
DIM
+
2
DIM
2
Installation Instructions
Dual Remote Driver with Dimming Controls
NEMA 3R Remote Power Supply
23W-34W Solid State LED
4. Connect conduit connector through female threaded conduit entry.
NOTE: Surface conduit is a common entrance for water if not properly sealed. Seal connector threads and conduit with a suitable sealant (Teflon tape, adhesive, etc.). Sealing the conduit after knockouts are removed is required to maintain warranty.
B
Ground
DIM
DIM2DIM
DIM
1
1
2
COM
COM
DIM
DIM
DIM
DIM
1
2
1
2
+
+
120-208-
120-208-
240-277
240-277
VOLT
7. Terminal A is for circuit branch wiring and fixture
leads. Terminal B is for dimming controls. The grounding screw is located to the upper right of terminal A.
A
LAMP
LAMP2LAMP
LAMP
1
1
2
COM
COM
VOLT
LED
LED
LED
COM
LED
1
2
1
2
+
+
5. Pull branch circuit wiring necessary for installation (By Others). Pull dimming control wiring necessary for installation (By Others).
120-208-
120-208-
240-277
240-277
VOLT
VOLT COM
8. Terminal Block A - Connect branch circuit to terminal block. Connect incoming ground to ground wire provided on NEMA 3R housing. Connect secondary lamp leads to terminal A. See labels on terminal block for additional information.
6. Pull secondary lamp leads necessary for installation though dedicated conduit. (By Others).
NOTE: Failure to comply with specific wiring requirements will void product warranty.
LAMP
1
1
LED
1
1
+
LAMP
COM
LED
LAMP2LAMP
LED
2
+
2
COM
LED
2
For use with 23-34 watt dimming driver.
DIM
1
DIM
1
+
DIM
DIM COM
9. Terminal Block B - Connect incoming dimming
1 1
controls to terminal block. See labels on terminal block for additional information.
DIM2DIM
DIM
2
+
2
COM
DIM
2
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
10. Re-attach cover. Tighten cover screw.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2679-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
NEEDED
FOR
INSTALLATION:
1/8” Allen Wrench
Waterproof Wire Connectors
Level
Phillips Screwdriver
Warning High Voltage Hot Surface
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
By Others
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Suitable for recessed in ground locations
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.
Faceplate
Driver
Assembly
Quick Disconnects
Patented
Hydro-Lock™
Plate
Waterproof Wire
Connectors
Silicone ‘O’ Ring
Concrete Pour Collar
Patented
Stability
HP2RM Housing
Flange
Soil Prep
Conduit trench
A. Determine Soil Type by referencing
DIG-IT Guide.
B. Dig hole 18” wide and 20” deep.
Excavated for Housing
C. Prep soil according to DIG-IT Guide.
Conduit Trench
18”
Dia.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2681-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
Housing Installation
Side Flats
Threaded Entry
1. Connect branch conduit connectors (By Others) to the junction box using either the threaded conduit entries on the bottom of the junction box or through holes drilled into the sides of the junction box.
Flush with finished grade
PROJECT:
TYPE:
2. Place housing in hole. Align junction box in the path of the conduit trench.
3. Insert (4) pieces of ½” EMT conduit through the Stability Flange™. Hammer into substrate until secure.
Leave sufficient clearance to elevate housing
to finished grade.
4. Raise housing on EMT so concrete pour collar is flush with finished grade. Use a level to aid in housing installation.
7. Per DIG-IT Guide, backfill the gap between the bottom of housing and bottom of hole with sand for drainage.
5. When housing is level, tighten screws on Stability Flange™ to secure housing to EMT. Remove excess EMT as needed.
8. For soil installation: Fill and tamp soil to the appropriate height leaving room for sod, pavers, etc. to be level with the top of the temporary cover.
Soil installation is not drive-over rated.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
6. Connect the conduit to the conduit connectors.
9. For concrete installation: Fill the hole around the fixture housing to 12” below the finished grade with clean fill dirt and tamp carefully to prevent settling of fixture. Pour concrete and finish as required flush with the top surface of the temporary cover.
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2681-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
Installation
1. Remove temporary cover.
2. Pull primary branch circuit wiring into junction box.
PROJECT:
TYPE:
3. Make watertight connections using waterproof wire connectors (provided) to leads on the bottom of Patented HydroLock® Barrier Plate Assembly. See wiring diagram(s).
LINE
COM
GROUND
Hydrolock
DIM +
DIM -
FIXTURE
FIXTURE
WIRING DIAGRAM
For use with 23-34 watt dimming driver.
Plate
4. Wipe inside of housing where HydroLock® plate will sit clean of debris before inserting patented HydroLock® plate on to junction box. Align HydroLock® plate with pins in housing and seat it firmly in place.
7. Lower driver assembly into HP2 housing.
5. Turn HydroLock® Barrier Plate clockwise ¼” to lock.
Patented HydroLock® Barrier Plate must be
completely seated to ensure proper seal or water may intrude. This step must be done as stated or you will void your warranty.
8. Attach driver assembly to housing by aligning keyhole notch under one (1) of three (3) #8 screw heads.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
6. Connect driver assembly to Patented HydroLock® Barrier plate with quick disconnects.
9. Tighten the Phillips screws to secure driver plate to housing.
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2681-00
HP2RM SERIES
23W-34W Remote - Solid State LED
Driver Installation Instructions
10. Remove any dirt or debris in O-ring groove near top of housing. Place O-Ring inside of groove.
Failure to clean groove of debris will cause fixture to fail and void product warranty.
PROJECT:
TYPE:
11. Install faceplate using 1/8” Allen wrench and hand-tighten the faceplate screws in a star pattern to 30 in-lbs. min.
Do not use a power tool to install screws. Do
not exceed 40 in-lbs.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASE DATE
11-17-17
REFERENCE NUMBER
INS-2681-00
Installation Instructions
Warning High Voltage
Hot Surface
TOOLS
NEEDED:
By Others
PM3RM TREE STRAP™
Driver Housing
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
Driver
Adjustable Tree Strap
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
PM3RM Housing
Faceplate
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
Installation Instructions
LAMP
BLUE WHITE GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
GroundHotNeutral
LAMP
BLUE WHITE GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
GroundHotNeutral
LAMP
BLUE WHITE GROUND
BARE WIRE
IN UPM
GroundHotNeutral
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3RM TREE STRAP™
Driver Housing
PROJECT:
TYPE:
1. Loosen (6) #10-24 captive screws using a 1/8” Allen wrench to remove faceplate of UPM housing.
4. Thread safety cable through hole on the back of the UPM housing. Feed safety cable through opposing ends of the connector. Pull on wires to assure the connection is secure. Leave enough slack in safety cable for tree growth. Adjustments can be made by pressing release spring with a pin or 3/64” Allen tool.
2. Remove Patented Knockout(s) as necessary from the inside of the UPM housing. Leave remaining unused knockouts in place to maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back into place to renew seal integrity.
5. Connect 3/4” conduit connector through female threaded conduit entry.
NOTE: Surface conduit is a common entrance for water if not properly sealed. Seal connector threads and conduit pipe with a suitable sealant (Teflon tape, adhesive, etc). Sealing the conduit after knockouts are removed is required to maintain warranty.
DIM +
DIM -
LINE
COM
Fixture
Fixture
GROUND IN HOUSING
Remote
Driver
3. Use adjustable strap provided to attach UPM housing to tree. Tighten by pulling on the adjustable strap until secure.
6. Pull branch circuit wiring and dimming control wiring necessary for installation (By Others).
7. Attach tether wire under screw head at the base of the UPM housing and tighten. Slowly lower the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety cable. Do not add weight to, or drop faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
WIRING DIAGRAM
8. Use waterproof wire connectors (By Others) to connect driver primary leads to branch circuit wires. Connect incoming ground to ground wire provided in UPM housing. Connect incoming dimming control wires to driver dimming controls. See wiring diagram.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
9. Remove two (2) #8-32 screws in UPM housing using Phillips screwdriver.
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
LAMP
BLUE WHITE GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
LAMP
BLUE WHITE GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
Installation Instructions
10. Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver.
11. Reinstall #8-32 screws on other side of driver and tighten to secure driver to UPM housing.
PROJECT:
TYPE:
12. Make sure UPM housing gasket is free of any dirt or debris. Attach the faceplate by tightening the (6) #10-24 captive screws evenly using a 1/8” Allen wrench.
PM3RM TREE STRAP™
Driver Housing
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
Installation Instructions
Warning High Voltage
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
PM3RM SURFACE MOUNT™
Driver Housing
NEEDED
INSTALLATION:
Hot Surface
By others
FOR
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
1/4” Drill Bit and Drill
Mounting Hardware
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
PM3RM Housing
Surface Mount
Knockouts
Faceplate
Driver
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
GroundHotNeutral
LAMP
BLUE WHITE GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
Installation Instructions
1. Prepare final mounting position according to designed lighting plan.
PM3RM SURFACE MOUNT™
PROJECT:
TYPE:
2. Drill holes into surface for ¼” fasteners (By Others) on locations required for mounting via tabs.
Driver Housing
3. Loosen (6) #10-24 captive screws using a 1/8” Allen wrench to remove faceplate of UPM housing.
4. Remove Patented Knockout(s) as necessary from the inside of the UPM housing. Leave remaining unused knockouts in place to maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back
7. Pull branch circuit wiring and dimming control wiring necessary for installation (By Others.)
5. Attach the UPM housing at mounting brackets with ¼” fasteners (By Others). Use suitable mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting brackets with ¼” holes.
6. Connect 3/4” conduit connector through female threaded conduit entry.
NOTE: Surface conduit is a common entrance for water if not properly sealed. Seal
connector threads and conduit with a suitable sealant (Teflon tape, adhesive, etc.). Sealing the conduit after knockouts are removed is required to maintain warranty.
DIM +
DIM -
LINE
COM
Fixture
Fixture
Remote
Driver
GROUND IN HOUSING
8. Attach tether wire under screw head at the base of the UPM housing and tighten. Slowly lower the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a safety cable. Do not add weight to, or drop faceplate.
WIRING DIAGRAM
9. Use waterproof wire connectors (By Others) to connect driver primary leads to branch circuit wires. Connect incoming ground to ground wire provided in UPM housing. Connect incoming dimming control wires to driver dimming controls. See wiring diagram.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
Installation Instructions
PM3RM SURFACE MOUNT™
Driver Housing
PROJECT:
TYPE:
10. Remove two (2) #8-32 screws in UPM housing using Phillips screwdriver.
11. Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver.
12. Reinstall two (2) #8-32 screws on other side of driver and tighten to secure driver to UPM housing.
13. Make sure UPM housing gasket is free of any dirt or debris. Attach the faceplate by tightening the (6) #10-24 captive screws evenly using a 1/8” Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
Installation Instructions
Warning High Voltage
Hot Surface
PM3RM ROUND CAMLOCK™
Driver Housing
NEEDED
FOR
INSTALLATION:
By others
1/8” & 9/64” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver
Level
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
Universal Mounting Ring™
CamLock™
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
Driver
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
B-K LIGHTING
PM3RM Housing
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
Faceplate
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
Installation Instructions
Horizontal
Vertical
GroundHotNeutral
GroundHotNeutral
BC
Horizontal
Vertical
GroundHotNeutral
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
1. Install standard 4” octagonal/round recessed junction box in the final fixture location according to designed lighting plan.
2. Pull branch circuit wiring and dimming control wiring necessary for installation (By Others.)
PM3RM ROUND CAMLOCK™
Driver Housing
PROJECT:
TYPE:
Horizontal
Install universal mounting ring.
3.
IMPORTANT!! Orientation of universal ring will affect orientation of UPM! Take note of
mounting plate holes (indicated with arrows) on the universal ring holes to mount UPM in correct orientation.
Vertical
4. Feed branch circuit wiring and dimming control wiring through mounting plate with CamLock™ assembly. Attach mounting plate with supplied (2) #10-24 stainless steel hex drive fasteners to universal ring using 1/8” Allen wrench.
8. Attach tether wire under screw head at the base of the UPM housing. Slowly lower the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a safety cable. Do not add weight to, or drop faceplate.
A
5. Feed branch circuit wiring and dimming control wiring into UPM housing. Install housing on CamLock™ at 90° to finished orientation as shown. (Figure A)
6. Rotate housing 90° counter-clockwise (Figure B). Tighten set screw with 5/64” Allen wrench on outside of UPM housing to lock in place.
(Figure C)
DIM +
DIM -
LINE
COM
Fixture
Fixture
GROUND IN HOUSING
WIRING DIAGRAM
9. Use waterproof wire connectors (By Others) to connect driver primary leads to branch circuit wires. Connect incoming ground to ground wire provided in UPM housing. Connect incoming dimming control wires to driver dimming controls See wiring diagram.
Remote
Driver
7. If UPM housing is not level, remove UPM housing; loosen but DO NOT REMOVE (2) #8-32 screws with 9/64” Allen wrench on CamLock™ assembly. Adjust CamLock™ assembly up to 30° as needed to level. Tighten the screws and reattach UPM housing.
10. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening the (6) #10-24 captive screws evenly using a 1/8” Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2187-00
Installation Instructions
Warning High Voltage
Hot Surface
TOOLS
NEEDED:
By Others
PM3DRM TREE STRAP™
Driver Housing
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
Driver
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
Faceplate
Failure to comply with specific wiring
requirements will void product warranty.
Adjustable Tree Strap
PM3DRM Housing
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
Installation Instructions
GroundHotNeutral
GroundHotNeutral
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3DRM
PM3DRM TREE STRAP™
Driver Housing
PROJECT:
TYPE:
1. Loosen (6) #10-24 captive screws using a 1/8” Allen
4. Thread safety cable through hole on the back of the
wrench to remove faceplate of UPM housing.
UPM housing. Feed safety cable through opposing ends of the connector. Pull on wires to assure the connection is secure. Leave enough slack in safety cable for tree growth. Adjustments can be made by pressing release spring with a pin or 3/64” Allen tool.
2. Remove Patented Knockout(s) as necessary from the inside of the UPM housing. Leave remaining unused knockouts in place to maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back into place to renew seal integrity.
5. Connect 3/4” conduit connector through female threaded conduit entry.
NOTE: Surface conduit is a common entrance for water if not properly sealed. Seal connector threads and conduit pipe with a suitable sealant (Teflon tape, adhesive, etc). Sealing the conduit after knockouts are removed is required to maintain warranty.
Fixture
Fixture
DIM +
DIM -
Remote
Driver
3. Use adjustable strap provided to attach UPM housing to tree. Tighten by pulling on the adjustable strap until secure.
6. Pull branch circuit wiring and dimming control wiring necessary for installation (By Others).
7. Attach tether wire under screw head at the base of the UPM housing and tighten. Slowly lower the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety cable. Do not add weight to, or drop faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
LINE
COM
DIM +
Remote
DIM -
Driver
Fixture
Fixture
GROUND IN HOUSING
WIRING DIAGRAM
8. Use waterproof wire connectors (By Others) to connect driver primary leads to branch circuit wires. Connect incoming ground to ground wire provided in UPM housing. Connect dimming control wiring to driver dimming leads. See wiring diagram.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
9. Remove two (2) #8-32 screws in UPM housing using Phillips screwdriver.
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
PM3DRM TREE STRAP™
Driver Housing
Installation Instructions
11. Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver.
12. Reinstall #8-32 screws on other side of driver and tighten to secure driver to UPM housing.
PROJECT:
TYPE:
13. Make sure UPM housing gasket is free of any dirt or debris. Attach the faceplate by tightening the (6) #10-24 captive screws evenly to 30 in-lbs using a 1/8” Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
Installation Instructions
Warning High Voltage
Hot Surface
PM3DRM SURFACE MOUNT™
Driver Housing
NEEDED
FOR
INSTALLATION:
By others
1/8” Allen Wrench
Waterproof Wire Connectors
Hammer
Phillips Screwdriver
1/4” Drill Bit and Drill
Mounting Hardware
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
Surface Mount
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
Failure to comply with specific wiring
requirements will void product warranty.
PM3DRM Housing
Driver
Faceplate
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
GroundHotNeutral
LAMP
BLUE WHITE GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3DRM
Installation Instructions
1. Prepare final mounting position according to designed lighting plan.
PM3DRM SURFACE MOUNT™
PROJECT:
TYPE:
2. Drill holes into surface for ¼” fasteners (By Others) on locations illustrated on template.
Driver Housing
3. Loosen (6) #10-24 captive screws using a 1/8” Allen wrench and disconnect quick disconnect to remove faceplate of UPM housing.
4. Remove Patented Knockout(s) as necessary from the inside of the UPM housing. Leave remaining unused knockouts in place to maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back into place to renew seal integrity.
5. Attach the UPM housing at mounting brackets with ¼” fasteners (By Others). Use suitable mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting brackets with ¼” holes.
6. Connect 3/4” conduit connector through female threaded conduit entry.
NOTE: Surface conduit is a common entrance for water if not properly sealed. Seal
connector threads and conduit with a suitable sealant (Teflon tape, adhesive, etc.). Sealing the conduit after knockouts are removed is required to maintain warranty.
Fixture
Fixture
DIM +
DIM -
LINE
COM
DIM +
DIM -
Fixture
Fixture
GROUND IN HOUSING
Remote
Driver
Remote
Driver
7. Pull branch circuit wiring and incoming dimming control wiring necessary for installation (By Others.)
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
8. Attach tether wire under screw head at the base of the UPM housing and tighten. Slowly lower the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is designed as an installation aid and NOT a safety cable. Do not add weight to, or drop faceplate.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
WIRING DIAGRAM
9. Use wire connectors (By Others) to connect driver primary leads to branch circuit wires. Connect incoming ground to ground wire provided in UPM housing. Connect incoming dimming control wiring to driver dimming leads.
See wiring diagram.
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
Installation Instructions
PM3DRM SURFACE MOUNT™
Driver Housing
PROJECT:
TYPE:
10. Remove two (2) #8-32 screws in UPM housing using Phillips screwdriver.
11. Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver.
12. Reinstall #8-32 screws on other side of driver and tighten to secure driver to UPM housing.
13. Make sure UPM housing gasket is free of any dirt or debris. Attach the faceplate by tightening the (6) #10-24 captive screws evenly using a 1/8” Allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
Installation Instructions
Warning High Voltage
Hot Surface
NEEDED
INSTALLATION:
By others
PM3DRM CAMLOCK™
Driver Housing
FOR
1/8” & 9/64” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver
Level
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
REMOTE WIRING
LED Driver
Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations:
• Do not exceed 50 foot overall wiring distance using 12 gauge copper wire.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Knockouts
Driver
• Do not block light emanating from product in whole or part, as this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot lens or fixture body.
• Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
Faceplate
Failure to comply with specific wiring
requirements will void product warranty.
Universal Mounting
CamLock™
Ring™
PM3DRM Housing
* UPM is covered in whole or in part by US patent #6,940,012
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
B-K LIGHTING
www.bklighting.com • info@bklighting.com
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
Installation Instructions
Horizontal
Vertical
GroundHotNeutral
GroundHotNeutral
BC
Horizontal
Vertical
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
PM3DRM
PM3DRM ROUND CAMLOCK™
Driver Housing
PROJECT:
TYPE:
1. Install standard 4” octagonal/round recessed junction box in the final fixture location according to designed lighting plan.
2. Pull branch circuit wiring and dimming control wiring necessary for installation (By Others.)
4. Feed branch circuit wiring and dimming control wiring through mounting plate with CamLock™ assembly. Attach mounting plate with supplied (2) #10-24 stainless steel hex drive fasteners to universal ring using 1/8” Allen wrench.
Horizontal
Vertical
Install universal mounting ring.
3.
IMPORTANT!! Orientation of universal ring will affect orientation of UPM! Take note of mounting
plate holes (indicated with arrows) on the universal ring holes to mount UPM in correct orientation.
A
5. Feed branch circuit wiring and dimming control wiring into UPM housing. Install housing on CamLock™ at 90° to finished orientation as shown. (Figure A)
6. Rotate housing 90° counter-clockwise (Figure B). Tighten set screw with 5/64” Allen wrench on outside of UPM housing to lock in place. (Figure C)
Fixture
Fixture
DIM +
DIM -
Remote
Driver
7. If UPM housing is not level, remove UPM housing; loosen but DO NOT REMOVE (2) #8-32 screws with 9/64” Allen wrench on CamLock™ assembly. Adjust CamLock™ assembly up to 30° as needed to level. Tighten the screws and reattach UPM housing.
8. Attach tether wire under screw head at the base of the UPM housing. Slowly lower the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a safety cable. Do not add weight to, or drop faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
LINE
COM
DIM +
Remote
DIM -
Driver
Fixture
Fixture
GROUND IN HOUSING
WIRING DIAGRAM
9. Use wire connectors (By Others) to connect driver primary leads to branch circuit wires. Connect incoming ground to ground wire provided in UPM housing. Connect incoming dimming control wiring to driver dimming leads.
See wiring diagram.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
10. Make sure UPM housing gasket is free of any dirt or debris. Attach the faceplate by tightening the (6) #10-24 captive screws evenly using a 1/8” Allen wrench.
RELEASED
12-8-17
REFERENCE NUMBER
INS-2188-00
Loading...