Read this manual carefully before installing, operating or servicing these pump models.
Observe all safety information. Failure to comply with instructions may result in personal
injury and/or property damage. Please retain these instructions.
OIL FILL QUANTITY/TYPE ....................................................................................................................................... 5
POSITIONING THE PUMP ....................................................................................................................................... 6
PUMP WILL NOT RUN ........................................................................................................................................... 11
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY ............................................................................... 12
SERVICING YOUR SUBMERSIBLE PUMP............................................................................................................ 12
MAINTAINING YOUR PUMP .................................................................................................................................. 12
CHANGING SEAL OIL ............................................................................................................................................ 13
EXPLODED VIEW OF SV400F.................................................................................................................................... 14
EXPLODED VIEW OF SV750CF ................................................................................................................................. 15
EXPLODED VIEW OF SV1500CF ............................................................................................................................... 16
SVF SERIES PARTS LIST .......................................................................................................................................... 17
SINGLE PHASE WIRING DIAGRAMS 115V & 230V .................................................................................................. 18
SEAL MINDER® .......................................................................................................................................................... 20
SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH .......................................................................................... 20
WARRANTY AND LIMITATION OF LIABILITY ............................................................................................................ 21
START-UP REPORT FORM ........................................................................................................................................ 22
This Installation, Operation and Maintenance manual provides important information on
safety and the proper inspection, disassembly, reassembly and testing of the BJM
Pumps SVF Series submersible pump. This manual also contains information to
optimize performance and longevity of your BJM Pumps submersible pump. The F
Series FARHRENHEIT™ pumps are engineered to pump water based liquids up to 200°
Fahrenheit (93°C).
The submersible SVF Series pumps are designed to pump municipal and
industrial wastewater. The SVF Series pumps are not explosion-proof. They are
not designed to pump volatile or flammable liquids.
Note: Consult a chemical resistance chart for compatibility between pump
materials and liquid before operating pump.
If you have any questions regarding the inspection, disassembly, reassembly or testing
please contact your BJM Pumps distributor, or BJM Pumps, LLC.
BJM Pumps, LLC
123 Spencer Plain Rd
Old Saybrook, CT 06475, USA
Information, including pump data sheets and performance curves, is also available on
our web site: www.bjmpumps.com
For assistance with your electric power source, please contact a certified electrician.
Please pay attention to the following alert notifications. They are used to notify
operators and maintenance personnel to pay special attention to procedures, to avoid
causing damage to the equipment, and to avoid situations that could be dangerous to
personnel.
NOTE: Instructions to aid in installation, operation, and maintenance or which
clarify a procedure.
Immediate hazards that WILL result in severe personal injury or
death. These instructions describe the procedure required and the injury which will
result from failure to fol low the procedure.
Hazards or unsafe practices that COULD result in severe personal
injury or death. These instructions describe the procedure required, and the injury which
could result from fail ur e to foll ow the procedure.
Hazards or unsafe practices which COULD result in personal injury
or product or property damage. These instructions describe the procedure required and
the possible damage which could result from failure to follow the procedure.
4
SAFETY
Pump installations are seldom identical. Each installation and application can vary due
to many different factors. It is the owner/service mechanics responsibility to repair,
service, and test to ensure that the pump integrity is not compromised according to this
manual.
Risk of electric shock – this pump has not been investigated for use
in swimming pool areas.
Do not pump flammable, inflammable or volatile liquids. Death
or serious injury will result.
Before attempting to open or service the pump:
1) Familiarize yourself with this manual.
2) Unplug or disconnect the pump power cable to ensure that the pump will remain
inoperative.
3) Allow the pump to cool if overheated.
Do not operate the pump with a worn or damaged electric power
cable. Death or serious injury could occur.
Never attempt to alter the length or repair any power cable with a
splice. The pump motor and pump motor and cable must be completely waterproof.
Damage to the pump or personal injury may result from alterations.
After the pump has been installed, make sure that the pump and all
piping are secure before operation.
Do not lift the pump by the power cable piping or discharge hose.
Attach proper lifting equipment to the lifting handle (or lifting rings) fitted to the pump. Do
not suspend the pump by the power cable.
Obtain the services of a qualified electrician to troubleshoot, test
and/or service the electrical components of this pump.
Pumps and related equipment must be installed and operated
according to all national, local and industry standards.
5
INSPECTION
Review all safety information before servicing pump.
The following are recommended installation practices/procedures for the pump. If there
are questions in regards to your specific application, contact your local BJM Pumps
distributor or BJM Pumps, LLC.
PRE-INSTALLATION INSPECTION
1) Check the pump for damage that may have occurred during shipment.
2) Inspect the pump for any cracks, dents, damaged threads, etc.
3) Check power cable (and seal minder cable, if installed) for any cuts or damage.
4) Check for, and tighten any hardware that appears loose.
5) Carefully read all tags, decals and markings on the pump.
6) Important: Always verify that the pump nameplate, amps, voltage, phase, and
HP ratings match your control panel and power supply.
Warranty does not cover damage caused by connecting pumps and controls to an
incorrect power source (voltage/phase supply). Record the model numbers and serial
numbers from the pumps and control panel on the front of this instruction manual for
future reference. Give it to the owner or affix it to the control panel when finished with
the installation.
If anything appears to be abnormal, contact your BJM Pumps distributor or BJM Pumps,
LLC. If damaged, the pump may need to be repaired before use. Do not install or use
the pump until appropriate action has been taken.
Lubrication:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated
from the factory. Seal oil should be checked once per year. See table below.
Oil in seal chamber
Model U.S. fl. oz. cc. Type of oil
SV400F 5.1 150 ISO 32 NSF Food Grade Mineral Oil
SV750CF 9.3 275 ISO 32 NSF Food Grade Mineral Oil
SV1500CF 9.3 275 ISO 32 NSF Food Grade Mineral Oil
Note: The stator on this model is oil filled. This needs to be changed annually
when the seal oil is changed. With the power cable entry removed, fill the motor
chamber with oil to a level that insures the oil is covering the motor windings by
OIL FILL QUANTITY/TYPE
6
½”, and that will be above the upper bearing. Do not overfill, an air gap of 10-15%
must be maintained for heat expansion.
PUMP INSTALLATION
SVF Series pumps have been evaluated for use with water or water based solutions.
Please contact the manufacturer for additional information.
Risk of electric shock. Pump models; SV400, SV750 (115v) are
supplied with a grounding conductor and grounding-type attachment plug. 230V singl e
phase pumps and all three phase pumps do not come with electric plug connectors. To
reduce the risk of electric shock, be certain that it is connected only to a properly
grounded, grounding-type receptacle.
Lifting:
Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of
the pump.
Do not lift the pump by the power cable or discharge hose/piping.
Proper lifting equipment (rope/chain) must be used.
POSITIONING THE PUMP
BJM Pumps, SVF Series pumps are designed to operate fully or partially submerged.
Avoid running the pump dry for extended periods of time. Refer to data sheet for
minimum submersion depth for your particular model. Data sheets can be obtained
online at www.bjmpumps.com or by calling BJM Pumps, LLC at 860-399-5937. As a
general rule, SVF Series side discharge pumps can pump down to a level above the
suction cover. Pumping lower than the cover will permit air to enter the pump and
cavitate, lose prime or become air bound.
• Do not run the pump dry.
• Pump liquid should not exceed a maximum temperature of 104°F.
• Never place the pump on loose or soft ground. The pump may sink, preventing
water from reaching the impeller. Place on a solid surface or suspend the pump
with a lifting rope/chain. The SVF Series pumps are provided with a suction
strainer to prevent large solids from clogging the impeller. Any spherical solids
which pass through the strainer should pass through the pu mp.
• For maximum pumping capacity, use the proper size non-collapsible hose or rigid
piping. A check valve may be installed after the discharge to prevent back flow
when the pump is shut off.
7
PUMP ROTATION
If wired properly to the control, the single phase BJM Pumps SV-F Series pump should
operate with the correct pumping rotation. Verification is recommended prior to installing
into the sump basin.
Two ways to check the correct pump rotation:
1. By looking at the impeller; the rotation of the impeller should be counter
clockwise as shown in the picture below.
2. By looking from the top of the pump. Since the impeller cannot be seen, the best
way to check the rotation is to check the kick back motion of the pump when the
pump just starts. The kick back motion of the pump should be counter clockwise
as shown in the picture below.
8
PUMP OPERATION
This pump is designed to handle dirty water that contains some
solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.
Do not operate this pump where explosive vapors or
flammable material e xist. Death or Serious injury may result.
TYPICAL MANUAL DEWATERING INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
MANUAL OPERATION
All SVF models are provided with a 50’ (15 m) power cable. NEVER splice the power
cable due to safety and warranty considerations. Always keep the plug end dry.
Do not alter the length or repair any power cable with a splice. The
pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.
The BJM Pump s, SV-F series pumps require a special control that contains the starting
components, thermal sensor and Seal Minder connections. These pumps cannot be
directly connected to a power source.
TYPICAL AUTOMATIC DEWATERING INSTALLATION
9
NOTE: Maximum recommended starts should not exceed 10 times per hour.
STOPPING
To stop the pump (manual and automatic mode),turn the pump off at the control, turn off
the breaker, and/or turn the power source off (generator).
CONTROL PANELS CONNECTION OPTIONS
Use with approved motor control that matches motor input in full
load amperes. “UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU
COURANT Á PLEINE CHARGE DU MOTEUR.”
BJM Pumps has been evaluated for use with water or water based solutions. Please
contact the manufacturer for additional information.
SINGLE PHASE WIRING INSTRUCTIONS
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE H ANDLING. Single phase pumps are supplied
with a three prong grounded plug to help protect you against the possibility of electrical
shock. DO NOT UNDER ANY CIRCUMST ANCES REMOVE THE GROUND PIN. The
three prong plug must be inserted into a mating three prong grounded receptacle. IF
the installation does not have such a receptacle it must be changed to the proper type,
wired and grounded in accordance with the National Electrical Code and all applicable
local codes and ordinances.
“Risk of electrical shock” Do not remove power supply cable and
strain relief or connect conduit directly to the pump.
Installation and checking of electrical circuits and hardware should
be performed by a qualified licensed electrician.
10
Figure 1 SV400F-115 and SV750F-115 control
Figure 2 SV750F-230 and SV1500F-230 con tro l
11
OPTIONAL FLOAT CONNECTION
BJM Pumps utilizes a control for all of the single phase “F” series pumps. The wiring
diagram included in this manual (and with the control) should be followed to properly
connect the pump power and sensor leads to the control, and the power supply to the
control. Care should be taken to make sure all of the connections are proper and that
the system is properly grounded. The control can be utilized as a portable control or as
a permanently mounted control enclosure. All Connections should be done to meet the
National Electric Cod e and all appl i cabl e local codes and ordinances.
The BJM Pumps control is supplied as a manual ON/OFF control. A wide angle float
can be wired in series with the thermal sensors to allow the pumps to operate in an
automatic mode. See the wiring diagram provided in this manual for proper conn ec ti on .
A separate alarm control with float is available as an option from BJM Pumps.
TROUBLE SHOOTING
Disconnect the power source to the pump BEFORE attempti ng
any type of trouble shooting, service or repair.
PUMP WILL NOT RUN
1. Check power supply (fuses, breaker). Reset power.
2. Blocked impeller. Remove strainer, check and clean.
3. Defective cable or incorrect wiring.
4. Strainer clogged. Check and clean as necessary.
5. Float switch tangled/obstructed. Clean and free float switch from obstruction.
6. Float switch defective. Replace float switch.
7. Capacitor or start relay in control failed.
8. Thermal sensor switch is open/or failed.
12
Warning: Pump will restart automatically when motor o ver-heat protection switch
cools.
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY
1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe.
2. Worn impeller and/or suction cover. Inspect and replace as necessary.
3. Pump overloaded due to liquid pumped being too thick.
4. Pumping air. Check liquid level and position of pump.
5. Excessive voltage drops due to long cables.
6. Pump running backwards, check rotation.
SERVICING YOUR SUBMERSIBLE PUMP
Pump should be disconnected from the electric power supply before proceeding to do
any service or maintenance.
The design of the “F” series high temperature pump models is unique and
requires specific knowledge to perform the proper assembly. BJM Pumps
recommends that all electrical service work be performed at the factory to insure
that the materials and assembly methods meet BJM standards.
MAINTAINING YOUR PUMP
• Pump should be disconnected from the electric power supply before proceeding
to do any service or maintenance.
• Pump should be inspected at regular intervals (At least 2 times per year).
• More frequent inspections are required if the pump is used in a harsh
environment.
• Preventative maintenance should be performed to reduce the chance of
premature failure.
• Worn impellers and lip seals should be replaced.
• Cut or cracked power cables must be replaced. (Never operate a pump with a
cut, cracked or damaged power cable.)
• Seal oil should be checked once per year.
• Maintenance should always be done when taking a pump out of service before
storage.
1) Clean pump of dirt and other build up.
2) Check condition of oil around the shaft seals.
3) Check hydraulic parts: check for wear.
4) Inspect power cable. Make sure that it is free of nicks or cuts.
13
CHANGING SEAL OIL
Changing the seal oil in the SVF series pumps is very easy.
1) Make sure that the pump cable is disconnect ed fro m the power source.
2) Lay the pump down on its side.
3) Remove the screws that hold the bottom plate in place.
4) Remove botto m plate .
5) Remove screws holding the suction cover.
6) Remove the suction cover.
7) Remove the impeller.
8) Remove the inspection screw for the oil chamber (pos#50-08). Pour
out a small sample of the oil. If it is milky white, or contains water, then
the oil and possible, the mechanical seal, should be changed. If an oil
change is needed:
9) Remove the screws that hold the oil chamber cover in place & remove
the oil.
10) Replace the mechanical seal i f necess ar y.
11) Replace the oil.
12) Reassemble the pump.
14
EXPLODED VIEW OF SV400F
15
EXPLODED VIEW OF SV750CF
16
EXPLODED VIEW OF SV1500CF
17
Pump Mode l SV400F SV750CF SV1500CF
Pos. No. P art Descripti o nItem #Item #Item #
01-2Bot t om Plate202868 202037202035
05Impeller V ort ex202114 202115202116
07Pump Housing w/ B ottom Plate202185 203016202187
07-1O-Ring (Kit Only )KitKitKit
08Oil Chamber Cover202207 203045202211
08-1O-Ring (Kit Only )KitKitKit
09Lip Seal F K M202230 202233202233
10Shaft S l eeve202258--
13Mec hani c al Seal FK M **202260 200500200500
14Lower Ball Bearing200957 200958200958
17Rotor w/ S haft 115/ 230V, 1 PH202302 204060-
17Rotor w/ S haft 230V , 1 PH--204109
18St at or Coi l w/ Cas i ng 115V, 1PH (High-Temp)201032 201036-
18St at or Coi l w/ Cas i ng 230V, 1PH (High-Temp)201033 201037201040
20Upper Ball Bearing200957 200967200967
21AOil Chamber Housing202796 203018203019
21A-1O-Ring (K i t Onl y)KitKitKit
21BMotor Cover Upper202365 202368202368
22Motor Cover Plate202380--
26Pump Top Cover
203120 202433202433
26-1O-Ring (Kit Only )Kit Kit Kit
27Power Cable w/ G land-115V,1P H (High-Temp)202785 202783-
27Power Cable w/ G land-230V, 1P H (High-Temp)202785 202784202783
27-1O-Ring (Kit Only )KitKitKit
27-2Sens or Cable (Hi gh-Temp)-201743201743
27-2-1O-Ring (Kit Only )-KitKit
31DOi l S ensor w/Wire202409 202409202409
31EGround Wi re w/ Ri ng Term.203145 203145203145
32Power Cord Line Clip203161 203161203161
33Sens or Cord Line Cl ip-203163203163
34Handle202517 202517202517
35Rods B ol t s 202665 202666202668
38Discharge Nipple 2"202531 202531-
38Discharge Nipple 3"-202534-
38EDischarge Elbow-202558202557
38E-1Gas ket, Disch. Elbow, F K M-203209203209
38FDischarge Fl ange 2", 45°202569--
38FB ol t - Suction Cover202562 202543-
38FDischarge Fl ange 3"-202545203188
38FDischarge Fl ange 4"--202606
38FDischarge Connec tion, 4" F NP T-202552-
38F-1Gasket, Disch. Flange, FKM203207 202660203209
50-01-2 Sc rew for Bot t om Plate203216 203216203216
50-07S crew for Pump Housi ng203238 203283203283
50-08S crew for Oil Chamber Cover203215 203219203219
50-11Sc rew for Oil Fill203218 203218203218
50-11-1 O-Ring (Kit O nl y)KitKitKit
50-12S crew for Press ure Chec k203218 203218203218
50-12-1 O-Ring (Kit O nl y)KitKitKit
50-22S crew for Cover Plate203214--
50-27S crew for Power Cord203295 203216203216
50-27-2 Screw-203216203216
50-31EScrew for Ground W i re202692 202692202692
50-32S crew for Line Clip203214 203214203214
50-33S crew for Line Clip-203214203214
50-34B ol t for Handle203219 203219203219
50-38EBolt for Dis charge Elbow-203267203267
50-38FBol t for Discharge Fl ange203230 203253203277
202777 202798202798
O-Ri n g Kit - FKM
SVF SERIES PARTS LIST
18
SINGLE PHASE WIRING DIAGRAMS 115V & 230V
MODELS SV400F
19
MODELS SV750CF, SV1500CF
20
SEAL MINDER®
SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH
(For high temperature single phase pump models)
Seal Minder:
Also known as a seal failure circuit (or moisture detection circuit) is designed to inform the pump
operator that there is moisture within the oil chamber. This early warning can allow the operator to
schedule repair & inspection on the pump. The Seal Minder sensor probe is inside the oil chamber.
(The oil chamber houses the mechanical seals that are cooled & lubricated by oil). The Seal Minder,
when properly connected to a control panel, can help indicate seal failure. The Seal Minder cable
requires a seal fail circuit in control panel for warning signal.
Along, with the Seal Minder, the Fahrenheit™ Series high temperature pumps also feature
thermal temperature sensor switches that are imbedded into the motor stator windings. Two switches
are imbedded into the stator windings and wired in series. The leads are connected to the pump
control panel through the sensor cable. If the windings would see a temperature above 300 degrees
F, then the switch(s) would open and cut power to the pump. Once the temperature dropped below
300 degrees F, the switch(s) would reset, and the pump would be returned to a state of operation.
This feature is designed to prevent damage to the stator winding and allow for longer pump life.
The sensor cable consists of four leads, two are connected to the Seal Minder, and two are
connected to the thermal sensor switches located in the stator windings (Note on 400 models the
sensor and power are in a single cable).These four leads run to the pump control panel and connect
to the proper connections points for seal alarm and thermal cut off. The black and white wires on 7501500 models, black with white stripes and white with black stripes on 400 models; are for the Seal Minder connections and the thermal sensors will be connected to the yellow and red wires on 7501500 models, yellow and red with yellow stripes on 400 models (see details on wiring diagram). The
single phase wiring diagram shown earlier in the manual will give a guide to the connections in the
control panel. The manual for the control panel should be consulted for the exact connections.
The sensor cable with Seal Minder and thermal sensor switch connections is standard on all
Fahrenheit™ Series high temperature pumps (Note the 400 models have a different wire color
code in the single cable design). The cable is designed for a high temperature environment. The
proper replacement part can be found parts list found in this manual. BJM Pumps, can supply a
control with the Seal Minder and Thermal sensor switch option. BJM Pumps requires the Seal Minder
and thermal sensor switches be used. Failure to connect or misuse of these devices will void warranty.
21
BJM PUMPS, LLC
123 Spencer Plain Road
Old Saybrook, CT 06475, U.S.A.
WARRANTY AND LIMITATION OF LIABILITY
Unless otherwise expressly authorized in writing, specifying a longer or shorter period, BJM
Pumps, LLC warrants for a period of eighteen (18) months from t he date of shipment from the
Point of Shipment, or one (1) year from the date of installation, whichever occurs first, that all
products or parts thereof furnished by BJM Pumps, LLC under the brand name BJM Pumps,
hereinafter referred to as the “Product” are free from defects in materials and workmanship and
conform to the applicable specification.
BJM Pumps, LLC’s liability for any breach of this warranty shall be limited solely to replacement
or repair, at the sole option of BJM Pumps, LLC, of any part or parts of the Product found to be
defective during the warranty period, provided the Product is properly installed and is being
used as originally intended. Any breach of this warranty must be reported to BJM Pumps, LLC
or BJM Pumps, LLC’s authorized service representative within the aforementioned warranty
period, and defective Product or parts thereof must be shipped to BJM Pumps, LLC or BJM
Pumps, LLC’s authorized representative, transportation charges prepaid. Any cost associated
with removal or installation of a defective Product or part is excluded.
IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY
OF BJM PUMPS, LLC’S DISTRIBUTORS AND CUSTOMERS. UNDER NO CIRCUMSTANCES
SHALL BJM PUMPS, LLC BE LIABLE FOR ANY COSTS, LOSS, EXPENSE, DAMAGES,
SPECIAL DAMAGES, INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING
DIRECTLY OR INDIRECTLY FRO M THE DESIGN, MANUFACT URE, SALE, USE OR REPAIR
OF THE PRODUCT, WHETHER BASED ON WARRANTY, CONTRACT, NEGLIGENCE, OR
STRICT LIABILITY. IN NO EVENT WILL LIABILITY EXCEED THE PURCHASE PRICE OF
THE PRODUCT.
THE WARRANTY AND LIMITS OF LIABILITY CONTAINED HEREIN ARE IN LIEU OF ALL
OTHER WARRANTIES AND LIABILITIES, EXPRESSED OR IMPLIED. ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY DISCLAIMED BY BJM PUMPS, LLC AND EXCLUDED F ROM THIS WARRANTY.
BJM Pumps, LLC neither assumes, nor authorizes any person to assume for it, any other
warranty obligation in connection with the sale of the Product. This warranty shall not apply to
any Product or parts of Product which have (a) been repaired or altered outside of BJM Pumps,
LLC’s facilities unless such repair was authorized in advance by BJM Pumps, LLC or by its
authorized representative; or (b) have been subject to misuse, negligence or accident; or (c)
have been used in a manner contrary to BJM Pumps, LLC’s instruction.
In any case of products not manufactured and sold under the BJM Pumps, LLC brand nam e,
there is no warranty from BJM Pumps, LLC; however BJM Pumps, LLC will extend any warranty
received from BJM Pumps, LLC’s supplier of such products.
START-UP REPORT FORM
Rotation: Direction of Impeller Rotation (view ed fro m bott om)
Resistance of ground circuit between control panel and outside of pumps
MEG
Was equipment stored
START-UP REPORT FORM
This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a
later date (if needed).
BJM Pumps, LLC
123 Spencer Plain Road
Old Saybrook, CT. 06475
Pump Owner’s Name
Location of Installation Date of Installation:
Dealer Dealer Phone ( )
Date of Purchase
Model Serial No
Voltage Phase Hertz HP
Does impeller turn freely by hand? Yes No
Condition of Equipmen t New Good Fair Poor
Condition of Cable Jacket New Good Fair Poor
(Use C/W for clockwise, CC/W for counterclockwise):
Resistance of cable and Pump Motor (measured at pump control)
Red-Blackohms
Red-Whiteohms
White-Blackohms
Ohms
OHM CHECK OF INSULATION
Red to ground White to ground Black to ground
Condition of location at start-up Dry Wet Muddy
If YES, length of storage:
Liquid being pump
Debris in bottom of station? Yes No
Yes No.
START-UP REPORT FORM
Liquid level controls: Model
Float Operation Check
Tip lowest float (stop float), all pumps should remain off.
Tip fourth float (and stop float), high level alarm on (omit on simplex).
NOTE: At no time should hole be made in top of control panel, unless proper sealing
devices are utilized.
SINGLE PHASE
Voltage supply at panel line connection, pump on
L1
L2
THREE PHASE
Voltage supply at panel line connection, pump off
Voltage supply at panel line connection, pump on
Are guide rails vertical? Yes No
Is base elbow installed level? Yes No
Is control installed away from turbulence? Yes No
Tip second float (and stop float), one pump comes on.
Tip third float (and stop float), both pumps on (alarm on simplex).
Check here if using manual on/off only.
Does liquid level ever drop below volute top? Yes No
Control Panel MFG & mod el no.
Number of pumps operated by control pan el
Short Circuit protection: Type:
Number and size of short circuit device(s) Amp ratin g:
Overload type: Size: Amp ratin g:
Do protective devices comply with pump motor amp
Yes No
rating?
Are all pump connections tight? Yes No
Is the interior of the panel dry?
If No, correct moisture problem.
Yes No
Electrical readings
Voltage supply at panel line connection, pump off L1 L2
Amperage load connecti on, pu mp on L1 L2
L1-L2 L2-L3 L3-L1
START-UP REPORT FORM
Amperage load connecti on, pu mp on
L1
L2
L3
FINAL CHECK
Is pump secured properly?
Yes No
Was pump checked for leaks?
Yes No
L1-L2 L2-L3 L3-L1
Do check valves operate properly? Yes No
Flow: Do pumps appear to operate at proper rate? Yes No
Noise level: Acceptable Unacceptable
Comments:
Installed by:
Company:
Person:
Date:
NOTES:
123 Spencer Plain Road • PO Box 1138 • Old Saybrook, CT 06475, USA
• Phone: (860) 399-5937 • Fax: (860) 399-7784
Email: sales@bjmpumps.com • Web Site: www.b jmpumps.com