WBC Wideband Coupler
Bird® Electronic Corporation now oers a convenient, cost eective product for RF Power Measurement in
High Power applications. The Bird BroadBand Directional Coupler uses the Bird Model 5000-XT, a
handheld meter, with a Wideband Coupler and the Bird Terminating Power Sensor for accurate,
repeatable readings of both UHF and VHF, forward and reflected power in broadcast facilities.
PROBLEMS } SOLUTIONS
Tight budgets for power measurement
} Cost eective coupler solution
Need to support multiple transmitter stations
} Portable equipment
Limited training for station personnel
Easy-to-use
}
Once the line section is installed, power meaurement is as simple as 1, 2, 3!
1. Connect the Terminating Power Sensor to the forward or
reected socket coupler.
2. Enter the oset value using the Model 5000 keypad.
3. Read the RF power output of your transmitter in Watts, kW, or dBm.
The BroadBand Directional Coupler is a cost eective Power Measurement alternative for your transmitter monitoring needs.

WBC Wideband Coupler
Specication Characteristic
Frequency Range 45 MHz to 230 MHz (VHF Model)
450 MHz to 890 MHz (UHF Model)
450 MHz to 800 MHz for 6” (UHF Models)
Maximum Power Transmission line and frequency
dependent (See Graph 1)
Nominal Coupling Transmission line dependent (See Table 1)
Directivity 28 db Min.
Coupler Output
Type “N” Female
Connector
Coupler Output VSWR 1.2 Max
Main Line VSWR 1.1 Max
Coupling Uncertainty
+/- 0.05 dB
(after correction)
Operating Temperature +10° to +40°C
Storage Temperature -20° to + 85°C
Weight Transmission line dependent (See Table 2)
Dimensions Transmission line dependent (See Table 2)
TRANSMISSION LINE POWER RATING
4000
1000
100
10
8 3/16
75
9 3/16
50
6 1/8
50
8 1/8
1 5/8
AVERAGE POWER KW
9 3/16
75
4 1/16
3 1/8
VHF UHF
1-5/8” 62 dB ± 2 db 59 db ± 2 db
3-1/8” 69 db ± 2 db 64 db ± 2 db
4-1/16” 70 db ± 2 db 67 db ± 2 db
6-1/8” 75 db ± 2 db 72 db ± 2 db
Table 1
Model
Number
Line Size Frequency
Range
Length
(in.)
Weigth
(lbs.)
WBC1-45 1-5/8 Flanged VHF 6.75 3.65
WBC1U-45 1-5/8 Unlanged VHF 6.38 1.8
WBC1-400 1-5/8 Flanged UHF 6.75 3.65
WBC1U-400 1-5/8 Unlanged UHF 6.38 1.8
WBC3-45 3-1/8 Flanged VHF 7.03 6
WBC3U-45 3-1/8 Unanged
VHF 6.5 2.75
(Recessed)
WBC3UF-45 3-1/8 Unanged
VHF 6.5 2.75
(Flush)
WBC3-400 3-1/8 Flanged UHF 7.03 6
WBC3U-400 3-1/8 Unanged
UHF 6.5 2.75
(Recessed)
WBC3UF-400 3-1/8 Unanged
UHF 6.5 2.75
(Flush)
WBC4-45 4-1/16 Flanged VHF 8.38 8.88
WBC4M-45 4-1/16 Flanged
VHF 8.38 8.88
(MYAT)
WBC4U-45 4-1/16 Unanged VHF 7.5 2.88
WBC4-400 4-1/16 Flanged UHF 8.38 8.88
WBC4U-400 4-1/16 Unanged UHF 7.5 2.88
WBC4M-400 4-1/16 Flanged UHF 8.38 8.88
WBC6-45 6-1/8 Flanged VHF 10.22 13.2
WBC6U-45 6-1/8 Unanged VHF 9.63 7.2
WBC6-400 6-1/8 Flanged UHF 10.22 13.2
WBC6U-400 6-1/8 Unanged UHF 9.63 7.2
Table 2
1
.7
1 10 100 1000 4000
Graph 1
30303 Aurora Rd. Solon, OH 44139 866.695.4569 www.bird-technologies.com
Coupler_Wideband_WBC-06032013
7/8