TM
SignalHawk
SH-362S, SH-361S, SH-362, SH-36S
Spectrum Analyzer / VNA
The SignalHawk™ Series of Spectrum Analyzers and VNA is the most user-friendly and accurate hand-held
test solution available for installing, maintaining and troubleshooting all segments of RF communication
systems. Field engineers, technicians, wireless equipment manufacturers, service providers, contractors,
tower erectors and military eld personnel alike have come to trust the eciency and precision results of
SignalHawk.
PROBLEMS } SOLUTIONS
Low fault location resolution
}
2 dB directivity and -135 dBm noise oor allows 11,265
points, or 20x the distance window (1488’) at the same 1.6”
resolution.
Low frequency resolution
} More than 50% greater freq resolution (705 vs. 461 points)
than others.
Slow sweeps
} More than 2x faster sweep times than the competition
(705 pts in 1.1s vs. 517 pts in 1.8s).
Poor lighting or bright light
} Large 34 sq in high-resolution, full-color display for indoor
or outdoor viewing.
Cross platform compatibility
} Compatible with several sensors for additional apps at
nearly half the cost of alternatives.
Cable loss masking eect
}
Ability to add osets to minimize cable loss masking eect.
Laptop requirement
} Work orders can be viewed right on the instrument with a
.pdf/.doc viewer. Can upload custom userwritten WordPad
help le.
Lack of access to AC
} 40% longer battery life (5.5 hours per charge), with eld-re
placeable battery.
Lack of universal connectivity and data storage
}
USB drive stores up to 90,000 traces.
Varying eld tech skill levels
} Easy-to-use, intuitive menus with one-button setup and
on-board help ve ways to look at mismatch.
Physically demanding operations
} Rugged unit, drop tested per military and European
standards

TM
SignalHawk
SH-362S, SH-361S, SH-362, SH-36S
APPLICATIONS
Cellular, PCS, DCS, 2G, 3G, 4G, CDMA, cdmaOne, CDMA 2000,
1x, 1x EV-DO, GSM, GPRS, EDGE, UMTS, HSDPA, W-CDMA,
TDMA, AMPS as well as 802.11, Bluetooth, Broadcast,
Emergency, Fire, GPS, HDTV, IBOC, In-Building, Lab,
Microwave, NPSPAC, Paging, Police, Private, Project 25, Public
Safety, Tactical Military, Telematics, Tetra, Trunking, Utilities,
WiMAX, WLAN and WLL.
SPECTRUM ANALYZER SPECIFICATIONS
Frequency Range 100 kHz to 3.6 GHz
Frequency Resolution 1 Hz
Frequency Uncertainty ± 1 ppm
Reference Aging
Temperature Drift
Data Points 705 displayed
Spectral Purity –85 dBc @ 30 kHz
Sweep Time 2.2 s, full span; 1 ms, zero span
Resolution Bandwidth 100 Hz to 1 MHz RBW
Video Bandwidth 10 Hz to 300 kHz VBW
Amplitude Accuracy ± 1.0 dB typ, ± 1.5 dB max
Dynamic Range 66 dB, intermod-free
Noise Floor –135 dBm DANL
Attenuator 0, 10, 20, or 30 dB; internal
Pre-Amplier +24 dB gain, internal
Single-Button ACPR,
Measurements Demod, C/I
± 1 ppm / year
± 1 ppm / °C
Occ BW, Channel Power, Field
Strength, AM/FM
Power Meter Option: compatible with Models
5012D, 5010D, 5010T, 5011, 5011-EF, 5016D,
5017D, 5018D, and 5019D power sensors. These
external power sensors provide ± 5% (± 0.2 dB)
accuracy, with NIST Traceability.
SIGNALHAWKTMSPECIFICATIONS
Display
Battery 5.5 hour, eld replaceable
Drop Test 1 meter per EN 61010-1
Transit Drop Test 10 drops per MIL-PRF-28800F
Explosive Atmosphere Per MIL-PRF-28800F 4.5.6.3
CE Compliant Yes
RF Input, N(F) +20 dBm (100 mW) max
USB Connectivity PC; USB drive and accessories
Size and Weight 11.5” x 10.5” x 3.8”, 7.8 lbs
Saved Trace Storage 300 internal; 90,000 USB drive
Win CE Viewers Word, Excel, PPT, PDF, Image
Power Meter
8.4”, TFT, 800 x 600 pixel
5012, 5010B, 5010T, 5011, 5011-EF, 5016 and
5017 External Sensors, Optional
VNA SPECIFICATIONS
Frequency Range 1.6 MHz to 3.6 GHz
Frequency +/-2 ppm uncertainty, 40 kHz res
Data Points 705 default, 12 to 11265 selectable
Sweep Time 0.6 s with 705 data points
RF Output, N(F) -40 dBm to +10 dBm, 1 dB steps
Interference Immunity +13 dBm on frequency
Directivity -42 dB calibrated
1-Port VNA Measurements Match (VSWR & Return Loss dB) Distance-to-
Fault (DTF), Cable Loss
2-Port VNA Loss/Gain -90 to +50 dB, 12/24 V Int Bias-Tee
2-Port VNA Measurements Gain & Loss (Amplier Gain,
Insertion Loss, Antenna Isolation)