CHARACTERISTICS
Power Levels 1, 2.5, 5, 10 kW
Meter 4421
Sensor Options 4020 Series or 4027A Series (See Below)
Load Options 8251, 8890-300, 8921, 8931-115, 8931-230
(See Below)
Impedance 50 Ohm
Frequency Range 4020
Sensor
100 KHz - 1000 MHz
Frequency Range 4027A
Sensor
250 KHz - 65 MHz
Accuracy 4020 Series ±3% across power and frequency range
Accuracy 4027A Series ±1% at calibration frequency and power
levels
±2% over remainder of power range, and
at other than calibration frequencies
Casters 4 locking swivel
Connector Type *Customer Specied
Operating Position Vertical only
Power Requirements 115/230 VAC, ±10%, 50/60 Hz
Ambient Temp Range 0° to 45°C (For 10kW 0°C to +40°C)
Storage Temperature -20°C to +70°C
Humidity 85% Max., Non condensing
Altitude Load derated above 5,000 feet
5kW & 10kW
Size/Weight
52” L x 20” W x 42” H / 250 lbs.
Fully assembled
1kW & 2.5kW
Size/Weight
42” L x 20” W x 42” H / 175 lbs.
Fully assembled
Material of Construction Stainless steel cart
Applicable Standards CE
CalibrationCart_SCC7-09062012
30303 Aurora Rd. Solon, OH 44139 866.695.4569 www.bird-technologies.com
Calibration Carts
SCC7 Series
4027A Series Power Sensor
Model Frequency Range Power Input
4027A250k 250-400 kHz 3 W to 10 kW
4027A400k 400-550 kHz 3 W to 10 kW
4027A800k 800-950 kHz 3 W to 10 kW
4027A2M 1.5-2.5 MHz 3 W to 10 kW
4027A4M 3-5 MHz 3 W to 10 kW
4027A10M 10-15 MHz 3 W to 10 kW
4027A12M 10-15 MHz 300 mW to 1 kW
4027A25M 25-30 MHz 3 W to 9 kW
4027A35M 35-45 MHz 3 W to 7.5 kW
4027A60M 45-65 MHz 3 W to 6 kW
4027A100M 95-105 MHz 3 W to 4 kW
4027A150M 150-170 MHz 3.75 W to 3.75 kW
4020 SERIES POWER SENSOR
Model Frequency Range Power Input
4021 1.8-32 MHz 300 mW to 1 kW at 1.2 kW max
4022 25-1000 MHz 300 mW to 1 kW at 1.2 kW max
4024 1.5-32 MHz 3 W to 10 kW at 1.2 kW max
4025 100-2500 kHz 3 W to 10 kW at 1.2 kW max
* For connector options, please refer to our catalog or contact sales at
866.695.4569 or sales@bird-technologies.com
ULTRA-STABLE SC13 LOADS
Model Frequency Range & VSWR Power Input
8865SC13 DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)
1kW
8890-300SC13 DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)
2.5 kW
8921SC13 DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)
5 kW
8931-115SC13 DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)
10 kW
8931-230SC13 DC to 28 MHz at 1.1 max.
(VSWR less than 1.05:1)
10 kW
HIGH POWER LOADS
Model Frequency Range & VSWR Power Input
8251 DC to 1 GHz at 1.1 max. 1000 W continuous
8890-300 DC to 1 GHz at 1.1 max.
1 GHz to 2 GHz at 1.25 max.
2 GHz to 2.4 Ghz at 1.3 max.
2500 W continuous
8921 DC to 1 Ghz at 1.1 max. 5000 W continuous
8931-115 DC to 400 MHz at 1.15 max.
400 MHz to 1 GHz at 1.20 max.
10 kW continuous w/
blower on
2.5 kW continuous w/
blower o
8931-230 DC to 400 MHz at 1.15 max.
400 MHz to 1 Ghz at 1.20 max.
10 kW continuous w/
blower on
2.5 kW continuous w/
blower o