VANESSA CM
Ceiling Mounting
Stand-Alone
INSTRUCTION SHEET
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
X
1/2 X
C
L
NOMINAL FIXTURE LENGTH X
2’ 16”
3’ 24”
4’ 32”
C
L
DRILL HOLE IN CEILING
*SEE NOTE (2)
E
STND - Standard Feed
Mounting
1. Install ceiling brackets (A) as
shown using 1/4” bolts (by others)
suitable for intended surface.
2. Drill hole in ceiling as shown
for ex conduit. Note: size of
hole depends on size of conduit
connector and must be large
enough to allow conduit connector
to protrude into ceiling.
3. Loosen captive screws (B) and
remove end plates (C) from both
ends.
1.25”
FIXTURE
1.5”
AA
4. Remove reector/liner.
4”
HEIGHT
5. Connect 1/2” ex conduit to
xture. Note: for wet locations ex
conduit must be liquid tight and
pipe thread sealant or teon tape
must be used on threads.
6. Mount xture on ceiling brackets
(A) and install supplied screws (D).
7. Make wire connections inside
xture.
WET LOCATION CONDUIT
(BY OTHERS)
1/2” TRADE SIZE WET
LOCATION CONNECTOR
(BY OTHERS)
D
B
C
Note: To be installed by a qualied electrician per N.E.C. and all local codes.
Birchwood Lighting • 3340 E. La Palma Avenue • Anaheim, CA 92806 • 714.550.7118 fax 714.550.7151
104
8. Reinstall reector/liner
9. Reinstall lens. Note: rmly press
along entire length of lens to ensure
a good seal.
10. Reinstall both end plates (C).
D
11. Seal hole around conduit
connector with silicone, caulking or
wall patch.
note: To remove lens, lift from end
using a at blade screw driver(E)
to pry loose. Note: take care not to
damage lens or gasket.
Continuous run, provide for 1/8”
between xtures.
820-00032
V-0520
VANESSA CM
Ceiling Mounting
Stand-Alone
INSTRUCTION SHEET
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
X
C
L
C
L
NOMINAL FIXTURE LENGTH X
2’ 16”
3’ 24”
4’ 32”
WET LOCATION CONDUIT (BY OTHERS)
1/2” TRADE SIZE WET LOCATION CONNECTOR
(BY OTHERS)
End Feeds - EFR | EFL | EF2
Mounting
1. Install ceiling brackets (A) as
shown using 1/4” bolts (by others)
suitable for intended surface.
2. Loosen captive screws (B) and
remove endplates (C) from both
ends.
4. Remove reector/liner.
5. Mount xture on ceiling brackets
(A) and install supplied screws (D).
1.25”
4”
FIXTURE
1.5”
HEIGHT
AA
E
6. Connect 1/2” ex conduit to
xture. *Note: for wet locations ex
conduit must be liquid tight and
pipe thread sealant or teon tape
must be used on threads.
7. Make wire connections inside
xture.
8. Reinstall reector/ liner
9. Reinstall lens. Note: rmly press
along entire length of lens to ensure
a good seal.
10. Reinstall both endplates (C).
B
D
C
FEED TYPES
EFR - END FEED RIGHT EF2 - END FEED BOTH ENDS
EFL - END FEED LEFT
Note: To be installed by a qualied electrician per N.E.C. and all local codes.
Birchwood Lighting • 3340 E. La Palma Avenue • Anaheim, CA 92806
714.550.7118 fax 714.550.7151
105
note: To remove lens, lift from end
using a at blade screw driver(E)
to pry loose. Note: take care not to
D
damage lens or gasket.
Continuous run, provide for 1/8”
between xtures.
820-00030
Due to a program of continuous improvement instructions
© 2018 Birchwood Lighting, Inc. All rights reserved.
are subject to change without notice.