Bircher Reglomat RAD00, RAD01 User Manual

1
Wall mounting Ceiling mounting
2
When not mounted When already mounted
3
5
4
* The device must only be operated at a protective low voltage with safe electrical insulation. Product repairs must be performed solely by the manufacturer.
* Shut off all power going to the sensor before attempting any wiring procedures.
* Maintain a clean & safe environment when working in public areas.
* Constantly be aware of pedestrian traffic around the door area.
* Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
* Always check placement of all wiring and components before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
* Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
Safety instructions
Microwave motion detector for automatic pedestrian doors [ES with direction recognition] Questions? Call us at 800 - 252-1272, 8am - 5pm central standard time.
DO NOT LEAVE ANY PROBLEMS UNRESOLVED - NEVER SACRIFICE SAFETY FOR ANY REASON
Impulse
Open sensor with a screwdriver
Drill holes using template
Install sensor with provided screws
Connections
Testing of the settings
1
motion
sensing the future
Side cable exit as shown on the left or front cable exit as shown below
1) Remove provided screws for installation.
white
1
brown
2
green
3
yellow
4
grey
5
- ~12-36 V DC
+ ~12-28 V AC
Common
Normally open
2)
1. Turn on power and allow detector to self-tune
2. Stay outside the detection zone for 5 seconds
Test the size and position of the sensing eld
7
10
9
Value for mounting height of 7' 3" (2.2 m) . Maximum mounting height: 13' 1" (4 m).
Avoid rain exposure
Avoid moving objects in sensing field
Avoid vibrations
Avoid proximity to fluorescent lights
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Bircher Reglomat at 800 - 252-1272 from 8am - 5pm central standard time. You may also visit our website at www.bircherreglomat.com
DO NOT LEAVE ANY PROBLEMS UNRESOLVED NEVER SACRIFICE SAFETY FOR ANY REASON
Technical data
2
Contact
Bircher Reglomat reserves the right to change any information on this document without notice.
For the latest version, please log on to www.bircherreglomat.com or call us at 847-952-3730 to request a copy of the current version.
Disclaimer
K6202.029 08/06 Bircher Reglomat reserves the right to change any information on this document without notice.
Power supply Current consumption Temp. range Humidity Microwave module Transmitting power Relay output pot. free Switching voltage Switching current Switching power Protection class Housing material
6
8
11
12
13
Interference avoidance
Setting all other parameters
Setting frontal inclination
Setting sensing field shape and size
Setting field shape and position
12-28 V AC / 12-36 V DC approx. 100 mA at 24 V AC,
+20° C
-4 °F to +140 °F [
-20° C to +60° C] 0 to 90%, non condensing K-band 24,125 GHz +/ 100 MHz
20 dBm change-over contact 48 V AC/DC
0.5 A AC/1 A DC 55 VA / 24 W suitable for the application after IP 54 ABS
Open position / narrow eld
Fig. 6.1 Fig. 6.2 Fig. 6.3
Adjustable antenna Open position (see g. 6.1)
Sensitivity potentiometer
Minimum
eld dimensions
3’ 3" x 1' 8" (1.0 x 0.5 m)
Maximum eld dimensions 8' 2" x 8' 2" (2.5 x 2.5 m)
Closed position / wide eld
Adjustable antenna Closed position (see g.6.2)
Sensitivity potentiometer
Minimum 4' 11" x 3' 3" (1.5 x 1.0 m)
Maximum eld dimensions 11' 6" x 6' 7" ( 3.5 x 2.0 m)
Side position / side eld
eld dimensions
1
2
6
5
min.
Sensitivity
4
min.
max.
0.5s
Output hold time
3
On
Off
Function switch
1 LED (function indication) 2 Cable connector 3 Sensitivity potentiometer 4 Adjustable horn antenna
Motion detection (Adjustment of relay hold time potentiometer):
Set potentiometer between 7-8 o'clock to get
a xed hold time of 0.5 s and a velocity of 2” (5 cm) / s
Set potentiometer between 9-5 o'clock to get
a hold time of 0.5 s @ 9 o’clock to 4 s @ 5 o’clock, with a velocity of 4” (10 cm) / s
Function switch
OFF*
Digital lter o, normal setting, maximum sensitivity.
Digital lter on, when
ON
4s
ltering of vibration and/or reective surfaces is necessary. Detection will be less sensitive, requiring more motion to activate the Impulse
* factory setting
7
max.
5 Internal side panels (aps) 6 Function switch 7 Output hold time potentiometer
Min.
Min.
Max.
Max.
Top
view
+1 Step
min.
15˚
Factory setting
0 point
15˚ 20˚
30˚
45˚
max.
45˚
3 Steps
4 Steps
9 Steps
FCC APPROVAL
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions: *this device may not cause harmful interference, and *this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a paticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: *Reorient or relocate the receiving antenna *Increase the separation between the equipment and receiver *Connect the equipment into an outlet on a circuit different from that to which the receiver is connected *Consult the dealer or an experienced radion/TV technician for help
Warning: Changes or modifications to this equipment not expressly approved by Bircher Reglomat AG may void the FCC authorization to operate this equipment.
3
Loading...