BIOTRONIK CardioMessenger Preliminary Manual

Preliminary
Manual
for
CardioMessenger
FCC ID: QRICM02-1 BIOTRONIK GmbH & Co.
Contents
What is Home Monitoring? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
About This Technical Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
User group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Conventions used in this technical manual . . . 4
The CardioMessenger Set and Its Components . . . . . . . . . . . . . . . 5
Safety Precautions – What Should I Watch Out For? . . . . . . . . . . . 6
Electronic Article Surveillance (EAS) Systems . 8
How Do I Use the CardioMessenger? . . . . . . . . . . . . . . . . . . . . . . . . 9
What must be done before using the Cardio-
Messenger? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Where should I put the CardioMessenger? . . . 9
How do I plug in the CardioMessenger? . . . . . 10
The CardioMessenger "traffic light" system .10
Turning on the CardioMessenger . . . . . . . . . . 11
Turning off the CardioMessenger . . . . . . . . . .12
Charging the CardioMessenger . . . . . . . . . . . . 12
How do I know when the batteries are running
low? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
How do I know that the CardioMessenger is
receiving and transmitting implant data? . . . . 13
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .13
Resetting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
When Does My Implant Transmit Data? . . . . . . . . . . . . . . . . . . . . . 16
How Do I Take Care of the CardioMessenger? . . . . . . . . . . . . . . . 17
343 851/A
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Technical Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . 21
Cardio Report . . . . . . . . . . . . . . . . . . . . . . . . . . 21
GSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Home Monitoring . . . . . . . . . . . . . . . . . . . . . . .21
BIOTRONIK Service Center . . . . . . . . . . . . . . . 21
SMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
US Regulatory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
FCC RF Exposure Requirements . . . . . . . . . . . 23
Legal Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Electromagnetic compatibility . . . . . . . . . . . . . 25
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
General information . . . . . . . . . . . . . . . . . . . . . 26
Permissible environmental conditions . . . . . .26
CardioMessenger remote unit . . . . . . . . . . . . . 26
CardioMessenger charging station . . . . . . . . .27
Rechargeable battery (integrated) . . . . . . . . . .27
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
What is Home Monitoring?
What is Home Monitoring?
Dear Patient. You have received a BIOTRONIK pacemaker or
implantable cardioverter-defibrillator (ICD) with a Home Monitoring function. The Home Monitoring fea­ture provides your attending physician with messages recorded by your implant at regular intervals, giving him or her information about your heart’s status.
Your implant has a small wireless transmitter. Your patient device, which we will call the Cardio­Messenger, receives the implant messages and transmits them to the BIOTRONIK Service Center. The data are processed there and can be viewed only by your physician via fax and on the Internet (when avail­able) in the form of a comprehensive report called a Cardio report.
Your doct or can use these data to deci de wh ether your implant settings need to be updated or if your therapy plan needs to be changed. If necessary, your physician will contact you about making an appointment for a follow-up examination.
For Home Monitoring to work, your implant must have the Home Monitoring function, and there must be cel­lular service in your area (GSM network).
The power of the transmission in your implant is low so as not to impair your health in any way. Since the transmission range is so short (less than 2 meters, or 6 feet), you need to use the CardioMessenger to send the information to the BIOTRONIK Service Center.
Note:
If the CardioMessenger is not operational or is located too far from the implant to receive information (more than 6 feet), your implant still functions normally. Only the Home Monitoring function is inactive. Although the data recorded by the implant cannot be transmit­ted, they are saved so that your physici an can evaluate them during your regularly scheduled follow-up examina tion. If you have an y quest ions, please cont act your physician.
About This Technical Manual
About This Technical Manual
User group
The CardioMessenger is to be used by patients with a BIOTRONIK pacemaker or an implantable cardio­verter-defibrillator (ICD) with the Home Monitoring function.
Conventions used in this technical manual
Note:
Provides additional information on the features of the CardioMessenger and how to operate it.
Caution!
If these instructions are not observed, minor injury or equipment damage may occur.
WARNING!
If these instructions are not observed, death, serious physical injury, or major equipment damage may result.
The CardioMessenger Set and Its Components
The CardioMessenger Set and Its Components
The BIOTRONIK CardioMessenger will not restrict your routine activities. The set comes equipped with the following components:
— The CardioMessenger with rechargeable batteries — A charging station with a power supply unit and
cable Accessories: — Belt clip
1)
—Carrying strap
2)
— Belt carrying case
3)
The CardioMessenger works like a cell phone and transmits the information received from the implant as a short message (SMS) via a mobile telephone net­work to the BIOTRONIK Service Center. The built-in, rechargeable batteries provide at least 24 hours of wireless operation (away from the charging station). Naturally, the CardioMessenger can also be used when placed in the charging station.
1) Catalog number 343 265
2) Catalog number 343 227
3) Catalog number 343 228
Safety Precautions – What Should I Watch Out For?
Safety Precautions – What Should I Watch Out For?
The CardioMessenger and its components are medi­cal devices and therefore comply with strict standards for their development, manufacture, and testing.
Please observe the following safety instructions:
WARNING!
Turn off the CardioMessenger in locations where cell phones are
prohibited
, such as hospitals or airplanes. Such areas can be identified by the following or simi­lar signs:
WARNING!
Maintain a minimum distance between the patient device and your implant.
Like a cellular phone, the CardioMessenger device can temporarily interfere with your implant if it is too close to it. To avoid interference, maintain a minimum distance of 20 centimeters (7 inches) between the CardioMessenger and implant.
Never place the CardioMessenger on your chest directly over the implant.
Do not carry the CardioMessenger inside the breast pocket of your shirt or jacket, and not directly on your skin.
Caution!
Protect the CardioMessenger and charging station from:
— Water and high humidity (e.g., in the bathroom) — Temperatures above 40°C (104°F) — Temperatures below 10°C (50°F) for the charging
station
Safety Precautions – What Should I Watch Out For?
— Temperatures below -5°C (23°F) for the Cardio-
Messenger
— Barometric pressure below 700 and above
1060 hPa
— Violent shocks or other strong mechanical influ-
ences
— Strong sources of light (direct sunlight, strong
halogen lamps) — Solvents, acids, detergents, and lyes — Handle the antenna with care.
Caution!
Never use the CardioMessenger if it has been dam­aged; return it to your physician.
Before use, make sure that none of the components are visibly damaged.
Only use the following original BIOTRONIK devices: — The CardioMessenger
— The charging station with the appropriate power
supply unit, type FW 7555 M/06 Other accessories can increase the interference emit-
ted and the device’s susceptibility to interference.
Caution!
The CardioMessenger may only be opened and repaired by authorized trained personnel, and the rechargeable batteries (type LP 103463) may only be exchanged by professionals.
Note:
Do not throw away the CardioMessenger with house­hold trash. Dispose of it according to legal guidelines, like you would for other electronic components, such as computers.
In particular, rechargeable lithium ion batteries should be disposed of by the manufacturer according to legal guidelines.
Caution!
The covered data ports are not intended for the user. Do not remove the cover.
Safety Precautions – What Should I Watch Out For?
Electronic Article Surveillance (EAS) Systems
Equipment such as retail theft prevention systems may interact with the implanted device. Patients should be advised to walk directly through and not to remain near an EAS system longer than necessary.
How Do I Use the CardioMessenger?
How Do I Use the Cardio­Messenger?
The following section describes how to operate and use the CardioMessenger.
What must be done before using the CardioMessenger?
Find a suitable place to put the CardioMessenger and charging station.
The distance between your implant and the Cardio­Messenger should not be too close in order to prevent interference with implant operation. On the other hand, the distance should not be beyond the implant transmitter’s range.
Note:
Home Monitoring can only work when the distance between the implant and CardioMessenger is not less than 20 centimeters (7 inches) and not more than 2 meters (6 feet).
• Place the device on a solid base so that it cannot
fall.
• Keep the CardioMessenger from being exposed to
moisture; bathrooms, for example, are unsuitable
locations for the CardioMessenger.
• Do not expose the device to heat; direct sunlight is
also not recommended.
• Do not place the device next to a television, micro-
wave oven, or a similar source of interference.
Where should I put the CardioMessenger?
A nightstand would be a good place for the Cardio­Messenger since the distance between you and the CardioMessenger would probably not be more than 2 meters (6 feet). In addition, your attending physician will probably select nighttime as the regular trans­mission time.