Bioscrypt 4GFLEXP, 4GSTNP, 4GSTNH, 4GFLEXG, 4GSTNG User Manual

...
Installation Guide
Bioscrypt® V-Station™ 4G
Bioscrypt
®
V-Flex™ 4G
Document Version 1.0
Copyright Information
COPYRIGHT INFORMATION
© 2009, L-1 Identity Solutions, Inc. All rights reserved. This product and related documentation are protected by copyright and di stributed
under licenses restricting their use, copying, distribution, and de-com pilation. No part of this produ ct or related documentation may be reproduced in any form by any means without written permission from L-1 Identity Solutions and its licensors, if any.
Redistributions of source code must retain the above copyright notice, this list of conditions and the fol­lowing disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the BioAPI® Consortium nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
TRADEMARKS The trademarks identified herein are the trademarks or registered trademarks of L-1 Identity Solutions,
Inc. All other brands and products referenced herein are acknowledged to be trademarks or registered trademarks of their respective holders or manufacturers.
THE PRODUCT AND PUBLICATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.
THIS PUBLICATION COULD INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ER­RORS. CHANGES ARE PERIODICALLY ADDED TO THE INFORMATION HEREIN; THESE CHANGES WILL BE INCORPORATED IN NEW EDITIONS OF THE PUBLICATION. L-1 IDENTITY SO­LUTIONS, INC MAY MAKE IMPROVEMENTS AND/OR CHANGES IN THE PRODUCT(S) AND/OR THE PROGRAM(S) DESCRIBED IN THIS PUBLICATION AT ANY TIME.
IMPORTANT—Please refer to the L-1 Identity Solutions End User License Agreement document and read it carefully before using any L-1 Identity Solutions software on your computer. This document con­tains important information about your legal rights.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
ii
Notices
The Veri-Series 4G line of products have been tested for compliance with all applicable international standards. The resulting approvals are listed below, and are additionally printed on the labelling located on the rear panel of the product. V- Flex 4G FCC, CE V- Station 4G FCC, CE
FCC Information to Users
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003.
Applicable only to V-Station 4G series product: This product complies with FCC radiation exposure limits set forth for an uncontrolled environment. To comply with FCC RF exposure requirements, it must be installed and operated in accordance with provided instructions. The unit requires minimum 20cm (8inch) spacing between the unit and all person’s body (excluding hands and feet) during wireless modes of operation.
CE Information to Users
Notices
All Veri-Series 4G devices have the CE mark, for compliance with CISPR22/EN55022 requirements. For European Union (EU) countries, V-Flex 4G and V- Station 4G are compliant with CE under the R&TTE Directive, related to the radio transceivers that are part of their design.
Warning to Users
Caution: Changes or modifications not expressly approved by Bioscrypt Inc. could void the user’s
authority to operate the equipment.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc. A-1
Table of Contents
Table of Contents
1. Introduction ........................................................................................................................................ 1-2
1.1. Symbols Used in this Guide ............................................................................................... 1-2
1.2. Product Overview ............................................................................................................... 1-3
1.2.1. V-Station 4G ...................................................................................................... 1-3
1.2.2. V-Flex 4G ........................................................................................................... 1-4
1.3. Sensors .............................................................................................................................. 1-5
1.3.1. UPEK TCS1 ....................................................................................................... 1-5
1.3.2. UPEK TCS2 ....................................................................................................... 1-5
1.3.3. Secugen Optical ................................................................................................. 1-5
1.4. Device Dimensions ............................................................................................................ 1-6
1.4.1. V-Station 4G ...................................................................................................... 1-6
1.4.2. V-Flex 4G ........................................................................................................... 1-7
1.5. Safety Precautions ............................................................................................................. 1-8
1.5.1. Grounding .......................................................................................................... 1-8
1.5.2. Electro-Static Discharge .................................................................................... 1-8
1.5.3. Device Handling Guidelines ............................................................................... 1-8
2. Planning the Installation ..................................................................................................................... 2-2
2.1. Recommended Steps for a Successful Installation ........................................................... 2-3
2.2. Requirements ..................................................................................................................... 2-4
2.2.1. Hardware Requirements .................................................................................... 2-4
2.2.2. Computer Requirements .................................................................................... 2-4
2.2.2.1. SecureAdmin Server Requirements .................................................... 2-4
2.2.2.2. SecureAdmin Client Requirements ..................................................... 2-4
2.2.2.3. Microsoft .Net 3.5 Requirements ......................................................... 2-4
2.2.2.4. Supported Operating Systems ............................................................ 2-5
2.2.2.5. SQL Server 2005 Express Edition........................................................ 2-5
2.2.2.6. Oracle 10G Express ............................................................................ 2-5
2.2.3. Network Requirements ...................................................................................... 2-5
2.2.4. Software Requirements ..................................................................................... 2-5
2.3. Unpack Equipment ............................................................................................................. 2-6
2.3.1. Parts List ............................................................................................................ 2-6
2.4. Choosing the Install Location ............................................................................................
2.5. Plan Device Network .......................................................................................................... 2-8
2.6. Choose Network Type ....................................................................................................... 2-9
2.6.1. RS-232 ............................................................................................................... 2-9
2.6.2. RS-485 ............................................................................................................... 2-9
. 2-7
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
iii
Table of Contents
2.6.2.1. RS-485 Cable Specification ............................................................. 2-10
2.6.2.2. RS-485 Cable Lengths ..................................................................... 2-10
2.6.2.3. RS-485 Network Topology ............................................................... 2-10
2.6.3. Ethernet ........................................................................................................... 2-11
2.6.4. Wireless Network Design Considerations ....................................................... 2-11
2.7. Choose Power Source .................................................................................................... 2-12
3. Install Software ................................................................................................................................... 3-2
3.1. SecureAdmin Server .......................................................................................................... 3-2
3.1.1. Repairing an Installation of SecureAdmin Server .............................................. 3-7
3.1.2. Uninstalling SecureAdmin Server ...................................................................... 3-7
3.1.3. Upgrading an Installation of SecureAdmin Server ............................................. 3-7
3.2. SecureAdmin Client ........................................................................................................... 3-8
3.2.1. Modifying an Installation of SecureAdmin Client ............................................ 3-12
3.2.2. Repairing an Installation of SecureAdmin Client ............................................ 3-12
3.2.3. Uninstalling SecureAdmin Client .................................................................... 3-12
3.2.4. Upgrading an Installation of SecureAdmin Client ........................................... 3-13
4. Install Hardware ................................................................................................................................. 4-2
4.1. Wall Mounting Schemes .................................................................................................... 4-2
4.2. Installing a Mounting Plate ................................................................................................. 4-2
4.3. Installation Hardware ......................................................................................................... 4-5
4.4. Attach Device to Mounting Plate ........................................................................................ 4-5
4.5. Connect Device to Earth Ground ....................................................................................... 4-6
4.6. Connect Device to Power Source ...................................................................................... 4-7
4.7. Connect Device to Network ............................................................................................... 4-9
4.7.1. Ethernet Network Connections .......................................................................... 4-9
4.7.2. RS-232/RS-485 Network Connections .............................................................. 4-9
4.7.3. Wireless Network Connections ....................................................................... 4-11
4.8. Connect Device to Door .................................................................................................. 4-12
4.9. Aux Port .......................................................................................................................... 4-14
4.10. Install Ferrite Core ........................................................................................................ 4-15
5. System Start-up Procedures .............................................................................................................. 5-2
5.1. System Start-up Overview .................................................................................................
5-2
5.2. Device Configuration Check .............................................................................................. 5-2
5.3. RS-232 to RS-485 Converter Ground Fault Check ........................................................... 5-3
5.4. Device Ground Fault Check................................................................................................ 5-3
6. Configure Device................................................................................................................................. 6-2
6.1. Register Device................................................................................................................... 6-2
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
iv
Table of Contents
7. Maintenance and Cleaning................................................................................................................. 7-2
7.1. Field Maintenance............................................................................................................... 7-2
7.1.1. Disarming the Tamper Protection ...................................................................... 7-2
7.1.2. Replacing the Sensor ......................................................................................... 7-3
7.1.2.1. V-Flex 4G ............................................................................................ 7-3
7.1.2.2. V-Station 4G ........................................................................................ 7-5
7.1.3. Calibrating the Sensor ....................................................................................... 7-7
7.2. Cleaning ............................................................................................................................. 7-9
8. Troubleshooting .................................................................................................................................. 8-2
8.1. Installation Error Messages ................................................................................................ 8-2
8.1.1. Error 1303 - Insufficient Privileges ..................................................................... 8-2
8.1.2. Error 27552 - Error Creating Database .............................................................. 8-3
8.1.3. Invalid Password ................................................................................................ 8-4
8.1.4. Error 27502 - User Not Associated with Trusted SQL Server ........................... 8-5
8.1.5. Error 27502 - SQL Server Does Not Exist ......................................................... 8-6
8.1.6. Insufficient System Memory ............................................................................... 8-7
8.1.7. Out of Disk Space .............................................................................................. 8-8
9. Company Contacts.............................................................................................................................. 9-1
9.1. Registering your Product .................................................................................................... 9-1
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
v
This page left blank intentionally
Table of Contents
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
vi
List of Tables
List of Tables
Table 2-1: Communications Network Comparison ................................................................................ 2-9
Table 2-2: Category 5 Cable Characteristics ...................................................................................... 2-10
Table 2-3: V-Station 4G and V-Flex 4G Power Requirements ........................................................... 2-12
Table 4-1: PoE Pin Assignments ........................................................................................................... 4-9
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
ix
This page left blank intentionally
List of Tables
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
x
List of Acronyms
These acronyms and abbreviations are used in this document: A Ampere
ABS Acrylonitrile Butadiene Styrene AC Alternating Current AUX Auxiliary AWG American Wire Gauge CAT-5 Category 5 CD Compact Disc CISPR Comité Internationale Spécial des Perturbations Radioelectrotechnique COM Common DC Direct Current DPI Dots per Inch ESD Electro-Static Discharge FCC Federal Communications Commission FPF Finger Placement Feedback GB Gigabyte GND Ground Hz Hertz I/O Input/Output ID Inner Diameter kV Kilovolt LCD Liquid Crystal Display LED Light Emitting Diode MAC Media Access Control mA Milliamp MB Megabyte N.C. Normally Closed N.O. Normally Open NEG Negative OD Outer Diameter PC Personal Computer PDF Portable Document Format pF Picofarad POS Positive PoE Power Over Ethernet QVGA Quarter Video Graphics Array RAM Random Access Memory RoHS Restriction of Hazardous Substances TFT Thin Film Transistor UPS Uninterruptible Power Supply USB Universal Serial Bus VAC Volts Alternating Current VDC Volts Direct Current W Watt
List of Acronyms
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
xi
This page left blank intentionally
List of Acronyms
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
xii
Glossary
Glossary
Administrator - A user who is authorized to manage the settings and user information of a fingerprint reader. Administrators can enroll or delete users and change device settings.
Single Door Access Control - The capability of controlling/monitoring all functions related to a single entry/exit point.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
xiii
This page left blank intentionally
Glossary
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
xiv
Introduction
CHAPTER 1 - INTRODUCTION
Chapter Overview
This chapter provides an introduction to the V-Station 4G and V-Flex 4G devices, their specifications and features, and safety guidelines that should be observed when using or handling the devices.
Chapter Index
1. Introduction ........................................................................................................................................ 1-2
1.1. Symbols Used in this Guide ............................................................................................... 1-2
1.2. Product Overview ............................................................................................................... 1-3
1.2.1. V-Station 4G ...................................................................................................... 1-3
1.2.2. V-Flex 4G ........................................................................................................... 1-4
1.3. Sensors .............................................................................................................................. 1-5
1.3.1. UPEK TCS1 ....................................................................................................... 1-5
1.3.1. UPEK TCS2 ....................................................................................................... 1-5
1.3.1. Secugen Optical ................................................................................................. 1-5
1.4. Device Dimensions ............................................................................................................ 1-6
1.4.1. V-Station 4G ...................................................................................................... 1-6
1.4.2. V-Flex 4G ........................................................................................................... 1-7
1.5. Safety Precautions ............................................................................................................. 1-8
1.5.1. Grounding .......................................................................................................... 1-8
1.5.2. Electro-Static Discharge .................................................................................... 1-8
1.5.3. Device Handling Guidelines ............................................................................... 1-8
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-1
Introduction
1. INTRODUCTION
This manual provides step-by-step procedures for installing a Bioscrypt V-Station 4G or V-Flex 4G de­vice. It covers the entire process of physically installing the device, making the necessary power, ground, and network connections, and registering the device in SecureAdmin. Instructions for field re­pairs and cleaning are also provided.
1.1. SYMBOLS USED IN THIS GUIDE
The symbols shown below are used throughout this manual. They denote special issu es the user might encounter. Their definitions are given below.
DANGER
This symbol denotes a danger condition that may cause death or excessive damage to property.
WARNING
This symbol denotes a warning condition that may cause severe injury or major damage to property.
CAUTION
This symbol denotes a cautionary condition that may cause injury or minor damage to property.
NOTICE
This symbol denotes a situation needing additional advice to avoid incorrect usage.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-2
RODUCT OVERVIEW
1.2. P
Introduction
Finger Scan
Ridge-Lock™
Power Indicator
LED
Optional Internal Smart Card or Proximity Reader
1.2.1. V-S
Sensor
TATION 4G
Tricolor Pass/Fail Indicator LEDs
(Amber/Off/Green/Red)
2.5” backlit TFT LCD (QVGA, 16 million color)
Function Keys
Navigation Keypad
Housing
Illuminated Keypad
USB Port
Figure 1-1: V-Station 4G Device
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-3
Introduction
1.2.2. V-F
LEX 4G
Finger Scan
Ridge-Lock™
Tricolor Pass/Fail Indicator LEDs
(Amber/Off/Green/Red)
Sensor
Power Indicator LED
Optional Internal Smart Card or Proximity Reader
Housing
USB Port
Figure 1-2: V-Flex 4G Device
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-4
1.3. S
Introduction
ENSORS
The V-Station 4G and V-Flex 4G devices offer three types of sensor interfaces.
1.3.1. UPEK TCS1
Key Features:
Active Capacitive Fingerprint sensing
256 x 360 Sensor Array 508 DPI
+/- 15kV Air ESD Resistance
Figure 1-3: UPEK TCS1 Sensor
1.3.1. UPEK TCS2
Key Features:
Active Capacitive Fingerprint sensing
208 x 288 Sensor Array 508 DPI
+/- 15kV Air ESD Resistance
Figure 1-4: UPEK TCS2 Sensor
1.3.1. S
Figure 1-5: Secugen Optical Sensor
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
ECUGEN OPTICAL
Key Features:
Optical Fingerprint sensing
258 x 336 Sensor Array 500 DPI
+/- 15kV Air ESD Resistance
1-5
1.4. DEVICE DIMENSIONS
Introduction
1.4.1. V-S
TATION 4G
164.58
73.04
159.38
All dimensions in millimeters (mm).
Figure 1-6: V-Station 4G Dimensions
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-6
Introduction
1.4.2. V-F
LEX 4G
98.00
89.14
30.00
70.53
158.67
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
67.50
30.00
All dimensions in millimeters (mm).
Figure 1-7: V-Flex 4G Dimensions
1-7
Introduction
1.5. S
AFETY PRECAUTIONS
Below are safety precautions that should be observed when operating or installing a device.
1.5.1. G
ROUNDING
The device's ground connection must be properly connected to avoid damage by Electro-Static Discharge (ESD). The effects of ESD can degrade or destroy semiconductor junctions of an electronic device. Earth Ground (EGND) is a low­impedance path to earth for the purpose of discharging lightning, static, and radiated energy, and for maintaining the main service entrance at earth potential. Consult your local electrical codes for guidelines.
1.5.2. E
LECTRO-STATIC DISCHARGE
Bioscrypt recommends that Administrators inform Users of these points during the enrollment process:
Always use the Ridge-Lock to position a finger before touching the sensor.
Always stand on the ESD-dissipative floor covering (if installed).
Do not touch other people or objects when touching the sensor.
Always maintain at least 12 inches of space around yourself when touching the
sensor.
Do not allow articles of clothing to touch the sensor.
Bioscrypt recommends that Installers always follow these points (in addition to the points listed above):
When installing or working on a unit, always use a grounding wrist-strap that is connected to a quality Earth ground.
Check the device's cabling for ground faults.
Ensure that the device's ground connection (located on the rear of the device) is
connected to a quality Earth Ground.
1.5.3. D
Do not install the device in locations where the device would be exposed to direct sunlight, high levels of relative humidity, particulate matter, or flammable vapors.
Do not install the device near radiators or other heat sources. Do not allow magnetic objects to come within close proximity to the device. Strong
magnetic fields might damage the device. Do not let liquids contact the device. Do not attempt to alter the device for any reason. Modifications will void the product
guarantee. Do not attempt to disassemble the device in any way beyond what is necessary for
sensor field replacement. Do not use the device for any purpose other than for what it was designed.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
EVICE HANDLING GUIDELINES
1-8
Introduction
Do not plug any equipment into the USB port other than flash memory devices. Do not allow users to place or hang objects on the device, such as coffee cup s or
purses. Do clean the device regularly to remove dust, grime, and fingerprint residue. Do instruct users how to present a fingerprint correctly.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-9
This page left blank intentionally
Introduction
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
1-10
Planning the Installation
Chapter 2 - Planning the Installation
Chapter Overview
This chapter details how to plan a successful installation, recommended steps, and explains the hardware and software components of typical setup scenarios.
Chapter Index
2. Planning the Installation ..................................................................................................................... 2-2
2.1. Recommended Steps for a Successful Installation ........................................................... 2-3
2.2. Requirements ..................................................................................................................... 2-4
2.2.1. Hardware Requirements .................................................................................... 2-4
2.2.2. Computer Requirements .................................................................................... 2-4
2.2.2.1. SecureAdmin Server Requirements .................................................... 2-4
2.2.2.2. SecureAdmin Client Requirements ..................................................... 2-4
2.2.2.3. Microsoft .Net 3.5 Requirements ......................................................... 2-4
2.2.2.4. Supported Operating Systems ............................................................ 2-5
2.2.2.5. SQL Server 2005 Express Edition........................................................ 2-5
2.2.2.6. Oracle 10G Express ............................................................................ 2-5
2.2.3. Network Requirements ...................................................................................... 2-5
2.2.4. Software Requirements ..................................................................................... 2-5
2.3. Unpack Equipment ............................................................................................................. 2-6
2.3.1. Parts List ............................................................................................................ 2-6
2.4. Choosing the Install Location ............................................................................................. 2-7
2.5. Plan Device Network .......................................................................................................... 2-8
2.6. Choose Network Type ....................................................................................................... 2-9
2.6.1. RS-232 ............................................................................................................... 2-9
2.6.2. RS-485 ............................................................................................................... 2-9
2.6.2.1. RS-485 Cable Specification ............................................................. 2-10
2.6.2.2. RS-485 Cable Lengths ..................................................................... 2-10
2.6.2.3. RS-485 Network Topology ............................................................... 2-10
2.6.3. Ethernet ........................................................................................................... 2-11
2.6.4. Wireless Network Design Considerations ....................................................... 2-11
2.7. Choose Power Source .................................................................................................... 2-12
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-1
Planning the Installation
2. PLANNING THE INSTALLATION
Planning the installation is the single most important aspect of a successful installation. In general, you need to consider the access controller, the door locks, the devices, and the need for a network. By the time you are ready to install the system, all of the details presented in the list below should be known. Take a moment to go through them now before starting your installation.
During the planning phase, you should determine:
What type of authentication is required for your application?
How many doors need to be secured?
What type of device will be on each door? Doors already inside a secure area might not need the
same type or level of security.
If multiple V-Series 4G devices require networking for template distribution/management, then a dedicated PC is recommended to administer the system, as well as an RS-485 to RS-232
converter, and cabling for serial communications or cabling for Ethernet.
Verify that the chosen access controller supports the Wiegand formats supported by V-Station 4G devices.
Identify all wiring by the signal levels it is to carry. Use separate cables and conduits for
different signal groups to avoid cross talk. Plan to separate them by these groups: Power distribution: Wires carry power to devices, door strikes, etc.
Data communication: RS-485, RS-232, USB, Wiegand, Ethernet, etc. Signal: Door contact, request-to-exit push button, alarm input, etc.
When planning device placement, determine the distance limitation of each signal type and use repeaters if necessary.
Determine the availability of a quality earth ground
V-Series 4G devices are intended for indoor use only.
If you have any unresolved issues with the items on this list, contact L-1 EAS Technical Support for additional information before beginning any installation.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
WARNING
V-Station 4G and V-Flex 4G devices should be installed by only a qualified technician. If you are not qualified to perform an installation task, call L-1 EAS Technical Support or contact a qualified installer.
2-2
Planning the Installation
2.1. R
ECOMENDED STEPS FOR A SUCCESSFUL INSTALLATION
Every installation is unique. Sometimes the issues are well defined and can be handled in a standard fashion; sometimes the issues are very specific and may not be immediately recogniz­able.
L-1 EAS recommends following these steps for a successful installation: Plan the installation - Choose the type of hardware required, decide if a network is required, and
decide on the location and number of required devices. Unpack all items - Unpack all items and check against the packing list. Install network hardware components - Install the cabling and components needed to run the
system. Install software - Install the software needed to set up the devices. Preconfigure device - Connect the device to the USB cable, supply power to the device, and
preconfigure the device. Mount devices - Mount the devices in their final locations Power distribution and device hook up - Connect the device wiring via the back panel. Power-up procedure - Check the power conne ction s and start the system safely. Enroll users - Enroll users into the system (for user enrollment procedures). Chapters 3 through 7 in this document present more information on these steps.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-3
Planning the Installation
2.2. R
EQUIREMENTS
PC workstation with:
1 GHz Intel® Pentium® 4 processor or equivalent
1 GB RAM (2 GB recommended)
CD-ROM drive
One available COM port or USB port
Ethernet card
Display: 1024 x 768 high color (minimum)
Regulated DC Power supply
Door controller
TCP/IP network environment
RS-232 to RS-485 converter with power supply (for advanced administrative features).
2.2.1. H
ARDWARE REQUIREMENTS
Deadbolt/door strike
Snubber diode required to protect regulated DC power supply from inductive
kickback(1N4007 diode or equivalent recommended)
Separate power supply for the deadbolt/door strike based on supplier’s recommendations.
External relay (if required)
Earth ground
Networking cable
2.2.2. C
OMPUTER REQUIREMENTS
2.2.2.1. S
ECURE ADMIN SERVER REQUIREMENTS
Hard disk space: 10 MB
2.2.2.2. S
ECUREADMIN CLIENT REQUIREMENTS
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Hard disk space: 25 MB
2.2.2.3. M
ICROSOFT .NET FRAMEWORK 3.5 REQUIREMENTS
Hard disk space: Up to 500 MB might be required
2-4
Planning the Installation
2.2.2.4. S
UPPORTED OPERATING SYSTEMS
SecureAdmin Server and SecureAdmin Client support these operating systems:
Windows Server 2003 R2
Windows Server 2008
Windows Vista
Windows XP Service Pack 2 or higher
2.2.2.5. SQL S
ERVER 2005 EXPRESS EDITION
Hard disk space: 350 MB of available hard-disk space for the recommended installation. Approximately 425 MB of additional available hard-disk space for SQL Server Books Online, SQL Server Mobile Books Online, and sample databases.
2.2.2.6. O
RACLE 10G EXPRESS
Hard disk space: Server component: 1.6 GB Client component: 75 MB
2.2.3. N
ETWORK REQUIREMENTS
The V-Station 4G and V-Flex 4G devices function on 100 baseT networks.
2.2.4. S
OFTWARE REQUIREMENTS
Both SecureAdmin Server and SecureAdmin Client require these software applications as prerequisites: .net Framework 3.5 Windows Installer 3.1
If these applications are not already installed, they will get installed during the setup process.
SecureAdmin Server and SecureAdmin Client also require System Administrator access to install the application.
SecureAdmin uses a self-signed certificate (x.509 certificate) with a file extension of .pfx.
You have the option of installing your own certificate, which must be purchased from a recognized authority in advance. The SecureAdmin self-signed certificate is installed only with the SecureAdmin server component. No certificate is installed with the SecureAdmin client component, and during the client installation, you are asked to specify which type of certificate SecureAdmin server will be using (the self-signed certificate provided with the SecureAdmin server component installation or a signed certificate from another authority such as VeriSign.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-5
2.3. U
NPACK EQUIPMENT
Unpack all items and check against the packing list.
Planning the Installation
2.3.1. P
ARTS LIST
Quantity Component
Hardware
1 V-Station 4G or V-Flex 4G device 1 Wall mounting plate/mullion mounting plate 6 #6-32 3/4" Philips pan-head screw 6 #6 1" Philips pan-head self-tapping screws 6 #4-8 1" nylon wall anchors
29 Crimp connector, B Wire (RoHS)
2 6-32 security screw, pin-in hex, 3/8" 2 0.013" ID, 3/8" OD, 1/32" thick, fiber washers 1 Ethernet ferrite core
1 DC & I/O lines ferrite core 1 External power cable 1 External signal cable
1 Micro-USB device cable 1 Micro-USB PC cable
Tools
1 1/8" pin-in-hex security key 2.5"
Documentation
1 Installation Guide (on Installation CD) 1 Operator's Manual (on Installation CD) 1 Quick Start Guide (on Installation CD and printed copy in package)
Documentation for your new device is installed onto your computer when you install the SecureAdmin software. The product documentation is also available online at:
http://www.l1id.com/pages/450-product-manuals
The documentation is provided in Adobe Acrobat format (PDF). The Adobe Acrobat Reader application is available on the Installation CD or at:
http://www.adobe.com
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-6
Planning the Installation
2.4. C
HOOSING THE INSTALL LOCATION
V-Station 4G and V-Flex 4G devices are designed to mount on either a double-gang electrical box or on any flat surface. Consult with local professionals regarding any building and safety codes that might affect your installation. The correct mounting height is shown below in Figure 2-1.
Factors to consider when determining the position of a device on the wall:
Proximity to other switch plates or fixtures (the device should ideally be mounted in-line with other plates or fixtures)
Distance from the floor to the top of the device (L-1 EAS recommends using a height be­tween 48 and 54 inches).
The device should be mounted on the knob-side of the door
Compliance with the Americans with Disabilities Act if in the United States. Information
about this Act is available at http://www.usdoj.gov.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
48 – 54”
Figure 2-1: Correct Mounting Height
2-7
Planning the Installation
2.5. P
LAN DEVICE NETWORK
The V-Station 4G and V-Flex 4G devices feature a built-in single-door relay that allows them to control a single door lock. They can therefore function on their own or as part of a larger access control system.
System component selection is specific to each installation, but a minimum system would consist of a finger-scan device mounted on or near an access point, an electric lock, and ca­bling.
A more complex system might consist of devices at multiple access points (each with an electric door lock), a multi-point controller, networking, and a PC to run the access controller and Secu­reAdmin Server software.
See Figure 2-2 below for an example (non-Ethernet) system diagram.
Regulated DC Power
Supply
Door
Controller
+(Pos)
-(Neg)
2
Device Device Device Device
3
EGND EGND
Data0 Data1 Wiegand GND.
3 3
EGND
3
RS-232 / RS-485
Figure 2-2: Example RS-485 System Diagram
Installation of locks and access controllers should be compl eted according to their respective manufacturers' specifications and in accordance with all local codes. Final connections to the device are explained in more detail in Chapter 4.
To avoid externally generated transients, do not run any wires near utility AC power wiring, light­ning rod grounding wire, etc. Grounding equipment is required for ESD prote ction and safety.
3 3 3 3
EGND
Converter (optional)
Computer
RS-485 RS-485 Signal GND
Cat5 Twisted Pair
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-8
Planning the Installation
2.6. C
HOOSE NETWORK TYPE
If your installation requires the use of network communications, then the choice of cable, the cable run length, the network topology, and the termination of the network are important aspects that must be considered. The V-Station 4G and V-Flex 4G devices can be networked using RS-232, RS-485, or Ethernet protocols.
Table 2-1, below, outlines relevant parameters of the RS-485, RS-232, and 100 baseT Ethernet communication protocols.
Spec RS-485 RS-232 100BaseT Mode of Operation Differential DC Coupled Single-ended DC Coupled Multi
DC Isolation No No No Maximum Distance 4000 feet* 150 feet* 4000 feet
Number of Devices on one line
Maximum Data Rate
31 1 Unlimited 56 Kbps
(recommended)
56 Kbps* (recommended) Auto-negotiated
Table 2-1: Communications Network Comparison
2.6.1. RS-232
If your system has only one device, or a few devices (each only a short distance away from the SecureAdmin PC) then RS-232 can be used, provided that each device can have a dedicated RS-232 port.
With RS-232 at 9600 baud, a distance of 150 feet is possible with shielded cable, but at 56 Kbps, a maximum of only 20 feet is recommended.
2.6.2. RS-485
RS-485 has two distinct advantages over the more common RS-232. First, it allows you to connect up to 31 V-Station 4G devices to a PC with an external RS-232 to RS­485 converter (available from L-1 EAS). Second, the RS-485 specification allows for cable run lengths up to 4000 feet (1200 meters) at modest baud rates.
An RS-485 network is required instead of RS-232 if:
Multiple devices must be connected together so that templates can be distributed among the devices
The installation has only a single device, but it is over 150 feet (45 meters) from the host PC.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-9
Planning the Installation
2.6.2.1. RS-485 C
ABLE SPECIFICATION
V-Station 4G devices provide a 2-wire, half-duplex RS-485 interface. The main cable run should be low capacitance, twisted-pair cable, with approximately 120-ohm characteristic impedance. Category-5 rated commu nications cable is used in RS-485 networks and its characteristics are defined in Table 2-2 below. This is the recommended cabling for RS-485 communications. The cable connection includes a differential line (+ and -) and a GND connection.
Specification Recommendation Capacitance (conductor to conductor) <20 pF/ft. Characteristic Impedance 100 – 120 ohms Nominal DC resistance <100 ohms/1000 ft. Wire gauge 24 AWG stranded Conductors/Shielding >2 pair (shielding is recommended)
Table 2-2: Category 5 Cable Characteristics
2.6.2.2. RS-485 C
ABLE LENGTHS
As outlined in the RS-485 specification, the total length of the communication cable (adding up all of the segments of the run) should not exceed 1200 meters (4000 feet). Although the RS-485 specification calls for a maximum cable length of 1200 meters and provides a maximum baud rate well above that of the V­Station device, a more conservative system should be configured to no more than 1000 meters and run at a baud rate of 9600 bits per second. After the network is configured and is running in a stable manner, the baud rate can be increased if faster network communications are desired.
Drops (down-leads, stubs, T-connections, etc.) to equipment are not recommended, but if required, should not exceed one foot) and should use the same cable recommended above. On a long stub, a signal that travels down the wire reflects to the main line after hitting the input impedance of the device at the end. This impedance is high compared with that of the cable and the net effect is degradation of signal quality on the bus.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2.6.2.3. RS-485 N
ETWORK TOPOLOGY
Communication cables for RS-485 should be laid out in a daisy chain configuration (See Figure 2-3 below). Long stubs or drop downs and the star configuration should be avoided because they create discontinuities and degrade signal quality. The star configuration usually does not provide a clean signaling environment even if the cable runs are all of equal length. The star configuration also presents a termination problem, because terminating every endpoint overloads the driver. Terminating only two endpoints solves the loading problem, but creates transmission line problems at the unterminated ends. A true daisy chain configuration avoids these problems.
2-10
Planning the Installation
NOTICE
The device on the end of the network should be terminated with a 120 ohm resistor.
Star Daisy Chain
Figure 2-3: Network Topologies - Star and Daisy Chain Configurations
2.6.3. E
THERNET
If your system is to be configured for use over Ethernet, the wiring will be slightly different. Communication cables for Ethernet logically form a straight line bus bu t the more devices on that bus, the less efficient the network becomes due to increased collisions, and the weaker the signal will get over distance. Repeaters can be used to boost the signal strength; however, a better solution is to place switches at intermediate positions along the bus. The most common Ethernet topology in use today is the star configuration with a hub or switch in the center.
2.6.4. WIRELESSNETWORK DESIGN CONSIDERATIONS
A wireless network of V-Station 4G and V-Flex 4G devices offers several advantages over wired networks, such as convenience, speed of installation, and less wi ring. If you are planning to design a wireless network, consider these points:
Wireless signal interference - Metal masses such as HVAC ducts, fire doors, vents, stairs, etc. disrupt wireless signals. Building and stairwell structures, as well as internal building walls, also impede wireless signals. Some electrical equipment, such a s microwaves, large-screen TVs, cordless telephones are also known to affect wireless signals. Consider the proximity of devices to these objects.
Distance from access points - How far a device is from the closest access point plays a major factor in determining the stability and strength of the wireless signal.
Multiple Access Points - "Repeaters" or multiple access points can solve signal strength problems that may be caused by either distance or loss due to interference.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-11
Planning the Installation
2.7. C
HOOSE POWER SOURCE
V-Station 4G and V-Flex 4G devices can be powered by several methods:
12V DC regulated adapter/bullet jack
Power Over Internet (POE) through an inline PoE 802.3af power injector
3-pin mini connector with dedicated power source.
Power sources should be:
Isolated from other equipment
Filtered
Protected by an Uninterruptible Power Supply (UPS) or battery backup
Protected by a voltage suppression device if transient electrical surges are an issue in the
location.
When planning a system, know the power requirement of each device. If multiple devices are to share a common power supply, exercise care to avoid excessive voltage loss on the wires. Volt­age loss can lead to communication problems when devices are talking and/or listening on dif­ferent ground references.
Voltage loss is directly proportional to wire resistance and the current the wire carries. Always place the device as close as possible to the power supply and always select a wire size appropriate for the load. V-Station 4G devices run on DC power between 12.5 and 24 VDC.
Power requirements for all V-Station 4G and V-Flex 4G models are listed below in Table 2-3.
Power Requirement: 12 watts Input Voltage Range: 12-24.0 VDC Peak Current (12 VDC) 1 A Peak Current (24 VDC) 500 mA
Table 2-3: V-Station 4G and V-Flex 4G Power Requirements
Most power supplies on the market today provide good input and output isolation. However, power supplies which do not provide isolation (or have high leakage capacitance), coupled with accidental AC power line interchanges, present serious ground fault problems for installers. With a ground fault, the signal reference between subsystems may be 115 VAC apart. If these sub­systems are interconnected, the large potential difference can cause equipment damage or per­sonal injury. L-1 EAS recommends using a dedicated regulated DC power supply.
All factory-supplied power supply assemblies are either switching or regulated lin ear supplies and are isolated for safety and to minimize ground loop problems.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
2-12
Install Software
Chapter 3 - Install Software
Chapter Overview
This chapter shows how to install, repair, modify, upgrade, and uninstall the SecureAdmin Server and Client software packages.
Chapter Index
3. Install Software ................................................................................................................................... 3-2
3.1. SecureAdmin Server .......................................................................................................... 3-2
3.1.1. Repairing an Installation of SecureAdmin Server .............................................. 3-7
3.1.2. Uninstalling SecureAdmin Server ...................................................................... 3-7
3.1.3. Upgrading an Installation of SecureAdmin Server ............................................. 3-7
3.2. SecureAdmin Client ........................................................................................................... 3-8
3.2.1. Modifying an Installation of SecureAdmin Client ............................................ 3-12
3.2.2. Repairing an Installation of SecureAdmin Client ............................................ 3-12
3.2.3. Uninstalling SecureAdmin Client .................................................................... 3-12
3.2.4. Upgrading an Installation of SecureAdmin Client ........................................... 3-13
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-1
Install Software
3. INSTALL SOFTWARE
To install the SecureAdmin software, the user must have Administrative rights. Any software required to install SecureAdmin is detected and installed automatically during the setup process.
3.1. S
ECUREADMIN SERVER
To install the SecureAdmin Server software, follow these steps:
1. Insert the CD into the optical drive. If Autoplay is enabled, the installation process will start automatically. A menu is displayed (see Figure 3-1). If Autoplay is not enabled, start the installation process manually by doubleclicking the Setup.exe file located in the "Bioscryptsetup" folder on the root of the CD.
2. Click Server Installation. The InstallShield Wizard starts and the target system is examined for prerequisite software. Any necessary software is listed (see Figure 3-2).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 3-1: Install Menu
Figure 3-2: Prerequisites
3-2
Install Software
3. Click Install. Microsoft .NET Framework 3.5 is installed. Restart the computer when asked (see Figure 3-3). The installation process continues automatically after the computer is restarted.
Figure 3-3: Restart Message
4. Click Install. Microsoft .NET Framework 3.5 is installed. Restart the computer when asked (see Figure 3-3). The installation process continues automatically after the computer is restarted.
5. The Secure Admin Server Installation Wizard is displayed (see Figure 3-4). Click Next to continue the setup process.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 3-4: SecureAdmin Server Installation Wizard
3-3
Install Software
Figure 3-5: SecureAdmin Server License Agreement
6. The L-1 EAS License Agreement is displayed. Select the appropriate radio button to agree with the terms and then click the Next button.
7. The Choose Destination Location screen is displayed (see Figure 3-6). Accept the default installation folder and click the Next button or click Browse to choose your own installatio n path. After you specify a destination folder, the Database Selection screen is displayed (see Figure 3-7 on the next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 3-6: SecureAdmin Server Choose Destination Location
3-4
Install Software
Figure 3-7: Database Selection
8. Using the radio buttons, select the type of database application you intend to work with, or select an existing database. Click the Next button.
If you selected the SQL Server 2005 Express Edition option: a. Select SQL Server 2005 Express Edition option to select locally available database. If a
local SQL Server 2005 Express Edition is not available on install machine, then SecureAdmin will install SQL Server on the local machine.
b. Select Windows authentication or Database server authentication option and enter valid
login ID and password values.
c. Enter the name of the database catalog or click Browse to select an existing database
catalog.
d. Click Next to continue.
If you selected the Oracle 10G Express Edition option, it will be installed locally if it is not already installed.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-5
Install Software
If you selected the option to connect to an existing SQL database: a. Browse to the existing SQL Server available on the local network.
b. Select the Database server authentication option and enter valid Login ID and password
values.
c. Accept the default database catalog or click Browse to select a different database
catalog.
d. Click Next to continue.
9. The SecureAdmin Server Login screen is displayed. Enter a User Name and Password for SecureAdmin server as default credentials. The password should be 8 to 30 characters long and should contain at least one letter, one number, and one non-alphanumeric character.
10. Click Next to continue.
11. Click Finish. This completes the SecureAdmin server installation and exits the installer.
WARNING
L-1 EAS recommends using a single installation of SecureAdmin Server and a single database per site. Multiple databases cannot be combined.
NOTICE
A SecureAdmin server cannot be hosted on a Virtual Machine. The SA server listens for incoming connections from SecureAdmin clients on
TCP port 9005. This port is automatically opened as an exception in the Win­dows Firewall during server component installation.
If you have any other firewalls (software or hardware) between the Secu­reAdmin server and SecureAdmin clients that wish to reach it, TCP port 9005 must be opened and forwarded to the server.
V-Series 4G devices listen for connections from the server on TCP port
10001. This port must be opened on any firewalls (if any) between the server and the devices it manages. This is unlikely in a typical LAN scenario, but possible if server is offsite and managing devices at a remote site.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-6
Install Software
3.1.1. R
EPAIRING AN INSTALLATION OF SECUREADMIN SERVER
To repair an installation:
1. Login as Administrator and go to the SecureAdmin installer.
2. Double-click the Setup.exe installer file to start the installer.
3. On the L1 Identity Solutions screen, select the Server Installation option.
4. On the SecureAdmin Welcome screen, select the Repair option. Click Next to continue.
5. On the Maintenance Complete screen, click the Finish button to complete the repair installation process.
3.1.2. U
NINSTALLING SECUREADMIN SERVER
Uninstall SecureAdmin Server by using either the Add/Remove Program function in Windows or by using the Remove option from the installation file as outlined below.
You can also uninstall SecureAdmin Server by using the Remove option within the installation file. Follow the instructions above for repairing an Installation. Select the Remove option instead of the Repair option, then follow the prompts.
3.1.3. U
PGRADING AN INSTALLATION OF SECUREADMIN SERVER
To upgrade a previous version of SecureAdmin Server, first uninstall the older version using Windows Add/Remove Programs or the SecureAdmin installer, then re-in stall SecureAdmin Server.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-7
Install Software
3.2. S
ECUREADMIN CLIENT
To install the SecureAdmin client software, follow these steps:
1. Insert the CD into the optical drive. If Autoplay is enabled, the installation process will start automatically. A menu is displayed (see Figure 3-8). If Autoplay is not enabled, start the installation process manually by doubleclicking the Setup.exe file located in the Bioscryptsetup folder on the root of the CD.
Figure 3-8: Menu
2. Click Client Installation. The InstallShield Wizard is started and the target system is examined (see Figure 3-9 below). The Welcome screen is displayed (see Figure 3-10 on the next page).
Figure 3-9: InstallShield Wizard
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-8
Install Software
Figure 3-10: Welcome
3. Click the Next button to continue. The License Agreement screen is displayed (see Figure 3-11).
4. The L-1 EAS License Agreement is displayed. Select the appropriate radio button to agree with the terms and then click the Next button. The Choose Destination Location screen is displayed (see Figure 3-12) on the next page.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 3-11: SecureAdmin Client License Agreement
3-9
Install Software
Figure 3-12: SecureAdmin Client Choose Destination Location
5. Accept the default installation folder and click the Next button or click Browse to choose your own installation path. After you specify a destination folder, the Fingerprint Selection Feedback selection screen is displayed (see Figure 3-13).
6. Select the appropriate radio button to either display or to not display fingerprint data. If Display Fingerprint Image is selected, a fingerprint will be displayed while enrolling templates. If the Display Fingerprint Placement Feedback option is selected, then SecureAdmin displays crosshair placement feedback instead of fingerprint images while enrolling templates.
7. Click the Next button. The InstallShield Wizard completes the installation and displays a Finished screen (see Figure 3-14 on the next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 3-13: Fingerprint Placement Feedback Option Selection
3-10
Install Software
Figure 3-14: InstallShield Wizard Finished
8. Select either or both of the optional Check Create Desktop Icon and Launch Secure Admin Client check boxes.
9. Click the Finish button.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-11
Install Software
3.2.1. M
ODIFYING AN INSTALLATION OF SECUREADMIN CLIENT
To modify an installation:
1. Login as Administrator and go to the Secure Admin installer.
2. Double-click the Setup.exe installer file to start the installer.
3. On the L1 Identity Solutions screen, select the Client Installation option.
4. On the Secure Admin Welcome screen, select the Modify option. Click Next to continue.
5. Select the appropriate Fingerprint Placement Feedback option. If Display Fingerprint Image is selected, fingerprints will be displayed while enrolling templates. If Display Fingerprint Placement Feedback is selected, SecureAdmin displays crosshair feedback instead of fingerprint images while enrolling templates.
6. Click Next to continue.
7. On the Maintenance Complete screen, click the Finish button to complete the modified installation.
3.2.2. R
EPAIRING AN INSTALLATION OF SECUREADMIN CLIENT
To repair an installation:
1. Login as Administrator and go to the Secure Admin installer.
2. Double-click the Setup.exe installer file to start the installer.
3. On the L1 Identity Solutions screen, select the Client Installation option.
4. On the SecureAdmin Welcome screen, select the Repair option. Click Next to continue.
5. On the Maintenance Complete screen, click the Finish button to complete the repair installation process.
3.2.3. U
NINSTALLING SECUREADMIN CLIENT
Uninstall SecureAdmin Client by using either the Add/Remove Program function in Windows or by using the Remove option from the installation file.
To uninstall SecureAdmin client by using the Remove option within the installation file, follow the instructions for repairing an installation. Select the Remove option instead of the Repair option, then follow the prompts.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-12
Install Software
3.2.4. U
PGRADING AN INSTALLATION OF SECUREADMIN CLIENT
To upgrade a previous version of SecureAdmin Client, first uninstall the older version using Windows Add/Remove Programs or the SecureAdmin installer, then re-install the new version of SecureAdmin Client.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-13
This page left blank intentionally
Install Software
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
3-14
Install Hardware
CHAPTER 4 - INSTALL HARDWARE
Chapter Overview
This chapter explains how to install a V-Station 4G or V-Flex 4G device, how to mount a wall plate, how to attach a device to a wall plate, and how to make the required electrical connections to the device.
Chapter Index
4. Install Hardware ................................................................................................................................. 4-2
4.1. Wall Mounting Schemes .................................................................................................... 4-2
4.2. Installing a Mounting Plate ................................................................................................. 4-2
4.3. Installation Hardware ......................................................................................................... 4-5
4.4. Attach Device to Mounting Plate ........................................................................................ 4-5
4.5. Connect Device to Earth Ground ....................................................................................... 4-6
4.6. Connect Device to Power Source ...................................................................................... 4-7
4.7. Connect Device to Network ............................................................................................... 4-9
4.7.1. Ethernet Network Connections .......................................................................... 4-9
4.7.2. RS-232/RS-485 Network Connections .............................................................. 4-9
4.7.3. Wireless Network Connections ....................................................................... 4-11
4.8. Connect Device to Door .................................................................................................. 4-12
4.9. Aux Port .......................................................................................................................... 4-14
4.10. Install Ferrite Core ........................................................................................................ 4-15
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-1
4. INSTALL HARDWARE
4.1. W
ALL-MOUNTING SCHEMES
The V-Station 4G and V-Flex 4G devices are mounted, by use of a mounting plate, either di­rectly to a wall or to an electrical box recessed in the wall. The V-Station 4G device can be flush mounted only. The V-Flex 4G device can be either flush or recess-mounted on a wall. Refer to Figures 4-1 and 4-2 on the next page.
4.2. I
NSTALLING A MOUNTING PLATE
The procedure for mounting a wall plate directly to a wall is as follows:
1. Hold the mounting plate onto the wall in the desired location, trace the square hole that will be cut out, and mark the mounting screw locations. Note that for the V-Flex 4G, the large square hole is at the bottom and for the V-Station 4G the hole is to the right.
2. Cut out the square hole with a jigsaw or drywall saw. If the V-Flex 4G device is to be recess­mounted, cut out a hole in the drywall to accommodate the rear extension on the device housing.
3. Drill holes for the nylon wall anchors and install them.
4. Fish wires through the wall to the square hole.
5. Align the hole in the wall plate with the hole in the wall.
6. Fasten the mounting plate to the nylon wall anchors in the wall with the provided screws.
If the V-Flex 4G device is to be recess-mounted on an electrical box, a double gang box is required to accept the rear extension of the housing.
If mounting the V-Station 4G device to an electrical box, attach the mounting plate to a single gang box and use wall anchors on the remaining four holes for additional security.
To install the mounting plate on to an electrical box, screw the mounting plate to the box with the provided 6-32 screws.
Install Hardware
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
CAUTION
When installing a recess-mounted V-Flex 4G device, be careful not to dam­age the tamper switch, as careless handling can shear it off.
4-2
Figure 4-1: V-Flex 4G Flush-mount Mounting Plate
Install Hardware
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-2: V-Flex 4G Recessed-mount Mounting Plate
4-3
Install Hardware
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-3: V-Station 4G Mounting Plate
NOTICE
The V-Station 4G device can only be flush mounted.
4-4
Install Hardware
4.3. I
NSTALLATION HARDWARE
Quantity Component
Hardware
1 Wall mounting plate/mullion mounting plate 6 #6-32 3/4" Philips pan-head screw 6 #6 1" Philips pan-head self-tapping screws 6 #4-8 1" nylon wall anchors
The hardware shown above is provided to mount the mounting plate to the wall and the V­Station 4G or V-Flex 4G device to the mounting plate.
4.4. A
TTACH DEVICE TO MOUNTING PLATE
Once all the electrical connections have been made to the device, it can be attached to the mounting plate as follows:
For the V-Flex 4G, insert the four hooked protrusions on the rear of the device into the corre­sponding slots on the mounting plate. Hold the device against the plate and gently press it in a downward direction to engage the hooks. Insert the star-shaped screw at the bottom center of the mounting plate and tighten with the wrench provided. Do not over-tighten.
For the V-Station 4G, hold the device with the top slightly tilted toward you, at about a 30-degree angle to the wall. Hold the bottom of the device against the mounting plate and lower it so that the two hooks on the bottom of the mounting plate engage the corresponding slots on the de­vice. When the hooks are properly engaged, the top of the device can be pivoted up against the mounting plate. It will drop down slightly, locking itself in the closed position, and should be se­cured in this position with the star-shaped screws in the holes at the right and left ends on the bottom of the device. Do not over-tighten.
With the securing screws removed, the V-Station 4G device can be pivoted down 90 degrees from the wall, as shown in Figure 4-4, to allow access for making connections, etc. The device can be removed from the mounting plate by tilting it at an angle approximately 30 degrees to the wall and gently lifting it up off the hooks on the mounting plate.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Pivot Point
Figure 4-4: Device Open for Installation or Service
4-5
Install Hardware
4.5. CONNECT DEVICE TO EARTH GROUND
The device's ground connection must be properly connected to avoid damage by Electro-Static Discharge (ESD).
To connect the device to earth ground, connect Pin 3 of the mini connector (located on the rear of the device) to earth ground. This terminal should not be connected to the neutral, to the cable shield, or to any other wire except earth ground. See Figure 4-5, below. The connection to earth ground should use the largest wire possible (12 AWG) and be as close to the termination point (water pipe, etc.) as possible.
Power
Power
3-pin Mini Connector (Pin 3 is Earth Ground)
Earth Ground
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-5: Earth Ground Connection
4-6
Install Hardware
4.6. C
ONNECT DEVICE TO POWER SOURCE
The V-Station 4G and V-Flex 4G devices can be powered either by 12V DC power sources or through a Power Over Ethernet (PoE) injector.
The two options for providing 12V power to V-Station 4G and V-Flex 4G devices are by using an external wall plug-in adapter, as shown in Figure 4-6, or through external wiring and a mini plug as shown in Figure 4-7.
NOTICE
Both devices must be earth grounded using the 3-pin mini-connector, regard­less of what power source is being used.
Plug-In 12 VDC
Adapter
2.1 mm Tip Center = Positive
Figure 4-6: Connections for an External Wall Adapter
External 12 VDC
Power Source
Earth Ground
1 – PWR 2 – GND 3 – EARTH
Mini
Connector
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-7: Connections for an External Power Source
4-7
Install Hardware
The V-Station 4G and V-Flex 4G devices both support Power over Ethernet (PoE), using their RJ-45 Ethernet interface. When these devices are to be powered over Ethernet, an IEEE
802.3af compliant Active Midspan Injector must be used (see Figure 4-9). Such an injector is not
supplied with L-1 EAS products. An example of a suitable PoE injector is Model No. AT-6101G from Allied Telesis Inc. (http://www.alliedtelesis.com).
Any such device should carry at least one of the certifications shown below in Figure 4-8 and should be FCC listed.
Figure 4-8: Certification Marks
V-Station
110 VAC
PoE
4G
Injector
RJ45
RJ45
CAT5
RJ45
Host
Computer
Earth Ground
RJ45
Figure 4-9: Power Over Ethernet Connection
Specifications for suitable PoE Injectors are as follows: Input voltage: 90-264 VAC, 60 Hz
Input current: 0.4A @ 100 VAC Output voltage: -48 VDC Output current: 0.32A Power: 15.36 W
For Power over Ethernet, RJ-45 pin numbers 4, 5 are considered VB1(+) positive DC supply, and pin numbers 7, 8 are VB2(-) DC return.
Detailed RJ-45 pin assignments for PoE are given in Table 4-1 (on the next page), and the physical location of the pins in the RJ-45 connector is shown in Figure 4-11 (on the next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-8
Install Hardware
SOURCE LOAD REMARKS
STANDARD
IEEE 802.3af
using spare
pairs
4.7. C
ONNECT DEVICE TO NETWORK
Ethernet RJ-45 connector pin number
Source
Voltage
48 V DC,
protected
1 2 3 4 5 6 7 8
RX RX TX DC+ DC+ TX DC- DC- (embedded)
Load
Voltage
DC Load
Connector
Table 4-1: PoE Pin Assignments
Figure 4-10: RJ45 Pin Location
Industry
Standard for
embedded
PoE
The V-Station 4G and V-Flex 4G devices support both RS-232/RS-485 and Ethernet 10baseT and 100baseTX network protocols.
4.7.1. E
THERNET NETWORK CONNECTIONS
Ethernet connections to the device are made through a standard RJ-45 connector on the back of the device. Refer to Figure 4-10 and Table 4-1 for RJ-45 pin assignments and locations.
4.7.2. RS-232/RS-485 N
ETWORK CONNECTIONS
To connect a device to an RS-232 or RS-485 network, connect the appropriate wires to the provided pigtail in accordance with the pin-out diagram in Figure 4-11 (next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-9
Install Hardware
Connector Pin No. Wire Color Connector Pin No. Wire Color Pin1 (RS485A) Blue Pin2 (RS232_RX) Violet/White Pin3 (RS485B) Blue/Black Pin4 (RS232_TX) Violet Pin5 (SGND) Black/Red Pin6 (SGND) Black/Red Pin7 (WIEGAND_LED_IN0) Grey/Black Pin8 (WIEGAND_DIN0) Green/White Pin9 (Not Connected) Pin10 (WIEGAND_DIN1) White/Black Pin11 (WIEGAND_LED_OUT0) Brown/Green Pin12 (WIEGAND_DOUT0) Green Pin13 (WIEGAND_LED_OUT1) Brown/Black Pin14 (WIEGAND_DOUT1) White Pin15 (TTLOUT_0H) White/Brown Pin16 (WGND) Black/White Pin17 (TTLOUT_0L) White/Red Pin18 (TTLIN0) Yellow/Blue Pin19 (TTLOUT_1H) Brown/White Pin20 (TTLIN1) Blue/Brown Pin21 (TTLOUT_1L) Yellow/Black Pin22 (TTLIN2) Brown/Violet Pin23 (TTLOUT_2H) Grey/Orange Pin24 (TTLGND) Green/Brown Pin25 (TTLOUT_2L) White/Green Pin26 (RELAY_NC) Orange Pin27 (RELAY_NO) Yellow Pin28 (RELAY_COM) Grey
Figure 4-11: Pin-out Diagram
When connecting the device to the network, the following procedures must be followed:
Use Category 5 cabling with a characteristic impedance of 120 ohms for RS-485
networks. Category 5 cables with a characteristic impedance of 100 ohms can also be used, but with lower performance.
Cable manufacturers provide cables with multiple twisted pairs designed for this
type of communication (characteristic impedance is 120 ohm).
Unused pairs within the cable must be terminated with characteristic impedance
(100 or 120 ohm) on both ends.
AWG 24 should be considered as the minimum gauge.
Choose one twisted pair of conductors to use for RS-485 differential connection s,
other conductors should be used for Signal Ground (RS-485 GND on Weidmuller connection).
The RS-232 to RS-485 converter must support Sense Data to be able to switch
from Send to Receive mode.
Check each device's cabling for ground faults before connecting to an RS-485 n et-
work.
Each device should have pin 3 of the mini-connector connected to earth ground. After all devices are configured and connected to the RS-485 network, the baud rate
can be increased to the highest supported rate (some experimentation might be re­quired).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-10
Install Hardware
4.7.3. W
IRELESS NETWORK CONNECTIONS
For installations on a wireless network, the same connection procedures should be followed to connect the device to the wireless network devices. After the wireless network has been installed, it needs to be set up either through SecureAdmin (see Chapter 7 in the Operator's Manual) or through the front panel of the V-Station 4G device.
To set up wireless operation through the front panel of a V-Station 4G device, perform the following steps:
1. Power up the device.
2. Ensure that the wireless network is functioning.
3. Use one of these supported modes:
WEP Open
WPA Personal
WPA2 Personal.
NOTICE
L-1 EAS does not recommend using the "No encryption" mode.
4. Enter the Admin menu on the device by pressing the Left arrow and Enter keys
simultaneously.
5. Key in the Admin password (default is "0000") and press OK.
6. Select the Communications icon and press OK
7. Select "Network Interface" and press OK.
8. Select "WLAN" and press OK.
9. Select "Scan for wireless network" and press OK.
10. Select "Enable" and press OK.
11. Select "Encryption mode" and press OK.
12. Choose the type of encryption your network is using and press OK.
13. Enter the key.
14. Select "DHCP" or "Static" and press OK. If you selected "DHCP", the device
reboots. Afterwards, it will have a dynamic IP address. If you selected "Static IP", specify an IP, a Net Mask, a Gateway, and then press OK. The device reboots.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-11
Install Hardware
After rebooting, check for a "Wireless" icon on the device's LCD. Press the Left arrow key to display Wireless info. If wireless operation is set up correctly, pertinent wireless network information is displayed. If no information is displayed, then the wireless setup is not set correctly.
SecureAdmin can scan for and auto-detect wireless devices. If you want to use SecureAdmin to scan for wireless devices, ensure that the "multicasting" option is enabled in your router.
NOTICE
The maximum recommended distance from an access point is 25 feet.
ONNECT DEVICE TO DOOR
4.8. C
The V-Station 4G and V-Flex 4G devices incorporate an internal relay that enables them to op­erate a deadbolt/door strike directly.
WARNING
The internal relay is limited to a maximum current of 170 mA. If the deadbolt/ doorstrike to be controlled draws more than 170 mA, damage to the device may occur. If the deadbolt/door strike load exceeds 170 mA, an external re­lay must be used, as described below.
Do not use the same power supply to power a V-Series 4G device and a door strike.
Assuming the current drawn by the deadbolt/door strike is less than 170 mA, the connections between the V-Station 4G or V-Flex 4G device, deadbolt/door strike, and power supply for the deadbolt/door strike should be made as shown in Figure 4-12 (on the next page). Note that a snubber diode (1N4007 or equivalent) must be connected across the deadbolt/door strike to protect the DC power supply from inductive kickback.
CAUTION
The snubber diode and DC power supply for the deadbolt/door strike are not supplied with the V-Station 4G and V-Flex 4G devices. The power supply should be specified in accordance with the voltage and current requirements of the deadbolt/door strike, but it must be ensured that the current to operate the deadbolt/door strike does not exceed 170 mA.
If the current required to operate the deadbolt/door strike exceeds 170 mA, an external relay must be used in conjunction with the V-Station 4G or V-Flex 4G device. The external relay must be specified so that its contacts are rated to carry the current required by the deadbolt/door strike, and that the current required to operate its energizing coil is within the 170 mA capacity of the V-Station 4G or V-Flex 4G device's internal relay.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-12
Install Hardware
27 - N.O. (Normally Open) 28 - Common
V-Station 4G or V-Flex 4G
Deadbolt/Door
strike
Max load 170 mA
Figure 4-12: Connections for Internal Relay Operation
The power supply for the external relay must be chosen to match the operating voltage and cur­rent of the external relay coil, but its voltage must not exceed the V-Station 4G or V-Flex 4G de­vice's internal relay maximum voltage rating of 250 volts.
The external relay should be connected in accordance with Figure 4-13 below. Note that snub­ber diodes (1N2007 or equivalent) should be connect ed across the external relay coil and the deadbolt/door strike.
Snubber
Diode
External
Relay
External
Relay Coil
External Relay Contacts
COM N.O. N.C.
+
DC Power Supply for External Relay
DC Power Supply
-DC +DC
27 - N.O. (Normally Open) 28 - Common
V-Station 4G or V-Flex 4G
Deadbolt/Door Strike
Con 1 Con 2
Snubber Diode 1N4007
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-13: Connections for External Relay Operation
4-13
Install Hardware
4.9. A
UX PORT
The Aux port is a USB 2.0 auto-negotiate connector located on the bottom of the device (see Figure 4-14). To access the Aux port, the Aux port door must first be removed. Use the provided pin-in-hex security key to remove the #6-32 security screw retaining the plastic Aux port door. Gently remove the plastic Aux port door to reveal the USB connector.
To attach a USB memory key (see Figure 4-15) or other "gadget" serial device by way of the Aux port, use the USB Type A female to USB Micro A/B male adapter cable provided in the in­stallation kit.
The Aux port is used to transfer files to and from the device. Audio, images, firmware, logs, and configuration files can be transferred quickly and easily to a device without the need for a com ­puter.
CAUTION
Current rating of the Aux port is not to exceed 100 mA Maximum.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-14: Location of Aux Port (V-Station 4G)
Figure 4-15: USB Memory Key
4-14
Install Hardware
4.10. I
NSTALL FERRITE CORE
In order for the V-Station 4G and V-Flex 4G devices to comply with FCC Class B & CISPR 22 Class B regulations, the installer and/or end user is required to use the supplied Ferrite Materi al on the Ethernet, DC, and all I/O cables exiting the rear of the device. This ferrite material is lo­cated within the installation kit that is supplied with each product.
Ethernet Ferrite P/N: STEWARD 28A2432-0A2 DC & I/O Lines P/N: STEWARD 28A4155-0A2
Install the ferrite cores as close to the device as possible, as shown in Figure 4-16 below.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 4-16: Installation of Ferrite Cores
4-15
This page left blank intentionally
Install Hardware
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
4-16
System Start-up Procedures
CHAPTER 5 - SYSTEM START-UP PROCEDURES
Chapter Overview
This chapter explains the various start-up procedures and checks that should be performed before applying power to a device.
Chapter Index
5. System Start-up Procedures .............................................................................................................. 5-2
5.1. System Start-up Overview ................................................................................................. 5-2
5.2. Device Configuration Check .............................................................................................. 5-2
5.3. RS-232 to RS-485 Converter Ground Fault Check ........................................................... 5-3
5.4. Device Ground Fault Check................................................................................................ 5-3
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
5-1
System Start-up Procedures
5. SYSTEM START-UP PROCEDURES
To avoid the need for difficult troubleshooting, system start-up must follow this step-by-step procedure. Never wire up a system and apply power to it all at once.
5.1. S
YSTEM START-UP OVERVIEW
L-1 EAS recommends always following these system start-up steps:
1. Do not apply power to any device.
2. Check all wiring and device configurations.
3. Disconnect all devices from the communication line.
4. Check the supply voltage for correct voltage.
5. Power up the PC running SecureAdmin.
6. Power up the RS-232 to RS-485 converter (if installed).
7. Configure SecureAdmin.
8. Perform a ground fault check for the converter (if installed).
9. Connect the PC and converter (if installed) to the communication line.
10. Verify that the device powers up correctly, but do not connect it to the communication line. The power LED should be illuminated. Check the power lines with a voltmeter.
11. Perform a ground fault check for the device (if using RS-485, see Section 5.4 on next page).
12. Connect the device to the communication line.
13. Verify that the device communicates with SecureAdmin.
14. If there are more device, repeat Steps 10 through 13 for each device.
EVICE CONFIGURATION CHECK
5.2. D
Devices must be configured correctly before they can communicate. Common pr oblems include incorrect Host Port Protocol settings, mismatched Baud rates, and incorrect device Net­work IDs. Each device sharing a communication line must have a unique device Network ID.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
5-2
System Start-up Procedures
5.3. RS-232
TO RS-485 CONVERTER GROUND FAULT CHECK
Before a device can be connected to an RS-485 subsystem, it must be checked for ground faults. An uncorrected ground fault can damage all devices connected to the RS-485 communication line.
To check for a ground fault on the RS-232 to RS-485 converter:
1. Apply power to the RS-232 to RS-485 converter.
2. Connect the signal ground of the RS-485 line through a 10k ohm current-limiting resistor to the signal ground of the RS-232 to RS-485 converter. There should be no more than 1 volt across the resistor.
5.4. D
EVICE GROUND FAULT CHECK
To check for a ground fault on a new V-Station 4G or V-Flex 4G device:
1. Apply power to all devices already successfully connected to the RS-485 line.
2. Power up the new device but do not connect it to the RS-485 line.
3. Connect the signal ground of the RS-485 line through a 10k ohm current-limiting resistor to the signal ground of the V-Station 4G device.
4. There should be no more than 1 volt across the resistor. If there is, find and clear the fault.
5. Repeat Steps 1 through 3 with each of the RS-485 signal lines (+ and -).
6. Connect the new device to the RS-485 line only if no ground fault is found.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
5-3
This page left blank intentionally
System Start-up Procedures
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
5-4
Configure Device
CHAPTER 6 - CONFIGURE DEVICE
Chapter Overview
This chapter explains how to configure a device and calibrate a device sensor using the SecureAdmin Client application.
Chapter Index
6. Configure Device................................................................................................................................. 6-2
6.1. Register Device................................................................................................................... 6-2
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
6-1
Configure Device
5. CONFIGURE DEVICE
V-Station 4G and V-Flex 4G devices must be configured before use. This includes setting various com­munication parameters and calibrating the device's sensor
EGISTER DEVICE
5.1. R
After a device is physically installed, it must registered. This can be done several ways -- when a device is connected by means of a network (this is the recommended method), or when the device is connected directly to the host computer upon which SecureAdmin is ru nning.
To register a networked device:
1. Launch SecureAdmin.
2. Double-click the Network tab. Three buttons are displayed (see Figure 6 -1).
3. Click the Register via Server button. A Register via Server dialog box is displayed (see Figure 6-2 on the next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 6-1: Network Sidebar Tab
6-2
Configure Device
Figure 6-2: Register via Server Dialog Box
4. Select the Search Automatically check box.
5. Click the Scan button. SecureAdmin scans the network for connected devices and lists the results. Devices with "plus" signs in their icon are available to add.
6. In the list, click the icon of the device you want to register. A Register Device dialog box is displayed (see Figure 6-3).
Figure 6-3: Register Device Dialog Box
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
6-3
7. Enter a Device Name.
8. Select a Group.
9. Click Register. A Device Summary is displayed (see Figure 6-4).
Configure Device
Figure 6-4: Device Summary Dialog Box
10. Click OK.
11. Click Close. The device is registered.
To register a device via a client:
1. Launch SecureAdmin.
2. Double-click the Network tab. Three buttons are displayed.
3. Click the Register via client button. The Step 1 Find Device dialog box is displayed (see Figure 6-5).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 6-5: Step 1 Find Device Dialog Box
6-4
Configure Device
4. Select either Serial Port - this machine or Ethernet radio button.
5. Enter the appropriate connection details. If you are connecting via USB/RS-232:
Enter the appropriate Port Number (to determine the correct port number, look in the Win­dows Device Manager for a "Gadget Serial" entry under the "Ports (COM & LPT)" heading), Baud Rate, and Device ID.
If you are connecting via RS-485: Enter the appropriate Port Number (to determine the correct port number, look in the Win-
dows Device Manager for your RS-485 entry under the "Ports (COM & LPT)" heading), Baud Rate, and Device ID.
If you are connecting via Ethernet: Enter the network IP Address of the device you want to connect to.
NOTICE
The first time a V-Station 4G or V-Flex 4G device is connected to the com­puter via the USB/RS-232 interface, the Windows Found New Hardware Wizard might start. As all required device drivers are installed when Secu­reAdmin is installed, simply follow the prompts, accepting the default choices when possible, to install the device.
6. Click Next. The Step 2 Device Information dialog box is displayed (see Figure 6-6).
Figure 6-6: Step 2 Device Information Dialog Box
6. Click Next. The Step 3 Server Communication Parameter dialog box is displayed (see Figure 6-7 on the next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
6-5
Configure Device
Figure 6-7: Step 3 Server Communication Parameter Dialog Box
7. Select the radio button that corresponds how the server will connect to the device, either by Serial Port or by Ethernet.
8. If connecting via RS-232 or RS-485, enter the appropriate Port, Baud Rate, and Device ID (if using RS-485, also select the RS-485 check box). If connecting via Ethernet, enter the network IP Address of the device (select the DHCP check box if dynamic IP addressing is used).
9. Click Next. The Step 4 Register Device dialog box is displayed (see Figure 6-8).
Figure 6-8: Step 4 Register Device Dialog Box
10. Enter a Device Name.
11. Select the Group the device will belong to from the drop-down menu.
12. Click Register. The Device Summary dialog box is displayed (see Figure 6-9 on the next page).
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
6-6
13. Click OK.
Configure Device
Figure 6-9: Device Summary Dialog Box
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
6-7
This page left blank intentionally
Configure Device
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
6-8
Maintenance and Cleaning
Chapter 7 - Maintenance and Cleaning
Chapter Overview
This chapter explains how to replace and calibrate the fingerprint sensor module, and how to clean the device sensor.
Chapter Index
7. Maintenance and Cleaning................................................................................................................. 7-2
7.1. Field Maintenance............................................................................................................... 7-2
7.1.1. Disarming the Tamper Protection ...................................................................... 7-2
7.1.2. Replacing the Sensor ......................................................................................... 7-3
7.1.2.1. V-Flex 4G ............................................................................................ 7-3
7.1.2.2. V-Station 4G ........................................................................................ 7-5
7.1.3. Calibrating the Sensor ....................................................................................... 7-7
7.2. Cleaning ............................................................................................................................. 7-9
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-1
Maintenance and Cleaning
7. MAINTENANCE AND CLEANING
The V-Station 4G and V-Flex 4G devices require very little in the way of daily maintenance except for occasional cleaning and disinfecting. The V-Station 4G and V-Flex 4G devices feature field-replaceable sensors.
7.1. F
IELD MAINTENANCE
V-Station 4G and V-Flex 4G fingerprint sensors can be replaced quickly and easily in the field. The following sections explain in detail the steps required to replace a sensor.
7.1.1. D
ISARMING THE TAMPER PROTECTION
The Tamper Switch is a momentary push-button switch on the back of the device within the I/O cable interface pocket (see Figure 7-1).
The tamper protection feature allows the device to sound an audio alert, flash LEDs, send a pre-defined Wiegand string to the control panel, or disable biometrics if the tam­per switch is triggered.
Figure 7-1: Tamper Switch Location
With the wall mounting plate mounted and the device secured to the mounting plate, the tamper switch is depressed, closing the electrical circuit. When the device is removed from the wall by removing the security screws or in the event that the device is removed from the wall by force, the tamper switch opens.
To access the tamper-protection setting on the V-Station 4G device using the keypad:
1. Enter the Admin menu on the device by pressing the Left arrow and Enter keys
2. Key in the Admin password (default is "0000") and press OK.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
simultaneously.
7-2
3. Select the System icon and press OK.
4. Select Device Settings and press OK.
5. Select SDC/Tamper Settings and press OK.
6. Select Tamper Settings and press OK. If the alarm has sounded, select Clear and Re-enable. The Tamper protection setting is set to disabled by default.
Maintenance and Cleaning
7.1.2. R
EPLACING THE SENSOR
WARNING
The sensors can only be replaced with the same type as previously used. L-1 EAS does not support changing the type of sensor. Different types of sensors are not interchangeable, and the device will fail to operate.
NOTICE
Power to the device MUST BE DISCONNECTED prior to servicing.
If the device is secured to the wall please be sure to follow the Disable
Tamper settings prior to the removal of the device from the wall.
ESD protective handling procedures must be followed before any service is applied to the device.
7.1.2.1. V-F
To replace the sensor module in a V-Flex 4G device, follow these steps:
1. Remove the security screw and slide the V-Flex 4G device up until the
2. Remove two Philips screws, as shown in Figure 7-2 (on the next page).
3. Gently slide the sensor back plate, sensor mask, and sensor out of the V-
4. Disconnect the sensor module wiring harness from the internal device
LEX 4G
hooks are free from the wall-mounting plate.
Flex 4G device. Be careful not to damage any internal wiring.
connector. It might be necessary to rock the connector back and forth to work it out. Do not pull with excessive force as you might damage the mating connector.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-3
Maintenance and Cleaning
Figure 7-2: Removal of Sensor Module from V-Flex 4G Device
5. Disconnect the sensor module wiring harness from the sensor module. Do not damage the wiring harness as it will be re-used with the new sensor module.
6. Reassembly is the reverse of disassembly.
CAUTION
The parts shown in Figure 7-3 are assembled at the factory and are not meant to be removed by the end user. Removing any of these parts will void the warranty.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 7-3: Non-Removable Parts (V-Flex 4G)
7-4
Maintenance and Cleaning
7.1.2.2. V-STATION 4G
To replace the sensor module in a V-Station 4G device, follow these steps:
1. Remove the security screw.
2. Tilt the device at an angle approximately 90 degrees to the wall.
3. Remove the three Philips screws, as shown in Figure 7-4.
Figure 7-4: Removal of Sensor Module from V-Station 4G Device
4. Gently slide the sensor back plate, sensor mask, and sensor out of the V­Station 4G device. Be careful not to damage any internal wiring.
5. Disconnect the sensor module wiring harness from the internal device connector. It might be necessary to rock the connector back and forth to work it out. Do not pull with excessive force as you might damage the mating connector.
6. Disconnect the sensor module wiring harness from the sensor module. Do not damage the wiring harness as it will be re-used with the new sensor module.
7. Reassembly is the reverse of disassembly.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-5
Maintenance and Cleaning
CAUTION
The parts shown in Figure 7-5 are assembled at the factory and are not meant to be removed by the end user. Removing any of these parts will void the warranty.
Figure 7-5: Non-Removable Parts (V-Station 4G)
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-6
Maintenance and Cleaning
7.1.3. C
ALIBRATING THE SENSOR
After a device sensor is replaced, it must be calibrated before it can be used. To calibrate a device:
1. Select Sensor Calibration in the Tools drop-down menu. The Calibration Wizard dialog box is displayed (see Figure 6-10).
2. Select the device you want to calibrate in the Current Device menu.
3. Click Calibrate. Wait as the device sensor is calibrated.
4. Click Next. The Calibration Wizard Step 2 dialog box is displayed (see Figure 6-11
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 7-6: Calibration Wizard Step 1 of 2 Dialog Box
on the next page).
7-7
Figure 7-7: Calibration Wizard Step 2 of 2 Dialog Box
5. Click Capture.
Maintenance and Cleaning
6. Place a finger on the sensor, hold it, and remove it as directed by the on-screen prompts. The capture results are displayed (see Figure 6-12).
Figure 7-8: Calibration Wizard Capture Results Dialog Box
7. Click Close. The device sensor is now fully calibrated and ready to use.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-8
Maintenance and Cleaning
7.2. C
LEANING
Sensors become soiled with residue, oils, or other contaminants d ue to contact with fingers and exposure to the elements. The sensor surface should be cleaned periodically for performance, aesthetic, and hygienic reasons. Care must be taken when cleaning the sensor to prevent dam­aging the sensor surface or surrounding components.
To clean the fingerprint sensor in a V-Station 4G or V-Flex 4G device:
1. Remove electrical power from the device.
2. Moisten (do not saturate) a clean cotton swab or a lint-free cloth with rubbing (Isopropyl) alcohol.
CAUTION
Do not use chlorine-based cleaners, such as bleach, or chlorine-based bath­room or mildew cleaners. Chlorine-based cleaners will not adversely affect the fingerprint sensor, but they could damage the electronic circuitry sur­rounding the fingerprint sensor.
Do not use solvents such as acetone, methyl ethyl ketone, lacquer thinner, etc. Solvents will not adversely affect the sensor, but they are likely to dam­age the reader housing or other peripheral components.
WARNING
Never use products such as abrasive cleaning powders, steel wool, scouring pads, or fine sandpaper to clean the sensor surface. These types of cleaning products will damage the sensor surface.
3. Rub the sensor surface with the moistened cotton swab or lint-free cloth. Do not allow the cleaning product to drip onto any electronic components near the sensor.
4. Rub the sensor with a clean dry cotton swab or lint-free cloth to remove any traces of clean­ing product.
5. Reconnect power to the device.
NOTICE
Disposable ESD-safe wipes, such as ACL Staticide wipes, can be used to disinfect the sensor and buttons on a daily (or even more frequent) basis. Be aware that some wipes might not offer the same cleaning power as the prod­ucts mentioned above and thus should not be relied upon to thoroughly re­move all residue. Use of wipes does, however, helps keep sensor and button surfaces hygienic and makes an excellent complement to periodic cleaning.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-9
This page left blank intentionally
Maintenance and Cleaning
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
7-8
Troubleshooting
Chapter 8 - Troubleshooting
Chapter Overview
This chapter information about any error messages that might be experienced during the installation process.
Chapter Index
8. Troubleshooting .................................................................................................................................. 8-2
8.1. Installation Error Messages ................................................................................................ 8-2
8.1.1. Error 1303 - Insufficient Privileges ..................................................................... 8-2
8.1.2. Error 27552 - Error Creating Database .............................................................. 8-3
8.1.3. Invalid Password ................................................................................................ 8-4
8.1.4. Error 27502 - User Not Associated with Trusted SQL Server ........................... 8-5
8.1.5. Error 27502 - SQL Server Does Not Exist ......................................................... 8-6
8.1.6. Insufficient System Memory ............................................................................... 8-7
8.1.7. Out of Disk Space .............................................................................................. 8-8
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
8-1
8. TROUBLESHOOTING
NSTALLATION ERROR MESSAGES
8.1. I
These error messages might occur during the SecureAdmin installation process.
Troubleshooting
8.1.1. E
RROR 1303 - INSUFFICIENT PRIVILEGES
This error can occur during SecureAdmin Client installation at the last step (right before “Finish”). If it occurs, it means that the user does not have sufficient rights to install software on the computer.
Log off and log on either as a Administrator or another user that has sufficient privileges to install software and perform the setup process again.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 8-1: Error 1303
8-2
Troubleshooting
8.1.2. E
RROR 27552 - ERROR CREATING DATABASE
Figure 8-2: Error 27552
This error can occur during SecureAdmin Server installation process. If it occurs, it means that the user does not have sufficient privileges to access a specific SQL database.
Contact your IT department to ensure that your privileges are correct for the specified database.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
8-3
Troubleshooting
8.1.3. I
NVALID PASSWORD
This error can occur during SecureAdmin Server in stallation process on the User configuration screen (after the database configuration screen).
If it occurs, it means that the password provided is not strong enough. Click OK, and re­enter a password that is considered more secure. The password should be between 8 and 30 characters long and contain at least one capital letter, one number, and one non-alphanumeric character.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 8-3: Invalid Password
8-4
Troubleshooting
8.1.4. E
RROR 27502 - USER NOT ASSOCIATED WITH TRUSTED SQL SERVER
This error can occur during the SecureAdmin Server installation process. If it occurs, it means that the InstallShield Wizard could not access the specified SQL database.
Check your user name and password or contact your IT department to ensure that your user name is associated with the specified SQL database.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 8-4: Error 27502 - User Not Associated
8-5
Troubleshooting
8.1.5. E
RROR 27502 - SQL SERVER DOES NOT EXIST
This error can occur during the SecureAdmin Server installation process (at the time of database configuration, after the database selection screen). If it occurs, it means that the InstallShield Wizard could not connect to the specified SQL database because it does not exist or because the user is not authorized to access that database
Check your user name and password or contact your IT department to ensure that your user name is authorized to access the specified SQL database.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
Figure 8-5: Error 27502 - Server Does Not Exist
8-6
Troubleshooting
8.1.6. I
NSUFFICIENT SYSTEM MEMORY
Figure 8-6: Insufficient System Memory
This error can occur during the SecureAdmin Server installation process at the first screen after selecting server installation from the options screen.
If it occurs, it means that the computer you are trying to install SecureAdmin Server on does not have sufficient system memory. Install more memory or install on a different machine.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
8-7
Troubleshooting
8.1.7. O
UT OF DISK SPACE
Figure 8-7: Out of Disk Space
This error can occur during the SecureAdmin Client installation proces s when Secu­reAdmin starts to configure components, after the fingerprint feedback options selection.
If it occurs, it means that the computer hard drive you are trying to install SecureAdmin Client on does not have sufficient hard drive space. Install a larger hard drive or install to a another hard drive that has sufficient disk space.
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
8-8
Contact Information
CHAPTER 9 - CONTACT INFORMATION
The L-1 Enterprise Access team endeavors to resolve all inquiries from clients with supported products in a timely fashion. Please visit our webpage for the most up to date information, hours, contacts, and resources available for resolving your technical needs. Please note that some services are pro v ided un­der a support contract or warranty only.
Website: http://www.l1id.com/enterpriseaccess/support North America: Support-EnterpriseAccess@L1ID.com International: Support-Intl-EnterpriseAccess@L1ID.com
9.1. R
EGISTERING YOUR PRODUCT
Registering your L-1 products is quick and easy and entitles you to a wide range of benefits such as notifications of product updates, newsletters, special offers, and invitations to L-1 Enter­prise Access Division events and training seminars.
Please use the following address to register: http://www.L1ID.com/register4G
Part No. 430-4G-200-00-000 © 2009, L-1 Identity Solutions Inc.
9-1
Loading...