Sales / Support – 1-800-331-3921 M-F 8am – 5pm Pacific
Email support - support@mybiocert.com
Instruction Manual – US English
Sold Exclusively Through Authorized Sales Agents of Biometrics Direct
Biometrics Direct – BioCert FS-100 Door Lock Page 1
Acknowledgement –
Thank you for purchasing a BioCert™ FS-100 Door Lock, the ultimate
fingerprint identification locking system. We believe that you will be
impressed with its unparalleled features and performance.
Please keep this document as well as your receipt as proof of purchase
under our 1 Year Manufacturers Limited Warranty.
Product Overview –
· Convenient One-Touch System - Simply touch the
scanner with your fingertip. It is that easy to unlock your
door for users of all ages.
· The scanner prism - The optical prism is high-impact
resistant and can be adapted for outside use under
severe environmental conditions. It is highly anti-static
and resistant against physical damages. It will resist
normal man-made damages like scratches, hammering
and high pressure violation.
· 1:n Identification method - Unlike other door lock systems that ask for a
password first, The BioCert™ FS-100 only requires your fingertip to process user
verification. The BioCert™ FS-100 operates with 1:n identification method having
less than 0.5 seconds of verification time per each fingerprint.
· Memory Capacity for 30 Fingerprints – The BioCert™ FS-100 has high memory
capacity with high speed and high efficiency that enable to input up to 30
different fingerprints.
· Safety “Dead Bolt” - You may bolt the door by turning the safety bolt knob inside.
Anyone else cannot open it from outside.
· Power Supply – The BioCert™ FS-100 is powered by 5 AA 1.5V alkaline
batteries. The power consumption is extremely low and it can support 4000
operations. For a typical family these batteries will last 6-12 months. We
recommend changing your batteries as you would in your fire detectors ~ during
each daylight savings period. Please use high quality – long life alkaline
batteries such as Duracell.
· Stand-by Power supply - There are two stand-by external power supply sockets
beneath the key pad. In case of low battery you can plug in a standard 9 Volt
battery into this socket and the BioCert™ FS-100 will allow you to unlock the
door using your fingerprint.
· Competitive price The BioCert™ FS-100 offers one of the world’s highest levels
of performance and functionality at an extremely competitive price. –
US List Price = $899.95
· Modern Appearance and Advanced Biomechanical Design - BioCert™ FS-100
combines a modern aesthetic appearance with a slightly futuristic biomechanical
design.
·Emergency “Single Step” Egress - Door lock setting has ‘In Free’ function that
enables to open the door easily with turning the doorknob from the inside.
Biometrics Direct – BioCert FS-100 Door Lock Page 2
Table of Contents:
Please read this guide completely before installation and use ........................4
Diagram of FS-100 Door Lock.....................................................................................5
Installation Guide – New Door Frame.......................................................................6
Installing the Batteries..................................................................................................7
This manual is copyright 2003 by Artemis Solutions Group, LLC DBA Biometrics Direct – PO Box 403, Freeland, WA
All rights are hereby reserved.
98249
Biometrics Direct – BioCert FS-100 Door Lock Page 3
Please read this guide completely before installation and use
Please read the user’s guide before using the product for your safety and
proper usage.
After completing the installation, the user has to complete its master
registration in the presence of the installation personnel. Master
registration allows up to 3 persons, and prints of all the 3 master users
should be registered at this point to prevent any unauthorized person’s
registration.
After registering the master, please remember to change the factory set 4digit PIN code (1234). This is to protect the owner’s properties from
misuse.
Our company is not responsible for any harm or loss that occurs by using
non-standardized parts of the product.
For more information and technical support, please contact our customer
service center at 800-331-3921 M-F 8am to 5pm. Our Biometrics Direct
service team will be available to provide you with the best quality
assistance to make sure you are completely satisfied with our products.
For more details about changing the user’s PIN code, refer to the ‘Use the
Keypad’ in the user’s guide.
The information in this document is subject to change without prior notice in order to
improve reliability, design, or function and does not represent a commitment on the part of
this company.
Biometrics Direct – BioCert FS-100 Door Lock Page 4
Diagram of FS-100 Door Lock
Biometrics Direct – BioCert FS-100 Door Lock Page 5
Installation Guide – New Door Frame
Biometrics Direct – BioCert FS-100 Door Lock Page 6
Installing the Batteries
During the initial installation of the system or when the depleted batteries
need to be replaced by new ones, open the back cover plate of the door
lock system and insert the new batteries.
Our fingerprint stand-alone door lock system requires five 1.5V AA
alkaline batteries.
Batteries are placed in one row and five columns, each battery in one
column.
When the batteries are weak and need to be replaced, a beeping sound
from the system will be heard.
Pay attention to the positive and negative (+,-) terminals when you insert
the batteries in the system.
Biometrics Direct – BioCert FS-100 Door Lock Page 7
Keypad Functions
Function Buttons: To be used as setup buttons:
Button Description
ADD Button Setup button for user registration
DEL - Delete Button Setup button for user deletion
‘*’ Button to set PIN codes
‘#’ Button to open the lock
‘0~9’ Keypad Buttons to input the pin codes
Key Override
The BioCert FS-100 comes with three keys for emergency override. Do not lose these
keys as they cannot be replicated.
Biometrics Direct – BioCert FS-100 Door Lock Page 8
Using your BioCert™ FS-100 Door Lock
Registering the “Primary Master”
The “Primary Master” is the person who registers
first on the system and is automatically given the
authority to register two other individuals as
masters.
His (or her) ID number id preset to ‘01’ or 0101 for programming purposes.
When you first receive your lock – there is no master fingerprint
registered on the system. ANY fingerprint will open the door. To Set
the Primary Master Fingerprint use the procedure outlined below -
Step Description
1 Remove the two screws on the bottom of the face cover to reveal
the keypad.
2 Press ‘ADD Button’.
3 The Green light will blink once and the scanner window will light up.
4 When the Yellow light is lit and the scanner window blinks, place
the finger of the Primary Master on the scanning platform – This
registers the first template.
5 The system will beep when the first template is registered.
6 When the Yellow light is lit and the scanner window blinks again,
place the SAME finger on the scanning platform – this registers the
second template. --- CAUTION --- YOU MUST remove your finger
and re-place the same finger on the scanning platform. If the
system registers the same fingerprint in EXACTLY the same place,
it will not register the second template.
6 The system will beep when the second template is registered.
7 The FDS-100 will now compare the two templates registered and
save the Primary Master template to memory.
8 The Green light will blink three times to let you know that the
Primary Master is now registered.
9 You may now replace the face cover or register additional masters
or authorized users
▲ If the registration is accepted by the system, you will hear the beep
sound with the green LED blinking. If failed, the red LED will blink and the
system will beep four times rapidly. That means you need to repeat the
steps outlined above.
Biometrics Direct – BioCert FS-100 Door Lock Page 9
Registering Alternate Masters
The BioCert FS-100 Door Lock enables you to register two Alternate
Masters, beyond the Primary Master.
Master 2 = 0202
Master 3 = 0303
Once registered as a master (either Primary or Alternate), you will be
given the authorization to register and delete other users.
Step Description
1 Remove the two screws on the bottom of the face cover to reveal
the keypad.
2 Press ‘ADD Button’
3 The Green and Yellow lights will light simultaneously.
4 The primary master is to place his/her fingerprint on the scanning
platform to authorize additional users.
5 The Green Light will stay lit waiting for a PIN code for the new user.
6 Enter a 2 digit pin code twice. (for master 2 user 0202, for master 3
use 0303).
7 The Green and Yellow lights will light simultaneously.
8 Place the new Master’s fingerprint on the scanner to scan the first
template.
9 When the scanner light goes dark, remove your finger from the
scanner.
10 The Green and Yellow lights will light simultaneously.
11 Place the SAME fingerprint on the scanner to scan the second
template.
12 The system will beep when the second template is registered.
13 The FDS-100 will now compare the two templates registered and
save the Alternate Masters template to memory.
14 The Green light will blink three times to let you know that the
Primary Master is now registered.
15 You may now replace the face cover or register additional masters
or authorized users
▲ If the registration is accepted by the system, you will hear the beep
sound with the green LED blinking. If failed, the red LED will blink and the
system will beep four times rapidly. That means you need to repeat the
steps outlined above.
▲ Masters’ ID number must always be ‘01’, ‘02’ and ‘03’. For
programming purposes, these are entered as 0101, 0202, and 0303
Biometrics Direct – BioCert FS-100 Door Lock Page 10
Registering Additional Users
The presence and fingerprint authentication from any one of the masters
is required to execute the following procedures:
Step Description
1 Remove the two screws on the bottom of the face cover to reveal
the keypad.
2 Press ‘ADD Button’
3 The Green and Yellow lights will light simultaneously.
4 The primary master is to place his/her fingerprint on the scanning
platform to authorize additional users.
5 The Green Light will stay lit waiting for a PIN code for the new user.
6 Enter a 2 digit pin code twice. (10 through 99 – enter as 1010
through 9999).
7 The Green and Yellow lights will light simultaneously.
8 Place the new Users fingerprint on the scanner to scan the first
template.
9 When the scanner light goes dark, remove your finger from the
scanner.
10 The Green and Yellow lights will light simultaneously.
11 Place the SAME fingerprint on the scanner to scan the second
template.
12 The system will beep when the second template is registered.
13 The FDS-100 will now compare the two templates registered and
save the users’ template to memory.
14 The Green light will blink three times to let you know that the user is
now registered.
15 You may now replace the face cover or register additional masters
or authorized users
▲ If the registration is accepted by the system, you will hear the beep
sound with the green LED blinking. If failed, the red LED will blink and the
system will beep four times rapidly. That means you need to repeat the
steps outlined above.
▲ An “Authorized User’s” ID code must be a two digit number other
than the master’s ID code which are ‘01’ ‘02’ ‘03’. We recommend using
numbers 10-99 for Authorized Users. Example User 10 would be entered
1010 for programming purposes 11 would be 1111 and so on.
Biometrics Direct – BioCert FS-100 Door Lock Page 11
Deleting Fingerprints From The System
The presence and fingerprint authentication from any one of the masters
is required to execute the following procedures:
Step Description
1 Press the DEL button.
2 The RED lamp will light.
3 Press ANY Master fingerprint on the scanning platform to
authenticate deletion.
4 The system will now beep letting you know the deletion is
authorized and is awaiting the user information to be deleted.
5 Input the USER Number to be deleted twice (02-99 – input as
0202-9999)
6 The system will now beep and the green lamp will light letting you
know that the user / master you have selected is now deleted.
7 NOTE – The user or master being deleted from the system does
NOT need to be present to have their fingerprint deleted from the
system.
▲ If any of the deletion procedure was accepted by the system, you
will hear the beep sound with the green LED blinking. If failed, the red
LED will blink and the system will beep four times rapidly. That means you
need to repeat the steps above.
▲ You may delete master fingerprints using the same method as
above. To delete ALL fingerprints and the Primary Master, Master 0101
must be deleted and the Primary Master will have to authenticate his/her
own deletion from the database. – This will reset the FS-100 to factory
specifications with ANY finger being able to unlock the door. You must
then re-register a NEW Primary Master.
Biometrics Direct – BioCert FS-100 Door Lock Page 12
Unlocking and Entering Your Door
Illustrates the operation method when a registered user enters from
outside.
Step Description
1 Press the START button.
2 When the yellow LED blinks, you will hear the system beep once.
3 When the red scanning light flashes, place your registered finger
on the scanner for about 1~3 seconds.
4 If the fingerprint matches with the registered template, the door will
be unlocked and the green LED will blink and the system will beep.
Access is Granted.
5 If the fingerprint does not match with the previously registered
template, four beeping sounds will be heard and with the Red LED will
blink. Access is Denied.
- The lock stays in ‘open’ mode for 5 seconds and will be locked
automatically if it is not opened during this time.
- Turn the safety bolt on from inside, then no one may get access
either with fingerprints or PIN codes.
- Turn the safety bolt off and swing the indoor handle to open the
lock.
- If an unregistered person tries to open the door more than five
times, the system will get into five-minute interval. This is to prevent any
power drain caused by children’s mischief or any intentional abuse.
- Emergency
Under the condition that the FP system cannot work, you can uncover the
keypad cover and input the previously set PIN codes to open the lock. If
the interior battery supply doesn’t work normally, plug a 9V battery into the
exterior power socket underneath the keypad and input the correct PIN
codes to open the lock.
Biometrics Direct – BioCert FS-100 Door Lock Page 13
Setting PIN Codes Using the Keypad
Step Description
1 Remove the Keypad cover screws off in order to uncover the
keypad.
2 Press the ‘*’ button and then input a 0~9-digit PIN code within 8
seconds.
3 Press the ‘*’ button again and input the same number.
4 Press the ‘*’ button to finish.
- For example, if you will set the PIN code ‘123456’, the operation is
just like ‘*123456*123456*’
- If you will revising the code to ‘12345678’, the operation will be
‘123456*12345678*12345678*’
- The system is initially given the primary PIN code 1234 ‘#’,
press the 1234 ‘#’ buttons in sequence and the door will open.
- If you will use the PIN code to open the door, enter the code within
8 seconds, then press the ‘#’ button to finish.
- If the PIN code has been entered correctly, a single beep will be
heard, and the door will open.
▲ If the above procedure was accepted by the system, you will hear
the beep sound with the green LED blinking. If failed, the red LED will
blink and the system will beep four times rapidly. That means you need to
repeat the steps above.
Biometrics Direct – BioCert FS-100 Door Lock Page 14
Trouble Shooting
Problem - Resolution
A fingerprint is not recognized well -
· Check whether any moisture or stains exist on the fingertip. If either of
these situations exist, wipe dry the fingertip and try again.
· Recognition capability decreases when the fingertip is too dry. In this
case, breathe on the fingertip and try again.
· Try to have the finger smoothly pressed against the scanner.
· Be careful not to move the finger as the fingerprint verification takes
place.
Beep sounds after using the door lock -
· Low Voltage warning. – This means that the voltage on the installed
batteries is dangerously low.
· Replace the batteries. If this situation persists, please contact us for
technical support.
Handle is too stiff to move -
· Bolts inside of the system should be tightened for better “fit” of the
system.
· This may be caused by mishandled installation, frequent impact, or
deformation of the shape.
· If this problem persists, contact us for technical support.
All LEDs of the system flashing, and it operates abnormally. -
· This is alerting you that all users have been cleared and you need to
register the Primary Master fingerprint.
· If this problem persists after registering the Primary Master fingerprint,
please contact us for technical support.
The system cannot start after pressing the Start button
· Low Voltage – This means that the voltage on the installed batteries is
dangerously low.
· Replace the batteries. If this situation persists, please contact us for
technical support.
Biometrics Direct – BioCert FS-100 Door Lock Page 15
Fingerprint Authorization Operates Intermittently
· Verify you are using the correct fingerprint.
· Your fingerprint may not be suitable for authorization. Please register
a different fingerprint.
· Replace the batteries. If this situation persists, please contact us for
technical support.
FP Undeletable
· Verify you are using the correct “Master” fingerprint to authorize
deletion.
· If this situation persists, please contact us for technical support.
Registration failure
· Verify you are using the correct “Master” fingerprint to authorize
registration.
· Make sure your fingerprint is placed correctly on the scanner.
· Low Voltage – Replace system batteries
· If this situation persists, please contact us for technical support.
FP cannot be matched when the system starts
· Verify you are using the correct fingerprint to authorize entry.
· Make sure your fingerprint is placed correctly on the scanner.
· Low Voltage – Replace system batteries
· If this situation persists, please contact us for technical support.
The handle cannot be released normally
· Low Voltage – May not allow the system to release to the correct
position – Replace system batteries
· If this situation persists, please contact us for technical support.
Caution - Please restrict the masters only to the persons who are actually
responsible for the access control. Do not to register any installation team
members or people who don’t need to be registered as a master.
Biometrics Direct – BioCert FS-100 Door Lock Page 16
Biometrics Direct – BioCert FS-100 Door Lock Page 17
Warranty Statement – Biometrics Direct BioCert™ FS-100 Door Lock
The FS-100 Door Lock distributed by Artemis Solutions Group, LLC, DBA Biometrics Direct is warranted
against material defects and faulty workmanship. Any parts that are listed below, which from date of
shipment be proven to have been defective in these respects when delivered, will be replaced by the
company. Shipping charges for the defective components to our facility are paid by the customer. Return
shipping costs of the replacement components are paid by us.
Strike: The Strike is warranted for one year on parts ONLY.
Key Fob Remote: The Key Fob is warranted for one year - Replacement.
Door Lock: The FS-100 Door Lock is warranted for one year parts – Replacement. Costs associated with
the removal and installation of the door lock, mortise and/or strike plate are NOT covered.
Battery: Batteries are not covered under this warranty.
No claims will be allowed for material damaged by the customer or damaged in transit. Expenses incurred in
connection with claims for which the company is not liable. All freight, handling and expense incurred in
getting the product to and from the service center is to be paid by the customer prior to any warranty work
being done. No return will be accepted without an Authorized letter. If safety labels, serial numbers or
markings are removed or tampered with, the warranty is void immediately.
THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR
IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABLE QUALITY,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE , OR THOSE ARISING BY LAW,
STATUE, USAGE OR TRADE OR COURSE OF DEALING, AND IN LIEU OF ANY OTHER OBLIGATIONS
OR LIABILITIES ON THE PART OF BIOMETRICS DIRECT. ACCORDINGLY, BIOMETRICS DIRECT
ASSUMES NO LIABILITY OR OBLIGATION WHATSOEVER IN THE SALE OF THIS PRODUCT
INCLUDING ANY LIABILITY FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES TO YOU OR
ANY OTHER PERSON, PROPERTY OR ENTITY RESULTING FROM THE USE OR POSSESSION
THEREOF. OUR MAXIMUM AGGREGATE LIABILITY TO YOU SHALL NOT EXCEED THE AMOUNT PAID
BY YOU FOR THE PRODUCT. THE LIMITATIONS IN THIS SECTION SHALL APPLY WHETHER OR NOT
THE ALLEGED BREACH OR DEFAULT IS A BREACH OF A FUNDAMENTAL CONDITION OR TERM, OR
A FUNDAMENTAL BREACH. WARRANTIES IMPLIED BY LAW ARE LIMITED IN DURATION TO THE
ONE YEAR PERIOD DESCRIBED ABOVE. ANY DISPUTE UNDER THE TERMS OF THIS WARRANTY
SHALL BE DECIDED UNDER THE LAW WITHIN THE STATE OF FLORIDA (US).
Biometrics Direct – BioCert FS-100 Door Lock Page 18
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.