BioEnergiser ElectroFlex User Manual

USERMANUAL
Pleasereadbeforeuse
Acomfortableand relaxingmicro currentstimulation treatment designedtohelp alleviatepainand sorenessassociated withavarietyof conditions
IMPORTANT SAFETY INFORMATION
1. Please read these instructions thoroughly before use.
2. Please check that you have all of the component parts as detailed in this user manual.
3. Take all parts out of theplastic bags and examine them to familiarise yourself with the components.
PRODUCT SAFETY
ElectroFlex is an extremely safe and simple to use device de­signed to assist with increased circulation and blood flow. The benefits of this type of treatment are wide spread and well docu­mented. Increased blood circulation helps to optimise health. ElectroFlex is not sold as a medical device. This home use unit is designed for general physical conditioning. No medical claims are implied or warranted.
1. Long term effects of chronic electrical stimulation are unknown so please do not ‘over-use’ you r ElectroFlex. A maximum of one treatment per day is recommended.
2. DO NOT USE
If you have a pace maker fitted. If you have a cardiac condition. If you suffer from epilepsy. If you are under 10 years of age. After recent surgical procedures. If you have sensory nerve damage. If you suffer with Multiple Sclerosis. If you suffer with extreme varicose veins. If you are pregnant or immediately after child birth.
DO NOT PUT YOU HANDS ON THE FOOT TREATMENT AREA WHILST THE ELECTROFLEX IS OPERATIONAL. If in doubt please consult your medical practitioner.
WHAT IS FOOT REFLEXOLOGY
Foot Reflexology is a "pressure ther apy" and involves applying focused pressure to certain known reflex points located in th e foot that correspond to certain other areas in the body so as to cure or prevent disease. It is based on the premise that our nerve zones or reflex points go from the bottom of our feet to the top of our head, encompassing all vital organs on the way. A trained reflexologist co ul d p ut pressu re o n different reflex points or energy lines on the sole and side of the feet to deter­mine the cause of illness.
The Benefits of Foot Reflexology:
1. Reduces the level of stress.
2. Increases blood circulation.
3. Rejuvenates tired and aching feet and legs.
4. Assists the body in returning to a state of balance.
5. Works with all other modalities, traditional and conventional.
6. Works with the whole body affecting mind, body, and spirit.
7. Beneficial for post operative recovery and pain reduction.
8. Adjunct to mental health care (e.g. depression, anxiety, post
traumatic stress disorder).
MACHINE OVERVIEW/PART NAMES
A B C
D E F
A Electrode silicone area for foot treatment B Far infra red light C LCD display screen D Sole massage ro ller E Far infra red light F Carrying handle
CONTROL PANEL
A
B
F
C
E
D
G
Band 1 intensity (corresponds to left foot)
Band 2
intensity
(corresponds
to right foot)
Timer
Program
indicator
A intensity UP for band 1 (left side) 1 to 40 B intensity DOWN for band 1 (left side) 1 to 40 C intensity UP for band 2 (right si de) 1 t o 40 D intensity DOWN for band 2 (right side) 1 to 40 E program UP choose one of the 10 massage options F program DOWN choose one of the 10 massage options G ON/OFF SWITCH. HOLD DOWN FOR 3 SECONDS TO OPERATE.
KNOW YOUR MACHINE
The BioEnergiser Electroflex Circulation Massager is based on age old Chinese Reflexology the EMS (Micro Current Stimula­tion) stimulates the pressure points on the soles of your feet providing a relaxed treatment that reflexologist’s believe can benefit the human bodies organ’s and offer relief from pain.
With a large backlit LCD screen the settings are easy to operate.
Features include: Far Infrared massage function and manual foot massager. 10 preset programs with 40 levels per program and 2 channels for various muscle types. Includes 4 gel pads which allow the user to enjoy the EMS treatment to relieve muscular pain on other parts of the body. LED control panel. Ergonomic and easy to use. Integrated carrying handle.
FOOT ELECTROTHERAPY MASSAGE: We will examine the operation in more detail later in your instructions but the principle is relatively easy to understand. There are two separate controls/channels, one for each foot. The reason for this is that you can adjust the intensity for the left and right foot individu­ally. Place your feet on the electrode areas, turn on ElectroFlex with the central on/off switch (hold down for 3 seconds to acti­vate), choose one of the 10 different treatment programmes and finally start to increase the intensity for each foot. There are 40 different levels. When you start to feel the mild electro-therapy will depend on your own nerve sensitivity. Certain individuals will feel nothing until the intensity is up at a high level, others will feel the stimulation at relatively low levels. This is com­pletely normal.
BODY TONING: if you choose to tone muscle groups or target pain in other areas of your body the ElectroFlex comes with four gel pads. These can be used to tone arms, hips, thighs, abs or buttocks or target neck muscle or back pain.
..........
..........
˜˜˜ ˜˜˜ ˜˜˜
˜˜˜˜˜˜˜˜˜˜
˜˜˜˜˜˜˜˜˜˜
˜˜˜˜˜˜˜˜˜˜
PROGRAMME DESCRIPTION
There are 10 different programme settings which give the user different treatment patters. You can use each of the treatment selections with the foot massage function OR through the pads.
PROGRAMME PATTERN
ONE
tapping massage
TWO
prickly massage
THREE
combined massage
FOUR
pulsed prickly massage
FIVE
tapping massage (2)
SIX
fast tapping massage
SEVERN
fast tapping/prickly massage
EIGHT
V.fast tapping/prickly massage
NINE
pulse prickly massage (2)
TEN
fast tapping with pulse massage
___ __ __ _ _ _ _ _ ___ __ __ _ _ _ _ _
˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜
__ __ __ __ __ __
˜˜˜ ˜˜˜ ˜˜˜˜˜˜˜˜˜˜˜ ˜˜˜ ˜˜˜ ˜˜˜˜˜˜˜˜˜˜˜
__ __ __ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _
......................... .....................
__ __ __ _ _ _ __ __ __ _ _ _
˜˜˜˜˜˜˜˜˜˜
˜˜˜ ˜˜˜ ˜˜˜ ˜˜˜˜˜˜˜˜˜˜ ˜ ˜ ˜ ˜ ˜˜˜˜˜˜˜˜˜˜
HOW TO OPERATE
1. Place your feet onto ElectroFlex
2. Press (and hold down for 3 seconds) the on/off button, the
LCD screen will light up in blue.
3. Select the program you wish to use there are 10 different
programs which are indicated on the LCD display.
4. The intensity automatically comes on at the lowest level.
The intensity level is adjustable between 0 and 40 .
5. Gently increase intensity setting by pushing the button
︿.
Decrease intensity setting by pushing the button of
”. (Left
button for “Band 1”, right button for “Band 2”.) Left and right intensity levels are independently adjustable. LEFT being BAND 1 and RIGHT being BAND 2.
6. You can adjust the program anytime. Once re-adjusted the
intensity will return to ‘0’. So you will have to increase the intensity to the desired level.
7. To terminate the massage period, user can turn off the unit
anytime by pressing the on/o f f but t o n fo r 3 secon ds.
The unit has an auto timer, it will start to count down from 25 minutes of massage and switch off automatically.
USING THE GEL PADS
Connect the output wire to th e Electrode Gel Pads. Connect the other end of the output wire to the output jack of the Electro­Flex. Remove the protecting film from the adhesive pads. Attach the Electrode Gel Pads to the skin. Press the on/off but­ton for 3 seconds to turn on the unit and adjust the stimulating mode and output intensity to the desired level. (The display will show the mode and the level that you selected and start to coun t down).
CARE OF YOUR GEL PADS
Never stick two adhesive pads to each other. Keep the adhesive gel pads clean, never expose them to high tem­perature or direct sunshine. If the electrode gel pads are insuffi­ciently adhesive or dirty, wipe with a wet cloth or change for new ones, replacement parts will be available directly from Bio­Energiser or your distributor.
Don not clean the electrode gel pads with any chemical.
ALWAYS try and protect the gel pads store the gel pads on the gel pad protector when not in use, as in the illustration.
foot massage back massage upper arm massage tummymassager
thigh massage shoulder massage back waist massage forearm massager
CONNECT WITH SUPPLIED POWER ADAPTER
Plug the DC plug of the power supply into the socket on the side of the ElectroFlex. Plug in the power adaptor to a suitable wall socket. (Make sure that the input voltage of the wall socket is suitable for the sup­plied adaptor.
INSTALLING THE BATTERIES
If you want to use the ElectroFlex with battery power instead of the supplied main adapter, the battery compartment is located On the under side of the unit.
Remove the battery cover from the unit. Insert three new 1.5V size C batteries with the + and - marks correctly aligned.
Note on batteries: Do not mix different types of batteries or an old battery with a new one. To prevent the risk of leakage of explosions, never recharge the batteries, apply heat or take them apart.
When not using batteries, remove them to prevent battery drain. If liquid leaks from the batteries, throw them away. Thoroughly clean the battery compartment with a dry cloth.
CHANGE THE SOLE MASSAGE ROLLER
The sole massage rollers are interchangeable.
The roller is fixed into position between the two locking loca­tors. These push in to the main body of the ElectroFlex to hold the sole massage roller firmly in place.
To remove the locking locators you will need to squeeze the locator on the outside face this will push the locking locator out of it’s fixed position and allow you to remove and change the roller
TECHNICAL SPECIFICATION
Battery power supply: 3x C size batteries Or AC/DC adaptor: Model No. R-G35179DT Input : 230v ~ 50Hz or 120v ~50Hz Output: 4.5V d.c. 100mA
Product Name Model No Power Input Power Output Power Consumption
ELECTROFLEX BE109 3XC size battery or 230v ~ 50Hz
4.5V d.c. 100mA
0.45W
PO Box 4359 Kidderminster DY10 4WU
Tel: +44(0)1562 752700
info@bioenergiser.com
www.bioenergiser.com