Billi 913000RBR, 913000RCH, 913000RMB, 913000RMW, 913000RUB Installation Guide

...
Installation guide Billi B-3000
Installation requirements.
Components for B-3000
Before commencing installation, ensure you have identified the following.
1. Chilled Water Module
2. Installation Requirements
4. Warranty
Water Supply
A single cold water supply is required.
Supply Pressure: 200 – 1000 Kpa Supply Temperature: 5°C – 30°C
Do not install with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Power Requirements
A single 10 amp standard power outlet is required. Chiller module is supplied with 1 metre of flex cord and plug.
Power Outlet
Cupboard Dimensions: 220mm Minimum Width 365mm Minimum Depth
Stop Tap (Installed by Plumber) Max 450mm from Unit
800mm
Tube Length
Supplied
Diagram 1
Drainage
A drainage point, such as a dishwasher nipple or a tundish, is required.
233mm
37mm
113mm
bench thickness 1mm-37mm
Diagram 2
2