Installation requirements.
Proud & Flush Mount
Components included
Before commencing installation, ensure
you have identified the following pieces:
1. Font tray
2. Font cover plate set 1 set (3 piece)
3. Sealing Gaskets x 3
4 Drain adapter
5. O-ring
6. M5 x 40mm screw
7. Elbow 3/4”
8. Bush
9. Hose adaptor
10. M6 x 45mm hex bolt x 4
11. M6 Flange nuts x 4
12. Font washer
13. Font mounting bracket x 4
Determine unit location
Plan the installation. Dispenser tube lengths,
benchtop and cupboard restraints and drainage
requirements must be considered when
determining location. Use template enclosed
for drilling and cut-out details. Refer also to
appliance installation requirements supplied
with Drinking Water System.
Font tray
O-ring
Drain adapter
M5 x 45 screw
Drainage location
Careful design and installation is essential
to provide satisfactory drainage performance
and to prevent later blockages. The Billi Font
is designed to be able to be connected to
a dishwasher nipple using either flexile or
rigid tubing or copper tubing. Where a
horizontal run is needed, we recommend
20mm or 25mm copper tubing be used.
An adapter bush is supplied for use where
a standard 40mm trap and drain is installed.
IMPORTANT
If drain is to be connected to a dishwasher
nipple, ensure hole through nipple is drilled
to at least ø12.7mm (1/2”) and de-burred,
to allow adequate flow.
Drain must be installed with a continual
fall along the entire length of the tube.
The Billi Fixture is to be installed by
a licensed tradesperson in accordance
with as 3500.4 Or AS/NZ 3500.4.2
And in compliance with applicable
state regulatory requirements.
Diagram 1
2
Page 3
Installation procedure.
Proud Mount
1. Marking and Drilling Holes
a. Cut out hole in benchtop using measurement shown in Diagram 7a on
the following page.
2. Fitting Drain Adapter
a. Fit O-ring to Drain adapter.
b. Fit Drain adapter to tray. Tighten M5
screw, Note: Do NOT over-tighten
the screw.
c. Drain tube and elbow fitting are to
face dispenser mount hole – refer to
diagram 1 on previous page.
3. Fitting Billi Font to Benchtop
a. Install the sealing gasket around the edge
of the font tray. Refer to Diagram 2.
b. Lower the Font tray into the cut out and
insert 4 x M6 bolts, one in each corner.
c. Fit the clips and M6 Flange nuts to all 4
bolts – refer to Diagram 3.
e. Tighten nuts until rim sits flat on
benchtop. Do NOT over-tighten nuts.
BenchFont tray
Seal between
Font and Benchtop
Diagram 2
BenchFont tray
4. Fit front and rear cover plates
a. Remove protective film from cover
plate set.
b. Remove bottom gasket covers and insert
into gasket grooves.
c. Remove gasket cover and insert cover
into font tray.
d. Ensure holes in rear cover plate align with
the holes in the font tray.
e. Apply pressure around edge of plate(s)
to ensure proper gasket seal.
5. Install the tap – refer to diagram 4.
a. Feed the dispenser tube and tap base into
hole in the rear of the font.
b. Feed lock mechanism components onto
the end of the dispenser tube in the
following order:
i. Washer
ii. Locking bush
iii. Locking nut .
c. Slide components into position and
tighten the locking nut.
Note: Do NOT over tighten.
6. Connect Tubing to Underbench Module
a. Connect dispenser tubing to underbench
module as per installation instructions
supplied with your unit.
Clip
Bench
M6
Bolt
Diagram 3
Plate
Gasket
Font tray
Washer
Locking Bush
Locking Nut
Diagram 4
7. Connect Drainage
a. Connect drainage tubing with reference
to Drainage Requirement instructions
on previous page. Drainage tube must
be installed with a continual fall along
the entire length of the tube and must be
adequately clipped and supported.
291mm
191mm
Diagram 5
3
Page 4
Installation procedure.
25mm
Proud Mount
TOP VIEW
Hole Cut-Out Dimensions
– See Template for actual size,
Before using check dimensions
are accurate.
Bench
172mm
FRONT
Not to scale
SIDE
272mm
EXPLODED DIAGRAM
Font
Bench
272.0mm
191.0mm
>
Diagram 7bDiagram 7a
4
Page 5
Installation procedure.
Gasket
Bench
Plate
Font tray
Washer
Locking Bush
Locking Nut
291mm
191mm
Flush Mount
1. Marking and Drilling Holes
a. Cut out hole in bench top according to
Diagram 7a on page 6. Use appropriate
router bits to give R5.0 edges.
2. Apply thick coat of moisture primer to all
cut surfaces
3. Fitting Drain Adapter
a. Fit O-ring to Drain adapter.
b. Fit Drain adapter to tray. Insert and tighten
M5 screw, Note: Do NOT over-tighten
the screw.
c. Drain tube and elbow fitting are to
face dispenser mount hole –refer to
diagram 1 on page 2.
4. Fitting Billi Font to Benchtop
a. Install the sealing gasket around the edge
of the font tray. Refer to Diagram 2.
b. Lower the Font tray into the cut out and
insert 4 x M6 bolts, one in each corner.
c. Fit the clips and M6 Flange nuts to all 4
bolts – refer to Diagram 3.
e. Tighten nuts until rim sits flat on
benchtop. Do NOT over-tighten nuts.
5. Fit front and rear cover plates
a. Remove protective film from cover
plate set.
b. Remove bottom gasket covers and insert
into gasket grooves.
c. Remove gasket cover and insert cover
into font tray.
d. Ensure holes in rear cover plate align with
the holes in the font tray.
e. Apply pressure around edge of plate(s)
to ensure proper gasket seal.
BenchFont tray
Seal between
Font and Benchtop
Diagram 2
BenchFont tray
M6
Bolt
Clip
Diagram 3
6. Install the tap – refer to diagram 4.
a. Feed the dispenser tube and tap base into
hole in the rear of the font.
b. Feed lock mechanism components onto
the end of the dispenser tube in the
following order:
i. Washer
ii. Locking bush
iii. Locking nut .
c. Slide components into position and
tighten the locking nut.
Note: Do NOT over tighten.
7. Connect Tubing to Underbench Module
a. Connect dispenser tubing to underbench
module as per installation instructions
supplied with your unit.
8. Connect Drainage
a. Connect drainage tubing with reference
to Drainage Requirement instructions
on previous page. Drainage tube must
be installed with a continual fall along
the entire length of the tube and must be
adequately clipped and supported.
Diagram 4
Diagram 5
5
Page 6
Installation procedure.
Flush Mount
TOP VIEW
191.0mm
8.5mm
Font cut out:
174mm (wide) x 274mm (long)
ebate cut: 5.5mm (deep)
R
191mm (wide) x 291mm (long)
Corner Radius: 5mm
Tolerance: +/- 0.2mm
174.0mm
8.5mm
8.5mm
Hole Cut-Out Dimensions
– See Template for actual size,
Before using check dimensions
are accurate.
SIDE
Bench
FRONT
Not to scale
274.0mm
8.5mm
Diagram 7a
291.0mm
EXPLODED DIAGRAM
Bench
25mm
>
Font
Diagram 7b
6
Page 7
Page 8
If any problems or difficulties arise contact Billi Australia Pty Ltd: Phone 1800 812 321 (Free call).
To validate your warranty refer to the warranty card or validate online at www.billi.com.au
For information on our filtration and service contracts please contact Billi Customer Service on
1800 812 321 or service@billi.com.au.
As Billi Australia Pty Ltd has a policy of
continual improvement, all details are
subject to change without notice. All
goods are sold subject to our published
terms and conditions. Billi is a registered
trademark. 0618
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.