IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance with
AS/NZS 3500.1 and AS/NZ 3500.2 and in compliance with applicable state regulatory requirements.
For correct operation of this appliance, it is essential to observe the manufacturer’s instructions.
Water Supply
The B-1000 must only be connected to a
cold water supply. A 15mm stop tap (not
supplied) is to be installed in an easily
accessible position within 450mm from the
B-1000 water inlet.
1. Determine Component Location
Determine the location of each of
the components, taking into account
the tube lengths and space available
(see Diagram 1).
2. Plan Dispense Position
Determine the position of dispenser
mounting hole in sinktop or benchtop.
Hole size required is 22mm.
3. Install Components
a) Connect the Pressure Limiting Valve
(with blue mini-tap ) to the mains
water supply.
b) Connect one end of the white hose
provided to the blue mini-tap and connect
the other end of the white hose to the
Filter Module fitting labeled “IN”.
c) Mount the Filter Module in an easily
accessible position, preferably close
to the front of the cupboard to allow
for filter changes.
d) After establishing where the dispenser
can be installed (within the limits of
the hose length from the dispenser to
Filter Module.) punch a 22mm hole for
mounting the dispenser.
e) Mount the dispenser by first passing
the blue hose through the hole and then
fitting the locking bush and lock nut to the
threaded mounting shaft (see Diagram 2).
Tighten the locknut. Reconnect blue hose
to the out fitting.
Commissioning Unit
Turn on the mains tap and then turn
on the blue mini-tap and check for leaks.
If no leaks are detected, rotate the lever
on the dispenser until a good stream of
water is present.
Note: There may be air bubbles in the water
at first as the water filter is dry.
Allow 2-3 minutes of continuous run to
ensure all air bubbles have been flushed
from the system.
Hoses deleted
for clarity
15mm stop tap
(installed by plumber)
22mm hole
required
Diagram 1
1/4 filter water outlet
Locking bush
1/4 filter water inlet
Locking nut
Diagram 2
15mm stop tap
PLV
Diagram 3
For service and support contact Billi on 1800 812 321 or email service@billi.com.au
Billi Australia Pty Ltd
42 Lucknow Cr
escent, Thomastown
Victoria 3074 Australia
Designed and manufactured in Australia.
As Billi Australia Pty Ltd has a policy of
continual improvement, all details are
Telephone +61 3 9469 0400
Facsimile +61 3 9469 0499
subject to change without notice. All
goods are sold subject to our published
terms and conditions. Billi is a registered
www.billi.com.au
trademark. 0618