Contents
Warnings & Important information ........2
General Maintenance.....................3
Features and Modes......................4
Tap Options & Operation
XL Tap.................................5
XT Tap.................................5
XR Tap ................................5
Set up instructions
XL Tap...............................6-7
XT Tap...............................6-7
XR Tap ..............................6-7
Filtration information.....................8
Changing the filter .......................9
Quadra Plus ............................10
Service Support ........................10
Warnings & Important information
– For continued safety of this appliance it
must be installed, operated and maintained
in accordance with the manufacturer's
instructions.
– Your appliance should be installed
by a suitably qualified tradesperson.
– For correct operation of this appliance
it is essential to observe the instructions
as outlined in this booklet.
– Do not use this appliance with water that
is microbiologically unsafe or with water
of unknown quality without adequate
disinfection before or after the system.
Systems certified for cyst reduction may
be used on disinfected water that may
contain filterable cysts.
– Filter replacement must be performed
at intervals of not more than 12 months.
– Use this appliance only as directed
in these instructions and only for its
designed purpose.
– This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the
appliance by a person responsible
for their safety.
– This appliance is not suitable in an
area where a water jet could be used.
– Children should be supervised to ensure
that they do not play with the appliance.
– DANGER: The operation of the thermal
cut-out indicates a possibly dangerous
situation. Do not reset the thermal cut-out
until the water heater has been serviced
by a suitably qualified person.
– WARNING: Do not connect any restrictor
or pressure relief device to the vent pipe
of this water heater if installed.
2
User guide
Billi Quadra & Quadra Plus – XL, XT, XR.
– If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid creation of a hazard.
– Billi hose sets as supplied with the
appliance are to be used. Old or other
manufacturer’s hose sets should not
be re-used.
– If the appliance is located where the
ambient air temperature could fall below
4°C when the heater is not in use, do not
turn o the power supply to the appliance.
This safeguard does not oer the same
protection to the connecting pipework
and fittings.
– The ambient temperatures this unit
should operate within are 5°C to 30°C.
– Turn o power to unit, by unplugging the
power cord from the power point, if water
supply is turned o
Caution and safety
Boiling water is dangerous and can
cause severe burns, particularly with
young children. Boiling water must always
be handled with caution. Use this appliance
only as directed in these instructions and
only for the purpose for which it has been
designed. Your Billi Quadra is designed to be
safe and practical. In an environment with
young children, it is recommended that the
boiling water safety switch is activated.
The following safety features have been
included:
– Ergonomic levers
– Levers/touch activations located
safely above water outlet.
– Smooth electronically controlled boiling
water flow rate. Flow is briefly reduced as
water first enters cup to prevent splashing.
– Dispenser remains cool to touch.
– Childproof safety switch.
– Boiling water Safety Isolation mode.
General Maintenance
Your Billi Quadra has been designed to
require minimal maintenance other than
replacement of filter cartridges. During each
filter change, check all water connection
fittings for signs of leakage. Check all tubing
for any signs of damage. Check the cupboard
area around the base of unit for any signs
of moisture. For air cooled units, ensure
side vents of the under bench module are
kept clear and airflow is not obstructed.
Restricted airflow will cause inecient
operation of the refrigeration system.
—Cleaning the dispenser
Your Billi Quadra Dispenser is fabricated
from solid zinc casting material with tough
protective chrome plating. Proper care of the
Billi Electronic dispenser crucial; Avoid using
abrasive cleaners. Wipe clean using a damp
cloth. Use of a non-solvent, non-smearing
cleaner such as Windex is recommended.
Do not pour water over dispenser.
Cupboard ventilation requirements
Your Billi Quadra underbench module
requires no cupboard ventilation but
requires air space around the unit of 10mm.
Care should be taken when using the cupboard
space, to avoid stretching or damaging plastic
pipe work. Check fittings and tubing at each
filter change for signs of damage or leakage.
Always ensure access to power switch and
water supply tap is not restricted.
3
User guide
Billi Quadra & Quadra Plus – XL, XT, XR.
Features and Modes
XL
Your Quadra dispenser is simply operated
with position-sensitive levers. The Red dot
on the left indicates hot water and the blue
on the right indicates cold. Hot and cold
levers can either be lifted or depressed.
When lifted, the levers will latch for continuous
delivery until released with a light press.
The Quadra will not dispense hot and cold
water simultaneously. Water will not flow
if both levers are pressed together.
XT, XR
The XT and XR dispenser is operated with
capacitive touch buttons. Red and blue buttons
indicate the boiling and chilled water.
Red and blue buttons can be pressed and
held for momentary dispensing or double
tapped for continuous flow. Water will not
flow if both buttons are held together.
Dispenser swivel
The Quadra dispenser incorporates a swivel
function, allowing the dispenser to be swung
out of the way if more sink space is required.
A central position stop provides positive
location during normal usage.
Safety timeout
Your Billi Quadra incorporates a water delivery
Safety Timeout to prevent an uncontrolled flow
of water. Water flow stops automatically after
a set time interval. Flow can be started again
by releasing and pressing the dispenser lever
or button.
Boiling water timeout – 10 secs;
Chilled water – 1 minute.
Water delivery temperatures
The boiling and chilled water temperatures
can be adjusted to suit individual preferences.
Hot water temperature range: 80°C – 98.9°C
Cold water temperature range: 6°C – 20°C
Time switch
Your Billi Quadra incorporates an energy
saving time switch. This function allows the
Quadra to automatically turn ON and OFF at
selected times. Individual days can be set to
be active or non-active. The green lightning
bolt indicates that the time switch is set.
Refer to Setting Instructions, page 6.
Standby mode
An energy saving Standby mode can be
selected to activate after a period of non-use.
Once activated, the boiling water temperature
can drop to 80°C and the chilled water
temperature can rise to 15°C. A touch of
either dispenser lever or button cancels the
standby and the Quadra resumes its normal
operating mode to deliver boiling or chilled
water. The time needed to elapse before the
Quadra enters this mode can be varied. During
Standby mode, the green moon and stars icon
will be illuminated. Refer to Options, page 7.
Childproof safety switch
Your Billi Quadra is fitted with a childproof
safety lock-out feature to protect against
accidental dispensing of boiling water
and the risk of burns. Please refer to
page 7 to set up.
4