Bien Air S001, STS 890, SF 811 Instruction Manual

S001
0120
SF 811 STS 890
ENG Instruction
REF 2100024-ENG/06.08
English
Fully Swiss-manufactured devices.
Typ S001
pneumatic module, tabletop model.
SF 811
pneumatic module, model for fixed installation, to be mounted upright.
STS 890
pneumatic module with water reservoir.
These modules are equipped with a pedal, a pres­sure gauge with pressure relief device and a turbi­ne support.
Planned use
Product intended for professional use only.These modules are designed for laboratories and for prosthetic and ceramic work.
Technical data and assembly
3. Foot pedal operation
The drive air is activated by pressing the foot pedal anywhere on its surface. To activate the spray, press the foot pedal on the area indicated. The angle ot the spray is approx 100°.
4.Manometer-pressure regulator with filter
The reservoir of this filter must be cleaned regular­ly by opening the plug at the bottom of the reser­voir. Drain by pressing the bottom plug.
Maintenance
Only use maintenance products and components from Bien-Air.The use of other products and com­ponents can void the guarantee.
Overhaul
Never disassemble the device. For all modifications and repairs, we recommend that you contact your regular supplier or Bien-Air direct. Bien-Air asks the user to have its dynamic instruments checked or inspected at least once a year thereafter.
Never immerse in disinfectant solutions. Not suitable for ultrasonic bath.
Recommendations
It is essential to use dry, purified compressed air in order to ensure the long working life of the device. Maintain the quality of the air and the water by re­gular maintenance of the compressor and the fil­tration systems. The use of unfiltered hard water will lead to early blockage of the tubes, connectors and spray cones.
After a period of prolonged use, the device must be cleaned and serviced according to these instruc­tions.
Rest the device on a suitable support to avoid risks of infection for yourself, the patient or third parties.
Guarantee
Terms of guarantee
Bien-Air grants the operator a guarantee covering all functional defects, material or production faults. The device is covered by this guarantee for 12 months from the date of invoicing.
Bien-Air also offers a 24-month guarantee for the glass-bar light conductors.
In the event of justified claims, Bien-Air or its aut­horised representative will fulfil the company’s ob­ligations under this guarantee by repairing or re­placing the product free of charge. Any other claims, of whatever nature, in particular in the form of a claim for damages and interest, are excluded.
S001
Bien-Air shall not be held responsible for damage or injury and the consequences thereof, resulting from:
• excessive wear and tear
• improper use
• non-observance of the instructions for installa­tion, operation and maintenance
• unusual chemical, electrical or electrolytic influences
• poor connections, whether of the air, water or electricity supply.
The guarantee does not cover flexible “fibre optic” type conductors, or any parts made of synthetic materials.
The guarantee shall become null and void if the damage and its consequences are due to improper manipulation of the product, or modifications to the product carried out by persons not authorised by Bien-Air.
Claims under the terms of the guarantee will be considered only on presentation, together with the product, of the invoice or the consignment note, on which the date of purchase, the product reference and the Serial No. should be clearly indicated.
S001 assembly SF811 mounting STS 890
Classification
Conforms to machinery directive 89/392/EC.
Dimensions
S001: 110 x 135 x 162 mm SF 811: 86 x 75 x 165 mm STS 890: 200 x 190 x 100 mm
Weight
S001: 1,250 g SF 811: 300 g STS 890: 4,400 g
Air pressure at inlet
S001 & SF 811 & STS 890: min. 500 kPa and max. 800 kPa
Air consumption output
S001 & SF 811 & STS 890: 32 normliter/min
Air pressure output
S001 & SF 811: 250 kPa - 300 kPa
The unit is delivered with a pre-adjusted of 300 kPa.
Do not use the turbine at above the required air pressure (see instuction REF 2100038).
STS 890
1. Spray regulator
The desired water quantity is adjusted by the green control knob and the air supply by the blue control knob.
2. Refilling the water reservoir
Unscrew the cap slowly to allow pressure to be re­leased. Refill water tank with distilled water only, by using the enclosed measure. Replace and close the cap. The pressure in the reser automatically re-set.
fig. 1 fig. 2 fig. 3
voir is then
Environment
Temperature between -40°C (-40°F) and 70°C (158°F), relative humidity between 10% and 100%, atmospheric pressure 50 kPa to 106 kPa (7.3 to 15.3 psi).
Information
The technical specifications, illustrations and di­mensions contained in these instructions are given only as a guide. They may not be the subject of any claim. The manufacturer reserves the right to make technical improvements to its equipment, without amending these instructions. The French original of this text conforms to the legal stan­dards. For all additional information, please contact Bien-Air at the address indicated on the back cover.
General information
The device must be used by a competent person in accordance with the current legal provisions con­cerning industrial safety, health and accident pre­vention regulations, and these working instruc­tions. In accordance with these requirements, the operators:
• must only use operating devices that are in per­fect working order; in the event of irregular fun­ctioning, excessive vibration, abnormal heating or other signs indicating malfunction of the device, the work must be stopped immediately; in this case, contact a repair centre that is approved by Bien-Air;
• must ensure that the device is used only for the purpose for which it is intended, must protect themselves, their patients and third parties from any danger, and must avoid contamination through the use of the product.
The device is not intended for medical treatment; any use other than that for which this product is intended is not allowed and may proved to be dan­gerous. The device meets all the current European legal requirements (in accordance with machi­nery directive 89/392/EC).
fig. 1
SF 811
fig. 2
STS 890
fig. 3
internal Ø 1/8" (3,17mm)
Air in 5 - 8 bars 72 - 116 psi
internal Ø 1/8" (3,17mm)
Air out
2.5 - 3 bars 35 - 42 psi
REF 2100024-ENG/06.08 1/2
Set supplied
0120
REF 1700126-001 Set comprising
REF 1600161-001
REF 1600318-001
REF 1600312-001
REF 1700092-001 Set comprising
REF 1600388-001
REF 1600389-001
REF 1600163-001
REF 1200022-001
REF 1600390-001
Optional accessories
S001 + SF 811
REF 1600312-001 REF 1200022-001
STS 890
REF 1700083-001 Set comprising
REF 1600167-001
REF 1600312-001
REF 1600161-001
REF 1600161-001
REF 1200022-001
REF Legend
1600167-001 SF 811 module 1700080-001 Set SF 811 module with pedal 1700083-001 Set SF 811 module with pedal and TD 783 1600388-001 STS 890 module 1700092-001 Set STS 890 module 1600318-001 S001 module 1700126-001 Set S001 module with pedal and TD 783 1700127-001 Set S001 module with pedal 1600161-001 TD 783 turbine for hose with internal Ø 1/8" (3.17mm),
with Friction Grip chuck (FG)
1600163-001 TDS 890 turbine with spray,4-hole connection,
Friction Grip (FG) 1600312-001 Pedal for S001 and SF 811 module 1600389-001 Pedal for STS 890 module 1200022-001 Grey coiled hose for S001 and SF 811 module 1600390-001 Hose straight with 4-hole-coupling for STS 890 module
List of Bien-Air registered trade mark products ®:
Aquilon
®
Bora Boralina
®
®
®
Eolia
®
Gyro Gyrolina
®
Isolite
®
Lubrifluid
®
Lubrimed
®
®
MX Prestilina Spraynet
®
®
In these instructions, “Device” corresponds to the product described in the heading “Type”. For example, turbine, contra-angle, handpiece, micromo­tor, tube, electronics, connectors, station etc.
Symbols
CE Marking with number of the notified body
This product may be covered by one or more of the following patents: EP Europe: 0 497 139 / 0 526 783 / 0 745 358 / 0 688 539 / 0 894 879 / 1 145 688 / 1 109 301 DE Germany: 296 16 023.7 DK Denmark: 96 00315 FR France: 2 679 804 /2 722 972 /2 733 680 /2 692 621 / 2 720 263 /2 757 763 /2 766 697 CN China: 129343 JP Japan: 2 037 611
/2 781 318 CH Switzerland: 693 922
/ 1 991 770 US United-States:
5.059.122 / 4.773.856 /6.033.220 / 6.337.554 / 5.453.008 / 6.319.003 /
6.495.937
REF 1600167-001 CONSOLE SF811 / REF 1600388-001 CONSOLE STS890 / REF 1600318-001 CONSOLE S001 / REF 1700083-001 SET SF811+TD783 / REF 1700092-001 SET STS 890 / REF 1700126-001 SET S001+TD783
REF 1600389-001
REF 1600163-001REF 1600390-001
Bien-Air Dental SA
Länggasse 60 Case postale 6008 2500 Bienne 6,
Switzerland Tel. +41 (0)32 344 64 64 Fax +41 (0)32 344 64 91
Bien-Air Italia s.r.l.
Via V
aina 3 20122 Milano, Italia Tel. +39 (02) 58 32 12 51/52/54 Fax +39 (02) 58 32 12 53 ba-i@bienair.com
office@bienair.com
Bien-Air UK Limited
Bien-Air Deutschland GmbH
Jechtinger Strasse 11 79111 F
reiburg, Deutschland Tel. +49 (0)761 45 57 40 Fax +49 (0)761 47 47 28 ba-d@bienair.com
Bien-Air España SA
Entença, 169 Bajos 08029 Bar
celona, España Tel. +34 934 25 30 40 Fax +34 934 23 98 60
63, The Street Capel,
Surr
ey RH5 5JZ, England
Tel. +44 (0)1306 711 303
+44 (0)1306 712 505 Fax +44 (0)1306 711 444 ba-uk@bienair.com
Bien-Air Asia Ltd.
Nishi-Ikebukuro Daiichi-Seimei Bldg.
10F 2-40-12 Ikebukuro, Toshimaku Tokyo, 171-0014, Japan
ba-e@bienair.com
Bien-Air USA, Inc.
Medical Technologies 5 Cor
porate Park
Suite 160
Tel. +81 (3) 5954-7661 Fax +81 (3) 5954-7660 ba-asia@bienair.com
Irvine, CA 92606 USA Phone 1-800-433-BIEN Phone 949-477-6050 Fax 949-477-6051 ba-usa@bienair.com
Beijing Bien-Air
Medical Instruments Technology Service Co. Ltd. R
oom 2106,
The Exchange Beijing
Bien-Air France Sarl
131, Boulevard Péreire 75017 P
aris, France
Yi 118 Jianguo Road Chaoyang District Beijing 100022, China
Tel. +33 (0)1 47 64 13 49 Fax +33 (0)1 40 54 91 43 ba-f@bienair.com
Tel. +86 10 6567 0651 Fax +86 10 6567 8047 ba-beijing@bienair.com
REF 2100024-ENG/06.08 2/2
Loading...