The IWA Series can be remotely controlled via infrared, wall-mount, or custom controls (see pages 2 & 3). Remote control capability is provided by an optional (user installed) Remote Control PCB (printed circuit board). The Remote Control PCB allows remote control of Main & Zone Output levels, as well as switching of three relays (included on circuit board). Connections are provided for up to two remote controls, which may then be assigned the necessary functions for a specific location or application. A non­volatile memory allows storage & recall of up to eight presets (levels & relays).
The Remote Control PCB is installed at the lower-left of the mixer PCB (see diagrams). Remove two jumpers from both P4 & P5 (on mixer PCB), and screws from the four stand-offs. Mate receptacles J4 & J5 (on rear of Remote Control PCB) to P4 & P5, and secure the PCB with the four screws. A power wire harness is tie-wrapped to the mixer wire harness. Cut tie-wrap and push connector onto J1 (at upper-right of PCB). Connections for remote controls are provided at the lower-right. The "normally open" contacts for three DPDT relays are provided at the upper­left ("normally closed" contacts are provided as wiring pads next to each relay). The relay contacts are rated for 5 Amps max.
The Remote Control PCB provides an infrared receiver at the right edge (IR1) for "set-up" purposes (see page 2). After set-up, this receiver may be disabled via the adjacent jumper (J6). Two jumpers are provided near the center of the PCB (J2 & J3). Once presets have been stored, jumper J3 allows remote control "store" buttons to be disabled. When power is turned on, the most current settings will be recalled, however, jumper J2 allows preset #1 to be recalled instead. LEDs indicate status of each relay, as well as reception and errors from remote controls. A switch and LED (at bottom edge) are used to enter "set-up" mode.
MIXER PCB
REMOTE CONTROL PCB
RELAY 1 (A) RELAY 2 (B) RELAY 3 (C)
RELAY 1
J5
RELAY 2
REMOTE STORE RECALL LAST
SETUP
RELAY 3
RELAY 3RELAY 2RELAY 1
YES NO YES NO
+48V
GND
GND
+15v
ERROR
J4
J2J3
IR2 IR3 GND IR2 IR3
REMOTE1 REMOTE2
RECEIVER
OFF ON
IR
-15v
-15V
J6
+15v
J1
IR1