ACCESSORY
Remote Control Bus Hub
NEW
The Remote Control Bus Hub provides eight parallel ports for the connection of remote control devices
to an Audia® or Nexia® system. Each port can accept multiple remote controls connected in a 5-wire
daisy-chain. A single Hub, connected to a single Audia or Nexia unit, allows multiple branches to be
added to the remote control network. The Remote Control Bus Hub can be used with any combination
of control devices, including Volume 8, Select 8, Volume/Select 8, Logic Box, and Voltage Control Box.
FEATURES
eight parallel ports on 5-wire plug-in barrier-strip connectors
allows multiple daisy-chain branches on a control network
any combination of Audia/Nexia controls on each branch
cable length extended to sum of two longest branches
convenient key-hole mounting (local power not required)
RoHS compliance
covered by Biamp Systems' five-year warranty
ARCHITECTS & ENGINEERS SPECIFICATION
The control bus hub shall provide eight parallel ports, on 5-wire plug-in barrier-strip connectors, for connection of remote control
devices to Audia
branch shall be capable of accepting any combination of Audia/Nexia control types, including Volume 8, Select 8, Volume/Select 8,
Logic Box, and Voltage Control Box. The control bus hub shall allow maximum cable length of 1000' to be determined as only the
sum of the two longest branches in the network. The control bus hub shall include key-hole mounting, and shall require no local
power source. The control bus hub shall be compliant with EU Directive 2002/95/EC, the RoHS directive. Warranty coverage shall
be five years.
The control bus hub shall be a BIAMP Remote Control Bus Hub.
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com
®
or Nexia® systems. The control bus hub shall allow multiple daisy-chain branches on a control network. Each
SPECIFICATIONS
®
dimensions (H x W x D)
power consumption
controls per system device
control cable requirements
control cable length
control bus wiring
compliance
EXAMPLE CONTROL SYSTEMS
Remote Control Bus Hub
VS8
-
1.464" x 10.575" x 3.25" (37.19mm x 268.6mm x 82.55mm)
-
750mW @ 12~24 Volts DC (from Audia/Nexia device)
-
32 (Audia); 12 (Nexia); any combination (includes RCB Hub)
-
5-wire data grade (95~120 ohm nominal impedance)
(16 pF/ft. max. capacitance) (65% min. velocity of prop.)
recommended cables: Gepco 18/22AXL, Liberty AXLINK,
Liberty CRESNET, or equivalent
-
1000 feet / 300 meters (sum of longest two hub branches)
-
single daisy-chain (with final device terminated) per branch
-
EU Directive 2002/95/EC, the RoHS directive
AUDIA system maximized @ 32 devices and 1000' cable
(total cable length on each of Ports 1~6 is less than 400')
87654321
500'
V8
S8
LB
VCB
AUDIA
terminate
NEXIA system maximized @ 12 devices and 1000' cable
(total cable length on each of Ports 2~7 is less than 500')
300'
200'
VCB
terminate
S8
LB
terminate
LB
terminate
V8VS8
V8
terminate
VS8
terminate
terminate
S8
S8
terminate
VS8VS8VS8
VS8S8V8V8 V8
VS8
terminate
Remote Control Bus Hub
VS8
terminate
VS8 VS8
350'
S8 VCB VS8V8 VS8
LBVS8S8
VCB
terminate
50'
LB
terminate
VS8
VS8
terminate
terminate
50'
50'
VS8
terminate
87654321
300'
NEXIA
100'
LB
100'
VS8
terminate
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com
18Dec06