Biamp CM1-6WS, CM1-6W User Manual

Ceiling Microphone
Connector
Wiring Instructions
CM1-6W and CM1-6WS
June 2013
Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com
CEILING MICROPHONE CONNECTOR WIRING INSTRUCTIONS
PHOENIX CONNECTOR WIRING INSTRUCTIONS FOR CM1-6W and CM1-6WS CEILING MICROPHONES
hole.
MALE &
CEILING TILE
WITH 5/8″
HOLE
CM1-6W
FEMALE
PHOENIX CON
NECTORS
JBM40 PLENUM
RATED BOX
-
BRASS STRAIN RELIEF
FOR OUTER
CABLE
SLOTTED
MOUNTING
NUT
Step 3: Insert external wire through strain relief nut, then connect the wire to the Phoenix terminal. Recommended wire: Belden 9451P - .124” O.D. or Belden 82761 - .116” O.D.
Step 2: Open back lid of junction box. Separate the supplied phoenix connector (male/female).
Step 4:
Wiring: 1 = Ground 2 = Blue (+) 3 = Yellow (-)
Step 5: Reconnect Phoenix terminals.
Step 6: Tighten down the strain relief nut to hold wire rmly in
place and close junction box lid.
585.0401.90A
2