AMP-450BP PoE+ Amplier
Installation & Operation Guide
Setup and Use
The Tesira software provides an intuitive interface for setup and programming of the AMP-450BP. The information supplied by this manual relates to
physical connections and device setup. For more details on software setup,
please consult the Tesira Help File.
Installation
Product Description
The AMP-450BP is a four-channel PoE+ (IEEE 802.3at Class 4, 30W)
conferencing amplier for use in Tesira® systems. Suitable for air handling
spaces, the amplier is designed to be mounted directly to the back of a
desono™ C-IC6 loudspeaker, minimizing cabling requirements.
Each AMP-450BP comes with an optional enclosure to protect electrical
connections and comply with typical code requirements for above-ceiling
installations. The AMP-450BP includes an internal limiter, and is capable of
providing 3 watts of continuous power to all four channels.
The Tesira AMP-450BP is also capable of operating in a burst mode to
handle peak signals, providing up to 50 watts (4Ω load) or 30 watts (8Ω
load) per channel. The output channels are software congurable, including
selectable power versus channel count.
The amplier serves as a dedicated endpoint in a Tesira system, making
installations easier to design, support, and maintain. The AMP-450BP is ideal
for TesiraFORTÉ®-equipped conference rooms or other applications where
sound reinforcement is needed.
Install away from heat sources, such as vents, radiators, heat registers and
stoves. Also avoid installing near water or steam. The conferencing loudspeaker has a secondary support point via chain or wire for connecting to the
building structure. Do not exceed the maximum ambient operating temperature of 32° - 104° (0° - 40° C).
Features
• Four channels; 3 watts of continuous power per channel
• Burst mode to handle peak signals in accordance with ANSI/CTA-
2006-B; supports up to 50 watts (4Ω load) or 30 watts (8Ω load) per
channel
• Powered by PoE+ (IEEE 802.3at Class 4, 30W)
• Class D amplier topology
• Fan-less operation
• Includes internal limiter function
• Software-selectable power versus channel count
• Evaluated to the requirements of UL 2043 and is suitable for use in air
handling spaces
• LED indicators for power and amplier status
• Congurable via Tesira software
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA T: +1 503.641.7287 W: www.biamp.com
JUNE 2019

Front Panel and Connectors
3. Locate
1. AVB/Control
Facilitates connection to the Tesira AVB network for audio and control. This
RJ-45 port may either be connected directly to the Tesira AVB port (via a
PoE+ injector) for a single device system or via a PoE+ network switch in a
multi-device AVB system. IEEE 802.3at Power over Ethernet Plus (P0E+)
Class 4 is required as there are no other provisions for power inlet.
2. Power/System LED Status Indicator
A multi-color LED provides information about the status of the device
Status LED Indicator
No Power Off
Powered but not ready to receive conguration Red Solid
Ready to receive conguration or updating rmware Yellow Solid
Congured and ready to participate in the system Green Solid
Amplier is in Locate mode (triggered from the software) Green Flashing
Unit has a Major Alarm condition Red Flashing
Unit has a Minor Alarm condition Yellow Flashing
Unit has both a Major and Minor Alarm condition Red/Yellow Flashing
Pressing the locate button will play an audible signal that cycles through
each connected output.
4. Amp Status
A multi-color LED provides information about the status of the amplier.
Status LED Indicator
No Power Off
Clip detected Red Solid
Amplier limiter engaged Yellow Solid
Powered Green Solid
Amplier is in Locate mode (triggered from the software) Green Flashing
Amplier has failed to initialize, an error is present, or the
amp is temporarily muted due to an audio burst
PoE+ power is not available or insufcient to power the
amplier so it has been turned off
Red Flashing
Red/Yellow Flashing
5. Outputs 1-4
RJ-45 speaker connections. 4 x 3W RMS or 2 x 7W RMS or 1 x 15W RMS
output at low impedance 4Ω/8Ω.
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA T: +1 503.641.7287 W: www.biamp.com
JUNE 2019

desono Speaker Installation
The AMP-450BP is designed to power and mount on top of a C-IC6
desono™ loudspeaker. The AMP-450BP includes an optional cover to
protect Euroblock and RJ-45 connections on the AMP-450BP and desono
loudspeaker.
See Figures 1 through 3 at right. To install the AMP-450BP on the desono
loudspeaker, do the steps that follow:
1. If installed, remove the connector cover from the desono loudspeaker.
2. Place the AMP-450BP on top of the desono loudspeaker. Tighten the
attachment hardware.
3. Connect the loudspeaker to the AMP-450BP with Ethernet cable via the
RJ-45 ports on both devices.
4. Connect additional speaker cabling to the AMP-450BP per design
requirements.
5. If installing the optional AMP-450BP cover, make sure knock-outs are
removed as required.
6. Feed cabling through the knock-outs and install the cover on to the
loudspeaker and amplier.
Figure 1 - AMP-450BP Installation
a. The cover attachs to the AMP-450BP/C-IC6 via clips and a
thumbscrew.
7. Install the speaker per the appropriate desono Installation and Operation
Guide.
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA T: +1 503.641.7287 W: www.biamp.com
Figure 2 - AMP-450BP Cover Installation
Figure 3 - AMP-450BP Final Installation
JUNE 2019

Wiring and Connections
The AMP-450BP connects to a Tesira AVB network for audio and control via
the AVB/Control RJ-45. Cabling should be Cat 5e or better.
The AMP-450BP has four RJ-45 ports (channels) for speaker connections.
Continuous Power Output:
• Single Channel Driven (4Ω, 8Ω): 15W
• Dual Channel Driven, (4Ω, 8Ω): 7W
• Four Channel Driven, (4Ω, 8Ω): 3W
C-IC6 Wiring Connections:
Wiring Examples:
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA T: +1 503.641.7287 W: www.biamp.com
JUNE 2019