BG Electrical TWE7 Technical Data Manual

Technical Data
Wall Timer Switches
Brief product description:
The subtle design will blend with any décor - suitable for domestic or commercial installations.
Timer allows lighting to be turned on and off when you are away.
Technical Specifications
Standard(s)
Rating
Terminal Capacity
RoHS Directive
WEEE Directive
Mounting Box Depth(Min)
Fixing Centres
Size
BSEN60669-1
40 - 400W Tungsten filament lamps
2 x 1.5mm²
No
No
16mm
60.3mm
86mm x 86mm x 46mm
Features:
settings
the event of a power failure (24 hours)
suitable for fluorescent lighting,
TWE7
Line Diagrams
TWE7
Packaging Information
Cat No. Description
TWE7 7 Day Wall Timer Nexus
Packaging Type
Product Each IndividualInner Box Inner
Clamshell
Weights & Dimensions
Cat No. Description Dimension (W x L x H) cm
TWE7 7 Day Wall Timer
Product EachInner Box Inner
xxxx xxxxxxxx xxxxxxxxx xxxxx xxx
Outer Box Outer
Pack Quantity
Box
1 5050765018791Nexus Inner 5Nexus Outer 50
Weight (g)
Box
Box
Box
CMB (m3)
Outer Box
Barcode
Inner BoxOuter Box Outer
Outer Box
Wall Timer Switches
Installation Information
Safety Warning
Before use please read carefully and use in accordance with these safety wiring instructions.
Before commencing any electrical work ensure the supply is switched off at the mains. Either by switching off the consumer unit or by removing the appropriate fuse.
Wiring should be in accordance with the latest edition of the IEE regulations (BS 7671).
Wire Identification – Twin & Earth Cable
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
To prevent fire hazard always use cable of the correct rating, size and type for the application. Note - If your installation uses a four lug metal mounting box, remove the top and bottom lugs or bend fully back.
1. Manual Switch
2. Mode Selector
3. "CLOCK" Button
4. "PROG" Button
5. "Time Recall/Cancel" Button
6. "MIN" Button
7. "HOUR" Button
8. "DAY" Button
9. "Reset" Button
10. Fuse (3 Amp, BS646)
11. Red Indicator Light
12. Display
13. Control Cover
NOTES
- The internal battery may require up to 2 hours to charge before first use, or long periods of non-use. To charge the unit must be connected to the mains power supply – and the switch turned ON (under load conditions)
- Timer tolerance +/- 2min per month
- Max load = 400W or 2.5 Amps
- Only suitable for most tungsten lament lamps
IMPORTANT
Do not use with fluorescent lighting, low energy CFL, low voltage
Installation Instructions
The unit is designed to be used in place of a standard light switch in a one-way or two-way standard circuit. Connections to other circuits are possible but beyond scope of this instruction, so please consult a qualied electrician for advice. The rear face of the unit has a terminal block with 3 connections:
Technical Helpline: 0845 194 7584
If in doubt consult a competent electrician.
If the Timer switch is required at the end of circuit without an existing Live connection, one of the existing wires will need to be used to extent the Live connection to the unit.
Remove existing light switch & note the numbers of wires, excluding any Earth connections & proceed as below:
For a one-way circuit there should be only 2 wires.
Typical One-Way Circuit
Connect:
1. Live wire to the LIVE terminal.
2. Switched Live wire to the LOAD terminal
LIVE: for connecting Live LOAD: for connecting switched live to Light bulb or Load 2-WAY: for use with 2-way circuits only
Note - It is important that a Live connection to the unit exists to provide permanent power for
the timer, especially on 2-way circuits where the Live connection will only be at one switch.
For a two-way circuit, depending on how it is wired, there may be either 3 wires at both switches OR 3 wires at one switch & 5 wires at the other.
Typical Two-Way Circuit (3 Wires Both Ends)
Connect:
1. Live wire to the LIVE terminal.
2. COM (or C) from other switch to LOAD terminal
3. L1 from other switch to 2-WAY terminal
4. Switched Live wire to the other switch COM terminal L2 on other switch has no connection, & wire MUST be isolated by connecting to a seperate terminal block or similar.
This circuit normally uses 3-core insulated cable to connect between the COM, L1 & L2 ter­minals between both switches. The end of the circuit with 5 wires also includes the Switched LIVE & LIVE wires.
Typical Two-Way Circuit (5 Wires One End, 3 Wires Other)
Connect:
1. Live wire to the LIVE terminal.
2. COM (or C) from other switch to LOAD terminal
3. L1 from other switch to 2-WAY terminal
4. Switched Live wire to LOAD terminal
L2 on other switch has no connection, & wire MUST be isolated by connecting to a separate terminal block or similar.