WiPR Wireless Pressure Reader
Quick Start Guide
WiPR Quick Start Guide Version 1.4. F1-90-2248-A

Quick Start Guide
A device that enables the user to test BERU wheel sensors and gather diagnostic information.
Operation
–
To turn the device on / off press ▼+ ● button together and hold (auto power off after 2mins if no buttons are pressed).
–
Whilst powering up, the device will display the battery status i n the bottom right hand corner.
bf1sy stems
WiPR
433MH z
SW:0 .12
- - - - -
MORE TRIGG
–
Once the device is powered up, hold it within 20cm of the tyre valve and press ● button (TRIGG) to trigger the sensor.
TRIG GERING
X X X X X X
–
Once the sensor has been triggered it will transmit data, and the tyre pressure screen will be displayed. The sensor serial number will also be displayed at the
bottom of the screen.
MORE
MORE TRIGG
12345678 90
MOREMORE
12345678 9012345678 90
–
Press ▼ (MORE) to display the current tyre temperature.
MORE
MORE TRIGG
12345678 90
MOREMORE
12345678 9012345678 90
–
Press ▼ (MORE) to scroll to the next display that will show the sensor seri al number, tyre pressure, temperature, RBL (Remaini ng Battery Life in months),
sensor MODE and sensor generation.
SER No: 1 23456789 0
P: 2.2bar
RBL: 118
MORE
MORE TRIGG
MOREMORE
GEN
GEN ::::2222
GENGEN
TEMP: 2 4C
MODE: 4 1
TRIGG12345678 90
TRIGGTRIGG
TRIGG12345678 90
TRIGGTRIGG
TRIGG
TRIGGTRIGG
Settings
You can access and change the settings of your device by pressing and holding ▼ for 2 seconds; this will give you the following options.
–
Mode
The mode settings page allows the sel ection of 433MHz or 315MHz and LIVE or TRIGGERED operating mode.
Select the correct receive frequency prior to triggering or listeni ng for a wheel sensor. See lookup table for reference.
SETTINGS-MODE
BAND [433]
TRIG
SELECT
SELECT TOGGLE
TOGGLE
SELECTSELECT
TOGGLETOGGLE
[TRIG]
TOGGLE
TOGGLETOGGLE
TOGGLE
TOGGLETOGGLE
TOGGLE
TOGGLETOGGLE
SETTINGS-UNITS
PRESSURE bar
TEMPERATURE [C]
SELECT
SELECT TOGGLE
SELECTSELECT
TOGGLE
TOGGLETOGGLE
When the LIVE option is selected, the W iPR will receive datagram’s from all BERU wheel sensors transmitting within the receive range.
When the TRIGGERED option is selected; the W iPR will only receive datagram’s triggered after the TRIGG button has been pressed.
SETTINGS-MODE
BAND 433
SELECT
SELECT TOGGLE
SELECTSELECT
Hold ▼ for 2 seconds to access the UNITS page.
–
Units
To toggle between temperature and pressure press ▼
You can change either of these settings by pressing ●. Thi s will toggle between °C / °F for the temperature, and bar / psi for the pressure.
SETTINGS-UNITS
PRESSURE [bar]
TEMPERATURE C
SELECT
SELECT TOGGLE
SELECTSELECT
Hold ▼ for 2 seconds to access the AUDIO page.
–
Audio
You can toggle the LF transmission and RF reception audible indicators on and off.
SETTINGS-AUDIO
RFRx [ON]
SELECT
SELECT TOGGLE
SELECTSELECT
Hold ● for 2 seconds to return to the operation screens at any time.
WiPR Quick Start Guide Version 1.4. F1-90-2248-A

Battery Status and Charging
Should the battery voltage fall below a pre-defined warning limit the device will display a warning message accompanied by an audible warning.
If the battery voltage falls below a pre-defined critical level the device will display a warning message accompanied by an audible warning, then the device will power off.
To charge the WiPR, connect on mini USB lead with a suitable power supply e.g. Phone charger. Typical charge time is 2-3 hours.
The device cannot be used whil e charging. If powered up whilst charging, the charging message will be displayed and the unit will automatically power off.
Error Messages
If a sensor is not triggered the unit shall i ndicate that no sensor data has been received.
SENSOR NOT DE TECTED
SETUP TRIGGER
Sensor errors are defined as either hardware and/or measurement errors:
SE RI A L: 12 34 56 78 90
P:2.4 B ar T:33C
SENSO R FAUL T – H/W ARE
SETUP TRIGGE R
Or the remaining sensor battery l ife is low.
SE RI AL :1 23 45 67 8 90
P:2.4 Ba r T:33C
SENSOR FAULT – BATT L O
SETUP TRIGGE R
Precautions
Statement of compliance to FCC regulations
Section 15.19: Labelling requirements
This device complies with Part15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Please note that any changes or modifications not expressly approved by BERU f1systems could void the user’s authority to operate the equipment.
Manufacturer: BERU f1systems, Diss, UK
Part Number: F1-100-1290-003
Warranty: 12 months
For full technical data sheet visit:
http://www.thewipr.com/
SE RI AL :1 2 345 67 8 90
P:2.4 B ar T:33C
SENSOR FAULT - MEASURE
SETUP TRIGGER
–
Do not drop.
–
Avoid storage in extremes of temperature.
–
This device is not waterproof, do not immerse in water.
–
Do not operate near a heart pacemaker.