Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.
RAD
LED Traditional Wall Pack
Beyond LED’s RAD wall pack is the newest and feature
rich product of 2021 offering a traditional design for the
innovative LED Technology providing up to 145 lumens
per watt efficacy. It offers three wattages selection with
energy-efficient LED technology and optional
installation accessories including surge-protector,
motion sensor, wire guard, shield, and an emergency
backup. RAD comes with a built-in photocell and is
available in die cast aluminium housings with a
polycarbonate lens to stand up for many years of
punishing environmental conditions.
• Operating temperature: -40°C to 50°C
• Durable die-cast aluminum housing
• Built-in photocell
• Enclosure provides a water-tight seal making it suitable for outdoor application
• Integral LED driver (60W isolated driver and 120W non-isolated driver), eliminates the need for
an external driver or ballast
• Up to 145 lumens per watt
• Three selectable wattage
• Complies with UL safety regulations and is DLC5.1 listed
• High Quality and Efficacy Lumiled 2835 chips
• This product is IP65 rated, therefore, it is waterproof, sealed and gasketed wire
• Universal operation at 120-277Vac 50-60Hz
• Environment friendly with no mercury
• Easy to install and operate, with instant and no humming
• Energy saving, long lifespan

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.
Up to 60W Wattage adjustable
40W /50W /60W
Beam Angle (50%)
(Tolerance : ±15%)
-40℃ TO 50℃
Storage Temperature
SKU NUMBER 153459 Specifications

Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.
Up to 120W Wattage adjustable
120W /100W /80W
Beam Angle (50%)
(Tolerance : ±15%)
-40℃ TO 50℃
Storage Temperature
SKU Number 153462 Specifications

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.
Correlated Colour Temperature (CCT)

Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.
Luminaire Data
Voltage: 119.9 V
Current: 0.486 A
Power: 58.12 W
Power Factor: 0.996
SKU Number 153459 Light Distribution Testing Parameters

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.
Luminaire Data
Voltage: 120.0 V
Current: 1.03 A
Power: 123.54 W
Power Factor: 0.995
SKU Number 153462 Light Distribution Testing Parameters

Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.
1. Be careful to open the carton, contact us if any damage.
2. This product must be installed in accordance with the applicable installation, code by a person familiar
with the construction and operation of the product and the hazards involved.
3. “caution - risk of shock” and “disconnect power before servicing” when photoelectric switch provided.
4. Please check whether the voltage marked on the luminaire is consistent with the input voltage to be
connected, so as not to damage the LED luminaire.
5. To ensure the lifetime of the product, please do not use it in a place with strong acid mist.
6. Make sure the installation position can withstand 10 times the weight of the luminaire before installation
and install it at a flat place without vibration, no swing, no fire hazard.
Caution
➢ Please turn off power before install or change assembly parts.
➢ The input voltage and lamps should be matched, after connecting the power line,
Please make sure the wiring section is insulated.
➢ No-professionals, must not install and disassemble the lamps.
Caution
Notes Before Installation

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.
Installation Instructions

Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.

Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.
Turn off the power and turn on again in 3 minutes.
If same phenomena occur, then call agencies.
Please check the connection.
Wattage adjustable instruction
Turn the wattage adjustable knob to a certain wattage gear, the power of the lamp
will change to the corresponding wattage.
Note: Please turn off the power before adjusting the wattage.

Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Du e to c ontinuous product improv ement, informat ion in this documen t is su bject to cha nge.
**Tolerance of Carton Size: ±15 MM, Tolerance of Weight: ±10%.
1. Please do not shake it too much during transportation, handle carefully when unloading.
2. Recommended to be stored in a warehouse of -10~ +60 ℃ and keep the warehouse dry.

(866) 786-1117 • www.BeyondLEDTechnology.com
Due to continu ous p roduct improve ment, information in thi s docum ent is subjec t to c hange.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts,
cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box
and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
precautions.
Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed
electrician.
For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a
qualified licensed electrician and check your local electrical code.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit
installation.
WARNING: RISK OF FIRE OR ELECTRICAL SHOCK
Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Turn off the power when you perform any maintenance.
Verify that supply voltage is correct by comparing it with the luminaire label information.
Make all electrical and grounded connections in accordance with the National Electrical Code and any
applicable local code requirements. All wiring connections should be capped with UL approved wire
connectors.
CAUTION: RISK OF INJURY
Avoid direct eye exposure to the light source while it is on.
Account for small parts and destroy packing material, as these may be hazardous to children.
Warranty
5 Years Warranty