Bewator BM3 Installation & User Manual

1 2 3
65
98
4
7
B0
A
B
Installation &
User Manual
EN SV DE FR DA FI NO
Book Contents
English ............................................................3
Svensk...........................................................33
Deutsch .........................................................63
Français ......................................................... 97
Dansk ...........................................................131
Suomi .......................................................... 161
Norsk............................................................191
BM3 Installation & User Manual 3
ENG
English
Copyright © 2006 Bewator AB, Solna.
Material from this manual may only be copied with the consent in writ­ing of Bewator. Bewator reserves the right to alter both the content of the manual and the design of the product without notice.
Document no: 80641-4
Bewator AB are parts of Bewator Group, which develops and markets a complete security product range that includes, access control, video control and alarm. Sales, installation and servicing are handled by a national dealer network.
Actions (such as unauthorised manipulation, copying etc.), must not be taken with the software contained in the products and systems. Such actions are regarded as copyright violation and may result in imprison­ment or fines and may likewise lead to an obligation to pay damages and compensation for using the software
4 BM3 Installation & User Manual
ENG
Content
What is Bewacom? ......................................... 5
How Bewacom works.......................................................5
Points to remember .........................................................6
Time control of the access codes......................................6
Monitoring camera ..........................................................7
Limitations ..................................................................... 7
Connecting Bewacom to a telephone system ....................8
Installing Bewacom ........................................ 9
The keypad ....................................................................11
Installation ................................................................... 12
Programming ............................................... 14
Internal sounder and LEDs ............................................. 14
Setting a password ...................................................... 15
Setting Bewacom to programming mode ....................... 15
Programming access codes (first time) .......................... 16
Changing access codes ..................................................17
Erasing access codes .....................................................18
Changing the door unlock time ...................................... 18
Extending the opening time 10 times .............................18
Changing the calling time .............................................. 19
Extending the calling time 10 times................................ 19
Time control of the telephone opening function .............20
Background lighting...................................................... 21
Internal sounder ........................................................... 21
Possibility to call the Bewacom .....................................22
”Hotline” ......................................................................22
Change number of digits in the extension ......................23
Erasing the memory ......................................................24
This is how the new door telephone works ....28
Calling Bewacom .......................................... 29
Troubleshooting ........................................... 30
Technical specifications ............................... 32
BM3 Installation & User Manual 5
ENG
What is Bewacom?
Bewacom is a door telephone which can be directly connected, like an extension, to an internal telephone system (PABX).
Using the Bewacom, visitors may call any tel­ephone connected to the telephone system. The person answering the telephone can talk to the visitor and open the door from the exten­sion telephone.
Bewacom includes a built-in codelock to allow access for staff.
How Bewacom works
To make a call from the Bewacom, the visitor presses B + the desired extension on the key­pad. Available extensions should be displayed on a name plate next to the door.
At the other end, the telephone rings as usual. It is possible to speak with the visitor for 30 seconds (extendable).
To open the door, the person called presses 5 on the telephone keypad and hangs up. To not open, press 0 and hang up.
6 BM3 Installation & User Manual
ENG
Points to remember
Bewacom only allows communication in one direction at a time. Each person must speak in turn for satisfactory communication.
Time control of the access codes
The access codes can be time controlled from external time clock(s) connected to the Bewa­com. For example, the cleaning staff code could only be valid certain times, while other codes should operate 24 hours a day.
By connecting two time clocks, three time zones can be used: one controlled by time clock 1, one by time clock 2 and one that is valid 24 hours a day, i.e. no time control.
The access codes can be programmed to the required time control group.
BM3 Installation & User Manual 7
ENG
Monitoring camera
If desired, a CCTV camera can be controlled from an output of the Bewacom. The camera will be automatically activated when the visitor presses the B button and remain active during the calling time plus the door open time.
Limitations
Bewacom cannot normally call extensions be­ginning with 0.
8 BM3 Installation & User Manual
ENG
Connecting Bewacom to a telephone sys­tem
An analogue extension (two wires) must be used for the connection of Bewacom. The tel­ephones to be called by Bewacom must be able to send a standard tone signal to Bewacom for the door release function to work.
How to test whether the telephone system meets the requirements or not:
Connect an ordinary push button telephone to the Bewacom extension, and dial any of the other extensions on the telephone system.
Ask the person answering at the other end to press the 5 key on the telephone keypad. If a tone is heard, Bewacom should work correctly.
1�
2�
BM3 Installation & User Manual 9
ENG
Installing Bewacom
Install the Bewacom at a height of 120–140 cm (from the floor to the bottom edge of the Bewa­com). To cater for disabled persons, a suitable height is approximately 95 cm.
Open the Bewacom with the key supplied. The lock is located on the front.
Fasten the back plate against the wall, us­ing three screws as shown in the illustration below. Seal the screw and cable holes with sealant if the unit is externally mounted.
1�
2�
10 BM3 Installation & User Manual
ENG
Unless the unit is already mounted on a me­tallic earthed surface, earth the back plate. Use a separate cable to the earthing point. Make sure the front and back plate are con­nected with the internal strap.
Fit the front and check that the Bewacom is securely fastened.
3�
4�
BM3 Installation & User Manual 11
ENG
The keypad
1 2 3
65
98
4
7
B0
A
B
Red LED
Indicates busy tel- ephone line.
Red LED
Indicates busy tel­ephone line.
Yellow LED
Indicates key- presses.
Yellow LED
Indicates key­presses.
Green LED.
Lit to indicate door released.
Green LED.
Lit to indicate door released.
A.
Starts a program ming sequence, e.g. A29 to change calling time.
A.
Starts a program ming sequence, e.g. A29 to change calling time.
B. Press B + the desired extension to make a call. Press B + the 6 digit password to programme Bewacom
B. Press B + the desired extension to make a call. Press B + the 6 digit password to programme Bewacom
12 BM3 Installation & User Manual
ENG
Installation
SW1
9
8
7
6
CAMERA
TAMPER
0V
EXIT
TELE
2
1
12-24V
LOCK
13
12
11
10
15
14
1
2
3
4
5
2
+
4
1
5
6
7
8
3
9
10
12V 24V
11
BM3 Installation & User Manual 13
ENG
1
SW1 push button. Used to set the pass­word and erase the memory.
2
Connection to the telephone system.
3
Exit button. Connect terminal nos 12 and
13. Looped = door open.
4
Time control from the external time clock.
Input 1: Connect terminal nos 11 and 13. Input 2: Connect terminal nos 10 and 13.
Looped input = the codes are disabled.
5
Camera relay output.
6
Tamper switch. Normally closed when the housing is closed.
7
Power supply in, terminal nos 1 and 2.
8
Electric locking device. Dashed line refers to locks with failsafe function.
9
Speaker volume.
10
Microphone sensitivity.
11
Jumper for 12 or 24 V voltage supply. If above 20 V, set the jumper to 24 V.
14 BM3 Installation & User Manual
ENG
Programming
The sections below describe how to programme Bewacom.
Internal sounder and LEDs
During programming, guidance will be given by the internal sounder and the LEDs.
In the manual the LED indications are shown as follows:
m = OFF l = Lit Flashes
In programming mode before a function is chosen: Red and yellow LED flashes.
During programming: The LEDs are lit or off
depending on the function being programmed. Correct programming: Confirmed by a rising
signal – two quick beeps. Faulty programming: Confirmed by a falling
signal – two quick beeps.
NOTE!
Once programming mode has been entered, if a key is not pressed within 15 seconds, the unit will return to normal operation.
BM3 Installation & User Manual 15
ENG
Setting a password
The first thing to do is to set a password. You will later use the password each time you want to programme the Bewacom.
Open the Bewacom and turn it around so the circuit board can be seen.
Press the SW1 button (see the wiring dia­gram). ll
Enter the desired 6-digit password.
mm
Make a note of the password and store the note in a safe place.
Setting Bewacom to programming mode
To programme a function, set Bewacom to pro­gramming mode.
Press and hold the B button on the Bewa­com keypad until the beeper goes off an the yellow LED goes out (approx 3 seconds).
Enter the 6-digit password.
ll
1�
2�
3� 4�
1�
2�
16 BM3 Installation & User Manual
ENG
Programming access codes (first time)
Four different 4-digit entrance codes can be programmed.
Set Bewacom to programming mode. Press 0000. Enter the desired access code using 4 dig-
its. Enter the code once again. If the code is not to be time controlled,
press 0. If the code is to be time controlled, select the desired input (see below). 1 = the code can be timed from a time clock
connected to input 1.
2 = the code can be timed from a time clock
connected to input 2. Also see the wiring diagram. Follow steps 2-5 to programme the next
code. Press B to exit programming.
1� 2� 3�
4� 5�
6�
7�
BM3 Installation & User Manual 17
ENG
Changing access codes
Set Bewacom to programming mode. Enter the access code to change. Enter the new access code. Enter the new access code again. To only change the code – without changing
the time control group – press B now. If the code is not timed, press 0. If the is timed, select the desired input (see below). 1 = the code can be timed from a time clock
connected to input 1. 2 = the code can be timed from a time clock
connected to input 2. Also see the wiring diagram. Follow steps 2-5 to change the next code.
Press B to exit programming.
1� 2� 3� 4� 5�
6� 7�
18 BM3 Installation & User Manual
ENG
Erasing access codes
To erase a programmed access code:
Set Bewacom to programming mode. Enter the access code to erase. Enter 0000. Enter 0000 again. Press B. Press B to exit programming.
Changing the door unlock time
When Bewacom is delivered the door unlock time is set to 7 seconds.
Set Bewacom to programming mode. Press A28. Select the required unlock time in seconds
(01-99). Press B to exit programming.
Extending the opening time 10 times
Using this function the door unlock time can be increased by a factor of ten.
Set Bewacom to programming mode. Press A64.
1� 2� 3� 4� 5� 6�
1� 2� 3�
4�
1� 2�
BM3 Installation & User Manual 19
ENG
Press 1 to extend opening time 10 times. Press B to leave programming mode.
To deactivate the function, press 0 in step 3 instead.
Changing the calling time
When Bewacom is delivered the calling time is set to 30 seconds.
Set Bewacom to programming mode. Press A29. Select the desired calling time in seconds
(01-99). Press B to exit programming.
Extending the calling time 10 times
Using this function the calling time can be in­creased by a factor of ten.
Set Bewacom to programming mode. Press A61. Press 1 to extend the calling time 10 times. Press B to leave programming mode.
To deactivate the function, press 0 in step 3 instead.
3� 4�
1� 2� 3�
4�
1� 2� 3� 4�
20 BM3 Installation & User Manual
ENG
Time control of the telephone opening function
This will set the time period during which it will be possible to open the door from a telephone extension.
Set Bewacom to programming mode. Press A30. Select any of the following alternatives: 0 = Opening enabled 24 hours a day (deliv-
ery setting). 1 = Opening controlled by time clock con-
nected to input 1.
2 = Opening controlled by time clock con-
nected to input 2. 3 = The door cannot be opened from tel-
ephone extensions.
Press B to exit programming.
1� 2� 3�
4�
BM3 Installation & User Manual 21
ENG
Background lighting
This function allows you to turn off the keypad background lighting of the Bewacom. The de­fault setting is on.
Set Bewacom to programming mode. Press A60. Press 0 to shut off background lighting. Press B to leave programming mode.
To turn it on again, press 1 in step 3 instead.
Internal sounder
When Bewacom is delivered the internal sound­er is on. If the sounder is not required to sound on keypresses and door release, you can turn it off. Note that the sounder will still be sounding during programming.
Set Bewacom to programming mode. Press A65. Press 0 to shut off the sounder. Press B to leave programming mode.
To reactivate the sounder, press 1 in step 3 instead.
1� 2� 3� 4�
1� 2� 3� 4�
22 BM3 Installation & User Manual
ENG
Possibility to call the Bewacom
Using this function, the Bewacom can be called from the switchboard or from an extension to assist a visitor having trouble using the door telephone.
To enable the function:
Set Bewacom to programming mode. Press A66. Select and programme the desired 4-digit
code. The code is keyed in at the telephone to open the door.
Enter the code one more time. Press B to leave programming mode.
To deactivate the function, follow the above instruction, only press 0000 instead in steps 3 and 4.
On page 27 you will find instructions on how to call the Bewacom.
”Hotline”
By using the facilities of the telephone system, this function can be used to call a particular extension from a single push of the B button on the Bewacom. When this function is set, the Bewacom will seize the line immediately the B
1� 2� 3�
4� 5�
BM3 Installation & User Manual 23
ENG
button is pressed. No other number is permit­ted at this point (the keyboard is disabled). The telephone system is then programmed to respond to this ”hotline” condition.
To enable this function.
Set Bewacom to programming mode. Press A67. Press 1 to enable hotline. Press B to leave programming mode.
To deactivate the function, press 0 in step 3 instead.
Change number of digits in the extension
In some cases the PABX requires more than four digits in the extension number. You can select how many by doing as below:
Set Bewacom to programming mode. Press A92 Enter the number of digits with two digits
(01-99) Press B to leave programming mode.
1� 2� 3� 4�
1� 2� 3�
4�
24 BM3 Installation & User Manual
ENG
Erasing the memory
Using this function all programmed information in the Bewacom can be erased and the unit set back to factory defaults.
Set Bewacom to programming mode. Open the Bewacom and turn it around so
the circuit board can be seen. Press the SW1 button (see the wiring dia-
gram on page 10). Press 112186 on Bewacom’s keypad. Press 112186 again.
Bewacom now has the default settings:
Password: 112233 Opening time: 7 seconds Calling time: 30 seconds Door release from telephone: 0 Background lighting: ON Internal sounder: ON Possibility to call into Bewa­com:
OFF
Hotline: OFF Extended opening time: OFF Extended calling time OFF
1� 2�
3�
4� 5�
BM3 Installation & User Manual 25
ENG
Programming overview
Always start by pressing B and enter the programming code. Abort: Press B.
Function Step 1 Step 2 Step 3 Step 4 Step 5
Program
access-
code
Press 0000 Enter new
code (four
digits)
Enter the
code once
again
Enter time control
group
0 = no
1 = group 1
2 = group 2
Next code:
Carry on from
step 1. Abort:
Press B (returns
to program-
mering mode).
Change ac-
cess code
Enter code
to change
Enter new
code (four
digits)
Enter the
code once
again
Enter time control
group
0 = no
1 = group 1
2 = group 2
As above
Erase ac-
cess code
Enter code
to erase
Press 0000 Press 0000
igen
Press B. Press B to exit.
Change
opening
time
Press A28 Enter open-
ing time
(01-99)
Press B to
exit.
26 BM3 Installation & User Manual
ENG
Always start by pressing B and enter the programming code. Abort: Press B.
Function Step 1 Step 2 Step 3 Step 4 Step 5
Change calling time Press A29 Enter opening time (01-
99)
Press B to exit.
Time control of the
telephone opening
function
Press A30 0 = no
1 = input 1
2 = input 2
3 = opening disabled
Press B to exit.
Background lighting Press A60 0 = OFF
1 = ON
Press B to exit.
Internal sounder
on/off
Press A65 0 = OFF
1 = ON
Press B to exit.
Door unlock time
extended by a factor
of 10
Press A64 0 = OFF
1 = ON
Press B to exit.
Calling time extend-
ed by a factor of 10
Press A61 0 = OFF
1 = ON
Press B to exit.
BM3 Installation & User Manual 27
ENG
Function Step 1 Step 2 Step 3 Step 4 Step 5
Possibility to call
into Bewacom
Press
A66
Enter code (four digits) Enter the
code once
again
Press B to
exit.
Hotline off/off Press
A67
0 = OFF
1 = ON
Press B to
exit.
Change maxnumber
of digits in exten-
sion
Press
A92
Enter number of digits
(01-99)
Erase memory Open
Bewa-
com
Press SW1 on the circuit
board
Enter
112186 on
the keypad
Enter 112186
once again
28 BM3 Installation & User Manual
ENG
This is how the new door telephone works
We have recently installed a door telephone which will be in use from _________.
If access codes are used you may enter a 4-digit code to open the door. The code is ______.
The code is valid: Monday – Friday between _____ and _____ ____________________________________ When your visitor arrives they should press
B on the door telephone keypad and then enter the reception number or your extension number.
You may talk to the visitor for _____ seconds. To open the door, press 5 on your telephone’s
keypad and hang up. To not open the door, press 0 and hang up.
BM3 Installation & User Manual 29
ENG
Calling Bewacom
This is how to call the door telephone, e.g. if you want to assist a visitor trying to get in.
Dial the door telephone extension number. The line is connected so you can talk to the visitor.
To release the door enter a valid 4-digit ac­cess code (see page 20) To finish the call without releasing the door, press # on your telephone.
1�
2�
30 BM3 Installation & User Manual
ENG
Troubleshooting
Problem Possible cause Action
Nothing hap­pens when a code is entered.
The code is timed.
Check connect­ed time clock.
Unable to enter programming mode. Red LED lit after two trials.
Wrong pass­word.
Determine the correct pass­word.
Green LED lit following an accepted code, but the door does not open.
Lock fault. Check cable
between door telephone and lock. Change locks.
Link between block nos 1 and 4 in Bewacom is missing.
Attach link.
The B button is pressed, but no dial tone is heard.
Faulty connec­tion between Bewacom and telephone sys­tem.
Check connec­tions and cable.
The door tele­phone extension is not analogue.
Check the tel­ephone system. Connect an ordinary push­button tel­ephone instead of Bewacom.