39
Parameter Description 
Default 
(IM...) 
Default 
(IR...) 
min MAX 
VENTILATION SPEED (P.W.M.) 
CF1  Evaporator fan min. speed  20 
20 
0 100 
CF2  Evaporator fan min. speed selectable in a quick cooling cycle  50 
50 
0 100 
I.F.R. 
B01  Room thermostating temperature in the first phase  -13°F  -13°F  -58°F  122°F  
B02  Subcutane T control start temperature  
86°F 86°F -58°F 210°F 
B03  First coefficient of the control relation 
-2 -2 -50 50 
B04  Second coefficient of the control relation 
16 16 -50 50 
B05  Third coefficient of the control relation 
-8 -8 -50 50 
B06  Subcutane T initial value determining the end of the first phase
34°F 34°F -58°F 210°F 
B07  Phase two formula coefficient 
10 10 0 99 
B09  Subcutane t min. value allowed durino the third phase 
30°F 30°F -58°F 210°F 
B10  End of intelligent quick cooling core temperature 
38°F 38°F -58°F 210°F 
B11 
Delay from the positive result of the needle test for starting the 
procedure to determine the end of the first phase 
60 sec  60 sec  0 sec  99 sec 
B12  First phase temperature detection time 
30 sec  30 sec  0 sec  99 sec 
B13  First phase min. duration 
6 min  6 min  0 min  99min 
B16  Defrost on starting intell. QC cycle (0=no 1=yes) 
0 0 0 1 
B17  Inhibition temperature 
176°F 176°F -58°F 210°F 
B18 
Room Set point in the event of automatic switch to time or 
temperature mode 
32°F 32°F -58°F 210°F 
B19  Max. duration possibile for intelligent QC process 
150 min  150 min  1 min 999 min
B20 
Subcutane T safety value determining the end of the first 
phase 
38°F 38°F -58°F 210°F 
B21  First coefficient of the room thermostating curve  (third phase)
-25 -25 -90 
99 
B22 
Second coefficient of the room thermostating curve  (third 
phase) 
-28 -28 -90 99 
B23 
Storing activation at the end of intell. QC cycle    (0 = no; 1 
= yes) 
1 1 0 1 
B24  Room thermostating Set-point in storing 
36°F 36°F -130°F 194°F 
B26  Core temperature limit for the timer start 
0 0 0 999 
B27  Adjuster of fans speed in the third phase 
0 0 0 99 
B28  Cold pulse adjuster 
0 0 0 99 
COMMUNICATION 
ADD  Device Address    1  1  1  147 
SC 
Serial Control : 
0 = not activated 
1 = print 
2 = ModBus 
1 
1 
0 
2 
MB1  BaudRate: 0 = 2400; 1 = 4800; 2 = 9600; 3 = 18200 
2 2 0 3 
MB2  Parity: 0 = no parity; 1 = odd; 2 = even 
2 2 0 2 
TYPE OF CYCLE 
G01 
Positive QC cycles only : 
0 = Positive and Negative 
1 = Positive only
0 0 0 1