IMPORTANT
INFORMATION
for
DW/SF SERIES
This cooler has passed the
QUALITY CONTROL INSPECTION
and meets the high standards at
Beverage-Air. This inspection includes
complete refrigeration system,
cabinet construction & finish.
809-002A
*
Quality Control Inspector, Beverage-Air
WARRANTY REGISTRATION CARD
Cabinet Serial No. _______________________
Original Purchaser _____________________________________________________________________
Address _____________________________________________________________________________
Installation Location ___________________________________________________________________
_____________________________________________________________________________________
Beverage-Air Model No. _________________________ Installation Date _______________________
This card must be mailed within 10 days after installation date to
You may also complete warranty registration at www.beverage-air.com
CITY STATE
NAME
ADDRESS
* Copy of Warranty
Available Upon Request
3779 Champion Blvd.
Winston-Salem, NC 27105
PLACE
POSTAGE
HERE
BOTTLE COOLER SERIES DW, SF MODELS
INSTALLATION AND OPERATING INSTRUCTIONS
• LOCATING COOLER
It is necessary to properly level cooler to provide adequate drainage and efcient functioning of the unit. Make sure there is
enough room around the cooler t assure good air circulation through the condenser.
• ELECTRICAL SUPPLY
Plug all standard models into a 115 volts A.C. 60 Hz. outlet. Low line voltage is often the cause of service complaints.
Check to see that the line voltage is 110 volts or more with the unit running. Other motors or heavy appliances should not
be used on the same circuit with the cooler. When working on the inside of the cooler, disconnect from electrical circuit for
safety reasons.
• STARTING UP OF UNIT
Factory setting of temperature control is at No. 5 position (normal) on control dial which will maintain the product at about
36°F. For colder temperatures, turn knob clockwise one number at a time. Number 9 position (coldest setting).
Excessive tampering with the control could lead to service difculties. Should it become necessary to replace the
temperature control, be sure it is ordered from an authorized Beverage-Air Distributor or direct from the factory.
• CAPCATCHER
To install capcatcher, place slotted holes over the two mounting screws and push down. The mounting screws are pre-set
at the factory for proper installation but should be turned in or out if further adjustment is required.
• DRAINAGE — DW, SF, MODELS
The condensation drains into a condensate disposal pan located just below unit compartment grill. This pan is equipped
with wicking to hasten the evaporation process so plumbing is not required. The drain lines and pan should be thoroughly
cleaned periodically as solids from spilled products may not evaporate, resulting in an unsanitary condition. Should the
drain become clogged, it should be cleaned with a small, round brush — do not use wire, as this may puncture the plastic
drain line.
• CLEANING
Wash or clean the cooler inside and out at regular intervals to preserve the nish and appearance. If stainless steel becomes discolored or stained, it should be cleaned with standard cleaners, but not with steel wool. CONDENSER COILS
MUST BE CLEANED AT REGULAR INTERVALS. FAILURE TO DO SO CAN CAUSE COMPRESSOR MALFUNCTION AND
WILL VOID WARRANTY. Clean condenser every 6 months, depending upon use, dust, etc. Clean as follows:
DW, SF, Models — Clean condenser as needed, depending upon use, dust, etc. Clean as follows: Remove front grill and
vacuum clean surfaces of condenser. (Alternate method for DW, SF, — Direct forced air through condenser from fan side.)