Product Data Sheet
VCPDS-16245-EN Rev. 3
February 2021
Bettis XTE3000
Electric Actuator
The XTE3000 is an intelligent, multi-turn electric actuator from the Bettis family of actuators. Specically designed to meet
the most challenging valve automation demands of the Oil and Gas, Power, and Process industries, the XTE3000 is compliant
with a wide range of international standards and is the ideal solution to your plant’s safety and reliability requirements.
Notes
February 2021
Product Data Sheet
VCPDS-16245-EN Rev. 3
This page is intentionally left blank
Product Data Sheet
VCPDS-16245-EN Rev. 3
Bettis XTE3000
February 2021
Table of Contents
Section 1: Actuator Models
General Information ...................................................................................................................... 1
Specications ................................................................................................................................ 1
Controls ........................................................................................................................................ 2
Standards and Directives ............................................................................................................... 3
Test Summary ............................................................................................................................... 4
Applicable Standards and Regulations ........................................................................................... 4
Section 2: Features and Functions of Actuators
Power Supply Three-Phase AC
Open-Close | Inching Duty ........................................................................................................... 5
S2-15’ | S4-25%, 60 St/h ............................................................................................................... 5
S2-30’ ........................................................................................................................................... 6
Modulating Duty .......................................................................................................................... 7
S4-25% 600 St/h ............................................................................................................................ 7
S4-50% 1200 St/h .......................................................................................................................... 8
Power Supply Single-Phase AC
Open-Close | Inching Duty ........................................................................................................... 9
S2-15’ | S4-25%, 60 St/h ............................................................................................................... 9
Modulating Duty ........................................................................................................................ 10
S4-50% 1200 St/h ........................................................................................................................ 10
Power Supply Direct Current
Modulating Duty ........................................................................................................................ 11
S4-25% 600 St/h .......................................................................................................................... 11
Section 3: Technical Data
Power Supply Three-Phase AC
Open-Close Duty ........................................................................................................................ 13
Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h) ........................................................ 13
Short-time Duty (S2-30’) ............................................................................................................. 13
Modulating Duty ......................................................................................................................... 14
Intermittent Periodic Duty (S4-25% - 600 St/h) ............................................................................ 14
Intermittent Periodic Duty (S4-50% - 1200 St/h) .......................................................................... 14
Power Supply Single-Phase AC
Open-Close Duty ........................................................................................................................ 15
Short-time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h) ........................................................ 15
Power Supply 220-240 V/50-60 Hz .............................................................................................. 15
Power Supply 110-120 V/50-60 Hz .............................................................................................. 15
Modulating Duty ......................................................................................................................... 16
Intermittent Periodic Duty (S4-5% - 1200 St/h) ............................................................................ 16
Power Supply 220-240 V/50-60 Hz .............................................................................................. 16
Power Supply 110-120 V/50-60 Hz .............................................................................................. 16
Power Supply Direct Current
Modulating Duty ........................................................................................................................ 17
Intermittent Periodic Duty (S4-25% - 600 St/h) ........................................................................... 17
Power Supply 24 V DC .................................................................................................................17
Power Supply 48 V DC .................................................................................................................17
Power Supply 110 V DC ............................................................................................................... 18
Power Supply 120 V DC ............................................................................................................... 18
I
Bettis XTE3000
February 2021
Product Data Sheet
VCPDS-16245-EN Rev. 3
Section 4: Electric Data
Three-Phase AC
Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h)
3PH-220 V (50 Hz) Power Supply ................................................................................................. 19
3PH-230 V (50 Hz) Power Supply ................................................................................................. 20
3PH-240 V (50 Hz) Power Supply ................................................................................................. 21
3PH-380 V (50 Hz) Power Supply ................................................................................................. 22
3PH-400 V (50 Hz) Power Supply ................................................................................................. 23
3PH-415 V (50 Hz) Power Supply ................................................................................................. 24
3PH-440 V (50 Hz) Power Supply ................................................................................................. 25
3PH-500 V (50 Hz) Power Supply ................................................................................................. 26
3PH-660 V (50 Hz) Power Supply ................................................................................................. 27
3PH-690 V (50 Hz) Power Supply ................................................................................................. 28
3PH-208 V (60 Hz) Power Supply ................................................................................................. 29
3PH-220 V (60 Hz) Power Supply ................................................................................................. 30
3PH-280 V (60 Hz) Power Supply ................................................................................................. 31
3PH-380 V (60 Hz) Power Supply ................................................................................................. 32
3PH-400 V (60 Hz) Power Supply ................................................................................................. 33
3PH-440 V (60 Hz) Power Supply ................................................................................................. 34
3PH-460 V (60 Hz) Power Supply ................................................................................................. 35
3PH-480 V (60 Hz) Power Supply ................................................................................................. 36
3PH-575 V (60 Hz) Power Supply ................................................................................................. 37
Intermittent Periodic Duty (S4-25%-600 St/h)
3PH-220 V (50 Hz) Power Supply .................................................................................................38
3PH-230 V (50 Hz) Power Supply .................................................................................................39
3PH-240 V (50 Hz) Power Supply .................................................................................................40
3PH-380 V (50 Hz) Power Supply .................................................................................................41
3PH-400 V (50 Hz) Power Supply .................................................................................................42
3PH-415 V (50 Hz) Power Supply .................................................................................................43
3PH-440 V (50 Hz) Power Supply .................................................................................................44
3PH-660 V (50 Hz) Power Supply .................................................................................................45
3PH-280 V (60 Hz) Power Supply .................................................................................................46
3PH-400 V (60 Hz) Power Supply .................................................................................................47
3PH-440 V (60 Hz) Power Supply .................................................................................................48
3PH-460 V (60 Hz) Power Supply .................................................................................................49
3PH-480 V (60 Hz) Power Supply .................................................................................................50
Intermittent Periodic Duty (S4-50%-1200 St/h)
3PH-220 V (50 Hz) Power Supply .................................................................................................51
3PH-230 V (50 Hz) Power Supply .................................................................................................52
3PH-240 V (50 Hz) Power Supply .................................................................................................53
3PH-380 V (50 Hz) Power Supply .................................................................................................54
3PH-400 V (50 Hz) Power Supply .................................................................................................55
3PH-415 V (50 Hz) Power Supply .................................................................................................56
3PH-440 V (50 Hz) Power Supply .................................................................................................57
3PH-280 V (60 Hz) Power Supply .................................................................................................58
3PH-400 V (60 Hz) Power Supply .................................................................................................59
3PH-440 V (60 Hz) Power Supply .................................................................................................60
3PH-460 V (60 Hz) Power Supply .................................................................................................61
3PH-480 V (60 Hz) Power Supply .................................................................................................62
Single-Phase AC
Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h) ........................................................ 63
1PH-110 V (50 Hz) Power Supply .................................................................................................63
1PH-115 V (50 Hz) Power Supply .................................................................................................63
1PH-220 V (50 Hz) Power Supply .................................................................................................63
II
Product Data Sheet
VCPDS-16245-EN Rev. 3
1PH-230 V (50 Hz) Power Supply .................................................................................................64
1PH-120 V (60 Hz) Power Supply .................................................................................................64
1PH-240 V (60 Hz) Power Supply .................................................................................................64
Intermittent Periodic Duty (S4-50% - 1200 St/h) .......................................................................... 65
1PH-110 V (50 Hz) Power Supply .................................................................................................65
1PH-115 V (50 Hz) Power Supply .................................................................................................65
1PH-220 V (50 Hz) Power Supply .................................................................................................65
1PH-230 V (50 Hz) Power Supply .................................................................................................66
1PH-120 V (60 Hz) Power Supply .................................................................................................66
1PH-240 V (60 Hz) Power Supply .................................................................................................66
Direct Current
Intermittent Periodic Duty (S4-25% - 600 St/h) ............................................................................ 67
24V DC Power Supply .................................................................................................................. 67
48V DC Power Supply .................................................................................................................. 67
110V DC Power Supply ................................................................................................................ 68
120V DC Power Supply ................................................................................................................ 68
Bettis XTE3000
February 2021
Section 5: Controls
Analog Module ............................................................................................................................ 69
Analog Position Transmission Module ......................................................................................... 69
Position Servoamplier Module ................................................................................................... 69
Bus Controls Modules .................................................................................................................. 69
FOUNDATION
HART 7 ........................................................................................................................................ 69
Modbus RTU ................................................................................................................................70
Probus DP..................................................................................................................................70
LonWorks .................................................................................................................................... 70
TM
Fieldbus .............................................................................................................69
Section 6: Overall Actuator Dimensions
Overall Dimensions - Standard Manual Override .......................................................................... 71
Dimension Table.......................................................................................................................... 71
Overall Dimensions - Optional Probus Module with Standard Manual Override .......................... 72
Dimension Table.......................................................................................................................... 72
Overall Dimensions - Reduced Manual Override ........................................................................... 73
Dimension Table.......................................................................................................................... 73
Overall Dimensions - Optional Probus Module with Reduced Manual Override...........................74
Dimension Table.......................................................................................................................... 74
Section 7: Output Drive Dimensions
Output Drive Type A Dimensions ................................................................................................. 75
Thrust Block Assembly ................................................................................................................75
Output Drive Type B4 Dimensions ............................................................................................... 76
Thrust Block Type B4 ................................................................................................................... 76
Output Drive Type B6 Dimensions ............................................................................................... 77
Thrust Block Type B6 ................................................................................................................... 77
Output Drive Type B8 Dimensions ............................................................................................... 78
Thrust Block Type B8 ................................................................................................................... 78
Section 8: Spare Parts List
XTE Spare Parts List ..................................................................................................................... 79
Section 9: Wiring Diagram Code
Wiring Diagram Code.....................................................................................................................80
III
Bettis XTE3000
February 2021
Product Data Sheet
VCPDS-16245-EN Rev. 3
Actuator Models
General Information
General Non-intrusive intelligent multi-turn electric actuator
Starter Integrated
Specications
Enclosure Aluminum alloy highly resistant to corrosion, with few joints.
The enclosure includes logic circuit boards, power boards, reversing contactor, non-intrusive local interface with
three push-buttons (for open, stop, and close control and actuator conguration), LED indicators (yellow, green
Control Enclosure
Lubrication Lubricated in a hydraulic oil bath for the entire duration of the actuator's service life.
Manual Operation
Torque and Position sensor
Bypass Torque
Diagnostics
2_ Speed_Timer Software routine to extend the actuator travelling time in opening and/or in closing direction.
Monitor Relay
Remote Output Contacts Eight (8) voltage-free latching contacts are available for remote indication.
Terminal Board Double-sealed for maximum protection.
Heater Included
Paint Finish
Actuator Nameplate In stainless steel, complete with all the actuator's relevant characteristics. Nameplates in English language.
Cable Entry Points
and red), and selector with local, remote, and off positions.
Standard features included are: Automatic Phase Correction, Phase Failure Detection, Anti-hammer Protection,
Jammed Valve Protection, Instantaneous Reversal Protection, ESD, Contactor Failure, Electronic Temperature
Warming, Electronic Nameplate, Timer, Double Displays.
Handwheel and lockable engagement lever, painted black, with automatic de-clutch when the motor starts;
the handwheel will not rotate during the electric operation.
High-precision and high-resolution torque sensor. Torque detection is based on motor torque vs. speed characteristics, voltage and temperature compensated. Position sensors based on absolute encoder, controlled by a
dedicated microprocessor with low power consumption. The Limit Position can be adjusted from 0% to 100% of
the open position. The Output Torque can be adjusted from 40% to 100% of the nominal torque.
Torque intervention bypass time function allows the actuator to output its maximum torque at the beginning of
the stroke, with a bypass time congurable from 0 % to 20%.
Data logger, warnings and alarm diagnostic messages available on local display or remotely transmitted,
for high efciency preventive maintenance programs and actuator status control.
Instantaneous and historical data available.
One (1) contact signal to indicate when the actuator is not available for remote control due to one or more of the
ALARM conditions.
Typ e Procedure Typical Environments
Standard
Special
Standard NPT
Option NPT nr 2 x 3/4”
Corrosion category protection C4
(EN12944-2) Highly Durability
Corrosion category protection C5
(EN12944-2) High Durability
Industrial areas and coastal areas with moderate salinity.
Industrial areas with high humidity and aggressive atmosphere,
and Coastal and offshore areas with high salinity.
nr 2 x 1”
nr 1 x 1 ½”
1
Product Data Sheet
VCPDS-16245-EN Rev. 3
Controls
Bettis XTE3000
February 2021
Local Controls
LEDs
Bluetooth
Remote Control
Control Voltage/Control Inputs
Remote Output Contacts
Interlock Controls Two interlock inputs are available to inhibit actuator movement in open or closed direction
Emergency Shutdown (ESD)
Monitor Relay
Intelligent Protection
A padlock-able LOCAL/OFF/REMOTE selector switch and OPEN/STOP/CLOSE push-buttons are included for local
control of the valve.
LED colours:
green = open / opening
red = close / closing
yellow = alarm / warning
blue = Bluetooth port active
LED colours can be easily changed via the local control interface.
Bluetooth port included for easy wireless conguration, diagnostics, and control via a PC with
Emerson DCMlink software.
4 wires (OP, CL, Stop, C/latched)
3 wires (OP, CL, C/push-to-run or latched with instant reverse)
2 wires (NO contact to open or reverse)
24 V DC, internal supply
not regulated
max 4 W
Status
Open limit
Closed limit
Position >=xx %
Position <=xx %
Closing
Opening
Motor running blinker
Mid-travel position
Local selected
Remote selected
Local stop active
ESD signal on
Manual operation
Emergency shut-down (ESD) command makes the actuator perform the relevant programmed action
(requires power supply)
Selector in LOCAL
Selector in OFF
Motor temperature alarm
Local STOP pushbutton
Torque alarm
Loss of power
Loss of one phase
Electrical contactor failure
Local stop activated
Local selector switch in LOCAL/OFF
Internal temperature alarm
Position sensor
Hardware error
Automatic phase correction
Phase failure correction
Motor thermostat
Jammed valve protection
Anti-hammer protection
Instantaneous reversal protection
20 to 125 V DC, external supply
20 to 120 V AC, external supply
max 25 mA
Alarms
Motor over-temperature
Over-torque over torque in OP
Over-torque in CL
Valve jammed in OP
Valve jammed in CL
Valve jammed
Warnings
Low lithium battery (if present)
Mid-travel alarm in CL/OP
Mains-only AS8
2 speed timer
Stay put
Move to open position
Move to close position
Move to preset position
Motor temperature alarm
Torque alarm
Jammed valve
Mid-travel alarm
Speed sensor conguration error
Manual operation
ESD signal
Low battery
Warnings
Contactor failure
Maximum torque alarm
Torque alarm bypass
High/low electronic temperature
Opto-coupled remote controls
2
Bettis XTE3000
February 2021
Upper Display LCD numeric | 3 ½ digit | shows the current valve position as a percentage
Lower Display OLED graphic | 128 x 64 dots | (yellow monochromatic)
Multiple Languages
Battery
Standards and Directives
Products have been certied in accordance with the following directives:
— India - C.C.O.E.
— International – IECEx
— FM-c
— China – NEPSI
— USA – FM
— SIL 2/3
— Korea – KOSHA
— Brazil – INMETRO
— EAC CoC (CU-TR)
Possible to choose from the following languages: English, Italian, German, French, Portuguese, Spanish, Russian,
Turkish, Norwegian
- Local position display active (LCD 3 1/2 digit)
- Real-time clock (Back-up)
Option A [9V lithium battery included]
Option B [No Battery]
- 4-20 mA positioner and relays active
Above functionality is also available when
MAIN POWER SUPPLY OFF
- Local position display active (LCD 3 1/2 digit)
- Real-time clock
- 4-20 mA positioner and Relays active
Above functionality is available only when
MAIN POWER SUPPLY ON
Product Data Sheet
VCPDS-16245-EN Rev. 3
3
Product Data Sheet
VCPDS-16245-EN Rev. 3
Bettis XTE3000
February 2021
Test Summary
Vibration Test
— XTE3000 is certied as per IEC 60068-2-6- Appendix B (plant induced): frequencies from 1 to 500 Hz (in 3 axes) with 2.0 g
peak acceleration. Sweep cycles in each axis: 10.
Seismic Test
— XTE3000 is tested in accordance with IEC 60068-2-57. Frequencies from 1 to 35 Hz (in 3 axes) with max 2.0 g peak
acceleration. Verication of structural integrity at 5 g. Endurance of oscillogram: 30 seconds.
Salt Spray Test
— XTE3000 external coating is tested for resistance to salt spray for 1,500 hours according to ASTM B117/IEC 68-2-11.
Noise Test
— XTE3000 is tested according to EN ISO 1680. Noise level is less than 65 dB (grade A) at 1 m distance.
Applicable Standards and Regulations
Electromagnetic compatibility directive (EMC)
— XTE3000 actuators conform to the requirements of EMC Directive 2014/30/EU.
Low voltage directive (LV)
— XTE3000 actuators comply with Low Voltage Directive 2014/35/EU.
Machinery directive
— XTE3000 actuators comply with the provision of Machinery Directive 2006/42/EC.
RED directive
— XTE3000 actuators comply with the RED Directive 2014/53/EU.
ATEX directive
— XTE3000 actuators comply with the ATEX Directive 2014/34/EU.
4
Bettis XTE3000
February 2021
Features and Functions of Actuators
Power Supply Three-Phase AC
Open-Close | Inching Duty
S2-15’ | S4-25%, 60 St/h
220 230 240 380 400 415 AC Volt
Voltage/frequency
Special
Voltage/frequency
Type of Duty
Insulation Class Standard Class H
50 50 50 50 50 50 Hz
280 440 460 480 AC Volt
60 60 60 60 Hz
440 500 660 690 AC Volt
50 50 50 50 Hz
208 220 380 400 575 AC Volt
60 60 60 60 60 Hz
Standard S2-15’ | S4-25%, 60 St/h Class A and B according to EN15714-2
In accordance with IEC 60034_1
Product Data Sheet
VCPDS-16245-EN Rev. 3
Table A
Short time duty | Intermittent duty
S2-15' | S4-25%, 60 St/h
Waterproof IIB IIC
Div IIB IIC IIB IIC
3ph
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 85 -20 -60 85 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
FM-US FM-C
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIB Gb T4
Tmin Tmax
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIC Gb T4
Tmin Tmax
Tmin
(STD)
Tmin Tmax
FM - Ex db IIB Gb T4
Tmin
(STD)
FM - Ex db IIC Gb T4
Tmin Tmax
XTE_020 -20 -60 85 -20 -60 85 -20 -60 85 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_030 -20 -60 85 -20 -55 85 -20 -25 70 -20 -50 70 -20 -50 70
XTE_040 -20 -60 85 -20 -55 85 -20 -25 70 -20 -50 70 -20 -50 70
XTE_050 -20 -60 85 -20 -55 85 -20 -25 70 -20 -50 70 -20 -50 70
5
Product Data Sheet
VCPDS-16245-EN Rev. 3
Power Supply Three-Phase AC
Open-Close
S2-30’
220 230 240 380 400 415 AC Volt
Voltage/frequency
Special
Voltage/frequency
Type of Duty
Insulation Class Standard Class H
50 50 50 50 50 50 Hz
280 440 460 480 AC Volt
60 60 60 60 Hz
440 660 AC Volt
50 50 Hz
Standard S2-30’ | Class A and B according to EN15714-2
In accordance with IEC 60034_1
Bettis XTE3000
February 2021
400 AC Volt
60 Hz
Table B
Short time duty
S2-30'
Waterproof IIB IIC
Div IIB IIC IIB IIC
3ph
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
FM-US FM-C
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIB Gb T4
Tmin Tmax
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIC Gb T4
Tmin Tmax
Tmin
(STD)
Tmin Tmax
FM - Ex db IIB Gb T4
Tmin
(STD)
FM - Ex db IIC Gb T4
Tmin Tmax
XTE_020 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_030 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
XTE_040 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
XTE_050 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
6
Bettis XTE3000
February 2021
Power Supply Three-Phase AC
Inching Duty
S4-25% 600 St/h
220 230 240 380 400 415 AC Volt
Voltage/frequency
Special
Voltage/frequency
Type of Duty
Insulation Class Standard Class H
50 50 50 50 50 50 Hz
280 440 460 480 AC Volt
60 60 60 60 Hz
440 660 AC Volt
50 50 Hz
Standard S4-25% 600 St/h, Class C according to EN15714-2
In accordance with IEC 60034_1
Product Data Sheet
VCPDS-16245-EN Rev. 3
400 AC Volt
60 Hz
Table C
Intermittent Duty
S4-25%, 600 St/h
Waterproof IIB IIC
Div IIB IIC IIB IIC
3ph
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
FM-US FM-C
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIB Gb T4
Tmin Tmax
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIC Gb T4
Tmin Tmax
Tmin
(STD)
Tmin Tmax
FM - Ex db IIB Gb T4
Tmin
(STD)
FM - Ex db IIC Gb T4
Tmin Tmax
XTE_020 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_030 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
XTE_040 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
XTE_050 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
7
Product Data Sheet
VCPDS-16245-EN Rev. 3
Power Supply Three-Phase AC
Modulating Duty
S4-50% 1200 St/h
220 230 240 380 400 415 AC Volt
Voltage/frequency
Special
Voltage/frequency
Type of Duty
Insulation Class Standard Class H
50 50 50 50 50 50 Hz
280 440 460 480 AC Volt
60 60 60 60 Hz
440 AC Volt
50 Hz
Standard S4-50% 1200 St/h, Class C according to EN15714-2
In accordance with IEC 60034_1
Bettis XTE3000
February 2021
400 AC Volt
60 Hz
Table D
Modulating duty
S4-50%, 1200 St/h
Waterproof IIB IIC
Div IIB IIC IIB IIC
3ph
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
FM-US FM-C
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIB Gb T4
Tmin Tmax
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIC Gb T4
Tmin Tmax
Tmin
(STD)
Tmin Tmax
FM - Ex db IIB Gb T4
Tmin
(STD)
FM - Ex db IIC Gb T4
Tmin Tmax
XTE_020 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_030 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
XTE_040 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
XTE_050 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
8
Bettis XTE3000
February 2021
Power Supply Single-Phase AC
Open-Close | Inching Duty
S2-15’ | S4-25%, 60 St/h
220 230 AC Volt
Voltage/frequency
Special
Voltage/frequency
Type of Duty
Insulation Class Standard Class H
50 50 Hz
240 AC Volt
60 Hz
110 115 AC Volt
50 50 Hz
120 AC Volt
60 Hz
Standard S2-15’ | S4-25%, 60 St/h, Class A and B according to EN15714-2
In accordance with IEC 60034_1
Product Data Sheet
VCPDS-16245-EN Rev. 3
Table E
Short time duty | Intermittent duty
S2-15' | S4-25%, 60 St/h
Waterproof IIB IIC
Div IIB IIC IIB IIC
1ph
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
FM-US FM-C
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIB Gb T4
Tmin Tmax
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIC Gb T4
Tmin Tmax
Tmin
(STD)
Tmin Tmax
FM - Ex db IIB Gb T4
Tmin
(STD)
FM - Ex db IIC Gb T4
Tmin Tmax
XTE_020 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_030 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
9
Product Data Sheet
VCPDS-16245-EN Rev. 3
Power Supply Single-Phase AC
Modulating Duty
S4-50% 1200 St/h
220 230 AC Volt
Voltage/frequency
Special
Voltage/frequency
Type of Duty
Insulation Class Standard Class H
50 50 Hz
240 AC Volt
60 Hz
110 115 AC Volt
50 50 Hz
120 AC Volt
60 Hz
Standard S4-50% 1200 St/h, Class C according to EN15714-2
In accordance with IEC 60034_1
Bettis XTE3000
February 2021
Table F
Modulating duty
S4-50%, 1200 St/h
Waterproof IIB IIC
Div IIB IIC IIB IIC
1ph
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
FM-US FM-C
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIB Gb T4
Tmin Tmax
Tmin
(STD)
FM - Cl. I, Zn 1, AEx db IIC Gb T4
Tmin Tmax
Tmin
(STD)
Tmin Tmax
FM - Ex db IIB Gb T4
Tmin
(STD)
FM - Ex db IIC Gb T4
Tmin Tmax
XTE_020 -20 -60 85 -20 -60 65 -20 -60 65 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_030 -20 -60 85 -20 -55 65 -20 -25 70 -20 -50 70 -20 -50 70
10
Bettis XTE3000
February 2021
Power Supply Direct Current
Inching Duty
S4-25% 600 St/h
24 48 DC Volt
Voltage/frequency
110 120 DC Volt
Special
Voltage/frequency
Product Data Sheet
VCPDS-16245-EN Rev. 3
Type of Duty
Standard S4-25% 600 St/h, Class C according to EN15714-2
In accordance with IEC 60034_1
Insulation Class Standard Class H
Table G
Short Time Duty | Intermittent Duty
S2-15' | S4-25%, 60 St/h | S4-25%, 600 St/h
Waterproof IIB IIC
DC
FM-US FM-C
Div IIB IIC IIB IIC
IP66 / IP68 EN60529
NEMA 250 4, 4X, 6
II 2 GD - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIB T4 Gb - Ex tb IIIC T135 C Db
KOSHA - Ex d IIB T4 Gb
CCOE - Ex db h IIB T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIB T4 Gb X - Ex tb IIIC T135 C Db
II 2 GD - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
IECEx - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
INMETRO - Ex db IIC T4 Gb - Ex tb IIIC T135 C Db
CCOE - Ex db h IIC T4 Gb - Ex h tb IIIC T135 C Db
EAC - 1Ex d IIC T4 Gb X - Ex tb IIIC T135 C Db
FM - Cl. I, Div. 1 Grp C and D T4A/T4; Cl. II, Div.
1/2 Grp E, F and G T4A/T4; Cl. III, Div. 1/2 T4A/T4
FM - Cl. I, Zn 1, AEx db IIB Gb T4
FM - Cl. I, Zn 1, AEx db IIC Gb T4
FM - Ex db IIB Gb T4
FM - Ex db IIC Gb T4
Temperature range (°C)
Tmin
(STD)
Tmin Tmax
Tmin
Tmin Tmax
(STD)
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
Tmin
(STD)
Tmin Tmax
XTE_010 -20 -60 85 -20 -60 +65 or +85 -20 -60 +65 or +85 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
XTE_020 -20 -60 85 -20 -60 +65 or +85 -20 -60 +65 or +85 -20 -40 70 -20 -50 70 -20 -50 70 -20 -50 70 -20 -50 70
11
Product Data Sheet
VCPDS-16245-EN Rev. 3
Technical Data
Actuator model description is dened by the following coding:
XTE xx / yyyy - zzz
Typ e Size Torque Speed
XTE 3000 Product family
Size 010/020/030/040/050 Model size
Torque 30/90/180/360/720/1440 Output nominal torque Nm
Speed 12/18/24/36/48/72/144 (50 Hz) Output speed RPM
14/22/29/43/58/86/173 (60 Hz)
Model Description Example XTE_010/90-24
Bettis XTE3000
February 2021
12
Bettis XTE3000
February 2021
Technical Data for Multi-Turn Actuators
Power Supply Three-Phase AC
Open-Close Duty
Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h)
Product Data Sheet
VCPDS-16245-EN Rev. 3
Typ e Torque Range
XTE 010 12 (9) 30 (22) 45 (33) SM00 SM01 SM10 SM11 SM04 SM05 SM06
XTE 010 36 (27) 90 (66) 135 (100) SM10 SM11 SM12 SM13 SM14 SM15 SM16
XTE 020 72 (53) 180 (133) 270 (199) SM13 SM14 SM15 SM21 SM22 SM23
XTE 030 144 (106) 360 (266) 540 (398) SM21 SM32 SM21 SM30 SM23 SM31
XTE 040 288 (212) 720 (531) 1080 (797) SM30 SM44 SM30 SM40 SM41 SM31 SM42
XTE 050 576 (425) 1440 (1062) 2160 (1593) SM41 SM40 SM41 SM43 SM50 SM42 SM51
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. SMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max 12 18 24 36 48 72 144 50
14 22 29 43 58 86 173 60
Nm (lb.ft) Hz
(4)
Operating Speed [RPM]/Motor Type
Short-time Duty (S2-30’)
Typ e Torque Range
XTE 010 12 (9) 30 (22) 45 (33) TM00 TM01 TM10 TM11 TM04 TM05 TM06
XTE 010 36 (27) 90 (66) 135 (100) TM10 TM11 TM12 TM13 TM14 TM15 TM16
XTE 020 72 (53) 180 (133) 270 (199) TM13 TM14 TM15 TM21 TM22 TM23
XTE 030 144 (106) 360 (266) 540 (398) TM21 TM30 TM23 TM31
XTE 040 288 (212) 720 (531) 1080 (797) TM30 TM40 TM31
XTE 050 576 (425) 1440 (1062) 2160 (1593)
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max 12 18 24 36 48 72 144 50
14 22 29 43 58 86 173 60
Nm (lb.ft) Hz
(4)
Operating Speed [RPM]/Motor Type
13
Product Data Sheet
VCPDS-16245-EN Rev. 3
Bettis XTE3000
February 2021
Technical Data for Multi-Turn Actuators
Power Supply Three-Phase AC
Modulating Duty
Intermittent Periodic Duty (S4-25% - 600 St/h)
Typ e Torque Range
XTE 010 12 (9) 30 (22) 45 (33) TM00 TM01 TM10 TM11 TM04 TM05 TM06
XTE 010 36 (27) 90 (66) 135 (100) TM10 TM11 TM12 TM13 TM14 TM15 TM16
XTE 020 72 (53) 180 (133) 270 (199) TM13 TM14 TM15 TM21 TM22 TM23
XTE 030 144 (106) 360 (266) 540 (398) TM21 TM30 TM23 TM31
XTE 040 288 (212) 720 (531) 1080 (797) TM30 TM40 TM31
XTE 050 576 (425) 1440 (1062) 2160 (1593)
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max 12 18 24 36 48 72 144 50
14 22 29 43 58 86 173 60
Nm (lb.ft) Hz
(4)
Operating Speed [RPM]/Motor Type
Intermittent Periodic Duty (S4-50% - 1200 St/h)
Typ e Torque Range
Nm (lb.ft) Hz
min nom. max 12 18 24 36 48 72 144 50
14 22 29 43 58 86 173 60
XTE 010 12 (9) 30 (22) 45 (33) TM00 TM01 TM10 TM11 TM04 TM05
XTE 010 36 (27) 90 (66) 135 (100) TM10 TM11 TM12 TM13 TM14 TM15
XTE 020 72 (53) 180 (133) 270 (199) TM13 TM14 TM15 TM21 TM22
XTE 030 144 (106) 360 (266) 540 (398) TM21 TM30
XTE 040 288 (212) 720 (531) 1080 (797) TM30
XTE 050 576 (425) 1440 (1062) 2160 (1593)
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
(4)
Operating Speed [RPM]/Motor Type
14
Bettis XTE3000
February 2021
Technical Data for Multi-Turn Actuators
Power Supply Single-Phase AC
Open-Close Duty
Short-time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h)
Power Supply 220-230-240 V/50-60 Hz
Typ e Torque Range
(4)
Product Data Sheet
VCPDS-16245-EN Rev. 3
Operating Speed [RPM]/Motor Type
XTE 010 12 (9) 30 (22) 45 (33) 8 17 TM11
XTE 010 12 (9) 30 (22) 45 (33) 24 72 TM15
XTE 010 12 (9) 30 (22) 45 (33) 73 172 TM16
XTE 010 36 (27) 90 (66) 135 (100) 6 23 TM13
XTE 010 36 (27) 90 (66) 135 (100) 24 95 TM18
XTE 010 36 (27) 90 (66) 135 (100) 96 120 TM16
XTE 020 72 (53) 180 (133) 270 (199) 12 36 TM22
XTE 020 72 (53) 180 (133) 270 (199) 48 60 TM22
XTE 030 144 (106) 360 (266) 540 (398) 10 30 TM30
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
Power Supply 110-115-120 V/50-60 Hz
Typ e Torque Range
(4)
Operating Speed [RPM]/Motor Type
XTE 010 12 (9) 30 (22) 45 (33) 8 17 TM11
XTE 010 12 (9) 30 (22) 45 (33) 18 62 TM14
XTE 010 12 (9) 30 (22) 45 (33) 63 94 TM15
XTE 010 36 (27) 90 (66) 135 (100) 6 23 TM13
XTE 010 36 (27) 90 (66) 135 (100) 24 40 TM14
XTE 020 72 (53) 180 (133) 270 (199) 8 20 TM21
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
15
Product Data Sheet
VCPDS-16245-EN Rev. 3
Modulating Duty
Intermittent Periodic Duty (S4-5% - 1200St/h)
Power Supply 220-230-240 V/50-60 Hz
Typ e Torque Range
Bettis XTE3000
February 2021
(4)
Operating Speed [RPM]/Motor Type
XTE 010 12 (9) 30 (22) 45 (33) 8 17 TM11
XTE 010 12 (9) 30 (22) 45 (33) 24 72 TM15
XTE 010 12 (9) 30 (22) 45 (33) 73 172 TM16
XTE 010 36 (27) 90 (66) 135 (100) 6 23 TM13
XTE 020 72 (53) 180 (133) 270 (199) 12 36 TM22
XTE 020 72 (53) 180 (133) 270 (199) 48 60 TM22
XTE 030 144 (106) 360 (266) 540 (398) 10 30 TM30
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
Power Supply 110-115-120 V/50-60 Hz
Typ e Torque Range
(4)
Operating Speed [RPM]/Motor Type
XTE 010 12 (9) 30 (22) 45 (33) 8 17 TM11
XTE 010 12 (9) 30 (22) 45 (33) 18 62 TM14
XTE 010 12 (9) 30 (22) 45 (33) 63 94 TM15
XTE 010 36 (27) 90 (66) 135 (100) 6 23 TM13
XTE 010 36 (27) 90 (66) 135 (100) 24 40 TM14
XTE 020 72 (53) 180 (133) 270 (199) 8 20 TM21
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. TMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
16
Bettis XTE3000
February 2021
Technical Data for Multi-turn Actuators
Power Supply Direct Current
Modulating Duty
Intermittent Periodic Duty (S4-25% - 600 St/h)
Power Supply 24 V DC
Typ e Torque Range
(4)
Product Data Sheet
VCPDS-16245-EN Rev. 3
Operating Speed [RPM]/Motor Type
XTE 010 12 (9) 30 (22) 45 (33) 12 29 DM05d
XTE 010 12 (9) 30 (22) 45 (33) 30 60 DM05d
XTE 010 36 (27) 90 (66) 135 (100) 12 30 DM05
XTE 010 36 (27) 90 (66) 135 (100) 50 68 DM05
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. DMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
Power Supply 48 V DC
Typ e Torque Range
XTE 010 12 (9) 30 (22) 45 (33) 12 29 DM05d
XTE 010 12 (9) 30 (22) 45 (33) 30 60 DM05d
XTE 010 36 (27) 90 (66) 135 (100) 12 30 DM05
XTE 010 36 (27) 90 (66) 135 (100) 50 68 DM05
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. DMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
(4)
Operating speed [RPM]/Motor type
17
Product Data Sheet
VCPDS-16245-EN Rev. 3
Power Supply 110 V DC
Typ e Torque Range
Bettis XTE3000
February 2021
(4)
Operating Speed [RPM]/Motor Type
XTE 010 12 (9) 30 (22) 45 (33) 12 29 DM05d
XTE 010 12 (9) 30 (22) 45 (33) 30 80 DM05d
XTE 010 36 (27) 90 (66) 135 (100) 20 40 DM05
XTE 010 36 (27) 90 (66) 135 (100) 55 70 DM05
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. DMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
Power Supply 120 V DC
Typ e Torque Range
XTE 010 12 (9) 30 (22) 45 (33) 12 29 DM05d
XTE 010 12 (9) 30 (22) 45 (33) 30 80 DM05d
XTE 010 36 (27) 90 (66) 135 (100) 20 40 DM05
XTE 010 36 (27) 90 (66) 135 (100) 55 70 DM05
XTE 020 72 (53) 180 (133) 270 (199) 35 37 DM05
1. Handwheel diameter Refer to the Overall Actuator Dimensions section of this document.
2. Valve connection Refer to the Output Drive Dimensions section of this document.
3. Weight Refer to the Overall Actuator Dimensions section of this document.
4. Output torque Adjustable in OPEN and in CLOSED direction from min. to nom. values.
5. Electric data actuator Refer to the Electric Data section of this document with reference to the Power supply and Motor type.
6. DMxx Code of the electric motor applied to the actuator model.
See the relevant table for Electric performance.
min nom. max from to
Nm (lb.ft)
(4)
Operating speed [RPM]/Motor type
18
Bettis XTE3000
February 2021
Electric Data
Three-Phase AC
Short-Time Duty (S2-15’) | Inching Duty (S4-25% |60 St/h)
3-ph 220 V 50 Hz
Product Data Sheet
VCPDS-16245-EN Rev. 3
Size, Torque, Speed RPM Motor
XTE_010/30-12 12 SM00 40 0.03 0.04 0.8 0.9 1.1 0.46 0.14 0.19 23.10
XTE_010/30-18 18 SM01 40 0.05 0.07 0.8 1.0 1.4 0.42 0.13 0.17 38.30
XTE_010/30-24 24 SM10 20 0.07 0.10 2.6 3.0 4.3 0.43 0.43 0.57 17.30
XTE_010/30-36 36 SM11 20 0.11 0.15 2.6 2.9 5.0 0.43 0.43 0.57 25.90
XTE_010/30-48 48 SM04 20 0.15 0.19 2.4 4.3 5.0 0.47 0.43 0.58 33.80
XTE_010/30-72 72 SM05 20 0.22 0.29 2.2 4.6 7.8 0.56 0.47 0.63 46.30
XTE_010/30-144 144 SM06 20 0.43 0.58 3.1 4.5 10.8 0.71 0.84 1.12 51.30
XTE_010/90-12 12 SM10 40 0.07 0.10 2.6 3.0 4.3 0.43 0.43 0.57 17.30
XTE_010/90-18 18 SM11 40 0.11 0.15 2.6 2.9 5.0 0.43 0.43 0.57 25.90
XTE_010/90-24 24 SM12 20 0.12 0.17 3.5 3.7 5.0 0.46 0.61 0.82 20.30
XTE_010/90-36 36 SM13 20 0.19 0.25 3.6 4.6 6.3 0.41 0.56 0.75 32.90
XTE_010/90-48 48 SM14 20 0.29 0.39 3.1 3.7 9.2 0.46 0.54 0.73 53.00
XTE_010/90-72 72 SM15 20 0.37 0.49 3.8 5.3 13.3 0.55 0.80 1.07 45.90
XTE_010/90-144 144 SM16 20 0.74 0.99 5.1 8.5 22.6 0.67 1.30 1.74 57.00
XTE_020/180-18 18 SM13 40 0.19 0.25 3.6 4.6 6.3 0.41 0.56 0.75 32.90
XTE_020/180-24 24 SM14 40 0.29 0.39 3.1 3.7 9.2 0.46 0.54 0.73 53.00
XTE_020/180-36 36 SM15 40 0.37 0.49 3.8 5.3 13.3 0.55 0.80 1.07 45.90
XTE_020/180-48 48 SM21 20 0.53 0.71 5.1 8.5 14.1 0.43 0.84 1.12 63.40
XTE_020/180-72 72 SM22 20 0.78 1.05 5.6 11.0 21.0 0.61 1.30 1.74 60.20
XTE_020/180-144 144 SM23 20 1.48 1.98 9.3 15.1 42.4 0.67 2.37 3.18 62.30
XTE_030/360-12 12 SM21 80 0.53 0.71 5.1 8.5 14.1 0.43 0.84 1.12 63.40
XTE_030/360-18 18 SM32 40 0.50 0.67 5.6 7.3 15.1 0.39 0.83 1.12 60.20
XTE_030/360-24 24 SM21 40 0.53 0.71 5.1 8.5 14.1 0.43 0.84 1.12 63.40
XTE_030/360-48 48 SM30 20 1.13 1.51 10.9 18.3 32.6 0.43 1.79 2.39 63.10
XTE_030/360-72 72 SM23 40 1.48 1.98 9.3 15.1 42.4 0.67 2.37 3.18 62.30
XTE_030/360-144 144 SM31 20 3.38 4.53 15.5 31.8 90.8 0.68 4.02 5.38 84.20
XTE_040/720-12 12 SM30 80 1.13 1.51 10.9 18.3 32.6 0.43 1.79 2.39 63.10
XTE_040/720-18 18 SM44 40 0.84 1.12 7.8 13.2 21.6 0.39 1.16 1.55 72.40
XTE_040/720-24 24 SM30 40 1.13 1.51 10.9 18.3 32.6 0.43 1.79 2.39 63.10
XTE_040/720-36 36 SM40 40 1.69 2.26 10.9 21.7 50.9 0.67 2.78 3.73 60.60
XTE_040/720-48 48 SM41 20 1.95 2.61 13.3 27.0 44.9 0.49
XTE_040/720-72 72 SM31 40 3.38 4.53 15.5 31.8 90.8 0.68 4.02 5.38 84.20
XTE_040/720-144 144 SM42 20 5.82 7.80 27.8 56.4 141.4 0.73 7.73 10.36 75.30
XTE_050/1440-12 12 SM41 80 1.95 2.61 13.3 27.0 44.9 0.49 2.48 3.33 78.50
XTE_050/1440-18 18 SM40 80 1.69 2.26 10.9 21.7 50.9 0.67 2.78 3.73 60.60
XTE_050/1440-24 24 SM41 40 1.95 2.61 13.3 27.0 44.9 0.49 2.48 3.33 78.50
XTE_050/1440-36 36 SM43 40 2.89 3.87 16.2 31.8 74.0 0.56 3.46 4.63 83.60
XTE_050/1440-48 48 SM50 20 3.88 5.20 19.8 36.1 114.0 0.61 4.60 6.17 84.30
XTE_050/1440-72 72 SM42 40 5.82 7.80 27.8 56.4 141.4 0.73 7.73 10.36 75.30
XTE_050/1440-144 144 SM51 20 11.66 15.62 48.9 106.9 325.2 0.71 13.23 17.73 88.10
Notes:
Due to manufacturing tolerances there may be deviations from the published values.
1. Voltage tolerance value: -10% / +10%; Frequency tolerance value: -2% / +2%. If the voltage and frequency drops below above tolerances the actuator performances
cannot be guaranteed.
2. Power [KW] = Nominal Motor Output Power according to IEC 60034-1 is the mechanical power output at motor shaft at run torque of multi-turn actuator
(at approx. 40% of actuator nominal torque)
3. In (A) = (I-40%) = Motor current at approx. 40% of actuator nominal torque.
4. Is (A) = (I-100%) = Motor current at approx. 100% of actuator nominal torque.
5. Icc (A) =Locked rotor current.
6. Power Factor - Cosφ nom = (Cosφ 40%) = Power factor at approx. 40% of actuator nominal torque.
7. Absorbed Power [KW] = Absorbed electrical Power at approx. 40% of actuator nominal torque.
8. Nominal Duty S2-15' or S4-25% 60 starts/hours according to IEC 60034-1. Motor insulation: Class H. Tolerances on the published values according to IEC 60034-1.
INT WG
Ratio (:1)
Power
(KW)
Power
(HP)
In (A) Is (A) Icc (A)
Power
Factor
Absorbed
Power (KW)
2.48 3.33 78.50
Absorbed
Power (HP)
Efciency
(%)
19
Product Data Sheet
VCPDS-16245-EN Rev. 3
3-ph 230 V 50 Hz
Bettis XTE3000
February 2021
Size, Torque, Speed RPM Motor
XTE_010/30-12 12 SM00 40 0.03 0.04 0.7 0.8 1.1 0.46 0.13 0.17 23.10
XTE_010/30-18 18 SM01 40 0.05 0.07 0.8 1.0 1.5 0.42 0.13 0.18 38.30
XTE_010/30-24 24 SM10 20 0.07 0.10 2.4 3.0 4.5 0.43 0.41 0.55 17.30
XTE_010/30-36 36 SM11 20 0.11 0.14 2.4 2.8 5.2 0.43 0.41 0.55 25.90
XTE_010/30-48 48 SM04 20 0.15 0.20 2.3 4.2 5.2 0.47 0.43 0.58 33.80
XTE_010/30-72 72 SM05 20 0.22 0.29 2.1 4.5 8.2 0.56 0.47 0.63 46.30
XTE_010/30-144 144 SM06 20 0.44 0.58 3.0 4.4 11.3 0.71 0.85 1.14 51.30
XTE_010/90-12 12 SM10 40 0.07 0.10 2.4 3.0 4.5 0.43 0.41 0.55 17.30
XTE_010/90-18 18 SM11 40 0.11 0.14 2.4 2.8 5.2 0.43 0.41 0.55 25.90
XTE_010/90-24 24 SM12 20 0.12 0.16 3.3 3.7 5.2 0.46 0.60 0.81 20.30
XTE_010/90-36 36 SM13 20 0.19 0.25 3.5 4.5 6.6 0.41 0.57 0.77 32.90
XTE_010/90-48 48 SM14 20 0.29 0.39 3.0 3.7 9.6 0.46 0.55 0.74 53.00
XTE_010/90-72 72 SM15 20 0.37 0.50 3.7 5.2 13.9 0.55 0.81 1.09 45.90
XTE_010/90-144 144 SM16 20 0.74 0.99 4.9 8.4 23.7 0.67 1.31 1.75 56.50
XTE_020/180-18 18 SM13 40 0.19 0.25 3.5 4.5 6.6 0.41 0.57 0.77 32.90
XTE_020/180-24 24 SM14 40 0.29 0.39 3.0 3.7 9.6 0.46 0.55 0.74 53.00
XTE_020/180-36 36 SM15 40 0.37 0.50 3.7 5.2 13.9 0.55 0.81 1.09 45.90
XTE_020/180-48 48 SM21 20 0.53 0.71 4.9 8.4 14.8 0.43 0.84 1.12 63.40
XTE_020/180-72 72 SM22 20 0.79 1.06 5.4 10.8 21.9 0.61 1.31 1.76 60.20
XTE_020/180-144 144 SM23 20 1.48 1.98 8.9 14.8 44.4 0.67 2.38 3.18 62.30
XTE_030/360-12 12 SM21 80 0.53 0.71 4.9 8.4 14.8 0.43 0.84 1.12 63.40
XTE_030/360-18 18 SM32 40 0.51 0.68 5.4 7.1 15.8 0.39 0.84 1.12 60.20
XTE_030/360-24 24 SM21 40 0.53 0.71 4.9 8.4 14.8 0.43 0.84 1.12 63.40
XTE_030/360-48 48 SM30 20 1.12 1.51 10.4 17.9 34.1 0.43 1.78 2.39 63.10
XTE_030/360-72 72 SM23 40 1.48 1.98 8.9 14.8 44.4 0.67 2.38 3.18 62.30
XTE_030/360-144 144 SM31 20 3.38 4.52 14.8 31.1 95.0 0.68 4.01 5.37 84.20
XTE_040/720-12 12 SM30 80 1.12 1.51 10.4 17.9 34.1 0.43 1.78 2.39 63.10
XTE_040/720-18 18 SM44 40 0.84 1.13 7.5 12.9 22.6 0.39 1.17 1.56 72.40
XTE_040/720-24 24 SM30 40 1.12 1.51 10.4 17.9 34.1 0.43 1.78 2.39 63.10
XTE_040/720-36 36 SM40 40 1.68 2.25 10.4 21.2 53.2 0.67 2.78 3.72 60.60
XTE_040/720-48 48 SM41 20 1.95 2.61 12.7 26.4 47.0 0.49
XTE_040/720-72 72 SM31 40 3.38 4.52 14.8 31.1 95.0 0.68 4.01 5.37 84.20
XTE_040/720-144 144 SM42 20 5.82 7.81 26.6 55.1 147.8 0.73 7.74 10.37 75.30
XTE_050/1440-12 12 SM41 80 1.95 2.61 12.7 26.4 47.0 0.49 2.48 3.32 78.50
XTE_050/1440-18 18 SM40 80 1.68 2.25 10.4 21.2 53.2 0.67 2.78 3.72 60.60
XTE_050/1440-24 24 SM41 40 1.95 2.61 12.7 26.4 47.0 0.49 2.48 3.32 78.50
XTE_050/1440-36 36 SM43 40 2.89 3.87 15.5 31.1 77.4 0.56 3.46 4.63 83.60
XTE_050/1440-48 48 SM50 20 3.89 5.22 19.0 35.3 119.1 0.61 4.62 6.19 84.30
XTE_050/1440-72 72 SM42 40 5.82 7.81 26.6 55.1 147.8 0.73 7.74 10.37 75.30
XTE_050/1440-144 144 SM51 20 11.66 15.63 46.8 104.5 340.0 0.71 13.24 17.74 88.10
Notes:
Due to manufacturing tolerances there may be deviations from the published values.
1. Voltage tolerance value: -10% / +10%; Frequency tolerance value: -2% / +2%. If the voltage and frequency drops below above tolerances the actuator performances
cannot be guaranteed.
2. Power [KW] = Nominal Motor Output Power according to IEC 60034-1 is the mechanical power output at motor shaft at run torque of multi-turn actuator
(at approx. 40% of actuator nominal torque)
3. In (A) = (I-40%) = Motor current at approx. 40% of actuator nominal torque.
4. Is (A) = (I-100%) = Motor current at approx. 100% of actuator nominal torque.
5. Icc (A) =Locked rotor current.
6. Power Factor - Cosφ nom = (Cosφ 40%) = Power factor at approx. 40% of actuator nominal torque.
7. Absorbed Power [KW] = Absorbed electrical Power at approx. 40% of actuator nominal torque.
8. Nominal Duty S2-15' or S4-25% 60 starts/hours according to IEC 60034-1. Motor insulation: Class H. Tolerances on the published values according to IEC 60034-1.
INT WG
Ratio (:1)
Power
(KW)
Power
(HP)
In (A) Is (A) Icc (A)
Power
Factor
Absorbed
Power (KW)
2.48 3.32 78.50
Absorbed
Power (HP)
Efciency
(%)
20
Bettis XTE3000
February 2021
3-ph 240 V 50 Hz
Product Data Sheet
VCPDS-16245-EN Rev. 3
Size, Torque, Speed RPM Motor
XTE_010/30-12 12 SM00 40 0.03 0.04 0.7 0.8 1.2 0.46 0.13 0.18 23.10
XTE_010/30-18 18 SM01 40 0.05 0.06 0.7 0.9 1.5 0.42 0.12 0.16 38.30
XTE_010/30-24 24 SM10 20 0.07 0.10 2.3 2.9 4.7 0.43 0.41 0.55 17.30
XTE_010/30-36 36 SM11 20 0.11 0.14 2.3 2.7 5.4 0.43 0.41 0.55 25.90
XTE_010/30-48 48 SM04 20 0.15 0.19 2.2 4.1 5.4 0.47 0.43 0.58 33.80
XTE_010/30-72 72 SM05 20 0.22 0.29 2.0 4.4 8.5 0.56 0.47 0.62 46.30
XTE_010/30-144 144 SM06 20 0.42 0.57 2.8 4.3 11.8 0.71 0.83 1.11 51.30
XTE_010/90-12 12 SM10 40 0.07 0.10 2.3 2.9 4.7 0.43 0.41 0.55 17.30
XTE_010/90-18 18 SM11 40 0.11 0.14 2.3 2.7 5.4 0.43 0.41 0.55 25.90
XTE_010/90-24 24 SM12 20 0.12 0.17 3.2 3.6 5.4 0.46 0.61 0.82 20.30
XTE_010/90-36 36 SM13 20 0.19 0.25 3.3 4.4 6.9 0.41 0.56 0.75 32.90
XTE_010/90-48 48 SM14 20 0.28 0.38 2.8 3.6 10.0 0.46 0.54 0.72 53.00
XTE_010/90-72 72 SM15 20 0.37 0.49 3.5 5.1 14.5 0.55 0.80 1.07 45.90
XTE_010/90-144 144 SM16 20 0.74 0.99 4.7 8.2 24.7 0.67 1.31 1.75 56.50
XTE_020/180-18 18 SM13 40 0.19 0.25 3.3 4.4 6.9 0.41 0.56 0.75 32.90
XTE_020/180-24 24 SM14 40 0.28 0.38 2.8 3.6 10.0 0.46 0.54 0.72 53.00
XTE_020/180-36 36 SM15 40 0.37 0.49 3.5 5.1 14.5 0.55 0.80 1.07 45.90
XTE_020/180-48 48 SM21 20 0.53 0.71 4.7 8.2 15.4 0.43 0.84 1.13 63.40
XTE_020/180-72 72 SM22 20 0.79 1.06 5.2 10.6 22.9 0.61 1.32 1.77 60.20
XTE_020/180-144 144 SM23 20 1.47 1.98 8.5 14.5 46.3 0.67 2.37 3.17 62.30
XTE_030/360-12 12 SM21 80 0.53 0.71 4.7 8.2 15.4 0.43 0.84 1.13 63.40
XTE_030/360-18 18 SM32 40 0.51 0.68 5.2 7.0 16.5 0.39 0.84 1.13 60.20
XTE_030/360-24 24 SM21 40 0.53 0.71 4.7 8.2 15.4 0.43 0.84 1.13 63.40
XTE_030/360-48 48 SM30 20 1.13 1.51 10.0 17.5 35.6 0.43 1.79 2.40 63.10
XTE_030/360-72 72 SM23 40 1.47 1.98 8.5 14.5 46.3 0.67 2.37 3.17 62.30
XTE_030/360-144 144 SM31 20 3.38 4.53 14.2 30.5 99.1 0.68 4.01 5.38 84.20
XTE_040/720-12 12 SM30 80 1.13 1.51 10.0 17.5 35.6 0.43 1.79 2.40 63.10
XTE_040/720-18 18 SM44 40 0.85 1.13 7.2 12.6 23.6 0.39 1.17 1.56 72.40
XTE_040/720-24 24 SM30 40 1.13 1.51 10.0 17.5 35.6 0.43 1.79 2.40 63.10
XTE_040/720-36 36 SM40 40 1.69 2.26 10.0 20.8 55.5 0.67 2.79 3.73 60.60
XTE_040/720-48 48 SM41 20 1.95 2.61 12.2 25.9 49.0 0.49
XTE_040/720-72 72 SM31 40 3.38 4.53 14.2 30.5 99.1 0.68 4.01 5.38 84.20
XTE_040/720-144 144 SM42 20 5.83 7.81 25.5 54.0 154.3 0.73 7.74 10.37 75.30
XTE_050/1440-12 12 SM41 80 1.95 2.61 12.2 25.9 49.0 0.49 2.49 3.33 78.50
XTE_050/1440-18 18 SM40 80 1.69 2.26 10.0 20.8 55.5 0.67 2.79 3.73 60.60
XTE_050/1440-24 24 SM41 40 1.95 2.61 12.2 25.9 49.0 0.49 2.49 3.33 78.50
XTE_050/1440-36 36 SM43 40 2.88 3.86 14.8 30.5 80.8 0.56 3.45 4.62 83.60
XTE_050/1440-48 48 SM50 20 3.89 5.21 18.2 34.6 124.3 0.61 4.62 6.18 84.30
XTE_050/1440-72 72 SM42 40 5.83 7.81 25.5 54.0 154.3 0.73 7.74 10.37 75.30
XTE_050/1440-144 144 SM51 20 11.65 15.61 44.8 102.3 354.8 0.71 13.22 17.72 88.10
Notes:
Due to manufacturing tolerances there may be deviations from the published values.
1. Voltage tolerance value: -10% / +10%; Frequency tolerance value: -2% / +2%. If the voltage and frequency drops below above tolerances the actuator performances
cannot be guaranteed.
2. Power [KW] = Nominal Motor Output Power according to IEC 60034-1 is the mechanical power output at motor shaft at run torque of multi-turn actuator
(at approx. 40% of actuator nominal torque)
3. In (A) = (I-40%) = Motor current at approx. 40% of actuator nominal torque.
4. Is (A) = (I-100%) = Motor current at approx. 100% of actuator nominal torque.
5. Icc (A) =Locked rotor current.
6. Power Factor - Cosφ nom = (Cosφ 40%) = Power factor at approx. 40% of actuator nominal torque.
7. Absorbed Power [KW] = Absorbed electrical Power at approx. 40% of actuator nominal torque.
8. Nominal Duty S2-15' or S4-25% 60 starts/hours according to IEC 60034-1. Motor insulation: Class H. Tolerances on the published values according to IEC 60034-1.
INT WG
Ratio (:1)
Power
(KW)
Power
(HP)
In (A) Is (A) Icc (A)
Power
Factor
Absorbed
Power (KW)
2.49 3.33 78.50
Absorbed
Power (HP)
Efciency
(%)
21