Section 1: TEC2 CCM Programming Instructions
1.1 Using MPLAB IDE Software and MPLAB ICD3 Download Probe ........................ 4
1.2 Appendix ..................................................................................................... 16
Table of Contents
September 2015
Table of Contents
I
Page 4
Section 1: TEC2 CCM Programming Instructions
September 2015
TEC2-MPLAB-1001 Rev. 1
Section: 1 TEC2 CCM Programming Instructions
1.1 Using MPLAB IDE Software and MPLAB ICD3 Download Probe
Figure 1. Programming LDM in a Bare Board Setup
1. Connect the ICD3 probe box and USB cable to the computer.
Figure 2. USB Cable Connected to Computer
2. Connect the ICD3 probe box to the USB cable.
1
TEC2 CCM Programming Instructions
Page 5
TEC2-MPLAB-1001 Rev. 1
Figure 3. POWER LED should light when USB Cable is connected to PC and Probe
Section 1: TEC2 CCM Programming Instructions
September 2015
3. Connect the Programming Adapter Connector to the LDM board. Note the
Orientation of the Connector. Programming adapter is Bettis 37696.
TEC2 CCM Programming Instructions
2
Page 6
Section 1: TEC2 CCM Programming Instructions
September 2015
Figure 4. LDM ready to program with correct orientation of programming adapter
TEC2-MPLAB-1001 Rev. 1
3
TEC2 CCM Programming Instructions
Page 7
TEC2-MPLAB-1001 Rev. 1
Section 1: TEC2 CCM Programming Instructions
September 2015
4. On computer, run the MPLAB software by doubling clicking the icon.
Figure 5. Programming Header on LDM Board
TEC2 CCM Programming Instructions
4
Page 8
Section 1: TEC2 CCM Programming Instructions
September 2015
5. ICD 3 Software should start running.
Figure 6. Windows Desktop MPLAB IDE Icon
TEC2-MPLAB-1001 Rev. 1
6. Click File Import.
Figure 7.
5
TEC2 CCM Programming Instructions
Page 9
TEC2-MPLAB-1001 Rev. 1
7. Pick file to download. Then click Open.
Figure 8.
Section 1: TEC2 CCM Programming Instructions
September 2015
8. Select MPLAB ICD 3 for Programmer.
Figure 9.
TEC2 CCM Programming Instructions
6
Page 10
Section 1: TEC2 CCM Programming Instructions
September 2015
9. Click on Configure an then click on Select Device.
Figure 10.
TEC2-MPLAB-1001 Rev. 1
10. On the Select Device Screen, enter PIC24FJ256GA106 for the Device.
Figure 11.
7
TEC2 CCM Programming Instructions
Page 11
TEC2-MPLAB-1001 Rev. 1
11. Click on the Programmer Settings.
Figure 12.
Section 1: TEC2 CCM Programming Instructions
September 2015
12. Click on the Power tab. Enable the Check Mark on “Power target circuit from
MPLAB ICD 3”. Make sure power is set to 3.250V. Click OK.
Figure 13.
TEC2 CCM Programming Instructions
8
Page 12
Section 1: TEC2 CCM Programming Instructions
September 2015
13. Green Light will come on.
Figure 14.
14. Output Window will show a Device ID Revision and board should be powered up.
Figure 15.
TEC2-MPLAB-1001 Rev. 1
9
TEC2 CCM Programming Instructions
Page 13
TEC2-MPLAB-1001 Rev. 1
15. Click download button.
Figure 16.
16. You should see the status indication in the bottom left of the ICD 3 window.
Section 1: TEC2 CCM Programming Instructions
September 2015
Figure 17.
17. Verify that Programming/Verify complete shows in the Output window.
Figure 18.
TEC2 CCM Programming Instructions
10
Page 14
Section 1: TEC2 CCM Programming Instructions
September 2015
18. The display should now show information on the screen.
Figure 19.
TEC2-MPLAB-1001 Rev. 1
19. Click on the Power button to turn the power off.
Figure 20.
11
TEC2 CCM Programming Instructions
Page 15
TEC2-MPLAB-1001 Rev. 1
20. Click on the Power button to turn the power off.
Figure 21.
Section 1: TEC2 CCM Programming Instructions
September 2015
21. Congratulations, the board is now programmed and is ready for use.
Programming More Boards:
To program more board(s), keep everything the same as above, and then repeat these four instructions bellow:
22. Connect the Programming Adaptor and cable to the new board to be pro-
grammed (See Figure 4).
23. Click on the Power button. (See Figure 21).
24. Click on the Download button. (See Figure 17).
25. Read status in output window. (See Figure 19).
TEC2 CCM Programming Instructions
12
Page 16
Section 1: TEC2 CCM Programming Instructions
September 2015
1.2 Appendix
These instructions were written for MPLAB IDE Version 8.88.00.00.
NOTE:
Microchip ICD 3 Manual PDF link:
http://ww1.microchip.com/downloads/en DeviceDoc/51766B.pdf.
TEC2-MPLAB-1001 Rev. 1
13
TEC2 CCM Programming Instructions
Page 17
Page 18
World Area Confi guration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales offi ce nearest you:
NORTH & SOUTH AMERICA
19200 Northwest Freeway Houston TX 77065 USA T +1 281 477 4100
Av. Hollingsworth 325 Iporanga Sorocaba SP 18087-105 Brazil
MIDDLE EAST & AFRICA
P. O. Box 17033 Jebel Ali Free Zone Dubai T +971 4 811 8100
P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650
T +55 15 3413 8888
24 Angus Crescent
ASIA PACIFIC
Longmeadow Business Estate East
P.O. Box 6908 Greenstone No. 9 Gul Road #01-02 Singapore 629361 T +65 6777 8211
No. 1 Lai Yuan Road
1616 Modderfontein Extension 5
South Africa
T +27 11 451 3700
EUROPE
Wuqing Development Area Tianjin 301700 P. R. China T +86 22 8212 3300
Holland Fasor 6
Székesfehérvár 8000
Hungary
T +36 22 53 09 50
Strada Biffi 165
29017 Fiorenzuola d’Arda (PC)
Italy
T +39 0523 944 411
For complete list of sales and manufacturing sites, please visit
www.emerson.com/actuationtechnologieslocations or contact us at info.actuationtechnologies@emerson.com
www.emerson.com/bettis
©2018 Emerson. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
TM
is a mark of one of the Emerson family of companies.
Bettis All other marks are property of their respective owners.
The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
Loading...