Bettis Manual: Service Instructions for Models G01 through G10 Double Acting Pneumatic Actuators with M11 Hydraulic Override | Bettis Manuals & Guides

Service Instructions
124843E Rev. C
August 2015
G01 through G10 Double-Acting Pneumatic Actuators with M11 Hydraulic Override
Service Instructions
124843E Rev. C
Section 1: Introduction
1.1 General Service Information ......................................................................... 1
1.2 Denitions ................................................................................................... 2
1.3 General Safety Information ........................................................................... 2
1.4 Bettis Reference Materials ............................................................................. 3
1.5 Service Support Items .................................................................................. 3
1.6 Lubrication and Fluid Requirements .............................................................. 3
1.7 General Tool Information .............................................................................. 4
1.8 Actuator Storage ........................................................................................... 4
1.9 Actuator Installation ..................................................................................... 4
1.10 Actuator Start-Up .......................................................................................... 4
1.11 Actuator Operation ....................................................................................... 5
Table of Contents
August 2015
Section 2: Actuator Disassembly
2.1 General Disassembly .................................................................................... 6
2.2 Pneumatic Power Module Disassembly ......................................................... 6
2.3 Drive Module Disassembly ............................................................................ 9
2.4 M11 Hydraulic Override Cylinder Disassembly ............................................. 11
Section 3: Actuator Reassembly
3.1 General Reassembly .................................................................................... 13
3.2 Drive Module Reassembly ........................................................................... 13
3.3 Pneumatic Power Module Reassembly ........................................................ 18
3.4 G2 and G3 Early Model Pneumatic Power Module Reassembly..................... 21
3.5 M11 Hydraulic Override Cylinder Reassembly .............................................. 23
3.6 Actuator Testing ......................................................................................... 25
Section 4: Field Conversions
4.1 Construction Reversal (Exchange Module Locations) ................................... 27
Section 5: Module Removal and Installation
5.1 Pneumatic Power Module Removal .............................................................28
5.2 Pneumatic Power Module Installation ......................................................... 28
5.3 M11 Hydraulic Overrides Cylinder Removal ................................................. 29
5.4 M11 Hydraulic Override Cylinder Installation ............................................... 30
5.5 Powr Swivl Module Removal ........................................................................ 31
5.6 Powr Swivl Module Installation .................................................................... 31
Table of Contents
I
Table of Contents
August 2015
Section 6: Actuator Support Information
Section 7: Troubleshooting
Section 8: Removal and Decommissioning
Service Instructions
124843E Rev. C
6.1 M11 Hydraulic Override System Fluid Volume ............................................. 33
6.2 Module Weights by Item Number and Actuator Housing Size ...................... 33
6.3 G01 Tool Style and Wrench Size ..................................................................34
6.4 G2 Tool Style and Wrench Size..................................................................... 35
6.5 G3 Tool Style and Wrench Size..................................................................... 35
6.6 G4 Tool Style and Wrench Size..................................................................... 36
6.7 G5 Tool Style and Wrench Size..................................................................... 36
6.8 G7 Tool Style and Wrench Size..................................................................... 37
6.9 G8 Tool Style and Wrench Size..................................................................... 37
6.10 G10 Tool Style and Wrench Size ..................................................................38
7.1 Fault Insertion ............................................................................................. 39
7.2 Operational Test .......................................................................................... 40
8.1 Removal and Decommissioning .................................................................. 41
Section 9: Document Revision
Appendix A: List of Tables
Appendix B: List of Drawings
II
Table of Contents
Service Instructions
124843E Rev. C August 2015
Section 1: Introduction
Section 1: Introduction
1.1 General Service Information
1.1.1 This service procedure is offered as a guide to enable general maintenance to be performed on Bettis™ G01XXX-M11, G2XXX M11, G3XXX M11, G4XXX M11, G5XXX M11, G7XXX M11, G8XXX M11, and G10XXX M11 Double-Acting G-Series Actuators with one Pneumatic Power Module and one M11 or M11 S Hydraulic Override Module.
1.1.2 Normal recommended service interval for this actuator series is ve years.
NOTE:
Storage time is counted as part of the service interval.
1.1.3 This procedure is applicable with the understanding that all electrical power and pneumatic pressure has been removed from the actuator.
1.1.4 Remove all piping and mounted accessories that will interfere with the module(s) that are to be worked on.
1.1.5 This procedure should only be implemented by a technically competent technician who should take care to observe good workmanship practices.
1.1.6 Numbers in parentheses, ( ) indicate the bubble number (reference number) used on the Bettis assembly drawing and Actuator Parts List.
1.1.7 This procedure is written using the stop screw side of the housing (1-10) as a reference and this side will be considered the front side of the actuator. The housing cover (1-20) will be the top of the actuator.
1.1.8 Actuator module weights are listed in Section 6 Table 6.2.
1.1.9 When removing seals from seal grooves, use a commercial seal removing tool or a small screwdriver with sharp corners rounded off.
1.1.10 Use a non-hardening thread sealant on all pipe threads.
Introduction
CAUTION: FOLLOW MANUFACTURER'S INSTRUCTIONS
Apply the thread sealant per the manufacturer’s instructions.
1.1.11 Bettis recommends that disassembly of the actuator components should be done in a clean area on a workbench.
1
Section 1: Introduction
August 2015
1.2 Definitions
WARNING
If not observed, user incurs a high risk of severe damage to actuator and/or fatal injury to personnel.
CAUTION
If not observed, user may incur damage to actuator and/or injury to personnel.
NOTE:
Advisory and information comments provided to assist maintenance personnel to carry out maintenance procedures.
Service Instructions
124843E Rev. C
NOTE:
This product is only intended for use in large-scale xed installations excluded from the
scope of Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2).
1.3 General Safety Information
Products supplied by Bettis, in its “as shipped” condition, are intrinsically safe if the instructions contained within this Service Instruction are strictly adhered to and executed by well trained, equipped, prepared and competent personnel.
WARNING: READ WARNING MESSAGES CAREFULLY
For the protection of personnel working on Bettis actuators, this procedure should be reviewed and implemented for safe disassembly and reassembly. Close attention should be noted to the WARNINGS, CAUTIONS and NOTES contained in this procedure.
WARNING: FOLLOW PLANT SAFETY PROCEDURES
This procedure should not supersede or replace any customer’s plant safety or work
procedures. If a conict arises between this procedure and the customer’s procedures the
differences should be resolved in writing between an authorized customer's representative and an authorized Bettis representative.
2
Introduction
Service Instructions
124843E Rev. C August 2015
Section 1: Introduction
1.4 Bettis Reference Materials
1.4.1 Assembly Drawing for G01-M11 through G10-M11 Double-Acting with one Pneumatic Power Module and one Hydraulic Override Module use part number 115680.
1.4.2 M11 Manual Hydraulic Override System operating instructions part number 126858 with M11 Assembly Drawing part number 126567.
1.4.3 M11-S Manual Hydraulic Override System operating instructions part number 121962 with M11-S Assembly Drawing part number 121090.
NOTE:
If you require a specic assembly drawing (IE: GXX-M3 OR HYD) please contact Emerson Actuation Technologies Bettis by phone or email at info.actuationtechnologies@emerson.com
1.5 Service Support Items
1.5.1 Bettis module service kits.
1.5.2 For rod extension retainer nut tool part number, refer to the following table.
NOTE:
These tools are required only when extension rod assembly (1-50) or (9-50) is removed or when a new extension rod assembly is installed.
Table 1. G-Series Actuator Models
Actuator Model Bettis Part Number Actuator Model Bettis Part Number
G01 None required G5/G7 117369 G2 123616 G8/G10 117368 G3/G4 117370
1.5.3 Commercial leak testing solution.
1.5.4 Non-hardening thread sealant.
1.6 Lubrication and Fluid Requirements
NOTE:
Lubricants and hydraulic uids other than those listed in step 1.6.1 and 1.6.2 should not be
used without prior written approval of Bettis Product Engineering.
Introduction
1.6.1 All temperature services (-50°F to +350°F)/(-45.5°C to 176.6°C) use Bettis ESL-5 lubricant. ESL-5 lubricant is contained in the Bettis module service kit in tubes or cans and they are marked ESL-4, 5 and 10 lubricant.
1.6.2 FLUID REQUIREMENTS: M11 Manual Hydraulic Override System - All temperature service (-20°F to +350°F)/(-28.9°C to 176.6°C) use Dexron II or Shell Tellus T-32 Automatic Transmission Fluid. Low temperature service (-50°F to 150°F)/(-45.5°C to 65.6°C) use Univis J13 or HVI 13 Hydraulic Fluid.
3
Section 1: Introduction
August 2015
1.7 General Tool Information
1.7.1 Tools: All tools/Hexagons are American Standard inch. Large adjustable wrench, two (2) large screwdrivers, Allen wrench set, set of open/box end wrenches, rubber or leather mallet, torque wrench (up to 1200 foot pounds / 1627 N-m), breaker bar, small drift punch and a drive socket set. For recommended tool and wrench sizes refer to Section 6, Tables 6.3 through 6.10.
1.8 Actuator Storage
For applications where the actuator is not placed into immediate service, it is recom­mended that the actuator be cycled with regulated clean/dry pneumatic pressure at least once per month. Indoor storage, if available, is recommended for all actuators. Care should be taken to plug all open ports on actuator and controls to keep out foreign particles and moisture. Actuators should not be stored in an atmosphere that is harmful to resilient seals. Contact factory for extended storage period.
1.9 Actuator Installation
Service Instructions
124843E Rev. C
1.9.1 Since there are many valve and actuator combinations, it is not practical to include detailed instructions for each type. Mountings are designed to be as simple as possible to keep the guess work out of the installation.
1.9.2 Actuators that are shipped from the factory with the travel stops adjusted for approximately ninety degree rotation. Generally, it is necessary to make slight travel stop adjustments once the actuator is installed onto the valve. Refer to the
valve manufacturer's recommendations for specic requirements. When the valve
has internal stops, the actuator should be adjusted at the same points.
NOTE:
The actual "stopping" should be done by the actuator. If the valve does not have internal stops, adjust the actuator to the full open position. Using this as a reference point, rotate the valve closed and adjust to the valve manufacturer's specications for total rota­tion.
1.9.3 Good instrument practices are also recommended. Clean/dry regulated pneumatic pressure is essential for long service life and satisfactory operation. It should be noted that new pneumatic lines often have scale and other debris in them and these lines should be purged of all foreign material.
NOTE:
Scale and debris can damage control valves, solenoids, and seals.
1.10 Actuator Start-Up
1.10.1 Prestart-up checks
1. Inspect to ensure the unit has been mounted onto valve properly. Gear
ange mounting bolts, stem key, setscrew(s) are installed and secured.
4
Introduction
Service Instructions
124843E Rev. C August 2015
2. No tubing damaged or accessories dislodged during the shipping or the installation.
3. Indicated position conrms valve position.
4. All switching valves in normal operating position as per SCHEMATIC / INSTRUCTIONS
1.10.2 Check Connections
1. Pneumatic / hydraulic components connected as per schematic enclosed or in service manual supplied.
2. Pneumatic supply connected to the identied ports.
3. Electrical connection terminals are secured.
4. Wiring as per enclosed diagram or service manual supplied.
1.10.3 When actuator is rst placed into service, it should be cycled with regulated pneumatic pressure. This is necessary because the seals have been stationary, causing them to take a "set". Therefore, the actuator should be operated through several cycles to exercise the seals so as to achieve a service ready condition.
1.10.4 The actuator speed of operation is determined by a number of factors includes:
1. Power supply line length
2. Power supply line size
3. Power supply line pressure
4. Control valve and tting orice size
5. Torque requirements of the valve
6. Size of the actuator
7. Setting of speed controls
8. Hydraulic manual override (where available)
1.10.5 Due to the interaction of these variables, it is difcult to specify a "normal" operating time. Faster operating time may be obtained by using one or more of the following:
1. Larger supply lines
2. Larger control valve
3. Higher supply pressure *
4. Quick exhaust valves
* Not to exceed maximum operating pressure of actuator or
control components
1.10.6 Slower operating time may be obtained by using ow control valves to meter the
exhaust. Excessive exhaust ow metering may cause erratic operation.
Section 1: Introduction
1.11 Actuator Operation
1.11.1 Controlled Operation: Controlled operation is accomplished by pressurizing and/or depressurizing the appropriate cylinder inlet(s) of a double-acting. Do not exceed pressures indicated on actuator nameplate.
1.11.2 Manual Operation: All pressure must be vented or equalized on both sides of the pneumatic piston prior to manual operation.
Introduction
5
Section 2: Actuator Disassembly
August 2015
Section 2: Actuator Disassembly
2.1 General Disassembly
WARNING: DANGEROUS GAS AND/OR LIQUIDS
It is possible, that the actuator may contain a dangerous gas and/or liquids. Ensure that all proper measures have been taken to prevent exposure or release of these types of contaminants before commencing any work.
2.1.1 Section 2 - Actuator Disassembly is written to either completely disassemble the entire actuator or can be used to disassemble individual modules as needed (pneumatic power module or drive module, M11 override module or hydraulic override cylinder).
2.1.2 The pneumatic power module and the hydraulic override cylinder can be disassembled while still attached to the drive module or they can be removed from the drive module and disassembled separate to the actuator (refer to Section 5 ­Module Removal And Installation).
Service Instructions
124843E Rev. C
NOTE:
Use a means of capturing the hydraulic uid that will be lost during the removal or disassembly of
the hydraulic override power module. Use a bucket, tub, and large container, etc.
2.1.3 To ensure correct reassembly; that is, with pneumatic power module or M11 hydraulic cylinder assembly on same end of drive module as was, mark or tag right (or left) and mark mating surfaces.
2.2 Pneumatic Power Module Disassembly
NOTE:
Review Section 2 steps 2.1.1 through 2.1.3 General Disassembly before proceeding with pneumatic power module disassembly.
WARNING: DISCONNECT OPERATING PRESSURE
If not already removed disconnect all operating pressure from actuator power cylinders.
2.2.1 Mark and record location of the ports on outer end cap (3-80) and inner end cap (3-10).
2.2.2 Refer to assembly drawing sheet 1 Detail "E". Remove two socket cap screws (3-
130), with lockwasher (3-140), from outer end cap (3-80).
2.2.3 Remove two tie bar hex nuts (3-90) from outboard side of outer end cap (3-80).
6
Actuator Disassembly
Service Instructions
124843E Rev. C August 2015
Section 2: Actuator Disassembly
CAUTION: DO NOT DAMAGE O-RING GROOVE
Do not damage O-ring groove when removing end cap.
2.2.4 The t between cylinder (3-70) and outer end cap (3-80) is very tight. Break end cap free by tapping with a breaker bar on lip provided on the end cap. Remove outer end cap (3-80) from cylinder (3-70).
NOTE:
When removing cylinder (3-70) off of piston (3-30), tilt the cylinder 15 to 30 degrees with respect to actuator centerline.
2.2.5 Remove cylinder (3-70) from inner end cap (3-10).
CAUTION: DO NOT USE PIPE WRENCH
Do not use pipe wrench to remove tie bars.
2.2.6 TIE BAR REMOVAL:
NOTE:
G01, G2 and G3 models have ats on outboard end of tie bars (3-20) for wrench placement.
2.2.6.1 Remove G01, G2 and G3 tie bars (3-20) as follows:
2.2.6.1.1 Unscrew tie bars (3-20) from inner end cap (3-10). Pull the tie bars
2.2.6.1.2 Remove O-ring seals (4-80) from the inboard end of tie bars (3-20).
2.2.6.1.3 Remove tie bars (3-20) by pulling the tie bars out and through
NOTE:
G4 models have ats on outboard end of tie bars (3-20) for wrench placement.
NOTE:
G5 through G10 models have a female square on the outboard end of tie bars (3-20) for wrench placement.
out of the inner end cap far enough to expose the O-ring seals (4-80).
piston (3-30).
Actuator Disassembly
2.2.6.2 Remove G4 through G10 tie bars (3-20) as follows: Unscrew and remove
tie bars (3-20) from inner end cap (3-10) and piston (3-30).
7
Section 2: Actuator Disassembly
August 2015
2.2.7 Remove piston as follows: (On early G2 and G3 models equipped with outboard and inboard tie bar nuts skip this step and go to step 2.2.9).
2.2.7.1 Refer to assembly drawing page 2 of 2 Detail "D". Remove two split ring
halves (3-50) and one retainer ring (3-60) from outboard side of piston (3-30).
NOTE:
Piston (3-30) acts as the retainer for inboard split ring halves (3-50). When remov­ing the piston be careful to not lose inboard split ring halves (3-50).
2.2.7.2 Remove piston (3-30) and two split ring halves (3-50) from piston rod
(3-40).
NOTE:
Steps 2.2.8 is used only on early G2 and G3 models equipped with outboard and inboard tie bar nuts.
Service Instructions
124843E Rev. C
2.2.8 Remove early model G2 and G3 pistons as follows:
2.2.8.1 Refer to assembly drawing page 2 of 2 Detail "D". Remove two split ring
halves (3-50) and one retainer ring (3-60) from inboard side of piston (3-30).
NOTE:
Piston (3-30) acts as the retainer for outboard split ring halves (3-50).
2.2.8.2 Slide piston (3-30) toward the inner end cap (3-10) until the out board
split ring halves is exposed enough for removal. Remove outboard split ring halves from piston rod (3-40).
2.2.8.3 Remove piston (3-30) and two split ring halves (3-50) from piston rod
(3-40).
2.2.9 Remove O-ring seal (4-70) from piston rod (3-40).
2.2.10 Remove hex cap screws (3-100) with lockwashers (3-110) from housing (1-10).
2.2.11 Remove inner end cap (3-10) off of piston rod (3-40).
NOTE:
On early model G2 and G3 actuators remove two hex nuts (3-90) from housing (1-10). These two nuts will be loose after tie bars (3-20) are removed in step 2.2.6.1 and will be located in the area where the piston rod passes through the housing (1-10).
NOTE:
The piston rod (3-40) removal as outlined in step 2.2.12 is only required when the piston rod is being replaced or when the drive module is to be disassembled.
2.2.12 Unscrew and remove piston rod (3-40) from drive module.
8
Actuator Disassembly
Service Instructions
124843E Rev. C August 2015
Section 2: Actuator Disassembly
2.3 Drive Module Disassembly
NOTE:
Review Section 2 steps 2.1.1 through 2.1.3 General Disassembly before proceeding with drive module disassembly.
2.3.1 If not already removed remove piston rod (3-40) from drive module.
2.3.2 Mark stop screws (1-180) left and right.
NOTE:
The setting of stop screws (1-180) should be checked and setting recorded before stop screws are loosened or removed. Stop screws will be removed later in this procedure. For steps 2.3.3 through 2.3.10 refer to assembly drawing sheet 2 Section A-A and Detail “J”.
2.3.3 Before removing position indicator (1-220), record or mark its position. Remove position indicator (1-220).
NOTE:
Step 2.3.4 is used only on G01, G2 and G3 drive modules. Drive modules G4 through G10 will skip steps 2.3.4 and continue with step 2.3.5.
2.3.4 Remove one vent check assembly (13) from top of housing cover (1-20).
2.3.5 Unscrew and remove hex cap screws (1-160) with lockwashers (1-170) from yoke cover (1-150).
2.3.6 Remove yoke cover (1-150) from housing cover (1-20).
2.3.7 Mark and record the orientation of the position indicator assembly (1-140) in relation to the top of yoke (1-70).
2.3.8 Remove position indicator assembly (1-140) from top of yoke (1-70).
2.3.9 Remove spring pin (1-100) from top of yoke (1-70).
2.3.10 Remove hex cap screws (1-110), with lockwashers (1-115) from housing cover (1-20).
NOTE:
Steps 2.3.11 and 2.3.12 are used only on G7, G8 and G10 drive modules. Drive modules G01, G2, G3, G4 and G5 will skip steps 2.3.11 and 2.3.12 and continue with step 2.3.13.
2.3.11 Remove hex cap screws (1-120), with lockwashers (1-115), from housing cover (1-20).
2.3.12 Using hex cap screws (1-110), install into holes vacated by hex cap screws (1-120). Use these hex cap screws to jack the housing cover up for removal. Alternately rotate the hex cap screws clockwise until housing cover (1-20) is clear of housing (1-10).
Actuator Disassembly
9
Section 2: Actuator Disassembly
August 2015
NOTE:
G01, G2, G3 and G4 model housing cover will have cast tabs for placing prying tools to aid in cover removal.
2.3.13 Remove housing cover (1-20) from housing (1-10).
NOTE:
Groove pins (1-130) will remain in housing cover (1-20) when housing cover is removed from housing (1-10). Groove pins (1-130) should not be removed from housing cover (1-20) unless they are damaged and require new replacements.
2.3.14 Refer to assembly drawing sheet 2 Detail "B". Remove guide bar (1-90) from housing (1-10).
2.3.15 Remove top yoke pin thrust bearing (2-10) from top of yoke pin (1-80).
2.3.16 Rotate the arms of yoke (1-70) to the center position of housing (1-10).
2.3.17 Remove yoke (1-70) with yoke pin (1-80); guide block (1-30) and two yoke/guide block bushings (2-30), by lifting the yoke up and out of the housing (1-10).
2.3.18 Remove bottom yoke pin thrust bearing (2-10) from inside bottom of housing (1-10).
2.3.19 Remove yoke pin (1-80) by inserting 3/8"-16 UNC screw into top of the yoke pin and pull straight up and out.
2.3.20 Remove guide block (1-30) from between the arms of yoke (1-70).
2.3.21 Remove yoke/guide block bushing (2-30) from top of guide block (1-30).
2.3.22 Remove yoke/guide block bushing (2-30) from the top of the lower yoke arm of yoke (1-70).
Service Instructions
124843E Rev. C
10
NOTE:
G01 model actuators skip steps 2.2.23 through 2.2.25 and continue disassembly at step 2.2.26.
2.3.23 Refer to assembly drawing sheet 2 Detail "B". Use Bettis tool part numbers 117368 (G8/G10), 117369 (G5/G7), 117370 (G3/G4), or 123616 (G2) and remove retention retainer nut assemblies (1-60) and (9-60) from guide block (1-30).
2.3.24 Remove rod extension assemblies (1-50) and (9-50) from guide block (1-30).
NOTE:
Spherical washers (1-40) and (9-40) will be removed from guide block (1-30) when the extension rod assemblies are removed.
2.3.25 Remove the two remaining spherical washers (1-40) and (9-40) from guide block (1-30).
2.3.26 Unscrew and remove two stop screw nuts (1-190) from stop screws (1-180).
2.3.27 Unscrew and remove two stop screws (1-180) from front of housing (1-10).
2.3.28 Housing (1-10) vent check assembly removal as follows:
2.3.28.1 G01, G2 and G3 housing (1-10) unscrew and remove one vent check
Actuator Disassembly
Service Instructions
124843E Rev. C August 2015
assembly (13) from the front of housing (1-10).
2.3.28.2 G4 through G10 housing (1-10) unscrew and remove two vent check
assemblies (13) from the front of housing (1-10).
2.3.29 The following items do not need to be removed from their assembled locations unless being replaced by new items: Two yoke bearings (2-40 and yoke pin thrust bearing 2-10).
Section 2: Actuator Disassembly
2.4 M11 Hydraulic Override Cylinder Disassembly
NOTE:
Review Section 2 steps 2.1.1 through 2.1.3 General Disassembly before proceeding with M11 Hydraulic Override Cylinder Disassembly.
WARNING: DISCONNECT OPERATING PRESSURE
If not already removed disconnect all operating pressure from actuator power cylinder.
2.4.1 Place the M11 pump control knob (20-320) in the auto position.
NOTE:
Control knob (20-320) is located in front and at the bottom of the M11 pump manifold (20-
10). Using a means of capturing the hydraulic uid that will be lost during the following
steps. Use a bucket, tub, and large container, etc.
2.4.2 Remove all the piping from the M11 override cylinder outer end cap (7-80) and inner end cap (7-10).
2.4.3 Mark and record location of the ports on outer end cap (7-80) and inner end cap (7-10).
2.4.4 Remove NPT pipe plug or optional SAE O-ring plug (7-120) from outer end cap (7-80).
2.4.5 Remove hex nuts (7-90), with lockwashers (7-95), from tie bars (7-20).
2.4.6 Remove outer end cap (7-80) from cylinder (7-70), and tie bars (7-20).
2.4.7 Unscrew and remove tie bars (7-20) from inner end cap (7-10).
2.4.8 Remove cylinder (7-70) from inner end cap (7-10), piston (7-30) and piston rod (7-40).
2.4.9 Refer to assembly drawing sheet 2 Detail "G". Remove two split ring halves (7-50) and one retainer ring (7-60) from piston rod (7-40).
2.4.10 Remove piston (7-30) from piston rod (7-40).
2.4.11 Remove O-ring seal (8-70) from piston rod (7-40).
2.4.12 Refer to assembly drawing sheet 2 Detail "G". Remove two split rings (7-50) and one retainer ring (7-60) from piston rod (7-40).
2.4.13 Remove hex cap screws (7-115) with lockwashers (7-110) from inner end cap (7-10).
2.4.14 Remove hex nuts (7-105) from hex cap screws (7-100).
Actuator Disassembly
11
Section 2: Actuator Disassembly
August 2015
2.4.15 Remove hex cap screws (7-100) with lockwashers (7-110) from inner end cap (7-
10) and housing (1-10).
2.4.16 Remove inner end cap (7-10) off of piston rod (7-40).
NOTE:
The piston rod (7-40) removal as outlined in step 2.4.17 is only required when the piston rod is being replaced or when the drive module is to be disassembled.
2.4.17 Remove piston rod (7-40) from the drive module.
Service Instructions
124843E Rev. C
12
Actuator Disassembly
Service Instructions
124843E Rev. C August 2015
Section 3: Actuator Reassembly
Section 3: Actuator Reassembly
3.1 General Reassembly
CAUTION: CHECK SHELF LIFE OF SEALS
Only new seals, which are still within the seal’s expectant shelf life, should be installed into the actuator being refurbished.
3.1.1 Remove and discard all old seals and gaskets.
3.1.2 All parts should be cleaned to remove all dirt and other foreign material prior to inspection.
3.1.3 All parts should be thoroughly inspected for excessive wear, stress cracking, galling and pitting. Attention should be directed to threads, sealing surfaces and areas that will be subjected to sliding or rotating motion. Sealing surfaces of the cylinder, tie bars and piston rod must be free of deep scratches, pitting, corrosion
and blistering or aking coating.
CAUTION: INSPECT PARTS BEFORE USE
Actuator parts that reect any of the above listed characteristics should be replaced with
new parts.
3.1.4 Before installation coat all moving parts with a complete lm of lubricant. Coat all
seals with a complete lm of lubricant, before installing into seal grooves.
NOTE:
The parts and seals used in the actuator will be assembled using lubricant as identied in
Section 1 step 1.6.1 through 1.6.2.
3.2 Drive Module Reassembly
NOTE:
Review Section 3.1 General Reassembly before proceeding with drive module reassembly.
NOTE:
Drive module is to be assembled using the lubricant identied in Section 1 step 1.6.1.
Actuator Reassembly
13
Section 3: Actuator Reassembly
August 2015
3.2.1 If guide bar bearings are being replaced install new bearings into guide block (1-30).
NOTE:
The guide bar bearing must be pressed into guide block guide bar bore with the seam located ±5 degrees of the top or bottom centerline as shown in Section A-A.
NOTE:
G01 model actuators skip steps 3.2.2 through 3.2.13 and continue reassembly at step
3.2.14.
3.2.2 Lubricate guide block (1-30), two spherical washers (1-40), and one extension rod assembly (1-50).
3.2.3 Install one spherical washer (1-40) into the side of guide block (1-30).
Service Instructions
124843E Rev. C
NOTE:
The spherical side of washer (1-40) will be facing to the outside of guide block (1-30).
3.2.4 Install second spherical washer (1-40) over threaded end of extension rod assembly (1-50).
NOTE:
The spherical side of the washer will go on the extension rod assembly facing the head of the extension rod assembly.
3.2.5 Install extension rod assembly (1-50) into guide block (1-30) and up against the
rst spherical washer (1-40).
3.2.6 Install extension retainer nut assembly (1-60) over extension rod assembly (1-50) and screw into guide block (1-30).
3.2.7 Tighten extension retainer nut assembly (1-60) until extension rod assembly (1-50) cannot move. Back off the extension retainer nut assembly (1-60) just enough to allow for extension rod assembly (1-50) to move freely.
3.2.8 Lubricate two spherical washers (9-40) and one extension rod assembly (9-50).
3.2.9 Install one spherical washer (9-40) into the side of guide block (1-30).
14
NOTE:
The spherical side of washer (9-40) will be facing to the outside of guide block (1-30).
3.2.10 Install second spherical washer (9-40) over threaded end of extension rod assembly (9-50).
Actuator Reassembly
Service Instructions
124843E Rev. C August 2015
NOTE:
The spherical side of the washer will go on the extension rod assembly facing the head of the extension rod assembly.
3.2.11 Install extension rod assembly (9-50) into guide block (1-30) and up against the
rst spherical washer (9-40).
3.2.12 Install extension retainer nut (9-60) over extension rod assembly (9-50) and screw into guide block (1-30).
3.2.13 Tighten extension retainer nut assembly (9-60) until extension rod assembly (9-50) cannot move. Back off the extension retainer nut assembly (9-60) just enough to allow for extension rod assembly (9-50) to move freely.
NOTE:
Consult Houston, Texas Bettis Service Coordinator for “yoke bearing, yoke pin bearing or yoke/guide block bushing installation information.
Section 3: Actuator Reassembly
3.2.14 If the two yoke bearings (2-40) are being replaced, install new bearing into housing cover (1-20) and housing (1-10).
NOTE:
The yoke bearing (2-40) must be pressed into housing (1-10) and housing cover (1-20). Install the yoke bearings with the bearing seam located 45 ±5 degrees from the yoke arm slot when yoke (1-70) is rotated to its full clockwise position.
3.2.15 If the two yoke pin bearings (2-10) are being replaced install new bearing into housing cover (1-20) and housing (1-10).
3.2.16 Lubricate two yoke/guide block bushings (2-30) and install onto top and bottom sides of guide block (1-30).
NOTE:
The guide block (1-30) should be already pre-assembled with extension rod assembly and associated parts assembled in the guide block.
3.2.17 Install guide block (1-30), with yoke guide block bearings (2-30), between arms of yoke (1-70).
3.2.18 Install one O-ring seal (2-50) into inner diameter seal groove in the bottom of housing (1-10).
3.2.19 Coat the bearing surfaces of yoke (1-70) with lubricant and install into housing (1-10).
3.2.20 Align hole in guide block (1-30) with the matching holes in the two yoke/guide block bushings (2-30) and the slots in the arms of yoke (1-70).
Actuator Reassembly
15
Loading...
+ 42 hidden pages