Bettis Manual: 21078 Motor Brake Kit Manual | Bettis Manuals & Guides

TorqPlus EM Motor Brake Kit
Installation and Operating Instructions
Bulletin: 21078- 09/01. This bulletin provides installation and operating information for the TorqPlus EM Motor Brake Kit. Should you have
any questions about the controller that are not covered under this bulletin, please contact an authorized Bettis Valve Automation Center or Bettis Electric Division, Mansfield, Ohio U.S.A., 419-529-4296.
1.0 Caution
Electrical shock and/or explosion hazard may exist. To avoid serious personal injury, death, or property dam­age due to electrical shock and/or ignition of hazardous atmospheres, turn off all power to the actuator before removing the actuator cover.
2.0 Kit number and model usage
3.0 Inspection
Because this optional product is being supplied as a kit, review of the actuator’s nameplate and the kit utiliza­tion information is recommended to insure compatibility before use.
4.0 Documentation
Bettis maintains accurate records on every actuator sold. Completion and transmittal of a Product Modifica­tion Report (form #ESO-01) is required.
5.0 Cover Removal
Follow section 7.0 in Bulletin #21077 (TorqPlus EM Series Installation and Operating Instructions) supplied with the actuator.
TorqPlus EM Motor Brake Kit Installation and Operating Instructions
300 Series, AC Brake Assembly
6.0 Installation Instructions
300 Series, AC Actuator (reference photo above)
Ø Place the brake bracket over the motor shaft and secure using four (4) #6-32 x 3/8 pan head machine
screws with lockwashers.
Ø Place brake onto the bracket and loosely secure using three (3) #4-40 x 7/8 pan head machine screws. Ø Insert feeler gauges (0.010 to 0.012 in.) between the brake and the bracket. Ø Place the brake hub onto the motor shaft with the square portion of the hub inserted tightly into the square
of the brake disk.
Ø Secure the brake hub by tightening the set screws. Ø Remove the feeler gauges and tighten the #4-40 screws on the brake. Ø Remove the two motor leads from the capacitor. Ø Place a “Y” connector on the two empty capacitor terminals and reinstall the motor leads to the proper
terminals.
Ø Install the two leads from the brake to the remaining open terminals of the “Y” connector.
300 Series, DC Brake Assembly
2
Loading...
+ 2 hidden pages