Installation Instruction
1
2
1
3
2
6.1 to 6.6 Nm
(54 - 58.4 In.lbf.)
DA
SA
FILP
1
3
2
6.1 to 6.6 Nm
(54 - 58.4 In.lbf.)
DA
SA
FILP
2
6
1
5
1
2
OK !
1
3
2
6.1 to 6.6 Nm
(54 - 58.4 In.lbf.)
DA
SA
FILP
2
6
DOC.QC4.MTI.1 Rev. B
October 2015
Mechanical Installation procedure of XP Control Modules (QC4x).
Control Modules
1 Check if the module has the required function.
1
DA
SA
2 Remove the transparent lm.
2
3 Ensure seals are placed correctly.
FILP
3
5 Place the alignment-edge (1) of the control module at the
top of the pneumatic interface.
Flip the module down taking care that the IPT Probe (2)
on the actuator ts in the mating hole on the control module and loosely place the screws.
5
6 Tighten screws according to the force - and in sequence
as shown below.
1
2
3
6
1
6.1 to 6.6 Nm
(54 - 58.4 In.lbf.)
2
4 Level the screws with the surface.
4
OK !