Bestcare PL182, PL228 User Guide

Page 1
BESTLIFT®
FULL BODY PATIENT LIFT
Model: PL182 / PL228
PL228 model shown
Ensure the product has been assembled according to the instructions in this manual. All operators should read and understand the instructions for safe and proper operation of the patient lift.
Page 2
Thank you for choosing Bestcare!
To better serve you, please record the following information for future use:
Supplier Name: ___________________________________________
Supplier Telephone: ________________________________________
Product Serial Number: _____________________________________
Date of Purchase: _________________________________________
Date of Manufacture
BestLift PL182
MASS OF LIFT:101LB(46KG)
2920 Pacific Dr,
Norcross, GA 30071
1-678-679-6690
S/N: PL182YYMM2XXX
This product has been tested by SGS, an accredited testing institute to comply with the requirements of:
ISO 10535, IEC 60601-1, ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No.60601-1, IEC 60601-1-11, ANSI/AAMI HA60601-1-11, CAN/CSA-C22.2 No.60601-1-11, IEC 60601-1-2
®
The manufacture date can be found on the serial number label that is located at the top of the mast. The YY in the serial number is the manufacture year, and the MM is the manufacturing month.
1
Page 3
i
The Bestlift® PL182 and PL228 allow patients up to 400lbs and 500lbs, respectively, to be lifted and transferred safely with minimal physical effort provided by the operator. That is due to it being a full electric lift . With the PL182 and PL228, patients
can be lifted from oor to bed with ease. Additionally, patients
can be moved from surface to surface with extra comfort as a result of the 6 point spreader bar. With the addition of the optional battery pack you will never have to be worried about your lift not being charged and ready for use.
Product Description
i
The PL182 and PL228 are intended to be used with patients who are completely immobile or totally dependent on the patient lift for transfers. The PL182 and PL228 are intended to be used for transfers of the patient in and out of bed, their wheelchair, to and from the commode, or any other type of surface. The PL182 and PL228 are intended to be operated by at least one caregiver who will perform the lift and transfer.
Transfers should always be done on a at, dry surface and
are not intended to be used in high humidity environments for extended amounts of time.
Intended Use
2
Page 4
DEFINITIONS & SYMBOLS
Type BF applied part. Refer to the part of
for the device to carry out its intended
European Conformity mark, The product
safety and environmental requirements.
In this manual the user refers to the patient or resident and may be used
interchangeably at different times. Caregiver refers to the operator or person who is assisting with the transfer.
Symbols used in this manual and on the product and their meanings:
Warning! Failure to heed this warning may result in damage to the product or serious injury to the operator and/or user.
Important instructions follow. Read and understand the instructions in the manual before using the product.
the medical device which come into physical contact with the patient in order
Class II symbol. To identify equipment is designed that a connection to electrical earth (ground) is not required.
Note! Important information concerning the product and/or its correct and proper usage follows.
Advise the operator to consult the accompanying documents before use.
Do Not Bleach. No bleach product may be used. The garment is not colorfast or structurally able to withstand any bleach.
Do Not Dryclean. Garment may not be commercially drycleaned.
Do Not Iron. Item may not be smooted or finished with an iron.
Tumble Dry, Normal, Low Heat. A machine dryer may be regularly used at a maximum of Low Heat setting.
Do Not Dry. A machine dryer may not be used.
Machine Wash, Hot. Initial water temperature should not exceed 82°C or 180°F.
Right side up Do Not Wash
Fragile, handle with care Keep dry
Carton storage temperature limit of -25°C to 70°C
conforms to European Medical Directive 93/42/EEC and meets applicable health,
Carton storage humidity limit of 0% to 90%
Handle with care
3
Page 5
Safety Instructions
The BestLift® Series of full body patient lifts reect innovative state of
the art design to increase user mobility. A BestLift® will provide years of service if it is properly maintained as any electric and/or mechanical equipment requires. Please pay careful attention to the following important information regarding the care, maintenance, and operation of the patient lift. Carefully read these instructions before assembling the lift, or attempting to lift a user with the device.
• Before attempting to lift anyone, please practice operating the lift. Also prior to actual lifting, explain the lifting procedure to the user/ patient.
• Special care must be taken with users/patients who cannot Themselves by provide proper assistance while being lifted. (i.e. patients who are comatose, spastic, agitated, or otherwise severely handicapped.)
• The patient lift should be used solely for transferring a user/patient from one utility (beds, chairs, toilets, etc.) to another. The patient lift should not be used for transporting or moving any patient from one location to another location.
• During lifting or lowering, whenever possible, always keep the base of the lift in the widest position.
• The base of the lift should be closed before moving the lift.
• Do not roll casters over any object while the user/patient is in the sling.
• Do not lock casters during lifting.
• While being lifted in a sling, always keep the user/patient centered over the base and facing the caregiver operating the lifter.
• Never leave the user/patient unattended during lifting.
Service personnel may contact Bestcare for any information, instructions or certain parts for servicing purpose.
4
Page 6
WARNING!
• NO modication of this equipment is allowed. It is unsafe to modify the equipment from its original state. This product is deemed safe to use with only the original parts as delivered. Unauthorized use of any modied equipment may result in serious injury or death.
• DO NOT replace any components of the lift without consulting with Bestcare, and must follow proper instruction from Bestcare when replacing any components.
• DO NOT service any parts of the lift while in use with a patient.
• It is NOT safe to load the equipment more than the indicated maximum safe working load.
• IF any accessories with lower load capacity than the equipment itself is used, DO NOT load the equipment more than the lowest maximum safe
working load.
• REMOVE the battery pack if the lift will not be used for some time, to prevent battery leakage. PERIODICALLY check the battery pack as well as the charger if necessary
• This equipment DOES NOT consist of any materials or ingredients to which patients are exposed, that may cause bodily harm or injury.
• Prolonged exposure or physical contact with any part of the equipment WILL NOT cause skin irritation, allergic reaction, etc.
• Using accessories, detachable parts, or materials not described in the instruction manual MAY RESULT IN SERIOUS INJURIES.
• Keep the equipment away from children and pets when in use. IT MAY
CAUSE SERIOUS INJURY OR DEATH.
• Keep the equipment away from pests or pest infested area. Diseases transferred from pests to the equipment MAY CAUSE SERIOUS ILLNESS to patients upon contact.
• If the lift is left under the sun for long period of time, be CAUTIOUS as the surface of the lift may be hot.
• There are no risk if the lift is exposed to reasonably foreseeable environmental conditions
• CAUTION! The controller contains parts and assemblies that could be susceptible to damage by electrostatic discharge (ESD). To reduce the likelihood of this from happening, one should be grounded prior to operate the controller.
• DO NOT use the lift on a inclined surface that greater than 5°
5
Page 7
FEATURES & OVERVIEW
8.6 lb
(3.9 kg)
1.1 lb
(0.3 kg)
14.3 lb
(6.5 kg)
9.9 lb
(4.5 kg)
8.4 lb
(3.8 kg)
11 lb
(5 kg)
0.7 lb
(0.3 kg)
46.5 lb
(21.1 kg)
Prior to assembly, unpack and inspect all parts from the shipping carton.
i
Contact you dealer immediately if any parts are damaged or missing.
16mm
Wrench
* PL228 model shown
17mm
Wrench
Screwdriver
12
3
2
11
10
4
5
1
9
1 Spreader Bar
2 Boom
3 Control Unit
4 Hand Control
** Heaviest detachable part
8
6
7
5 Leg Opening Handle
6 Rear Caster 10 Actuator
7 Front Caster 11 Emergency Lowering
8 **Base
9 Mast
12 Emergency Stop Button
Class II Equipment
6
Page 8
I
mm (in) mm (in)
A 1910.8 (75.2) 1910.8 (75.2)
B 1108.4 (43.6) 1108.4 (43.6)
C 802.4 (31.6) 802.4 (31.6)
D 582.9 (22.9) 582.9 (22.9)
E 963.2 (37.9) 963.2 (37.9)
F 852.5 (33.6) 852.5 (33.6)
G 547 (21.5) 547 (21.5)
H 291.9 (11.5) 291.9 (11.5)
I 583.2 (23.0) 583.2 (23.0)
J 285.3 (11.2) 285.3 (11.2)
K 377 (14.8) 377 (14.8)
L 123.4 (4.9) 123.4 (4.9)
M 33.4 (1.3) 33.4 (1.3)
B
J
A
K
C
600
L
M
D
PL182 PL228
E
F
700
G
H
7
Page 9
SPECIFICATIONS & OPTIONS
Dimensions & Specifications
Model
PL182
PL228
PL273
Safe Workin g Load
400 lb
500 lb
600 lb
A
Base Length
44.9"
44.9"
44.9"
B
Base Ext. Width - Closed
24.9"
24.9"
24.9"
C
Base Ext. Width - Opened
42.9"
42.9"
42.9"
D
Mast Height
48.3"
48.3"
48.3"
E
Front Caster Height
4.5"
4.5"
4.5"
F
Lifting Height - Lowest
25.8”
25.8”
25.8”
G
Lifting Height - Highest
69.1”
69.1”
69.1”
H
Turning Diameter
61.3”
61.3”
61.3”
PL182 PL228 PL273
Lift Weight Unloaded (lb) 100.6 100.6 100.6
Lift Weight Unloaded (kg) 45.7 45.7 45.7
Specications of Control Unit
Input Voltage 220-240VAC 50Hz / 110-120VAC 60Hz
Output Voltage 24 VDC
Battery Pack 24 VDC 5AH
Lift Control Handset and Panel
Protection Class IP54 (Protection against dust and splash of water)
Sound Level Under Full Load 16db
Sound Level Under No Load 11db
Lift Cycles Per Charge 25 full cycles under full load
Overload Warning by LCD
H
B
A
Standard Features
1 6-Point Spreader Bar 2 4” Rear Caster with Brake 3 3” Dual Front Caster 4 Power Control Unit
Optional Features
1 2-Point Spreader Bar 2 Charging Cradle 3 Digital Scale 4 Additional Battery pack
* Bestcare is committed to continuous improvements of our products therefore the
specication, dimensions, and features listed above are for guidance only and are
subject to change without prior notice.
8
Page 10
Installation 1: Base and Mast
1
2
3
Secure Mast by tightening bolt
Installation 2: Boom
9
Page 11
Installation 3: Actuator
1
2
Installation 4: Spreader Bar
10
Page 12
Installation 5: Power Control Unit
1
2
3
4
5
11
Page 13
Operating Instructions
i
Double check all assemblies for tightness and read operating instructions carefully prior to use.
For optimum performance the lift should be transported and stored in following condition range:
• -25°C to +5°C (-13°F to 41°F), and
• +5°C to +35°C (41°F to 95°F) at a non-condensing relative humidity 0% to 90%
• +35°C to +70°C at a water vapor pressure up to 5 kPa
For optimum performance the lift should be operated in following condition range:
• at a temperature range of +5°C to +40°C (+41°F to +104°F)
• at a non-condensing relative humidity range of 15 % to 90 %, but not requiring a water vapor partial pressure greater than 5 kPa
• 70 kPa to 106 kPa atmospheric pressure
The lift will not have any potential electromagnetic or other interference with other devices.
PREPARATION BEFORE LIFTING
• Twist the RED EMERGENCY STOP BUTTON clockwise.
• Verify the Lifting and Lowering Functions by pressing either the UP or DOWN button on the hand control once.
• Position the base of the lift around or under the object.
• Widen the base and disengage the caster brakes.
Do not attempt to transfer a patient without prior approval of the person’s nurse.
i
Also, do not transfer without having studied the instructions and performed several practices in operating the product. Together (with the patients doctor, nurse, or medical attendant) select a sling that is both practical and comfortable. The sling selected should be one that serves the needs of the patient, while providing the patient with optimal safety. Never interfere with the lift, unless instructed by the attendant. Have a doctor, nurse, or medical attendant
(experienced in the use of the BestLift®) present during the rst few times the lift
is used to transfer a new user.
12
Page 14
Actuator
Battery Pack Release Handle
Emergency Stop Button
Up / Down Button
LCD Display Panel
Battery Pack
Charger
DC In
Not Used
Hand Control
Charging Cradle
(Optional)
Additional Battery Pack
(Optional)
Power Control Unit Overview
• Contains a long charger cord that may cause strangulation if
1. Connect Actuator as shown above.
2. Connect Hand Control as shown above.
WARNING!
used improperly
• Keep long charger cord out of walkway where it poses a tripping hazard
• Have the charger port on the controller facing away from the wall for easy disconnection
13
Page 15
Release Pressed in
LCD Display Panel Signs
When the emergency stop button is released, the LCD Display Panel will show one of the four signs below.
• The sign will display for 5 seconds.
• Then the lift will go into standby mode and the sign disappears.
• The lift is ready for use.
Charging: DC Charger or Charging Cradle
Charging Cradle
DC Charger (included)
LED Indicator
* Amber = charging * Green = charging completed
LCD Display Panel Signs - Charging
During charging, the LCD Display Panel will show one of the four signs below.
• The DC Charger must be connected.
• The emergency stop button must be released.
• The battery will not be charged if the emergency button is pressed in.
(Optional)
LED Indicator
* Green = power connected * Blank = power disconnected
Charger Plug-in
14
Page 16
Operating Lift: Using Hand Control
Lifting
Lowering
LED Indicator
* Green = In Use * Blank = Standby
Operating Lift: Using LCD Display Panel
15
Page 17
Warning! - Battery Low and Charging is Needed
If the battery needs to be charged, the LCD Display Panel will show a blinking low battery sign shown on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed.
• Lift is still functioning.
• Buzzer will beep every 2 seconds.
• Battery needs to be charged immediately after use.
Warning! - Overloaded
During lifting if the lift is overloaded, the LCD Display Panel will show the sign on the left and lifting will be deactivated immediately.
• The buzzer will beep 3 times.
• Lowering the lift by pressing the DOWN button is still allowed.
• The emergency stop button must be pressed in and then release the button before further lifting.
Warning! - Charge Battery Immediately
If the battery is critically low, the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed.
• Lift operation is deactivated.
• Battery needs to be charged immediately be­fore further use.
16
Page 18
Available slings compatible with Patient Lift
Sling Type Material Sizes
Mesh M, L
Universal
Polyester M, L, XXL
Mesh S, M, L
Universal with Head Support
Polyester S, M, L, XXL
Universal Disposable Nonwoven, Disposable M, L
Universal Disposable with Head Support Nonwoven, Disposable S, M, L, XXL
Sani Polyester S, M, L, XXL
Polyester M, L, XL
Invacare® Replacement
Mesh M, L, XXL
Invacare® Replacement with Head Support Mesh M, L, XL, XXL
Hoyer® Replacement Polyester M, L, XL
Hoyer® Replacement with Head Support Polyester M, L, XL
Liko®/Guldmann® Replacement Polyester with PU Coating M, L, XL
Liko®/Guldmann® Replacement with Head Support Polyester with PU Coating M, L, XL
Liko®/Guldmann® Disposable Replacement Nonwoven, Disposable M, L, XL
Liko®/Guldmann® Disposable Replacement with Head Support Nonwoven, Disposable M, L, XL
Mesh
Pediatric with Head Support Standard
Polyester
If the patient is pregnant or has any skin conditions, consult with a doctor before use.
ALWAYS check that sling weight capacity is suitable for the patient
All slings are type BF applied parts
For further product information and support, please contact your dealer or visit our website at www.bestcarellc.com
17
Page 19
2 Point S-Bar
1
2
6 Point S-Bar
1
3
5
6
2
4
4 Strap Sling
AB
CD
Point 1Hook up A Point 2Hook up B
Point 5Hook up D Point 6Hook up C
Insert D through C
Point 2Hook up B
Point 1Hook up A
Point 1Hook up D Point 2Hook up C
Insert D through C
6 Strap Sling
AB
CD
EF
Point 1Hook up A Point 2Hook up B Point 3Hook up C Point 4Hook up D
Point 5Hook up F Point 6Hook up E
Insert F through E
Point 1Hook up A, C Point 2Hook up B, D
Point 1Hook up F Point 2Hook up E
Insert F through E
8 Strap Sling
AB
GH
CD
E
F
Point 1Hook up A & C
Point 2Hook up B & D Point 3Hook up E Point 4Hook up F
Point 5Hook up H Point 6Hook up G
Insert H through G
Point 1Hook up A, C, E Point 2Hook up B, D, F
Point 1Hook up H Point 2Hook up G
Insert H through G
Sling Hook-Up Guide
BEFORE LIFTING THE PATIENT, PULL ON TO ENSURE THE LOOP IS HOOKED ONTO THE SPREADER BAR
PROPERLY
For further product information and support, please contact your dealer or visit our website at www.bestcarellc.com
18
EACH SLING LOOPS
Page 20
Transfer From Bed to Wheelchair
• User/patient should be in the center of the bed.
• Position user onto his/her side by rolling user towards you.
• Roll the sling in half. The handle on the back section should face
outward when the sling is tted.
• Position the sling under the user/patient so the commode aperture aligns with the base of the spine and top of the sling close to the neck.
• Roll user onto the opposite side and position him/her on the at section of the sling. This will allow you to unroll the remainder of the sling from the other side of the user.
• Once the sling has been positioned centrally, feed the leg sections under the thighs and draw them up between the thighs.
• Raise the head of the bed if this function is available.
• Move the lift slowly towards the user and position the spreader bar over the user’s/patient’s chest. Attach loops of the sling to the hooks on Spreader Bar as shown in the Sling Hook-Up Guide on next page.
• Lift the user above the bed by using the hand control.
• Pull lift away from bed. Position user over the wheelchair or chair then lower the patient onto the surface.
• Reverse the above procedures when returning the user/patient to bed.
Transfer From Wheelchair to Bed
• Grasp the sling at each corner of the “U” shape of the commode aperture.
• The sling should be tted with the grab handles on the back section facing outward.
• Help the user lean forward slightly, then slide the sling down between the chair and the user’s back.
• Position the commode aperture where the buttocks meets the seat.
• Position the sling equally around both sides of the body.
• Draw the leg sections to the front along the length of the user’s thigh.
• Check the sling’s central positioning by comparing the lengths of the leg sections when they are drawn forward.
• Reposition the sling if the leg sections are not equal in length.
• Feed the leg sections under the thighs.
• From between the legs, gently pull the leg section up the inner thigh. Feed as much material as possible under and between the thighs. Ensure the leg sections are positioned midway under the thighs to provide good support and greater comfort.
• Move the lift slowly towards the user and position the spreader bar over the user’s chest. Attach loops of the sling to the hooks on Spreader Bar as shown in the Sling Hook-Up Guide on next page.
• Lift patient above the wheelchair by using the hand control.
• Pull lift away from wheelchair. Position patient over bed and lower patient onto bed
• Reverse the above procedures when returning the user/patient to a wheelchair.
19
Page 21
Maintenance & Inspection
First Received MonthlyEvery 3 Months
Check connections between boom and spreader bar for improper connection,
Check connections between boom and mast for improper connection, looseness or wear.
Check the boom for bending and deflection.
Check the mast for bending or deflection.
Check bolts and nuts for looseness.
Check casters and axle bolts for tightness.
Check rubber parts on the casters for deflection.
Apply grease to caster ball bearings if needed.
Check welding joints for rust and crack.
Make sure the control box is firmly affixed to the mast.
Make sure the actuator is secured to the boom and mast with pins and key rings.
Make sure actuator plug into control box is not loose.
Check sling for wear.
Check sling hardware every time before use.
Lift Cleaning
As Needed.As Needed.As Needed.
Boom & Spreader Bar
Mast
Base & Foot Pedal
Actuator & Control Box
Sling & Sling Hardware
• The operator of the lift shall inspect the BestLift before each use. Check all bolts for tightness. Make sure the base can be easily widened, and that all lift parts are in place. Make sure that casters can be turned freely, and that caster brakes can be engaged. Make certain all necessary items (i.e. slings, and wheelchairs, etc.) are ready for use.
• At least once a month, the lift should be thoroughly inspected by a person
qualied to recognize any signs of wear and tear, and looseness of bolts or
parts. Replace any worn parts immediately.
• To lubricate, put silicone lubricating grease on the following points when the BestLift® is placed into service and every month thereafter: Top of Mast, Spreader Hinge, and Caster Axles.
• With proper use and care, the expected lifetime of the lift is 10 years or 20,000 cycles.
• The expected lifetime of the electrical components are 3 years.
• Contact Bestcare for any recycling information
20
Page 22
Cleaning and Disinfecting
Cleaning of the lift
• Use pH-neutral detergents only.
• Remove the battery from the controller
• Clean lift surfaces, control box and hand control with a damp cloth using pH-neutral detergent.
• Remove debris and hair from the casters and make sure the casters can spin and swivel freely.
• Solvents or strong liquids or abrasive cleaning products will damage the surfaces of the lift.
Cleaning of the sling
• Check with sling label for washing condition.
• As for minor cleaning between patient uses, we recommend wipes with water-soluble soap or isopropyl alcohol.
• For slings with rigid supports, remove the plastic inserts before washing. (Look for an opening near the plastic inserts for removal)
• Machine wash warm or cold.
• Do not wash with other colors.
• Air dry or very low dryer heat.
• DO NOT USE BLEACH.
• DO NOT clean or wash disposable slings.
• REPLACE a sling when it show signs of deterioration.
Deterioration of sling
• Contact Bestcare for “Guideline for Identifying Deteriorated Slings” if needed.
Disinfecting of the lift and sling
• Inspect slings prior to each use for contamination from previous use.
• Use isopropyl alcohol for any disinfection purpose.
• Wash a reusable sling for serious contamination
• Replace a disposable sling for any contamination
• Reusing a contaminated sling can cause serious bacterial infection
21
Page 23
WARRANTY POLICY
Bestcare offers a limited warranty on all patient lifts, slings and accessories to be free of defects in workmanship and product performance. This warranty extends only to the original purchaser and is non-transferable. All warranty claims must be submitted by the authorized dealer or distributor who originally sold the product with proper proof of sale and serial number where applicable. Prior Return Authorization (RA) from Bestcare is required for all warranty replacements. Bestcare reserves the right to repair or replace only defective parts or accessories in lieu of a complete new patient lift. The repaired or replacement part shall be warranted for a period equal to the remainder of the warranty period of the defective part.
Bestcare does not provide advance replacements for warranty claims. For situations where an end user requires a replacement in advance and before a warranty item can be returned, dealer or distributor must purchase the replacement at full cost. All freight charges for the replacement are the sole responsibility of the dealer or distributor. When end user returns warranty item and item proves to be defective, Bestcare will issue full credit for the replacement less freight charges.
Product returned without RA number clearly marked on the package or product returned later than 30 days after authorization will be refused and returned at sender’s expense. Final disposition of warranty claims will be determined at the sole discretion of Bestcare. Warranty claims will be denied for any of the following: product abuse or misuse, accidental or malicious damage,
improper installation, product used with parts, components or accessories with quality or specications incompatible with product, adulterated product, user neglect, failure to maintain and service product as specied in the owner’s manual or care tag, serial
number removed or defaced, or normal wear and tear.
Bestcare warrants the following products and components beginning from the purchase invoice date for the specied time period:
WARRANTY PERIOD PRODUCT OR COMPONENT
Three (3) Years Patient lift frame or spreader bar
Two (2) Years
One (1) Year Battery or hydraulic pump
Six (6) Months Reusable fabric slings
Actuator, control box, pendant, charger, weigh scale, Stand Aids ( all components of STA400 & STA450), or
casters excluding normal tread wear
Bestcare Single Patient Specic slings are designed for limited use with one patient and may not be laundered. Bestcare will
replace any disposable sling found to have a manufacturing defect. Normal wear and tear will not be covered under warranty.
This warranty expressly excludes wearable components including but not limited to foam parts and caster tread. Furthermore, this warranty is void and null for product that has not been purchased or paid for in full.
RETURN GOODS POLICY
Patient lifts may not be returned unless the wrong lift is shipped in error by Bestcare or the lift is heavily damaged or defective out of the box. For all other items, purchaser may request a RA for purchased goods within thirty (30) days of purchase invoice date. All returns must be received by Bestcare no later than thirty (30) days after authorization or the RA will be voided. Return package must be clearly marked with the RA number or the package may be refused and returned at sender’s expense. Returns are subject to a minimum restocking fee of 15% or more depending on the condition of the returned item. Patient lifts are subject to a minimum restocking fee of 25% or more. Please note that patient lifts being returned must be in the original carton with all parts, components and packing materials included. Failure to comply with this requirement will incur higher restocking fees or a rejection of the return. Slings, parts and accessories may only be returned if they have not been used. There are no exceptions to this provision.
All freight charges are the sole responsibility of purchaser when any of the following occurs: (i) ordering error where an incorrect item is shipped in accordance with purchase order, (ii) an order is canceled while in transit or (iii) delivery is refused by customer.
22
Page 24
Emergency Lowering Mechanism
Contact your dealer immediately if standard troubleshooting techniques do not correct the failure. Do not attempt to lift until all failure and safety issues have been resolved.
In case of lift failure, please follow the procedures below to safely lower the user.
The Emergency Lowering Device is located at the top of the actuator shaft. It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair. The device consists of a plastic collar ring that should be pulled down and turned clock­wise continually until the patient has been lowered.
NOTE:
THE EMERGENCY LOWERING DEVICE IS INTENDED FOR USE DURING LIFT FAILURE. THIS DEVICE WILL ALLOW LOWERING OF PATIENTS ONLY. PLEASE
CONTACT YOUR DEALER IMMEDIATELY IN CASE OF FAILURE.
23
Page 25
Troubleshooting Guide
The following list of encountered problems and solutions will assist you in determining what may be causing your patient lift not to function as designed. If you have a problem occurring which is not listed below please contact your dealer or technical support for help. Do not attempt to repair or replace components or parts on your lift as this may void your warranty or cause further problems that may result in patient injury. Stop using your lift immediately if it is not functioning correctly or any warning beeps are heard.
I need to re-charge my batteries often or they fail to hold a charge when I charge them.
• Replace the batteries or battery pack as they are at the end of their life cycle
• Batteries should be changed every 18-24 months depending on usage
The actuator will either go up or down but not both
• Replace your hand control as it is at the end of its life cycle
• Your control box may be malfunctioning
There is a grinding sound inside the actuator when lifting
• Replace your actuator as the internal gears are stripped
The actuator stops and starts while lifting or lowering
• Replace the batteries or battery pack as they are at the end of their life cycle
My lift will not operate even though it shows the batteries are charged
• Unplug the AC power cord from the control box as the lift will not work when the control box/ charger is connected to AC Power.
• Check to make sure the hand control is properly inserted all the way into the control box port.
• Check to make sure the actuator plug is properly connected and inserted all the way into the control box
• Your hand control needs to be replaced as it is at the end of its life cycle
If there is a problem you could not solve, please contact your dealer for assistance.
24
Page 26
NOTES
25
Page 27
NOTES
26
Page 28
Bestcare LLC
2920 Pacic Drive
Norcross, GA 30071
Ver 2020.02 www.bestcarellc.com | © 2019 Bestcare LLC
Loading...