Best WP28M48SB, WP28M42SB, WP28M60SB Installation Guide

HB0024
INSTALLATION INSTRUCTIONS
WP28M SERIES
! !
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION
ON PAGES 11 AND 12.
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711 BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
To register your product online or for additional information visit www.BestRangeHoods.com
SV21519 rev. 02
!
WARNING
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn power pack ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
4. Your range hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the range hood serviced.
5. For best capture of cooking impurities, the bottom of the hood
should be at a minimum of 24” and at a maximum of 36” above the cooking surface.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this hood, you
should make sure enough air is entering the house. Use an appropriate make-up air device or open a window close to or in the kitchen.
10. To reduce the risk of fire and electric shock, the Best WP28M
Series hood must be installed with Best interior blower models iQ6, P3, P6, iQ12 or P12; Best exterior blower models EB6, EB9, EB12 or EB15; Best inline blowers models ILB3, ILB6, ILB9, ILB11. Other blowers cannot be substituted. (Blowers sold separately.)
11. Please read specification label on product for further
information and requirements.
2
- WP28M SERIES RANGE HOOD SYSTEMS -
M
ODEL 437
(HIGH CAPACITY ROOF CAP)
M
ODEL 418
(10” ROUND
ADJUSTABLE ELBOW,
OPTIONAL)
INTERIOR BLOWERS
MODEL 441
(10” ROUND WALL CAP)
MODEL 634 OR 644
OOF CAP)
(R
8” ROUND
ADJUSTABLE ELBOW,
OPTIONAL
MODEL 643
OUND WALL CAP)
(8” R
MODEL 410
(10” ROUND DUCT
2 FT. SECTIONS)
M
ODEL 421
(10” ROUND VERTICAL
IN-LINE DAMPER,
INCLUDED WITH IQ12 AND P12
BLOWER/ROUGH-IN KIT)
OPTIONAL
AEWP28 SERIES
DECORATIVE FLUE
8” R
STANDARD
OUND
DUCT
8” R (INCLUDED WITH IQ6, P3
AND P6 BLOWER/ROUGH-IN KIT)
WP28M SERIES HOOD
ANOPY WITH BLOWER
(C
CONTROLS & LIGHTING.
REQUIRED FOR ALL INSTALLATIONS.)
OUND ADAPTER/DAMPER
MODEL iQ12 OR P12
BLOWER/ROUGH-IN KIT
(1200 CFM INTERIOR BLOWER &
ROUGH-IN PLATE)
HL0170
OPTIONAL RMP SERIES
BACKSPLASH
(S
TAINLESS STEEL WALL COVERING
WITH SHELVES)
3
MODEL iQ6, P3 OR P6
BLOWER/ROUGH-IN KIT
(600 CFM (EXCEPT 300 CFM
FOR P3) INTERIOR BLOWER
& ROUGH-IN PLATE)
M
ODEL 643
(8” ROUND
WALL CAP)
M
ODEL ILB3 (280 CFM)
IN-LINE BLOWER
(INCLUDES ONE 8” TO 10”
ROUND TRANSITION)
- WP28M SERIES RANGE HOOD SYSTEMS -
IN-LINE AND EXTERIOR BLOWERS
ODEL 437
M
(HIGH CAPACITY ROOF CAP)
M
ODEL 441
(10” ROUND
CAP)
WALL
MODEL ILB6 (600 CFM)
IN-LINE BLOWER
(INCLUDES TWO 4½” X 18½”
TO 10” ROUND TRANSITIONS)
ADJUSTABLE ELBOW,
M
ODEL ILB9 (800 CFM)
OR ILB11 (1100 CFM)
IN-LINE BLOWER
(INCLUDES TWO 8” X 12” TO
ROUND TRANSITIONS)
10”
M
ODEL 418
(10” ROUND
OPTIONAL)
MODEL 410 (10” ROUND DUCT— 2 FT. SECTIONS)
MODEL 441
(10” ROUND WALL CAP)
MODEL EB6 (600 CFM)
OR EB9 (900 CFM)
EXTERIOR BLOWER
(10” ROUND VERTICAL
IN-LINE DAMPER)
RECOMMENDED FOR USE
WITH EXTERIOR BLOWERS.
MODEL EB12 (1200 CFM)
OR EB15 (1500 CFM)
EXTERIOR BLOWER
MODEL 421
OPTIONAL DECORATIVE FLUE AEWP28 SERIES
WP28M SERIES HOOD
(CANOPY WITH
BLOWER CONTROLS & LIGHTING.
REQUIRED FOR ALL INSTALLATIONS)
IN-LINE AND EXTERIOR
BLOWER ROUGH-IN KIT
(INCLUDED WITH EB6, EB9, EB12, EB15, ILB3, ILB6,
AND ILB11 BLOWERS)
ILB9
OPTIONAL RMP SERIES BACKSPLASH
TAINLESS STEEL WALL COVERING
(S
WITH SHELVES)
L0152
4
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK
Either an interior or exterior blower or in-line blower may be used with this hood. The Best WP28M Series must be installed with blower models iQ6, P3, P6, iQ12, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately.) Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 7, 10 to 12, 15 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct joints. NOTE: It is recommended that there be a minimum of 6” of straight duct from this hood to an elbow for 8” ducting and 12” for 10” ducting.
ROOF CAP
DECORATIVE
FLUE
OR SOFFIT
HOOD
ABOVE COOKING SURFACE
HH0209A
12”
24” TO 36”
MODEL iQ6, P3 OR P6
SINGLE INTERIOR BLOWER
TYPICAL DUCTWORK
EXTERIOR BLOWER
8” ROUND
DUCT
WALL CAP
10” ROUND
DUCT
ROOF CAP
DECORATIVE
FLUE
OR SOFFIT
HOOD
ABOVE COOKING SURFACE
HH0210A
12”
24” TO 36”
MODEL iQ12 OR P12
DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
EXCEPT HLB3, 8’’ ROUND DUCT)
(
10” ROUND DUCT
IN-LINE BLOWER
10” ROUND
DUCT
WALL CAP
ROOF CAP
DECORATIVE
FLUE
OR SOFFIT
HOOD
ABOVE COOKING SURFACE
HH0211A
24”
12”
TO 36”
EXTERIOR BLOWER
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER TYPICAL DUCTWORK
WALL CAP
HOOD
24” TO 36”
ABOVE COOKING SURFACE
HH0212A
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER TYPICAL DUCTWORK
5
2. MEASURE INSTALLATION
!
Dimensions for the most common installation are shown below. Adjust your measurements for various heights of ceiling, soffits, decorative flue, cabinets or cooktops.
The minimum hood distance above cooktop must not be less than 24’’. A maximum of 36” above cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion.
Standard 8 ft.
11 16
ceiling
Top of wood mounting strip
RMP Series Backsplash (optional)
Standard 36” H cooktop
Standard
18” H
over cooktop
cabinet
Hood
HH0021A
24”
Cooktop
18”
19 ”
INSTALLATION WITH STANDARD 18’’ HIGH
OVER COOKTOP CABINET
3. PREPARE THE INSTALLATION
11 16
Standard 8 ft. ceiling
Top of wood mounting strip
RMP Series Backsplash (optional)
Standard 36” H cooktop
Standard 12” soffit
-or-
AEWP28 Series
decorative flue
Hood
HH0216A
36”
Cooktop
12”
13 ”
INSTALLATION WITH STANDARD 12’’ SOFFIT OR
OPTIONAL DECORATIVE FLUE AEWP28 SERIES
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Wood strip (screwed on back of hood)
- Installation manual
- Accessories including:
• Hybrid baffle filters with handles (2 for 30” width, 3 for 36”, 42” and 48” width, 4 for 54” and 60” width)
• Shielded halogen bulbs (GU10 type base, 120 V, 50 W) (2 for hoods up to 36” width, 4 for hoods from 42” to 60” width)
• Bag of parts including: 4 no. 10-2” flat head screws, 8 no. 8 x 3/4” screws, 4 no. 10-32 nuts, 2 wall anchors, 2 washers 3/16” ID x 3/4” OD
Parts sold separately:
- Interior blower model iQ6, P3 or P6 (includes rough-in kit and 8” round adapter and damper)
- Interior blower model iQ12 or P12 (includes rough-in kit and 10” round vertical in-line damper, model 421)
- In-line blower assembly model ILB3, ILB6, ILB9 or ILB11 (all include transition(s) and rough-in plate)
- Exterior blower assembly model EB6, EB9, EB12 or EB15 (all include rough-in plate)
- Duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers.
- Optional decorative flue AEWP28 Series
6
4. INSTALL BACKSPLASH (OPTIONAL)
!
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop.
(See instructions packed with backsplash.)
5. REMOVE HYBRID BAFFLE FILTERS
Remove tape on filters. Remove filters from hood and set aside.
NOTE: It is recommended to start with the center one.
6. INSTALL WOOD MOUNTING STRIP
Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustration under step 2 for dimensions). Remove wood mounting strip from back of hood.
Center wood mounting strip over location. Use no. 10 - 2’’ flat head screws to secure the mounting strip to the drywall. Make sure to hit the wall studs.
WARNING
Due to the weight of this hood, ensure that the wood strip is attached to all of the available studs (2 studs minimum for a 30’’ width hood, more as hood width increases); not into the drywall alone.
HD0547
WOOD STRIP
(CENTERED HORIZONTALLY AND SECURED
TO WALL STUDS OR FRAMING)
LEVEL LINE
(SEE PAG E 6
FOR DIMENSIONS)
HD0046
7
7. INSTALL THE HOOD
Rest the back cavity of the hood on the wood mounting strip.
CAUTION
Hold the hood until it is completely secured to the wood mounting strip.
Secure the hood to wood mounting strip with 4 screws no. 8 x 3/4” (for 30” and 36” width hoods) or 6 screws (for 42” width and wider hoods) provided at locations shown. Drill two 3/16’’ size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install both wall anchors and attach the hood with the remaining no. 8 x 3/4” screws and both washers provided.
HD0047
TOP OF HOOD (INSIDE VIEW)
MOUNTING SCREW LOCATIONS
BACK OF HOOD (INSIDE VIEW)
WALL ANCHOR LOCATIONS
8. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)
INTERIOR BLOWER: Follow all subsequent steps of this manual. EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 10 to 13, then 15 and up of the present manual.
9. ATTACH 8” ROUND ADAPTER AND DAMPER TO ROUGH-IN PLATE
(iQ6, P3 OR P6 INTERIOR BLOWER)
Attach 8” round adapter and damper to iQ6, P3 or P6 blower rough-in plate. Use metal duct tape to make all joints secure and air-tight.
HO0196
8
10. INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL BLOWERS)
!
Run power cable to installation location. Refer to the instructions included with the selected blower/rough-in kit (sold separately) for details on installing the rough-in plate. Attach blower plate to the studs at the inside, top or back of hood with 4 no. 10-32 nuts, provided. Install the rough-in plate so that the wiring box is located on the right side as you are facing the hood.
For ducting through back of hood, remove existing plate from inside back of hood and attach it to inside top of hood to cover hole. Secure to threaded studs with same 4 nuts.
For ducting through top of hood, existing plate remains in place on inside back of hood.
Connect ducting to adapter and damper or rough-in plate (according to blower model) as you are installing the rough-in plate. Use duct tape to make all joints secure and air-tight.
BLOWER PLATE
NO.10-32 NUTS (2 PER SIDE)
HD0048
11. CONNECT THE WIRING (ALL BLOWERS)
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate and set aside. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw. Reinstall wiring cover.
12. INSTALL THE OPTIONAL DECORATIVE FLUE AEWP28 SERIES (ALL BLOWERS)
From inside the hood, attach the optional decorative flue AEWP28 Series to top of hood at sides and front of hood using no. 8 screws (provided).
HD0050
9
13. INSTALL THE BLOWER (INTERIOR OR EXTERIOR BLOWER)
!
Refer to instructions included with blower. Once the blower is installed, plug the power supply to the 3-prong male connector (A)
and the blower unit into the 2-prong female receptacle (B) inside the hood.
WARNING
Do not plug the two cords into each other.
HE0003
14. INSTALL THE CALIBRATION BUTTON BRACKET IN THE HOOD
(iQ6 AND iQ12 INTERIOR BLOWERS ONLY)
A
B
Both iQ6 and iQ12 blowers are equipped with a calibration button already mounted to its own bracket. Install this bracket in the hood, using 2 screws provided with iQ6 or iQ12 interior blower.
See additional details in the iQ6 and iQ12 blower instructions included with the blowers.
HD545
15. REINSTALL BAFFLE FILTERS
CAUTION
Remove protective plastic film covering hybrid baffle filters before reinstalling them.
It is recommended to install side filters first and finish with center one(s). Insert the end with filter spring clip of hybrid baffle filter into the upper channel
of the hood.
Raise the other end toward the inside of hood and insert in the grease drip rail
of the hood.
Replacement filters are available from your dealer. See label inside hood for size and part number.
HD0546
10
16. LIGHT BULBS REPLACEMENT
!
This hood requires 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
WARNING
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroïc lamp, a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
1. To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.
NOTE: To ease removal of the bulbs, use a rubber dishwashing
glove or use suction cup tool available from Best. Contact Best Customer Service at 1-800-558-1711 to order suction cup tool, part no. 99526707.
2. Install the new lamps by placing the bulb leads into their grooves in the socket.
3. Gently push upwards and turn clockwise until secure.
12 3
HO0089
17. USE AND CARE
Hybrid Baffle Filters
The hybrid baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking.
Remove hybrid baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions — but this will not affect filter performance. This discoloration is not covered by the warranty.
Blower Cleaning
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Refer to blower instruction manual for more details.
Hood cleaning
Stainless steel cleaning:
Do:
• Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
• You may also use a specialized household stainless steel cleaner.
Don’t:
• Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the power pack. During construction/renovation, cover the power pack to make sure no dust sticks to stainless steel surface.
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
11
18. OPERATION
!
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1
2
3
HC0038
1) HALOGEN LIGHT KNOB
2) BLOWER SPEED CONTROL KNOB
3) ON/OFF BLOWER SWITCH
COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower operates at the previous setting of the speed
control (2). Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed. HEAT SENTRY™ This hood is equipped with a Heat Sentry™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses
excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
HC0039
1) HALOGEN LIGHT KNOB
2) BLOWER SPEED CONTROL KNOB
AB
WARNING
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the hood is turned off. In this case, it is impossible to turn the blower OFF with blower switch. If you must stop the blower, unplug the blower power cord (located behind the filters) from the hood by pulling on its 2-prong connector; do not pull on the wire.
When the temperature level drops to normal, the blower will return to its original setting.
12
19. WIRING DIAGRAMS
INTERIOR BLOWER
120 VAC
NEUTRAL
GROUND
LINE
BLK G W
BLK
HS
HERMOSTAT
T
BLU BLU
S
FAN SWITCH
W
BLK
W
BLK
PEED CONTROL
ROUGH-IN PLATE
HE0185A
BLK
W
INTERNAL BLOWER ASSEMBLY
W
BLK
M
BLK
LAMP
SWITCH
COLOR CODE
BLK BLACK BLU BLUE G GREEN W WHITE Y YELLOW
BLK
W
W
Y
Y
W
Y
W
Y
LAMP
LAMP
LAMP
LAMP
13
19. WIRING DIAGRAMS (CONT'D)
IN-LINE OR EXTERIOR BLOWER
120 VAC
NEUTRAL
GROUND
LINE
BLK
G W
W
BLK
BLK
W
W
BLK
HS
HERMOSTAT
T
BLU BLU
S
FAN SWITCH
BLK
W
BLK
PEED CONTROL
BLK
OUGH-IN PLATE
R
HE0186A
BLK
BLK
W
G
REMOTE BLOWER ASSEMBLY
M
LAMP
SWITCH
W
W
Y
Y
W
Y
LAMPLAMP
COLOR CODE
BLK BLACK BLU BLUE G GREEN
W
Y
LAMPLAMP
W WHITE Y YELLOW
14
20. WARRANTY
ONE-YEAR LIMITED WARRANTY FOR BEST PRODUCTS
Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan­NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to another. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
In USA - Best In Canada - Best®, 550 Lemire Blvd., Drummondville, QC, Canada, J2C 7W9 (866-737-7770)
®
, 926 W. State Street, Hartford, WI 53027 (800-558-1711)
www.BestRangeHoods.com
15
Loading...
+ 33 hidden pages