Best UP26M48SB, UP26M42SB Installation Guide

INSTALLATION INSTRUCTIONS
HB0029
UP26M SERIES
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14.
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711 BEST; Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
To register your product online or for additional information visit www.BestRangeHoods.com
SV21517 rev. 01
!
WARNING
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
5. For best capture of cooking impurities, the bottom of the hood
should be at a minimum of 24” and at a maximum of 36” above the cooking surface.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen.
10. To reduce the risk of fire and electric shock, the Best UP26M
Series hood must be installed with Best interior blower model iQ6, P3, P5, P6 or P8; Best exterior models EB6, EB9, EB12 or EB15; Best in-line blowers models ILB3, ILB6, ILB9 or ILB11. Other blowers cannot be substituted. (Blowers sold separately.)
11. Use with approved cord-connection kit only.
12. Please read specification label on product for further
information and requirements.
2
- UP26M SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
MODEL 647
(7” ROUND WALL CAP)
ODEL 415
M
7” ROUND
ADJUSTABLE
ELBOW
(OPTIONAL)
ODEL 407
M (7” ROUND— 2 FT SECTIONS)
MODEL 412 TRANSITION (3¼” X 10” TO 7”)
STANDARD
3¼” X 10”
A
DAPTER/DAMPER 3¼” X 10”
(SUPPLIED WITH P5 AND P8
BLOWERS)
(VERTICAL EXHAUST ONLY)
(SUPPLIED WITH P5 AND P8 BLOWERS)
DUCT
FLOW DEVIATOR
MODEL 634 OR 644
(ROOF CAP)
8” ROUND ADJUSTABLE
ELBOW (OPTIONAL)
8” R
STANDARD
MODEL 413 TRANSITION (3¼” X 10” TO 8”)
OUND
DUCT
(8” ROUND WALL CAP)
ODEL 459 TRANSITION
M (3¼” X 14” TO 8”)
A
DAPTER/DAMPER
3¼” X 14” (SUPPLIED WITH P8 BLOWER)
UP26M HOOD
ODEL 643
M
STANDARD 3¼” X 14” DUCT
MODEL 634 OR 644
(ROOF CAP)
MODEL 643
(8” ROUND WALL CAP)
(SUPPLIED WITH P5 AND P8 BLOWERS)
MODEL P5
SINGLE-BLOWER (500 CFM)
BACKSPLASH (RMP SERIES)
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES. OPTIONAL)
OUGH-IN KIT
R
ODEL P8 DUAL-BLOWER (900 CFM)
M FOR USE WITH 36” HOODS OR WIDER
NOTE: The dual blower P8 must
be installed with 3¼” x 14” duct. If it is impossible to connect the dual blower P8 to a 3¼” x 14” duct, use a 3¼” x 10” duct. In that case, the blower performance will be decreased by 25%.
(SUPPLIED WITH P3, P6 AND IQ6 BLOWERS)
8” ROUND ADJUSTABLE
ELBOW (OPTIONAL)
8” ROUND
STANDARD DUCT
8” ROUND ADAPTER/DAMPER (SUPPLIED WITH P3, P6 AND
IQ6 BLOWERS)
UP26M HOOD
ROUGH-IN KIT
HL0220
MODELS P3 (300 CFM), P6 (600 CFM)
OR IQ6 (600 CFM) SINGLE BLOWER
3
- UP26M SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
MODEL 643
(8” ROUND
WALL
CAP)
MODEL ILB3 (280 CFM) IN-LINE BLOWER (INCLUDES ONE 8” TO 10”
ROUND TRANSITION)
M
ODEL 437
IGH CAPACITY ROOF CAP )
(H
ODEL 441
M (10” ROUND
WALL CAP)
MODEL ILB6 (600 CFM)
IN-LINE BLOWER
(INCLUDES TWO 4½” X 18½”
TO 10’’ ROUND TRANSITIONS)
ADJUSTABLE ELBOW)—
ODEL ILB9 (800 CFM)
M
OR ILB11 (1100 CFM)
IN-LINE BLOWER
(INCLUDES TWO 8” X 12” TO
10’’
ROUND TRANSITIONS)
ODEL 418
M
(10” ROUND
OPTIONAL
MODEL 441
(10” R
MODEL 410 (10” ROUND DUCT —2FT. SECTIONS)
OUND WALL CAP)
MODEL EB6 (600 CFM)
OR EB9 (900 CFM)
EXTERIOR BLOWER
(RECOMMENDED FOR USE
WITH EXTERIOR BLOWERS)
MODEL EB12 (1200 CFM)
OR EB15 (1500 CFM)
EXTERIOR BLOWER
MODEL 421
(10” ROUND VERT.
IN-LINE DAMPER)
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL
COVERING WITH WARMING
SHELVES. OPTIONAL)
UP26M
HOOD
N-LINE AND EXTERIOR BLOWER ROUGH-IN KIT
I (INCLUDED WITH EB6, EB9, EB12, EB15,
ILB3, ILB6, ILB9 AND ILB11 BLOWERS).
HL0071
4
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK
x 10 OR 3¼ x 14
HH0213A
Either an interior or exterior blower or in-line blower may be used with this hood. The Best UP26M must be installed with blower models iQ6, P3, P5, P6, P8, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 5, 8, 11, 12, 16 and up of this manual.
Install proper-sized ductwork, elbow(s) and roof or wall cap for the type of blower you are installing. If using 7” or 8” round ducts, use a transition. Use 2” metal foil duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24”. A maximum of 36” above cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion.
ROOF CAP
WALL CAP
HOOD
24” TO 36”
ABOVE COOKING SURFACE
MODEL P5 (SINGLE) OR P8 (DOUBLE)
INTERIOR BLOWER
TYPICAL RECTANGULAR DUCTWORK
EXTERIOR BLOWER
EXTERIOR BLOWER
10” ROUND DUCT
ROOF CAP
7” OR 8”
WALL CAP
HH0214A
ROUND DUCT
3¼” X 10” TO 7” OR 8” TRANSITION
X 14” TO 8”
OR 3¼” TRANSITION
HOOD
24” TO 36”
ABOVE COOKING SURFACE
MODEL P5 (SINGLE) OR P8 (DOUBLE)
INTERIOR BLOWER
7 OR 8 ROUND DUCTWORK
(
EXCEPT HLB3, 8’’ ROUND DUCT)
ROOF CAP
WALL CAP
HH0215A
ABOVE COOKING SURFACE
8” ROUND DUCT
24” TO 36”
MODEL P3, P6 or iQ6 (SINGLE)
INTERIOR BLOWER
8 ROUND DUCTWORK
10” ROUND DUCT
IN-LINE BLOWER
HOOD
ROOF CAP
HOOD
24” TO 36”
ABOVE COOKING SURFACE
HH0217A
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER
TYPICAL DUCTWORK
WALL CAP
HOOD
ABOVE COOKING SURFACE
HH0212A
24” TO 36”
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER
TYPICAL DUCTWORK
5
2. PREPARE INSTALLATION
!
A
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included:
- Range hood
- Accessories: • Hybrid baffle filters with handles
• Shielded halogen bulbs (120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base)
• Bag of parts including: 4 lock nuts no. 10-32, 1 wire clamp LP16-AP, 2 no. 6 x 1/2” screws,
Parts sold separately:
• Interior blower Model P5 or P8 includes blower, rough-in kit, flow deviator and 3¼” x 10” or 3¼” x 14” adapter
• Interior blower Model iQ6, P3 or P6 includes blower, rough-in kit, adapter/damper
• In-line blower assembly ILB3, ILB6, ILB9 or ILB11 (all include transition(s) and rough-in plate)
• Exterior blower assembly EB6, EB9, EB12 or EB15 (all include rough-in plate)
• Backsplash (optional)
• Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers. NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below. Use two 2-inch wide
strips for 30” wide hoods, and four 2-inch wide strips for wider hoods, cut to length. See below for wood filler strip locations.
2 wire connectors no. 74B, 6 no. 8 x 3/8”, 8 double threaded screws 6-12 x 1/2”
HOOD
WIDTHS
30” 2” N/A N/A 36” 2” 4½” 4½” 42” 2” 7¼” 8¼” 48" 4” 10¼” 11¼”
LOCATIONS
ABC
A
HD0079
B C
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, ensure to have at least 18” clearance between bottom of hood and range control panel or cooktop. (See instructions packed with backsplash.)
4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)
INTERIOR BLOWER: Follow all subsequent steps of this manual. EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 5, 8, 11,12, 16 and up of the present manual.
6
5. REMOVE FILTERS AND BOTTOM PANEL (ALL BLOWERS)
Lay the hood flat on a table. Use a piece of cardboard to avoid damaging the table or the hood.
Remove tape on filters. Remove filters from hood and set aside. NOTE: It is recommended to start with the center one(s).
HD0544
Remove bottom panel both retaining screws. Set bottom panel and screws aside.
RETAINING SCREWS
BOTTOM PANEL
1
3
2
HD0541
HD0542
6. CHOOSE THE OPENING (P5 AND P8 BLOWERS ONLY)
Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below.
CAUTION
If using P5 blower, remove 10 wide knockout. If using P8 blower, remove either 10 or 14 wide knockout.
14KNOCKOUT
10KNOCKOUT
HD0076
Removing horizontal knockout opening on back of hood.
HD0077
KNOCKOUT
14
KNOCKOUT
10
Removing vertical knockout opening on rough-in plate.
7
7. INSTALL THE ADAPTER/DAMPER (P3, P6 AND IQ6 BLOWERS ONLY)
Attach 8” round adapter/damper to blower rough-in plate. Use metal duct tape to make all joints secure and air-tight.
HO0196
8. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
BLOWER PLATE
INTERIOR BLOWER: Secure the rough-in plate (provided with the
blower) inside the hood with four lock nuts. See picture at right.
EXTERIOR OR IN-LINE BLOWER: Refer to instructions included with
exterior or in-line blower rough-in kit. Secure the rough-in plate inside the hood with four lock nuts.
HD0048
9. INSTALL THE DEVIATOR (P5 AND P8 BLOWERS, VERTICAL INSTALLATION ONLY)
LOCK NUTS
YOU MUST install the deviator if you choose to vent the hood vertically. Install the deviator as
shown. NOTE: If installed correctly, the deviator will protrude about 1/8” above the rough-in plate.
HD0003
Inserting deviator into hood vertical opening.
10. INSTALL THE ADAPTER (P5 AND P8 BLOWERS ONLY)
Using provided screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using metal foil duct tape. NOTE: For vertical exhaust, ensure that the damper pivot is located towards the front of the hood.
HD0005 HD0006
8
!
11. INSTALL THE HOOD (ALL BLOWERS)
INTERIOR BLOWER
Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely.
HD0043
IN-LINE OR EXTERIOR BLOWER
Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see instructions included with exterior blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely.
12. CONNECT WIRING (ALL BLOWERS)
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally.
INTERIOR BLOWER: Connect cable into wiring box using wire connectors. Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under ground screw. Reinstall wiring cover.
DO NOT FORGET TO CONNECT THE GROUND.
HE0012
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included with in-line or
exterior blower).
GROUND SCREW
9
13. INSTALL THE BLOWER (P5 AND P8 BLOWERS ONLY)
The blower must be installed to the rough-in plate using four 3/8” screws. Remove the cover from the blower assembly. Remove the impeller(s) by pulling it (them) out gently (see pictures below).
HD0021
HD0022
Install screws into the location as shown in the pictures below (P5 or P8 blower). Do not tighten screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the screws.
HD0044
P5 BLOWER
HD0045
P8 BLOWER
Secure the blower by installing 2 more screws into the locations shown in the pictures below (P5 or P8 blower). Reinstall impeller(s) and cover.
HD0080
FOR P8 DUAL BLOWER UNIT, ENSURE THE IMPELLERS ARE CORRECTLY INSTALLED; THE HOOD WILL NOT WORK PROPERLY IF REVERSED. Both impellers are different in the dual blower, one rotates clockwise and the other counterclockwise. Each wheel and motor have an arrow and a number on them, you have to match them correctly (see drawing at right).
HD0023
10
HD0081
1
FRONT
HD0023
21
2
13. INSTALL THE BLOWER (P5 AND P8 BLOWERS ONLY) (CONT'D)
!
!
Plug the power supply to the 3-prong male connector (A) and the blower unit into the 2-prong female receptacle (B) inside the hood.
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply cord.
HE0003
14. INSTALL THE BLOWER (P3, P6, IQ6 AND EXTERIOR BLOWERS ONLY)
Refer to instructions included with blower. Once the blower is installed, plug the power supply to the 3-prong male connector (A)
and the blower unit into the 2-prong female receptacle (B) inside the hood.
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply cord.
A
B
A
B
HE0003
15. INSTALL THE CALIBRATION BUTTON BRACKET IN THE HOOD
(iQ6 INTERIOR BLOWER ONLY)
The iQ6 blower is equipped with a calibration button already mounted to its own bracket. Install this bracket in the hood, using 2 screws provided with iQ6 interior blower.
See additional details in the iQ6 blower instructions included with the blower.
HD0007
11
16. REINSTALL BOTTOM PANEL AND HYBRID BAFFLE FILTERS
!
CAUTION
Remove protective plastic film covering filters before installing them.
Reinstall bottom panel using both retaining screws removed in step 5. Reinstall filters. It is recommended to install side filters first and finish with center one(s).
Insert the end with filter spring clip of hybrid baffle filter into the upper channel of the hood. Raise the other end toward the inside and insert in the grease drip rail of the hood.
Replacement filters are available from your dealer. See label inside hood for part number.
1
HD0543
2
17. LIGHT BULBS REPLACEMENT
This hood requires 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
WARNING
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroïc lamp, a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
1. To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.
NOTE: To ease removal of the bulbs, use a rubber dishwashing
glove or use suction cup tool available from Best. Contact Best Customer Service at 1-800-558-1711 to order suction cup tool, part no. 99526707.
2. Install the new lamps by placing the bulb leads into their grooves in the socket.
3. Gently push upwards and turn clockwise until secure.
12 3
HO0089
12
18. USE AND CARE
Hybrid baffle filters and impeller(s)*
The hybrid baffle filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease — like frying foods or wok cooking.
Remove filters by pushing filters towards the front of hood and rotating filters downward. Hybrid baffle filters and impeller(s) are dishwasher safe.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions — but this will not affect filter performance. This discoloration is not covered by the warranty.
* Impeller(s) only on P5 and P8 blowers.
Hood cleaning
Stainless steel cleaning:
Do:
• Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
• You may also use a specialized household stainless steel cleaner.
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
Don’t:
• Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to make sure no dust sticks to stainless steel surface.
13
19. OPERATION
!
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1
2
3
HC0038
1) HALOGEN LIGHT KNOB
2) BLOWER SPEED CONTROL KNOB
3) ON/OFF BLOWER SWITCH
COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower operates at the previous setting of the speed
control (2). Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.
HEAT SENTRY™ This hood is equipped with a Heat Sentry™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses
excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
HC0039
1) HALOGEN LIGHT KNOB
2) BLOWER SPEED CONTROL KNOB
AB
WARNING
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the hood is turned off. In this case, it is impossible to turn the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.
When the temperature level drops to normal, the blower will return to its original setting.
14
20. WIRING DIAGRAMS
INTERIOR BLOWER
120 VAC
NEUTRAL
GROUND
LINE
BLK G W
BLK
HS
HERMOSTAT
T
BLU BLU
S
FAN SWITCH
W
BLK
W
BLK
PEED CONTROL
ROUGH-IN PLATE
HE0187A
BLK
W
INTERNAL BLOWER ASSEMBLY
W
BLK
M
BLK
LAMP
SWITCH
COLOR CODE
BLK BLACK BLU BLUE G GREEN W WHITE Y YELLOW
BLK
W
W
Y
Y
W
Y
LAMP
LAMP
LAMP
15
20. WIRING DIAGRAMS (CONT'D)
IN-LINE OR EXTERIOR BLOWER
120 VAC
GROUND
LINE
OUGH-IN PLATE
R
HE0188A
NEUTRAL
BLK
G W
W
BLK
HS
HERMOSTAT
T
BLU BLU
S
FAN SWITCH
BLK
W
W
BLK
BLK
W
G
REMOTE BLOWER ASSEMBLY
M
BLK
W
BLK
LAMP
SWITCH
W
BLK
Y
W
W
PEED CONTROL
BLK
LAMPLAMP
Y
Y
COLOR CODE
BLK BLACK
LAMP
BLU BLUE G GREEN W WHITE Y YELLOW
16
21. SERVICE PARTS
Model UP26M
2
3
4
5
6
7
8
10
11
1
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone genuine replacement parts only. Broan-NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone recommends to contact a certified service depot for all replacement parts and repairs.
12
13
14
15
HL0221
KEY
PART NO.DESCRIPTION
NO.
1 SV05869 BEST LOGO 1111
SV13431 HYBRID BAFFLE FILTER 8.84" X 8.61" (INCLUDING HANDLE)-31-
2
SV13432 HYBRID BAFFLE FILTER 11.84" X 8.61" (INCLUDING HANDLE) 2-23 SV61691 F
3
SV61679 FILTER FILLER 3" (PAIR) ---1 SV61742 GREASE RAIL 30" 1--­SV61743 G
4
SV61744 G
SV61745 GREASE RAIL 48" ---1 5 SV05917 S 6 SV09435 S 7 SV09434 LIGHT TRIM, STAINLESS STEEL 2233 8 SV05921 SHIELDED HALOGEN BULBS (50 W, 120 V, PAR16, GU10) 2233 9 SV08578 B
10 SV03435 THERMOSTAT 1111
11 SV08338 LIGHT SWITCH 1111 12 SV03501 SPEED CONTROL 1111 13 SV08548 BLOWER ROCKER SWITCH 1111 14 SV12516 FEMALE CONNECTOR 1111 15 SV07398 MALE CONNECTOR 1111
* SV17645 THERMOSTAT BRACKET 1111 * SV21517 INSTALLATION GUIDE 1111
* SV13278
ILTER FILLER 1.6" (PAIR)-11-
REASE RAIL 36" -1-- REASE RAIL 42" --1-
OCKET GU10 2233 OCKET HOLDER GU10 2233
LOWER AND LIGHT KNOBS (2 KNOBS) 1111
PARTS BAG: 4 LOCK NUTS NO. 10-32, 1 WIRE CLAMP LP16-AP, 2 NO. 6 X 1/2” SCREWS,
2 WIRE CONNECTORS NO. 74B, 6 NO. 8 X 3/8”, 8 DOUBLE THREADED SCREWS 6-12 X 1/2”
9
QTY. (HOOD WIDTH)
30" 36" 42" 48"
1111
* NOT SHOWN.
17
21. SERVICE PARTS (CONT'D)
SINGLE BLOWER/ROUGH-IN (Model P5)
1
20
2
23
21
22
9
HL0021
3
19
4
18
17
5
5
6
8
7
16
6
15
13
12
14
10
11
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone genuine replacement parts only. Broan-NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone recommends to contact a certified service depot for all replacement parts and repairs.
KEY NO.PART NO.DESCRIPTION QTY.
1 SV13296 ADAPTER/DAMPER 3¼” X 10” 1 2 SV03500 AIR DEFLECTOR 1 3 SV12997 SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY 1 4 SV03577 FOAM 1/2” X 1/2” X 12” 1 5 SV02160 CAPACITOR 15 µF 1 6*M 7 SV01857 WIRE COVER 1 8*LOCK NUT NO. 6-32 1
9 SV14973 SINGLE BLOWER ASSEMBLY 1 10 SV01810 IMPELLER RING 1 11 SV03400 BLOWER IMPELLER 7.094” X 3.375” CW 1 12 SV01766 MOTOR 165 W CW 1 13 * WASHER 3/16” ID X 3/4” OD 3 14 SV02001 MOTOR GROMMET G-431-1 3
*8 TIE WRAP 2
15 SV11705 M
*W 16 SV01927 METRIC SCREW M4 X 6 MM PAN QUADREX 4 17 SV03495 STRAIN RELIEF FOR BLOWER POWER CORD 1 18 SV03494 36” BLOWER POWER CORD 1 19 SV13230 OUTLET BOX COVER 1 20 SV03496 POWER CORD, 120 VOLTS 1 21 SV00660 STRAIN RELIEF FOR POWER CORD 1 22 * SCREW NO. 8 X 3/8”, T/B, NO. 8 HEAD 2 23 * SCREW NO. 10-32 X 3/8”, TF, GREEN 2
* STANDARD HARDWAREMAY BE PURCHASED LOCALLY.
ACHINE SCREW NO. 6-32 X 1/4” 4
OTOR MOUNT 1
IRE NO. 18 TEW BROWN X 10” 1
18
Loading...