To register your product online or for additional information visit www.BestRangeHoods.com
SV21517 rev. 03
!
WARNING
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the hood serviced.
5. For best capture of cooking impurities, the bottom of the hood
should be at a minimum of 24” and at a maximum of 36” above
the cooking surface.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
10. To reduce the risk of fire and electric shock, the Best UP26M
Series hood must be installed with Best interior blower model
iQ6, P3, P5, P6 or P8; Best exterior models EB6, EB9, EB12
or EB15; Best in-line blowers models ILB3, ILB6, ILB9 or
ILB11. Other blowers cannot be substituted. (Blowers sold
separately.)
11. Please read specification label on product for further
information and requirements.
2
- UP26M SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
MODEL 647
(7” ROUNDWALLCAP)
ODEL 415
M
7” ROUND
ADJUSTABLE
ELBOW
(OPTIONAL)
ODEL 407
M
(7” ROUND—
2 FTSECTIONS)
MODEL 412
TRANSITION
(3¼” X 10” TO 7”)
STANDARD
3¼” X 10”
A
DAPTER/DAMPER 3¼” X 10”
(SUPPLIEDWITH P5 AND P8
BLOWERS)
(VERTICALEXHAUSTONLY)
(SUPPLIEDWITH P5 AND P8 BLOWERS)
DUCT
FLOWDEVIATOR
MODEL 634 OR 644
(ROOFCAP)
8” ROUNDADJUSTABLE
ELBOW (OPTIONAL)
8” R
STANDARD
MODEL 413
TRANSITION
(3¼” X 10” TO 8”)
OUND
DUCT
(8” ROUNDWALLCAP)
ODEL 459 TRANSITION
M
(3¼” X 14” TO 8”)
A
DAPTER/DAMPER
3¼” X 14”
(SUPPLIEDWITH P8 BLOWER)
UP26M HOOD
ODEL 643
M
STANDARD
3¼” X 14” DUCT
MODEL 634 OR 644
(ROOFCAP)
MODEL 643
(8” ROUNDWALLCAP)
(SUPPLIEDWITH P5 AND P8 BLOWERS)
MODEL P5
SINGLE-BLOWER (500 CFM)
BACKSPLASH (RMP SERIES)
(STAINLESSSTEELWALLCOVERING
WITHWARMINGSHELVES. OPTIONAL)
OUGH-INKIT
R
ODEL P8 DUAL-BLOWER (900 CFM)
M
FORUSEWITH 36” HOODSORWIDER
NOTE: The dual blower P8 must
be installed with 3¼” x 14”
duct. If it is impossible to
connect the dual blower P8
to a 3¼” x 14” duct, use a
3¼” x 10” duct. In that case,
the blower performance will
be decreased by 25%.
(SUPPLIEDWITH P3, P6 ANDIQ6 BLOWERS)
MODEL 432
8” ROUNDADJUSTABLE
ELBOW (OPTIONAL)
MODEL 408
8” ROUND
STANDARDDUCT
MODEL 438
8” ROUNDADAPTER/DAMPER
(SUPPLIEDWITH P3, P6 AND
IQ6 BLOWERS)
UP26M HOOD
ROUGH-INKIT
HL0220
MODELS P3 (300 CFM), P6 (600 CFM)
ORIQ6 (600 CFM) SINGLEBLOWER
3
- UP26M SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
MODEL 643
(8” ROUND
WALL
CAP)
MODEL ILB3 (280 CFM)
IN-LINEBLOWER
(INCLUDESONE 8” TO 10”
ROUNDTRANSITION)
M
ODEL 437
IGHCAPACITYROOFCAP )
(H
ODEL 441
M
(10” ROUND
WALLCAP)
MODEL ILB6 (600 CFM)
IN-LINEBLOWER
(INCLUDESTWO 4½” X 18½”
TO 10’’ ROUNDTRANSITIONS)
ADJUSTABLEELBOW)—
ODEL ILB9 (800 CFM)
M
OR ILB11 (1100 CFM)
IN-LINEBLOWER
(INCLUDESTWO 8” X 12” TO
10’’
ROUNDTRANSITIONS)
ODEL 418
M
(10” ROUND
OPTIONAL
MODEL 441
(10” R
MODEL 410
(10” ROUNDDUCT
—2FT. SECTIONS)
OUNDWALLCAP)
MODEL EB6 (600 CFM)
OR EB9 (900 CFM)
EXTERIORBLOWER
(RECOMMENDEDFORUSE
WITHEXTERIORBLOWERS)
MODEL EB12 (1200 CFM)
OR EB15 (1500 CFM)
EXTERIORBLOWER
MODEL 421
(10” ROUNDVERT.
IN-LINEDAMPER)
RMP SERIES BACKSPLASH
(STAINLESS STEELWALL
COVERINGWITHWARMING
SHELVES. OPTIONAL)
UP26M
HOOD
N-LINEANDEXTERIORBLOWERROUGH-INKIT
I
(INCLUDEDWITH EB6, EB9, EB12, EB15,
ILB3, ILB6, ILB9 AND ILB11 BLOWERS).
HL0071
4
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK
3¼” x 10”
OR 3¼” x 14”
HH0213A
Either an interior or exterior blower or in-line blower may be used with this hood. The Best UP26M must be installed with blower models iQ6,
P3, P5, P6, P8, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 5, 8, 11, 12, 16 and up of this
manual.
Install proper-sized ductwork, elbow(s) and roof or wall cap for the type of blower you are installing. If using 7” or 8” round ducts, use a
transition. Use 2” metal foil duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24”. A maximum of 36” above cooktop is highly recommended
for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion.
ROOF CAP
WALL
CAP
HOOD
24” TO 36”
ABOVE COOKING SURFACE
MODEL P5 (SINGLE) OR P8 (DOUBLE)
INTERIOR BLOWER
TYPICAL RECTANGULAR DUCTWORK
EXTERIOR BLOWER
EXTERIOR
BLOWER
10” ROUND DUCT
ROOF CAP
7” OR 8”
WALL
CAP
HH0214A
ROUND DUCT
3¼” X 10” TO 7”
OR 8” TRANSITION
X 14” TO 8”
OR 3¼”
TRANSITION
HOOD
24” TO 36”
ABOVE COOKING SURFACE
MODEL P5 (SINGLE) OR P8 (DOUBLE)
INTERIOR BLOWER
7” OR 8” ROUND DUCTWORK
(
EXCEPT HLB3, 8’’ ROUND DUCT)
ROOF CAP
WALL
CAP
HH0215A
ABOVE COOKING SURFACE
8” ROUND DUCT
24” TO 36”
MODEL P3, P6 or iQ6 (SINGLE)
INTERIOR BLOWER
8” ROUND DUCTWORK
10” ROUND DUCT
IN-LINE BLOWER
HOOD
ROOF CAP
HOOD
24” TO 36”
ABOVE COOKING SURFACE
HH0217A
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER
TYPICAL DUCTWORK
WALL
CAP
HOOD
ABOVE COOKING SURFACE
HH0212A
24” TO 36”
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER
TYPICAL DUCTWORK
5
2. PREPARE INSTALLATION
!
A
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Make sure that the following items are included:
- Range hood
- Accessories: • Hybrid baffle filters with handles
• Shielded halogen bulbs (120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base)
• Bag of parts including: 4 lock nuts no. 10-32, 1 wire clamp LP16-AP, 2 no. 6 x 1/2” screws,
Parts sold separately:
• Interior blower Model P5 or P8 includes blower, rough-in kit, flow deviator and 3¼” x 10” or 3¼” x 14” adapter
• Interior blower Model iQ6, P3 or P6 includes blower, rough-in kit, adapter/damper
• In-line blower assembly ILB3, ILB6, ILB9 or ILB11 (all include transition(s) and rough-in plate)
• Exterior blower assembly EB6, EB9, EB12 or EB15 (all include rough-in plate)
• Backsplash (optional)
• Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers.
NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below. Use two 2-inch wide
strips for 30” wide hoods, and four 2-inch wide strips for wider hoods, cut to length. See below for wood filler strip locations.
2 wire connectors no. 74B, 6 no. 8 x 3/8”, 8 double threaded screws 6-12 x 1/2”
HOOD
WIDTHS
30”2”N/AN/A
36”2”4½”4½”
42”2”7¼”8¼”
48"4”10¼”11¼”
LOCATIONS
ABC
A
HD0079
BC
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be
able to install the backsplash, ensure to have at least 18” clearance between bottom of hood and range control panel or cooktop. (See
instructions packed with backsplash.)
4. SELECT BLOWER OPTION (EXTERIORORINTERIOR)
INTERIOR BLOWER: Follow all subsequent steps of this manual.
EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 5, 8, 11,12, 16 and up of the present manual.
6
5. REMOVE FILTERS AND BOTTOM PANEL (ALLBLOWERS)
Lay the hood flat on a table. Use a piece of cardboard to avoid
damaging the table or the hood.
Remove tape on filters. Remove filters from hood and set aside.
NOTE: It is recommended to start with the center one(s).
HD0544
Remove bottom panel both retaining screws. Set bottom panel and screws aside.
RETAININGSCREWS
BOTTOM PANEL
1
3
2
HD0541
HD0542
6. CHOOSE THE OPENING (P5 AND P8 BLOWERSONLY)
Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below.
CAUTION
If using P5 blower, remove 10” wide knockout. If using P8 blower, remove either 10” or 14” wide knockout.
14” KNOCKOUT
10” KNOCKOUT
HD0076
Removing horizontal knockout opening on back of hood.
HD0077
KNOCKOUT
”
14
KNOCKOUT
10”
Removing vertical knockout opening on rough-in plate.
7
7. INSTALL THE ADAPTER/DAMPER (P3, P6 ANDIQ6 BLOWERSONLY)
Attach 8” round adapter/damper to blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.
HO0196
8. INSTALL THE ROUGH-IN PLATE (ALLBLOWERS)
BLOWERPLATE
INTERIOR BLOWER: Secure the rough-in plate (provided with the
blower) inside the hood with four lock nuts. See
picture at right.
EXTERIOR OR IN-LINE BLOWER: Refer to instructions included with
exterior or in-line blower rough-in kit.
Secure the rough-in plate inside the
hood with four lock nuts.
HD0048
9. INSTALL THE DEVIATOR (P5 AND P8 BLOWERS, VERTICALINSTALLATIONONLY)
LOCKNUTS
YOU MUST install the deviator if you choose to vent the hood vertically. Install the deviator as
shown.
NOTE: If installed correctly, the deviator will protrude about 1/8” above the rough-in plate.
HD0003
Inserting deviator into hood vertical opening.
10. INSTALL THE ADAPTER (P5 AND P8 BLOWERSONLY)
Using provided screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using metal foil duct tape.
NOTE: For vertical exhaust, ensure that the damper pivot is located towards the front of the hood.
HD0005HD0006
8
!
11. INSTALL THE HOOD (ALLBLOWERS)
INTERIOR BLOWER
Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes)
with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring
cover, place the wire clamp, insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the
cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting. Secure the hood by tightening the screws
completely.
HD0043
IN-LINE OR EXTERIOR BLOWER
Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes)
with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring
cover on top of the hood and connect wiring (see instructions included with exterior blower). Place the hood under the cabinet and
slide it in position. Secure the hood by tightening the screws completely.
12. CONNECT WIRING (ALLBLOWERS)
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
INTERIOR BLOWER: Connect cable into wiring box using wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under ground screw. Reinstall wiring cover.
DO NOT FORGET TO CONNECT THE GROUND.
HE0012
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included with in-line or
exterior blower).
GROUNDSCREW
9
13. INSTALL THE BLOWER (P5 AND P8 BLOWERSONLY)
The blower must be installed to the rough-in plate using four 3/8” screws. Remove the cover from the blower assembly. Remove the
impeller(s) by pulling it (them) out gently (see pictures below).
HD0021
HD0022
Install screws into the location as shown in the pictures below (P5 or P8 blower). Do not tighten screws down fully, leave a 1/8” gap. Hang
blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the
keyhole). Tighten the screws.
HD0044
P5 BLOWER
HD0045
P8 BLOWER
Secure the blower by installing 2 more screws into the locations shown in the pictures below (P5 or P8 blower). Reinstall impeller(s) and
cover.
HD0080
FOR P8 DUAL BLOWER UNIT, ENSURE THE IMPELLERS
ARE CORRECTLY INSTALLED; THE HOOD WILL NOT
WORK PROPERLY IF REVERSED. Both impellers are
different in the dual blower, one rotates clockwise and the other
counterclockwise. Each wheel and motor have an arrow and
a number on them, you have to match them correctly (see
drawing at right).
HD0023
10
HD0081
1
FRONT
HD0023
21
2
13. INSTALL THE BLOWER (P5 AND P8 BLOWERSONLY) (CONT'D)
!
!
Plug the power supply to the 3-prong male connector (A) and the blower unit into
the 2-prong female receptacle (B) inside the hood.
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply
cord.
HE0003
14. INSTALL THE BLOWER (P3, P6, IQ6 ANDEXTERIORBLOWERSONLY)
Refer to instructions included with blower.
Once the blower is installed, plug the power supply to the 3-prong male connector (A)
and the blower unit into the 2-prong female receptacle (B) inside the hood.
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply
cord.
A
B
A
B
HE0003
15. INSTALL THE CALIBRATION BUTTON BRACKET IN THE HOOD
(iQ6 INTERIOR BLOWER ONLY)
The iQ6 blower is equipped with a calibration button already mounted to its own bracket. Install
this bracket in the hood, using 2 screws provided with iQ6 interior blower.
See additional details in the iQ6 blower instructions included with the blower.
HD0007
11
16. REINSTALL BOTTOM PANEL AND HYBRID BAFFLE FILTERS
!
CAUTION
Remove protective plastic film covering filters before installing them.
Reinstall bottom panel using both retaining screws removed in step 5.
Reinstall filters. It is recommended to install side filters first and finish with center one(s).
Insert the end with filter spring clip of hybrid baffle filter into the upper channel of the hood.
Raise the other end toward the inside and insert in the grease drip rail of the hood.
Replacement filters are available from your dealer. See label inside hood for part number.
1
HD0543
2
17. LIGHT BULBS REPLACEMENT
This hood requires 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
WARNING
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury,
only install shielded halogen lamps. Also, never install a cool beam, a dichroïc lamp, a lamp not suitable for use in
recessed luminaires or identified for use in enclosed fixtures.
1. To remove lamps, gently push upwards and turn counterclockwise to
disengage bulb leads from their grooves.
NOTE: To ease removal of the bulbs, use a rubber dishwashing
glove or use suction cup tool available from Best. Contact
Best Customer Service at 1-800-558-1711 to order suction
cup tool, part no. 99526707.
2. Install the new lamps by placing the bulb leads into their grooves in
the socket.
3. Gently push upwards and turn clockwise until secure.
123
HO0089
12
18. USE AND CARE
Hybrid baffle filters and impeller(s)*
The hybrid baffle filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution. Wash more often if your
cooking style generates greater grease — like frying foods or wok cooking.
Remove filters by pushing filters towards the front of hood and rotating filters downward. Hybrid baffle filters and impeller(s) are dishwasher
safe.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent
or as a result of local water conditions — but this will not affect filter performance. This discoloration is not covered by the warranty.
* Impeller(s) only on P5 and P8 blowers.
Hood cleaning
Stainless steel cleaning:
Do:
• Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
• You may also use a specialized household stainless steel
cleaner.
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
Don’t:
• Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the hood to make
sure no dust sticks to stainless steel surface.
13
19. OPERATION
!
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the
air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1
2
3
HC0038
1) HALOGENLIGHTKNOB
2) BLOWERSPEEDCONTROLKNOB
3) ON/OFF BLOWERSWITCH
COOKTOP LIGHTING (HALOGEN)
A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity).
BLOWER
The blower is operated using two controls.
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower operates at the previous setting of the speed
control (2).
Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.
HEAT SENTRY™
This hood is equipped with a Heat Sentry™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses
excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
HC0039
1) HALOGENLIGHTKNOB
2) BLOWERSPEEDCONTROLKNOB
AB
WARNING
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the hood
is turned off. In this case, it is impossible to turn the blower OFF with blower switch. If you must stop the blower,
unplug the blower power cord (located behind the filters) from the hood by pulling on its 2-prong connector; do
not pull on the wire.
When the temperature level drops to normal, the blower will return to its original setting.
14
20. WIRING DIAGRAMS
INTERIOR BLOWER
120 VAC
NEUTRAL
GROUND
LINE
BLK
G
W
BLK
HS
HERMOSTAT
T
BLUBLU
S
FAN SWITCH
W
BLK
W
BLK
PEED CONTROL
ROUGH-IN PLATE
HE0187A
BLK
W
INTERNAL BLOWER ASSEMBLY
W
BLK
M
BLK
LAMP
SWITCH
COLOR CODE
BLK BLACK
BLU BLUE
G GREEN
W WHITE
Y YELLOW
BLK
W
W
Y
Y
W
Y
LAMP
LAMP
LAMP
15
20. WIRING DIAGRAMS (CONT'D)
IN-LINE OR EXTERIOR BLOWER
120 VAC
GROUND
LINE
OUGH-IN PLATE
R
HE0188A
NEUTRAL
BLK
G
W
W
BLK
HS
HERMOSTAT
T
BLUBLU
S
FAN SWITCH
BLK
W
W
BLK
BLK
W
G
REMOTEBLOWERASSEMBLY
M
BLK
W
BLK
LAMP
SWITCH
W
BLK
Y
W
W
PEED CONTROL
BLK
LAMPLAMP
Y
Y
COLOR CODE
BLK BLACK
LAMP
BLU BLUE
G GREEN
W WHITE
Y YELLOW
16
21. SERVICE PARTS
Model UP26M
2
3
4
5
6
7
8
10
11
1
REPLACEMENT PARTSAND REPAIRS
In order to ensure your unit remains in
good working condition, you must use
Broan-NuTone genuine replacement
parts only. Broan-NuTone genuine
replacement parts are specially
designed for each unit and are
manufactured to comply with all the
applicable certification standards and
maintain a high standard of safety.
Any third party replacement part
used may cause serious damage and
drastically reduce the performance
level of your unit, which will result
in premature failing. Broan-NuTone
recommends to contact a certified
service depot for all replacement
parts and repairs.
12
13
14
15
HL0221
KEY
PARTNO.DESCRIPTION
NO.
1SV05869 BESTLOGO1111
SV61639HYBRIDBAFFLEFILTER 8.84" X 8.61" (INCLUDINGHANDLE)-31-
2
SV61640HYBRIDBAFFLEFILTER 11.84" X 8.61" (INCLUDINGHANDLE)2-23
SV61691F
2 WIRECONNECTORSNO. 74B, 6 NO. 8 X 3/8”, 8 DOUBLETHREADEDSCREWS 6-12 X 1/2”
9
QTY. (HOODWIDTH)
30"36" 42" 48"
1111
* NOTSHOWN.
17
21. SERVICE PARTS (CONT'D)
SINGLE BLOWER/ROUGH-IN
(Model P5)
1
20
2
23
21
22
9
HL0021
3
19
4
18
17
5
5
6
8
7
16
6
15
13
12
14
10
11
REPLACEMENT PARTSAND REPAIRS
In order to ensure your unit remains in
good working condition, you must use
Broan-NuTone genuine replacement
parts only. Broan-NuTone genuine
replacement parts are specially
designed for each unit and are
manufactured to comply with all the
applicable certification standards and
maintain a high standard of safety.
Any third party replacement part
used may cause serious damage and
drastically reduce the performance
level of your unit, which will result
in premature failing. Broan-NuTone
recommends to contact a certified
service depot for all replacement
parts and repairs.
KEYNO.PARTNO.DESCRIPTIONQTY.
1SV13296ADAPTER/DAMPER 3¼” X 10”1
2SV03500 AIRDEFLECTOR1
3SV12997SINGLEBLOWERROUGH-INPLATEASSEMBLY1
4SV03577 FOAM 1/2” X 1/2” X 12”1
5SV02160CAPACITOR 15 µF1
6*M
7SV01857WIRECOVER1
8*LOCKNUTNO. 6-321
9SV14973SINGLEBLOWERASSEMBLY1
10SV01810IMPELLERRING1
11SV03400 BLOWERIMPELLER 7.094” X 3.375” CW1
12SV01766MOTOR 165 W CW1
13*WASHER 3/16” ID X 3/4” OD3
14SV02001MOTOR GROMMET G-431-13