IP29M SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION ON
PAGES 12 TO 14.
V08072 rev. A
INSTALLATION INSTRUCTIONS
!
!
In USA - BEST®P.O. Box 140, Hartford, WI 53027 In Canada - BEST®550 Lemire Blvd., Drummondville, QC, J2C 7W9
REGISTER YOUR PRODUCT ON LINE AT: www.bestrangehoods.com/register
For additional information — visit www.bestrangehoods.com
HB0063
WARNING WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN—You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels—This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department has been called. D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
!
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood should be at a minimum of 30” and at a maximum of 36” above the cooking surface.
5. Two installers are recommended because of the large size and weight of this hood.
6. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside—Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
7. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
8. To reduce the risk of fire and electric shock, the Best by Broan IP29M Series hood must be installed with Best by Broan interior blower models P6 or P12; Best by Broan exterior blower models EB6, EB9, EB12 or EB15; Best by Broan in-line blowers models ILB3, ILB6, ILB9, ILB11. Other blowers cannot be substituted. (Blowers sold separately.)
9. Please read specification label on product for further information and requirements.
- 3 -
Model 415
(7” round adjustable elbow)
Model 427
(4
1
/2” x 181/2
to 10” Round,
6” high - lateral
Model 423
(41/2” x 181/2” to
10” Round - vertical
Model 424
(41/2” x 181/2” to
10” Round - horiz.
front/rear
Model 454
(41/2” x 181/2
to 10” Round -
horiz. /right
Model 453
(41/2” x 181/2
to 10” Round -
horiz. /left
IP29M SERIES
HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
OPTIONAL DECORATIVE FLUE AEIP SERIES
OPTIONAL DRYWALL TRIM ATDIP SERIES
- IP29M SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
Model 437
(High capacity roof cap)
Model 441
(10’’ Round wall cap)
Model 634 or 644
(roof cap)
Model 647
(7” Round wall cap)
Model 407
(7” round duct—2 ft. sections)
Model 410
(10” round duct—2 ft. sections)
MODEL P6 BLOWER/ROUGH-IN KIT
(600 cfm interior blower & rough-in plate)
MODEL P12 BLOWER/ROUGH-IN KIT
(1200 cfm interior blower & rough-in plate)
Model 418
(10” round adjustable elbow)
HL0091
- 4 -
- IP29M SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
In-line and exterior blower rough-in kit (included with EB6, EB9, EB12, EB15, ILB3, ILB6, ILB9 and ILB11 blowers.)
Model 418 10” Round
adjustable elbow
(optional)
Model ILB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
Model EB6 (600 cfm)
or EB9(900 cfm)
exterior blower
Model EB12 (1200 cfm)
or EB15 (1500 cfm)
exterior blower
Model 441 (10” Round wall cap)
Model 437
(High capacity roof cap)
Model 441
(10” Round wall cap)
Model 421 (10” Round vert. in-line damper) Recommended for use with exterior blowers
Model 410 (10” Round duct —2ft. sections)
Model ILB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’’ round transitions)
Model ILB9 (800 cfm)
or ILB11 (1100 cfm)
in-line blower
(includes two 8” x 12” to
10’’ round transitions)
IP29M SERIES
HOOD
(Canopy with
blower controls
& lighting.
required for all
installations.)
OPTIONAL DECORATIVE FLUE AEIP SERIES
OPTIONAL DRYWALL TRIM ATDIP SERIES
Model 643 (8” Round wall cap)
HL0090
- 5 -
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
Either an interior or an exterior blower or in-line blower may be used with this hood. The Best by Broan IP29M Series must be installed
with blower models P6, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately.)
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 9, 11 to 15, 17 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct joints.
7” (178) ROUND DUCT
ROOF CAP
30” TO 36” (762 to 914)
ABOVE COOKING SURFACE
HOOD
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(762, 305, 457 or 610)
or TRIM
HH0080A
NOTE: Dimensions in ( ) are in mm.
MODEL P6 SINGLE INTERIOR BLOWER
TYPICAL DUCTWORK
10” (254) ROUND DUCT
ROOF CAP
30” TO 36” (762 to 914)
ABOVE COOKING SURFACE
HOOD
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(762, 305, 457 or 610)
or TRIM
HH0081A
NOTE: Dimensions in ( ) are in mm
ROUND TRANSITION 4½” x 18½” to 10” (114 x 470 to 254) (see page 3)
MODEL P12 DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
10” (254)
ROUND DUCT
EXTERIOR BLOWER
30” TO 36” (762 to 914)
ABOVE COOKING SURFACE
HOOD
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(762, 305, 457 or 610)
or TRIM
HH0082A
NOTE: Dimensions in ( ) are in mm
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER TYPICAL DUCTWORK
IN-LINE BLOWER
HH0083A
30” TO 36” [762 to 914]
ABOVE COOKING SURFACE
ROOF CAP
WALL
CAP
HOOD
NOTE: Dimensions in ( ) are in mm.
DECORATIVE
FLUE
12”, 18”, 24” or 30”
(762, 305, 457 or 610)
or TRIM
10” [254] ROUND DUCT
(except ILB3, 8’’ [203] ROUND DUCT)
MODEL ILB3, ILB6, ILB9 OR ILB11