MODEL ILB6
SPECIFICATION SHEET
Powerful yet quiet blower - exhausts the cooking area
from a remote location.
FEATURES
BLOWER:
• Low RPM for quiet operation
• Resilient anti-vibration mounts
• Dynamically-balanced, galvanized steel, centrifugal
blower wheels for quiet, efficient performance
• Permanently lubricated, thermally protected motor
• Plug-in motor rated at 120 VAC
• Designed for continuous operation
• For indoor use only
HOUSING:
• Rugged galvanized steel
• 8-position mounting brackets for easy installation and
greater adaptability to various mounting requirements
• Automatic backdraft damper located within exhaust
duct connector
• Factory-shipped in horizontal discharge position
• May be converted to vertical discharge
• Suitable for kitchen installations
ACCESSORIES INCLUDED:
• 4½-inch x 18½-inch integrated duct connectors
• Two (2) 4½-inch x 18½-inch to 10-inch-round
transitions
• Hanger kit - for additional installation flexibility
• Range hood rough-in kit with integrated 10-inch duct
connector
SPECIFICATIONS
Volts Hz Amps CFM Duct Weight
120 60 2.9 600 (V) 4½”x18½” * 48.0 lbs.
600 (H)
* Performance ratings include the addition of a 10” round
transition on inlet and outlet.
HVI-2100 CERTIFIED RATINGS comply with new testing technologies
and procedures prescribed by the Home Ventilating Institute, for
off-the-shelf products, as they are available to consumers. Product
performance is rated at 0.1 in. static pressure, based on tests
conducted in a state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory measurements.
BEST Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST Drummondville, QC, Canada www.BestRangeHoods.com 866-737-7770
TYPICAL SPECIFICATION
In-Line Blower shall be Best Model
ILB6.
Unit shall have galvanized steel housing. Housing to have adjustable
mounting brackets.
Blower to include hanger kit, two (2) 4½-inch x 18½-inch to 10-inch-round
transitions, 4½-inch x 18½-inch integrated duct connectors, and a range
hood rough-in kit with integrated 10-inch duct connector.
Automatic backdraft damper to be located within exhaust duct connector.
Duct connectors, blower assembly and wiring plate shall be adjustable
for either horizontal or vertical
installation.
Blower unit shall be removable from
housing and will have galvanized
steel, centrifugal-type blower wheels.
Motor to be permanently lubricated
and mounted with resilient antivibration mounts.
Air delivery shall be no less than
listed. All air ratings shall be certified
4½” x 18½”
DUCT CONNECTOR
by HVI. Unit to be UL and cUL listed.
1.2
1.1
1
0.9
0.8
0.7
0.6
0.5
0.4
STATIC PRESSURE (IN-WG)
0.3
0.2
0.1
0
0 100 200 300 400 500 600 700
VERTI CAL
HORIZO NTAL
AIR FLOW RATE (CFM)
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
01B 99043708F