Best ILB3 Specifications

IN-LINE BLOWER
HLB3
MODEL ILB3
SPECIFICATION SHEET
Powerful yet quiet blower - exhausts the cooking area from a remote location.
FEATURES
BLOWER:
• Low RPM for quiet operation
• Resilient anti-vibration mounts
• Dynamically-balanced, galvanized steel, centrifugal blower wheel for quiet, efficient performance
• Permanently lubricated, thermally protected motor
• Plug-in motor rated at 120 VAC
• Designed for continuous operation
• For indoor use only
HOUSING:
• Rugged galvanized steel
• 8-position mounting brackets for easy installation and greater adaptability to various mounting requirements
• Automatic backdraft damper located within exhaust duct connector
• Factory-shipped in horizontal discharge position
• May be converted to vertical discharge
• Suitable for kitchen installations
ACCESSORIES INCLUDED:
• 8-inch round integrated duct connectors
• One (1) 8-inch to 10-inch-round transition
• Hanger kit - for additional installation flexibility
• Range hood rough-in kit with integrated 10-inch duct connector
SPECIFICATIONS
Volts Hz Amps CFM Duct Weight
120 60 2.6 260 (V) 8” Round * 30.6 lbs.
2.7 280 (H)
* Performance ratings include the addition of a 10” round
transition on inlet.
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the­art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
BEST Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
TYPICAL SPECIFICATION
In-Line Blower shall be Best Model ILB3.
Unit shall have galvanized steel housing. Housing to have adjustable mounting brackets.
Blower to include hanger kit, one (1) 8-inch to 10-inch-round transition, 8-inch round integrated duct connectors, and a range hood rough-in kit with integrated 10-inch duct connector.
Automatic backdraft damper to be located within exhaust duct connector. Duct connectors, blower assembly and wiring plate shall be adjustable for either horizontal or vertical installation.
Blower unit shall be removable from housing and will have a galvanized steel, centrifugal-type blower wheel. Motor to be permanently lubricated and mounted with resilient anti­vibration mounts.
Air delivery shall be no less than listed. All air ratings shall be certified by HVI. Unit to be UL and cUL listed.
1.2
1.1
1
0.9
0.8
0.7
0.6
0.5
0.4
STATIC PRESSURE (IN-WG)
0.3
0.2
0.1
0
0 50 100 150 200 250 300
AIR FLOW RATE (CFM)
8” ROUND
DUCT CONNECTOR
HORIZO NTAL
VERTI CAL
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
01B 99043706F
Loading...