Best FTK4136PB, FTK4236PB Specifications

Class pyramidal lines create a statement of simple elegance.
FEATURES
Italian design
Wall mount
Finishes: 304 Stainless Steel #4 Brushed, White, Black,
Polished Brass, Brushed Copper Widths: 30”, 36”
Telescopic flue accommodates 8’ to 9’ ceilings
6” round duct connector/backdraft damper
Convertible to non-ducted operation (for 8’ to 9’ ceilings
only - requires Model No. REKITK41 sold separately) Halogen lighting (2 x 20 watt, MR16 - bulbs included)
Slide controls: on-off, infinite speed
Single centrifugal blower
Dishwasher-safe filter features a quick-release latch and
decorative cover plate Heat SentryTM - automatically turns blower to high speed
when excess cooking heat is detected
SPECIFICATION SHEET
min 33"
max 47"
OPTIONS
Backsplash available (Model BSK1)
Accent trim in contrasting or complementary finishes
(Model No. FTK41) Flue extension for 10’ ceiling (ducted only) (Model No.
FEXTK42) (31-7/8” long) Recirculating filter (Model No. ROUND FILTER)
Replacement grease filters available
Replacement bulb (Part No. SB02300668)
SPECIFICATIONS
VOLTS AMPS CFM SONES DUCT
120 3.13 500 8.0 6” round
BEST BY BROAN P.O. BOX 140 HARTFORD, WISCONSIN 53027
REFERENCE QTY. REMARKS Project
Mount range hood so bottom of hood is
24” minimum above cooking surface.
Location
Architect
Engineer
Contractor
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in AMCA’s state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
Submitted by Date
50J 99042839C
K41 SERIES WIRING
Wiring Box
4-1/4”
K41 SERIES MOUNTING
Air Outlet Ø 5-7/8”
FRAMING BEHIND WOOD
CROSS SUPPORT
STUD
WOOD CROSS
SUPPORT – SECURED
TO FRAMING AND
LOCATED BEHIND
DRYWALL
3 "
L
C
L
3 4
DRYWALL
3
3 "
4
STUD
MOUNTING DISTANCE ABOVE 36” HIGH COOKTOP (SEE NOTE BELOW)
CEILING DUCT HEIGHT METHOD
8 FEET
9 FEET
10 FEET
NOTE: Minimum hood distance above cooktop must not be less than 24”.
DUCTED OR NONDUCTED with REKITK41
DUCTED 37-3/16” 38-3/16” 39-3/16” 40-3/16” 41-3/16” 42-3/16”
NONDUCTED with REKITK41
DUCTED WITH
FEXTK42
A maximum of 30” above the cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users’ discretion; and if ceiling height and flue length permit.
24” 25” 26” 27” 28” 29” 30”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
36-3/16” 37-3/16” 38-3/16” 39-3/16”
38-3/16” 39-3/16” 40-3/16” 41-3/16” 42-3/16”
41-3/16” 42-3/16”
3
2 "
16
MOUNTING BRACKET LOCATION (ABOVE 36” HIGH COOKTOP)
BEST BY BROAN P.O. BOX 140 HARTFORD, WISCONSIN 53027