Model EB15
EXTERIOR MOUNTED
BLOWER
For use with compatible
Best by Broan range hoods.
See hood manual for suitability.
BEST BY BROAN, P.O. BOX 140 HARTFORD, WI 53027
READ AND SAVE THESE INSTRUCTIONS
MODEL
EB15
EXTERIOR
BLOWER
WALL HOOD
CANOPY
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
21" or 24"
10"
or
18"
10" ROUND ELBOW
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must
be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American
Society for Heating,
SPECIFICATIONS
WARNING
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or
other hidden utilities.
6. Ducted fans must always be vented to
the outdoors.
7. To reduce risk of fire, use only metal
ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not
use to exhaust hazardous or explosive
material and vapors.
2. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
3. Please read specification label on product for further information and requirements.
4. Electrical circuit, including speed control,
(if used), must be rated 6 AMPS minimum.
INSTALLER: Leave This Manual
With The Homeowner.
HOMEOWNER: Use And Care
Information On Page 6.
MODEL VOLTS AMPS CFM DUCT SIZE
EB15 120 4.3 1500 10 " DIA.
PLAN THE INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the length of the
duct run and number of elbows are
kept to a minimum.
2. Where possible, blower
should be centered between wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
be running through the
wall.
4. Attach mounting plate to
top of hood.
5. Install 10” dia. ductwork
and 120 VAC house wiring between blower location and hood location.
SOFFIT
LL HOOD
ANOPY
MODEL EB15
EXTERIOR BLOWER
21" or 24"
2
10" ROUND
10"
or
18"
DUCT
ROUGH-IN
PLATE
TYPICAL
ROOF MOUNTED
INSTALLATION
TYPICAL WALL
MOUNTED
INSTALLATION
PREPARE THE
18"
12
11
/
16"
1¼" dia. hole
Guide hole
(centered
between rafters)
11" dia.
hole
22"
Guide hole
(centered between studs)
INSTALLATION LOCATION
PREPARE THE
INSTALLATION LOCATION
ROOF INSTALLATIONS WALL INSTALLATIONS
1. Locate the blower on the rear slope of
the roof. Place it in a location to minimize
duct run. The location should be free of
obstacles (T.V. leads, electrical lines,
etc.). If the blower top is level with the
roof peak, it will not be seen from the
street. Keep this approximate location in
mind as you work from within the attic.
2. Mark and drill a guide hole centered
between roof rafters.
Ø
18"
Ø
1¼" dia. hole
REMOVE SHINGLES
11
12
/
16"
1"
1. Choose a position on the outside wall.
Make sure that no wall studs, pipes or
wires run through the opening area.
2. From inside, mark and drill a guide hole
centered between wall studs.
14
Ø
Ø
11
/
16
"
20"
1¼" dia. hole
Guide hole
(centered between studs)
3
"
29½"
3. From the outside, use the guide hole as
A. Use a T-square to measure 12
B. Starting from the top-left corner, mark
C. Mark an 11" diameter hole centered on
D. Mark and cut a 1¼" diameter hole
4. For flat
20½"
Guide hole
(centered
between rafters)
Roof Rafter
5
12
/
8"
21"
11" dia.
a starting point to lay out the installation:
hole
Roof Rafter
5
/8" to the
left of the guide hole, then up 1211/16" to
locate the top-left corner of the layout.
the rectangular cutout (21" W x 20½" H)
remove only the shingles in this
and
area.
the guide hole. Cut this hole through the
roof board(s).
through
the roof
board(s)
where
shown.
roof installations,
build a
curb that
will
mount the blower at a minimum pitch of
2/12. Discharge end of the blower should
be pointed downward.
29-1/2"
25"
2"
2"
Wall Stud
REMOVE
SIDING
14
11" dia.
hole
5
/
8
"
25"
3. From the outside, use the guide hole as
a starting point to lay out the installation:
A. Use a T-square to measure 14
left of the guide hole, then up
to the
11
/16" to locate the top-left corner
14
of the layout.
B. Starting from the top-left corner,
mark the rectangular cutout (25" W
x 29½" H) and
remove only the
siding in this area.
C. Mark an 11" diameter hole cen-
tered on the guide hole. Cut this
hole through the roof board(s).
D. Mark and cut a 1¼" diameter hole
through the roof board(s) where
shown.
7"
3
Wall Stud
5
/8"