TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must
be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American
Society for Heating,
SPECIFICATIONS
WARNING
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or
other hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. To reduce risk of fire, use only metal
ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not
use to exhaust hazardous or explosive
material and vapors.
2. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
3. Please read specification label on product for further information and requirements.
4. Electrical circuit, including speed control,
(if used), must be rated 6 AMPS minimum.
INSTALLER: Leave This Manual
With The Homeowner.
HOMEOWNER: Use And Care
Information On Page 6.
MODELVOLTSAMPSCFMDUCT SIZE
EB121203.0120010 " DIA.
PLAN THE INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the length of the
duct run and number of elbows are kept
to a minimum.
2. Where possible, blower
should be centered between wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
be running through the
wall.
4. Attach mounting plate to
top of hood.
5. Install 10” dia. ductwork
and 120 VAC house wiring between blower location and hood location.
MODEL EB12
EXTERIOR BLOWER
SOFFIT
WALL
HOOD
CANOPY
21" or 24"
10"
or
18"
2
10" ROUND
DUCT
ROUGH-IN
PLATE
10" ROUND ELBOW
10" ROUND DUCT
SOFFIT
WALL
HOOD
CANOPY
21" or 24"
10"
or
18"
TYPICAL WALL
MOUNTED
INSTALLATION
TYPICAL
ROOF MOUNTED
INSTALLATION
MODEL
EB12
EXTERIOR
BLOWER
ROUGH-IN
PLATE
PREPARE THE
11" dia.
hole
20½"
Ø
9
13
/
16"
Ø
18"
12
11
/
16"
1¼" dia. hole
Roof Rafter
Roof Rafter
REMOVE SHINGLES
Guide hole
(centered
between rafters)
11" dia.
hole
22"
Guide hole
(centered between studs)
29½"
11
13
/
16
"
17"
1¼" dia. hole
Ø
Ø
REMOVE
SIDING
INSTALLATION LOCATION
PREPARE THE
INSTALLATION LOCATION
ROOF INSTALLATIONSWALL INSTALLATIONS
1. Locate the blower on the rear slope of
the roof. Place it in a location to minimize
duct run. The location should be free of
obstacles (T.V. leads, electrical lines,
etc.). If the blower top is level with the
roof peak, it will not be seen from the
street. Keep this approximate location in
mind as you work from within the attic.
2. Mark and drill a guide hole centered
between roof rafters.
Ø
15"
Ø
1¼" dia. hole
REMOVE SHINGLES
11
12
/
16"
1"
1. Choose a position on the outside wall.
Make sure that no wall studs, pipes or
wires run through the opening area.
2. From inside, mark and drill a guide hole
centered between wall studs.
14
Ø
Ø
11
/
16
"
17"
1¼" dia. hole
Guide hole
(centered between studs)
3
"
29½"
3. From the outside, use the guide hole as
A. Use a T-square to measure 9
B. Starting from the top-left corner, mark
C. Mark an 11" diameter hole centered on
D. Mark and cut a 1¼" diameter hole
4. For flat
20½"
Guide hole
(centered
between rafters)
Roof Rafter
13
9
/
16"
18"
11" dia.
a starting point to lay out the installation:
hole
Roof Rafter
13
/16" to the
left of the guide hole, then up 1211/16" to
locate the top-left corner of the layout.
the rectangular cutout (18" W x 20½" H)
remove only the shingles in this
and
area.
the guide hole. Cut this hole through the
roof board(s).
through
the roof
board(s)
where
shown.
roof installations,
build a
curb that
will
mount the blower at a minimum pitch of
2/12. Discharge end of the blower should
be pointed downward.
29-1/2"
22"
2"
2"
Wall Stud
REMOVE
SIDING
13
11
11" dia.
hole
/
16
"
22"
3. From the outside, use the guide hole as
a starting point to lay out the installation:
A. Use a T-square to measure 11
left of the guide hole, then up
to the
11
/16" to locate the top-left corner
14
of the layout.
B. Starting from the top-left corner,
mark the rectangular cutout (22" W
x 29½" H) and
remove only the
siding in this area.
C. Mark an 11" diameter hole cen-
tered on the guide hole. Cut this
hole through the roof board(s).
D. Mark and cut a 1¼" diameter hole
through the roof board(s) where
shown.
7"
3
Wall Stud
13
/16"
INSTALL THE BLOWER
INSTALL THE BLOWER
ROOF INSTALLATIONS
1. Remove the cover and screws.
2. Attach an appropriate U.L. approved
cable connector in the hole at the rear of
the wiring box.
3. Remove roofing nails from shingles
around the TOP and SIDES of the cutout
area only.Carefully lift the shingles to
allow the back flashing sheet on the
blower housing to fit under them.
4. Center the blower ring in the 11" diameter hole, making sure that the 1¼"
diameter electrical wiring hole aligns with
the hole in the wiring box.
5. Attach the blower to the roof with six (6)
screws provided. It is recommended that
the screws be located inside the blower
housing. Drill pilot holes if necessary.
6. Using a good grade of roofing cement,
seal all of the shingles around the housing and flashing sheet as well as the
mounting screw heads.
7. Bring electrical wiring through the hole in
the wiring box and secure it according to
local codes.
8. Make the electrical connections with the
WALL INSTALLATIONS
side of the housing all along the outer
edges.
2. Center the blower ring in the 11" diameter hole, making sure that the 1¼"
diameter electrical wiring hole aligns with
the hole in the wiring box.
3. Attach blower to the wall with the six (6)
screws provided. It is recommended that
the screws be located inside the blower
housing. Drill pilot holes if necessary.
4. Using a good grade of caulk, seal all
around the mounting screw heads.
5. Bring electrical wiring through the hole in
the wiring box and secure it according to
local codes.
6. Make the electrical connections with the
proper connector for the type of wire
GROUND
TO
GROUNDING
SCREW
WHITE
TO
BLUE
GROUND
TO
GROUNDING
SCREW
WHITE
TO
BLUE
120 VAC
LINE
IN
BLACK
TO
BLACK
proper connector for the type of wiring
being used. Connect black to black, white
to blue, and the green or bare wire to
grounding screw.
9. Replace cover and screws. Do not pinch
wiring under the cover.
10. Make sure damper opens and closes
freely.
1. Place a large bead of caulk on the back
120 VAC
LINE
IN
BLACK
TO
BLACK
being used. Connect black to black, white
to blue, and green or bare wire to grounding screw.
7. Replace cover and screws. Do not pinch
wiring under cover.
8. Make sure damper opens and closes
freely.
9. Top and side flanges of the back plate
may be covered with trim strips. Do not
block grille opening at bottom with trim.
It will adversely affect performance of
the blower.
4
WARRANTY
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of
one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use and
service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and
service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan),
faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION,
SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER
THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not
allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated
below or telephone: 1-800-637-1453, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the
original purchase date.
BEST BY BROAN, P.O. Box 140, Hartford, WI 53027
5
USE AND CARE
Disconnect electrical power supply and lock out service panel before cleaning or servicing this unit.
CLEANING
Remove cover and carefully
vacuum blower and inside of housing. Be careful not to bend or otherwise damage blower wheel.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble
motor.
1
2
14
13
15
16
3
17
4
7
5
13
6
SERVICE PARTS
MODEL EB12
KEYPART
NO.NO.DESCRIPTION
198009429Cover
299100532Foam Seal
398009430Motor Support
498009497Damper Flap (2 req.)
599140145Damper Spring (2 req.)
698009486Grille
799080478Blower Assembly
899271202Capacitor
999271222Wire Assembly
1099100530Terminal Boot
1199390136Capacitor Clamp
1299400079Bushing
1399150478Screw, 8-18 x 3/8 Ph Tr Hd (12 req.)
1499170269Screw, M6 x 1.0-16 (4 req.)
1599250958Washer, Lock, Int. Tooth, ¼ (5 req.)
1699150506Screw, 12-24 x .312 SLT HWH #2
1799270461Cord Clamp
1899260477Nut, Whiz, ¼-20 (9 req.)
1999150471Ground Screw, 10-32 x ½ Slt Hx Hd
(2 req.)
2099160411Screw, ¼-20 x ½ Ph Pan Hd (9 req.)
18
18
10
11
8
12