MODELS DDEX30SS,
DDEX36SS, DDEX48SS
REMOTE DOWNDRAFT
SPECIFICATION SHEET
Exhaust your cooktop without the use of an overhead hood. Control a powerful exterior blower (6001500 CFM) from the cooktop location. Compact
design is installed directly behind cooktop.
FEATURES
HOUSING:
Rugged steel construction
•
Finished with silver paint
•
Space-saving - can be used with most cooktops on the
•
market
30", 36", or 48" widths - Fits standard-size cabinets
•
CHIMNEY ASSEMBLY:
Brushed stainless steel cover - just press button to turn
•
unit "ON"
Chimney rises 9½" when activated - ideal for large pots
•
and pans
Stylish, stainless steel filters with aluminum mesh - easy
•
to remove and dishwasher-safe
Stainless steel chimney front and back - makes cleanup
•
quick and easy
Top cover mounted 3 speed control, with delay off and
•
clean filter reminder
Heat Sentry adjusts speed of blower in case of excess
•
heat
Conveniently located button - press to lower air vent and
•
turn unit "OFF"
Remote Control activates downdraft from alternate loca-
•
tion
DUCT CONNECTOR HOUSING:
Rugged steel construction with galvanized finish
•
3¼" x 14" rectangular duct connector (8" round duct using
•
Model 459 transition)
3-position discharge - movable to adjust to floor joists
•
TYPICAL SPECIFICATION
Downdraft blower system shall be Best by Broan Model
DDEX30SS (DDEX36SS) (DDEX48SS).
Unit to have steel housing with silver paint finish. Air vent to
rise at least 9½" and have a stainless steel front and back for
ease of cleaning.
Filters to be stainless steel with aluminum mesh, easy to
remove and dishwasher-safe.
3¼" x 14" duct connector shall be adjustable to accomodate
ductwork from left, right or below and have 7½" side to side
adjustment.
Unit to include remote control activation button.
Unit to include Heat Sentry, to adjust blower speed in case
of excess heat.
Downdraft system shall operate on 120 VAC and be able to
be plugged into a standard grounded outlet. It will have a 3
speed blower control, with delay off and a clean filter reminder.
SPECIFICATIONS
VOLTS HZ AMPS DUCT
120 60 6 3¼" x 14"
Best by Broan, P.O. Box 140, Hartford, WI 53027
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
50H 99043192B
INSTALLATION PLANNING • MODELS DDEX30SS, DDEX36SS, DDEX48SS
DIMENSIONS
NOTE: Dimensions shown are for reference only. Before cutting
out countertop, refer to instructions packed with downdraft and
cooktop.
*
*
Dimensioned from top
*
of countertop
DOWNDRAFT
A
COUNTER TOP
COOKTOP
FRONT TO BACK
INSIDE CABINET DEPTH
Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The
DDEX30SS can be installed in most standard 30" wide cabinets,
(DDEX36SS can be installed in most standard 36" wide cabinets), (DDEX48SS can be installed in most standard 48" wide
cabinets).
Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the 4 areas of potential interference
highlighted above. A countertop with (A) a raised lip and/or (B)
a backsplash, may not allow enough flat countertop for a proper
installation. The back of the downdraft cut-out will be 1¾" from the
cooktop and 2" of FLAT countertop is needed behind cooktop.
1 3/4 "
2"
B
DOWNDRAFT
DUCTWORK
TYPICAL INSTALLATION
COUNTER
CABINET
FRONT
TOP
COOK TOP
GEAR
MOTOR
COVER
BLOWER
BOX
3-1/4" X 14"
DUCT CONNECTOR
CHIMNEY TOP
AIR
VENT
120 VAC
GOUNDED
OUTLET
ELECTRICAL
The unit has an 18-in. power cord with a 3-pronged plug. Plan to
provide a grounded outlet within reach of this cord.
This downdraft blower system is designed for use with 3¼" x 14"
rectangular, or 8" round duct. The blower discharge can be
positioned in one of 3 directions with 7½" movement side to side.
RIGHT
DISCHARGE
LEFT
DISCHARGE
3¼" x 14" TO
8" RD.
TRANSITION
5 FT.
3¼" X 14"
90o ELBOW
DOWN
DISCHARGE
(as shipped)
8" RD.
ELBOW
19 FT.
11 FT.
The system will operate most efficiently when the ductwork does
not exceed 40 feet of equivalent duct. The chart above, shows
equivalent feet of elbows and transitions. The number of feet of
straight 3¼" x 14" or 8" duct plus the equivalent feet of elbows or
transitions to be used should equal 40 feet or less.
The equivalent feet of various roof and wall caps has been taken
into consideration. Do not include them in this calculation.