Best D49M48SB Specifications

CATTURATM DOWNDRAFT
MODELS D49M30SB, D49M36SB, D49M48SB
SPECIFICATIONS
Page 1
FEATURES
HOUSING:
Galvanized steel construction
Left, right, front, or rear discharge
Flexible installation - can be used with cooktops, rangetops,
slide-in, and free-standing ranges
30", 36", or 48" widths - Fits standard-size cabinets (Some blower configurations may require deeper cabinets.)
For indoor domestic use only
CHIMNEY ASSEMBLY:
Quiet actuation linear drive system
Chimney rises 18" when activated - ideal for tall pots
Aluminum mesh filters - easy to remove, dishwasher-safe
304 stainless steel chimney - makes cleanup quick and
easy
4-speed capacitive-touch control, with delay off and filter clean reminder
Heat Sentry heat
2-level LED task light. 7W (30"), 14W (36"), 18W (48")
Up to 100% capture - equal to comparable island hoods
TRIM / DOOR:
Low profile
304 stainless steel construction
Articulating door to hide chimney when retracted
Integrated, capacitive-touch UP button
BLOWER (sold separately):
Compatible with quiet and efficient 600 cfm Flex Blower ­Model PF6
Permanently lubricated, thermally-protected motor
Neoprene, resilient anti-vibration mounts
Can be mounted directly to downdraft or mounted remotely
Uses standard 8" round duct
Can be rotated on housing to exhaust left, right or down
Compatible with in-line/exterior blower models:
EB6, EB9*, EB12*, EB15*, ILB3, ILB6, ILB9, ILB11*
*
Recommended models
TM
Complete Capture Design rivals the
TM
adjusts speed of blower in case of excess
TYPICAL SPECIFICATION
Downdraft blower system shall be Best (D49M36SB), (D49M48SB).
Unit to have stainless steel housing. Chimney to rise 18" and have 304 stainless steel contruction for ease of cleaning.
Filters to be aluminum mesh, easy to remove and dishwasher­safe.
Blower will connect directly to 8" round duct. Remote application uses 1-7/8" x 19" to 8" round transition (1-7/8" x 19" to 10" round transition), (8"/10" round plate). Blower to discharge left, (right), (front), (rear).
Motor shall be mounted to blower assembly with grease resistant anti-vibration mounts, be removable, and lifetime lubricated.
Unit to include Heat Sentry excess heat.
Unit to include trim / door to hide chimney when retracted.
Downdraft system shall operate on 120 VAC and be able to be plugged into a standard grounded outlet. It will have a 4-speed blower control, with delay off, and filter clean reminder.
Downdraft shall include 2-level LED task lighting.
Downdraft blower system to be cULus listed.
TM
, to adjust blower speed in case of
®
Model D49M30SB,
SPECIFICATIONS
Volts: 120 Hz: 60 Amps: 3.2 Duct: 8" Round
NOTE: Dimensions shown are for reference only. Before cutting out countertop, refer to instructions packed with downdraft and cooktop.
BEST Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
61D 99045243D
CABINET CUTOUTS
!
5 ”
CAUTION: BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing.
REAR CORNER OF
COOKTOP CUT-OUT
7
/
8
2”
centered
4”
INSIDE
CABINET FLOOR
INSTALLATION
CENTER LINE
HOLE
FOR
7
1 ” X 19”
/
8
DUCT &
TRANSITIONS
21”
1½”
24¾”
INSIDE
CABINET BACK
4”
B
PLANNING
Page 2
DOWNDRAFT
A
COUNTER TOP
COOKTOP
FRONT TO BACK
INSIDE CABINET DEPTH
Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. However, it is recommended that oversized cabinets be used for easier installation. Custom island designs need to account for deeper cabinets - especially when installed with a range in front of the downdraft or when mounting the blower behind the downdraft. You must also plan for an access door.
Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2-3/4" of flat countertop is required
A
behind cooktop and that 2-1/2" is necessary between the back edge of the cooktop and the inside of cabinet back.
2-1/2"
2-3/4"
B
DOWNDRAFT
Hole in Cabinet Floor
Dimension A Dimension B
Using Flex Blower (Model
PF6 & 8" round duct
straight down through
cabinet floor.)
(1½" left of installation
center line)
5-5/8 inches
Using Exterior or In-Line Blower &
0
90
Duct Elbow
(on installation
center line)
7-5/8
inches
(Model
432 - 8"
inches
(Model
418 - 10"
round
elbow)
elbow)
8-5/8
round
Use the dimensions in the above illustration to help plan how and where to provide duct access through your cabinet. Generally, 1-7/8" x 19" rectangular duct will be used through left, right, and back of cabinet - while 8" round duct will be used through cabinet floor.
For left, right, or rear exhaust: Allow at least 18" for transition and elbow or blower.
For left / right exhaust:
A 30" deep cabinet is recommended to align properly with flex blower. Flex blower can be mounted to rear cabinet wall or to a platform / frame (not provided) on the base of the cabinet floor. (See flex blower instruc­tions).
Cabinet depths of 24" to 30" are required - depending on the type of cooking appliance.
ELECTRICAL PANEL
The unit has a 30-in. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord.
DUCTWORK
HOUSING
FLEX
Remote
*
blowers use 8" or 10" round remote discharge plate instead of flex blower.
A
D
BLOWER
The downdraft blower system is designed for use with 8" round ductwork using a Flex Blower or 10" round ductwork using a remote blower. (Purchase blowers separately.) Six (6) different discharge connections are available - with side-to­side adjustment for accurate alignment of ductwork:
A = 8" Round, Left Discharge out of Flex Blower B = 8" Round, Right Discharge out of Flex Blower C = 8" Round, Down Discharge out of Flex Blower (Electrical Panel to be
mounted remotely)
D = 1-7/8" x 19", Left Discharge out of Housing to Remote Blower or Flex
Blower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
E = 1-7/8" x 19", Right Discharge out of Housing to Remote Blower or Flex
Blower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
F = 1-7/8" x 19", Rear Discharge out of Housing to Remote Blower or Flex
Blower in remote location. Use 1-7/8" x 19" to 8" round transition, 1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
For best performance: Choose the ducting option which allows the shor test length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference.
*
C
F
B
E
ELECTRICAL
PANEL
OPTIONAL ACCESSORIES
Page 3
OPTIONAL
ACCESSORY
MODEL ACRD
MODELS ATSKD30 ATSKD36 ATSKD48
MODELS
MD6T MD8T
MD10T
DESCRIPTION /
APPLICATION
REMOTEUP/DOWN CONTROL
Use when you cannot reach the UP/ DOWN Button on the downdraft chimney.
Can be located on counter top, face of cabinetry or on the side cabinet of an island. Cut-out size: 2¼" H x 2" W.
Cannot be used where remote control will interfere with cooking, where hot pans could be set, or where hot liquids could be spilled on the control.
Remote wiring connects with 6-pin con­nector on control box.
GAS COOKTOP SEAL KIT
Recommended for use with all gas cooktops. Includes trim bracket and trim seal.
30", 36" & 48" widths.
MAKE-UP AIR DAMPER
Use to provide make-up air when called for to keep the home comfortable by allowing the downdraft to operate at optimum levels.
Directwire design works with select
®
downdrafts to balance indoor
BEST air pressure by providing interlocked make-up air; damper opens automati­cally when the range hood is activated
8" round & 10" round diameters.
Connects to 2 CONTACTS on
ELECTRICAL PANEL.
OPTIONAL
ACCESSORY
MODEL AEWD5
MODEL ANKD
MODEL AFCD
MODEL AVDKD8
DESCRIPTION /
APPLICATION
EXTENSION CABLE - 5-FT.
Use where electrical panel is remotely mounted. Extends electrical panel ca­ble an additional 5-feet.
NON-DUCT RECIRCULATING KIT
Use where ducting is not feasible or available. Mount to toe kick or base of a cabinet and attach directly to Model PF6 Flex Blower using 8" round duct. Kit can be rotated so that the exhaust is not directly at your feet. Includes recirculation filter and decorative cover plate.
RECIRCULATION FILTER REPLACEMENT
Replacement filter for ANKD Non-Duct Recirculating Kit. Use to effectively capture cooking contaminants.
1-7/8" X 19" TO 8" ROUND TRANSITION
Rectangular to 8" round transition for left, right, or rear exhaust - using Model PF6 Flex Blower. Can be attached to downdraft unit or rectangular duct (AEDD2).
MODELS
ATKD30SB ATKD36SB ATKD48SB
MAKE-UP
AIR DAMPER
CONTACTS
RANGE TRIM KIT
Use with free-standing range - where a gap is present between back of range and downdraft.
30", 36" & 48" widths.
1-7/8" X 19" TO 10" ROUND TRANSITION
Rectangular to 10" round transition for left, right, or rear exhaust - using Model PF6 Flex Blower. Can be attached to downdraft unit or rectangular duct (AEDD2).
MODEL AVDKD10
RECTANGULAR ADAPTOR FOR 1-7/8" X 19"
Use to connect 1-7/8" x 19" rectangular duct directly to downdraft when using side or rear exhaust.
MODEL AVDKD219
OPTIONAL ACCESSORIES
Page 4
OPTIONAL
ACCESSORY
MODEL ATTD1
MODEL ACVPD8
MODEL ACVPD10
DESCRIPTION /
APPLICATION
END CAP TRIM EXTENSION +1" WIDTH - LH & RH
Use left and right to increase the overall trim width by 1" - to 31", 37" and 49".
FRONT PANEL ROUGH-IN PLATE ­8" ROUND
Use where 8" round duct or elbow attaches to front of airbox (Model PF6 remote blower installation).
FRONT PANEL ROUGH-IN PLATE ­10" ROUND
Use where 10" round duct or elbow attaches to front of airbox (exterior or in-line blower installation).
OPTIONAL
ACCESSORY
MODEL AVDKD8810
DESCRIPTION /
APPLICATION
Y-DUCT CONNECTOR
10" round to dual 8" round.
Galvanized steel construction.
MODEL 432 - 8" RD.
MODEL 418 - 10" RD.
MODEL 408 - 8" RD.
MODEL 410 - 10" RD.
0
90
DUCTWORK ELBOW
Adjustable from straight to 90
0
.
Galvanized steel construction.
STRAIGHT ROUND DUCT - 2-FT.
Galvanized steel construction.
RECTANGULAR DUCT - 2-FT. SECTIONS (1-7/8" X 19")
Galvanized steel construction.
MODEL AEDD2